• Title/Summary/Keyword: 전달길이

Search Result 452, Processing Time 0.026 seconds

Measurement method of the signal transfer characteristic(S21) of the impedance transformer (임피던스 변환회로의 신호 전달특성(S21) 측정 방법)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.10
    • /
    • pp.1282-1289
    • /
    • 2019
  • In order to measure the transfer characteristic(S21) of the impedance transformer, two impedance transformers must be symmetrically connected. However, the transfer characteristic of two symmetrically connected impedance transformers is influenced by the length of the intermediate connection line. This paper theoretically examines closely the length of the intermediate connection line to obtain the accurate transfer characteristic of the impedance transformer. The electrical length of the intermediate connection line for obtaining the accurate transfer characteristic of the 4:1(50-Ω:12.5-Ω) impedance transformer is calculated about 45°. Using the calculated length of the connection line, The λ/4-microstrip impedance transformer is fabricated at 1 GHz to measure the transfer characteristic. The symmetrically connected impedance transformer is measured the reflection characteristic(S11) of -40.64dB and the transfer characteristic(S21) of -0.154dB at 0.980GHz. This value is approximately equal to the theoretical calculated 987MHz center frequency and -0.15dB transfer loss value of the λ/4-microstrip impedance transformer.

Influence of Cover Size on Transfer Length of Prestressing Strand in Pretensioned Prestressed Ultra High Perfrmance Concrete Members (피복에 따른 초고성능 콘크리트 프리텐션부재의 응력전달길이 변화)

  • Park, Jong-Sup;Lee, Kyu-Wan;Kim, Byong-Suk;Joh, Chang-Bin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.95-96
    • /
    • 2009
  • In this paper, the transfer lengths in pretensioned prestressed Ultra High Performance Concrete members are verified to collect the basis data of UHPC increased in practical uses recently. The cover sizes and pretension forces were the main parameters of UHPC.

  • PDF

The effect of a pole length on damping force of MR engine mount (MR엔진마운트의 전극 길이가 감쇠력에 미치는 영향에 대한 실험적 연구)

  • Kang, Yung-Suk;Lee, Hyun-Chang;Lee, Hyung-Sik;Park, Woo-Cheul
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.11a
    • /
    • pp.323-325
    • /
    • 2007
  • 본 연구에서는 MR유체를 적용한 엔진마운트 시스템을 제안하고, 자지장이 형성되는 전극의 길이변화가 엔진마운트의 감쇠력 변화에 미치는 영향에 대하여 실험적으로 고찰하였다. 가진주파수가 증가할수록 마운트로부터 전달되는 힘은 감소하지만, 공급하는 전류의 세기가 증가할수록 전달되는 힘은 증가하였다. 그러나 전극부의 길이변화는 전달되는 힘의 변화에 영향을 거의 미치지 않음을 확인하였다.

  • PDF

A CFD Analysis on the Gas-Liquid Ejector (가스-액체 이젝터에 대한 CFD 해석)

  • Jeong, H.M.;Utomo, Tony;Jin, Z.H.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.12 no.1
    • /
    • pp.28-34
    • /
    • 2008
  • 가스-액체 이젝터에 관한 수치해석은 3차원 CFD 모델로 수행하였다. 본 논문에서는 이젝터의 유동특성과 질량전달특성에 대한 작동조건과 이젝터의 기하학적 모형의 영향에 관한 연구를 수행하고자 한다. CFD 결과 실험 데이터에 의하여 검증되었으며, 유동 분석과 이젝터 성능의 예측 또한 실행되었다. 작동상태의 변화는 0.2 $\sim$ 1.2 범위에서 가스-액체 유량비를 변화시킴으로서 주어진다. 혼합관의 $L_M/D_M$이 4 $\sim$ 10의 범위에서 변화를 주었다. CFD 연구는 길이와 직경비가 5.5일 때 체적 유량전달계수는 가스 유량이 증가함에 따라 증가한다는 것을 나타낸다. 동시에 $L_M/D_M$가 4일 때 체적유량전달계수는 기체-액체 유량비가 0.6에서 최대치에 도달한다. 또한, 체적 유량전달계수는 혼합 튜브길이가 증가함에 따라 감소한다.

  • PDF

A Study on Signal Transmission Specific Property HSTL of Backplane Processor (Backplane processor의 HSTL 신호전달 특성 연구)

  • 김석환;류광렬;허창우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.355-358
    • /
    • 2003
  • 본 문서는 백프레인(backplane)에서 프로세서 HSTL(High-speed Transceiver Logic)의 데이터 전송 및 수신 특성을 알아보기 위해 HSPICE를 사용하여 시뮬레이션을 하였으며 Xilinx Virtex II XC2V FF896 FPGA를 이용하여 직접 제작 신호 전달특성을 분석하였다. PCB(Printed Circuit Board)는 FR-4를 사용하였으며 point to point 배선 길이에 대해 데이터 전송속도 특성을 시험하였고 구현 가능한 데이터 전송 및 수신 한계 속도에 대해 검토하였다. 시험결과 point to point 접속 신호 전송 및 수신 한계속도에 영향을 주는 것이 배선 길이와 주변 전기적 잡음이 중요한 역할을 함을 알 수 있었다.

