• Title/Summary/Keyword: 전단시험

Search Result 1,848, Processing Time 0.024 seconds

Evaluation of Undrained Shear Strength for Clayey Silt with Low Plasticity from the West Coast (서해안 저소성 점토질 실트 지반의 비배수 전단강도 평가)

  • Kim, Seok-Jo;Lee, Sang-Duk;Kim, Ju-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.8
    • /
    • pp.15-25
    • /
    • 2016
  • In order to analyze undrained shear strength for clayey silt with low plasticity from Hwaseong site, a series of laboratory and in-situ tests were performed. The Unconfined Compressive (UC) test and Simple Consolidated-Undrained Triaxial (SCU) test were examined in order to assess their applicability to the measurement of the undrained strength of this soil. In the case of clayey silt with low plasticity, although the samples were properly taken by undisturbed sampling method, the residual effective stress and the unconfined compressive strength were reduced considerably. Therefore, an effective confining pressure that corresponds to the typical marine clay should be applied to the soil specimen before shearing in order to compensate for the loss of residual effective stress. By evaluating the shear strengths of clayey silt with low plasticity as 75% of $s_{u(scu)}$, the in-situ shear strength of this kind of soil can be duplicated.

A Study of Characteristic of Friction Angles between Sand and Artificial Rock Interface by Direct Shear Test (직접전단시험에 의한 모래와 인공암석 경계면의 마찰각 특성 연구)

  • Yang, Hong-Suk;Lee, Byok-Kyu;Jang, Seung-Jin;Lee, Su-Gon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.8
    • /
    • pp.65-73
    • /
    • 2012
  • Soil-rock interface, mainly founded in Granite region of Korea, is known as one of the important factor of the slope failure at the rainfall due to smaller shear strength than soil itself. However, research of the effect on slope stability by soil-rock interfaces is insufficient. Therefore, a series of direct shear tests were performed in order to investigate the effect of soil-rock interface on slope stability. The method of tests is to get sand itself and sand-artificial rock interface shear strength from different grain size of sands and artificial rock samples. The results of tests show that the friction angle of interface depends primarily on particle size and surface roughness. Interface friction angle ratio ${\mu}(={\delta}/{\Phi})$ is in the range of 0.75 ~ 0.96, this results indicate that interface friction angle is smaller than sand itself.

The Rubber Characteristic Test for Solid Motor Flexible Seal (고체 모터 플렉시블 씰을 위한 고무 특성 시험)

  • Kim, Byung-Hun;Kwon, Tae-Hoon;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.217-220
    • /
    • 2008
  • The most important properties in the rubber for a flexible seal are the shear modulus, shear stress, reproducibility of rubber properties from lot to lot and shear modulus variation as aging. This study was conducted to confirm a rubber characteristic for the flexible seal. As a test result, the shear modulus is the range of 0.4310 ${\sim}$ 0.4997MPa, and failure shear stress is above 2.5MPa. After 1 year, the shear modulus of rubber as aging increased about 11.8%.

  • PDF

Transfer Length of the Soil Nail Induced by the Shear Deformation (전단변형에 따른 쏘일네일의 전이길이)

  • You, Min Ku;Lee, Sang Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.6
    • /
    • pp.61-73
    • /
    • 2018
  • When the shear deformation occurs on the slope reinforced with soil nail, a passive earth pressure is induced on the ground around the soil nail and the increase of shear deformation causes the earth pressure variation of the ground and the deformation and member force change of the soil nail. In this study, the shear behavior of the soil nail was analyzed experimentally by inducing the shear deformation in the vertical direction of the soil nail using a large-scale direct shear test equipment and it was verified through numerical analysis. The shear test was performed on the bonded length (6D, 8D, 10D and 12D) of the soil nail separated from the shear surface. As a result, it was observed that the continuous increase of the shear deformation caused the damage of the grout and the effect according to the bonded length was analyzed. Through the model test and the numerical analysis, it was confirmed that the transfer length of the soil nail was 0.2~0.22m, which is larger than 0.1m suggested in the previous study, and the shear zone was in the range of 0.6m from the shear surface.