  • PDF

Bond Characteristics of Ultra High Performance Concrete (초고성능 콘크리트(UHPC)의 부착특성에 관한 연구)

  • Kook, Kyung-Hun;Shin, Hyun-Oh;Kwahk, Im-Jong;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.753-760
    • /
    • 2010
  • Ultra high performance concrete (UHPC), is characterized by its high compressive strength and advanced tensile behavior that is much superior to those of conventional concrete. In order to apply this new material in practice, the bond characteristics of UHPC were evaluated in this study. Pull-out tests between UHPC and deformed steel rebar were carried out according to the modified RILEM test method, and were verified by finite element analysis. From the test results showed that UHPC presents 5 to 10 times higher bond strength compared to normal strength concrete, this study suggested remarkably reduced development length and concrete cover comparing to existing specifications. The test results of 700 MPa high strength steel rebar demonstrated the applicability of high strength steel to UHPC. In addition, the transfer length measurements of seven-wire strand in UHPC specimens indicated that the transfer length limit set by the current design code is very conservative for UHPC.

An Efficient Location Tracking Method for Mobile Agent Communication (이동 에이전트 통신을 위한 효율적인 위치 추적 방법)

  • Song, Sang-Hoon
    • The KIPS Transactions:PartA
    • /
    • v.11A no.5
    • /
    • pp.347-354
    • /
    • 2004
  • The provision of location tracking for mobile agents is designed to deliver a message to a moving object in a network. Most tracking methods exploit relay stations that hold location information to forward messages to a target mobile agent. In this paper, we propose an efficient location tracking method for mobile agents using the domain-based proxy as a relay station. Mobile agents can reduce the length of their migration paths by visiting hosts in the same domain first, rather than selecting hosts randomly. The proposed method exploits the domain-based moving patterns of mobile agents and minimizes registration and message delivery costs. Since the long proxy chain can contribute to the high message delivery cost, we also propose a compressing method to reduce the message delivery cost.

Proxy Chaining for Efficient Mobile Agents Communication (효율적인 이동 에이전트 통신을 위한 프록시 연결)

  • 송상훈
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10a
    • /
    • pp.19-21
    • /
    • 2004
  • 이동 에이전트에 메시지를 전달하기 위해서 이동 에이전트의 위치를 추적할 수 있는 위치 추적 기능이 필요하다. 대부분의 위치 추적 방법은 목표 이동 에이전트의 위치 정보를 이용하여 메시지를 전달하는 릴레이 노드를 이용한다. 릴레이 노드들을 구성하는 방법에 따라 메시지 전달 비용이 커지거나, 또는 위치 정보등록 비용이 커져서 비효율적이다. 본 논문에서는 도메인 기반 프록시를 이용하여 위치 정보 등록 비용을 줄이고, 프록시 체인의 길이를 압축하여 메시지 전달 비용을 더욱 줄여서 전체 비용을 최소화하는 방법을 제안한다.

  • PDF

Dynamic Behavior of Pretensioned Concrete Member during Detensioning (긴장재 절단에 따른 프리텐션 부재의 동적 거동 고찰)

  • Kim, Jangho;Mun, Do Young;Ji, Goangseup;Kim, Gyuseon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.747-756
    • /
    • 2008
  • The purpose of this paper is to investigate the effect of the important parameters on the transfer length during the dynamic flame cutting of tendon experimentally. The considered parameters were strand diameter, concrete cover thickness, stirrup, debonding strand and release method. Ten pretensioned concete beam specimens were cast and tested. Time history curves for the axial strain of tendon were measured by electrical resistance strain gauges mounted on the strands. Experimental results indicated that large dynamic shock effects occurred near cut-end during the sudden release. The prestressing forces are dependent on the parameters above considered. The ratio of residual prestressing forces of 12.7 mm strands is greater than 15.2 mm strands. Using debonding strand and gradual release are more efficient for applying prestressing forces.

An effect of length between the EUT and surge generator in surge immunity test (EUT와 서지 발생기 사이의 거리가 서지 내성 시험에 미치는 영향)

  • 이주광;임순재
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.4
    • /
    • pp.57-61
    • /
    • 1995
  • This paper reports on a theoretical and experimental study on an effect of length between the EUT and surge generator. In the case of using 40m line, surge energy was decreased to 77% of the output of surge generator.

  • PDF