Development and Calibration of a Permanent Deformation Model for Asphalt Concrete Based on Shear Properties (아스팔트 콘크리트의 전단 물성을 고려한 영구변형 모형 개발 및 보정)

  • Lee, Hyun-Jong;Baek, Jong-Eun;Li, Qiang
    • International Journal of Highway Engineering
    • /
    • v.13 no.4
    • /
    • pp.61-70
    • /
    • 2011
  • This study developed a permanent deformation model for asphalt concrete based on shear properties. Repeated load triaxial compression (RLTC), triaxial compressive strength, and indirect tension strength tests were performed for the three types of asphalt mixtures at various loading and temperature conditions to correlate shear properties of asphalt mixtures to rutting performance. For the given mixtures, as testing temperature increased, cohesion decreased, but friction angle was insensitive to temperature at $40^{\circ}C$ or higher. It was observed that deviatoric stress, confining pressure, temperature, and load frequency affected the permanent deformation of asphalt mixtures significantly. The permanent deformation model based on shear stress to strength ratio and loading time was developed using the laboratory test results and calibrated using accelerated pavement test data. The proposed model was able to predict the permanent deformation of the asphalt mixtures in a wide range of loading and temperature conditions with constant model coefficients.

Planar (Rolling) Shear Strength of Structural Panels Using 5-point Bending Test (5점 휨하중 시험법을 사용한 구조용 판넬의 굴림전단강도)

  • Oh, Sei Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.5
    • /
    • pp.425-436
    • /
    • 2018
  • This study was conducted to evaluate the planar (rolling) shear strength of OSB (oriented strand board) panels and domestic plywood through 5 point bending test method in ASTM D2718 standard. The test specimens were prepared in parallel and perpendicular direction to major axis (along the length of panels) and tested up to failure, and failure modes were also examined. From the test results, rolling shear strength were found to be $1.32{\sim}1.94N/mm^2$ in parallel to major axis, and $1.46{\sim}1.99N/mm^2$ in perpendicular to major axis respectively. Little difference was found between parallel and perpendicular direction of rolling shear strength. There were no statistically significant differences in rolling shear strength between Canadian OSB and domestic plywood in the parallel direction, and between Chilean OSB and domestic plywood in the perpendicular direction. The shear failure was observed in all tested OSB panels, whereas shear failure, glue line delamination, and bending combined with shear failure were observed in the domestic plywood.

Deformational Characteristics of Cohesive Soils Using Resonant Column / Torsional Shear Testing Equipment (공진주/비틂 전단(RC/TS)시험기를 이용한 점성토의 변형특성)

  • 김동수
    • Geotechnical Engineering
    • /
    • v.11 no.1
    • /
    • pp.113-126
    • /
    • 1995
  • Both resonant column (RC) and torsional shear(TS) tests were performed at small to intermediate strain levels to investigate deformational characteristics of cohesive soils. The effects of variables such as strain amplitude, loading frequency, and number of loading cycles were studied. Plasticity index was found to be an important variables in evaluating these effects. Soils tested include undisturbed silts and clays and compacted subgrade soils. At small strains below the elastic threshold, shear modulus is independent of number of loading cycles and strain amplitude. Small strain material damping exists wi th ranges be tween 1.1% and 1.7% for 75 tests. The elastic threshold strain increases as confining pressure and plasticity index increases. Above the cyclic threshold strain, the modulus of cohesive soil decreases with increasing number of cycles while damping ratio is almost independent of number of load cycles. Moduli and damping ratios of cohesive soils obtanined by RC test are higher than those from 75 test because of the frequency effect. Shear modulus of cohesive soil increases linearly as a function of the logarithm of loading frequency.

  • PDF

Determination of Undrained Shear Strength In Clay from Cone Pressuremeter Test (Cone Pressuremeter를 이용한 점성토의 전단 강도 산정)

  • 이장덕
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.8
    • /
    • pp.49-58
    • /
    • 2004
  • The cone pressuremeter test (CPM) is a new in-situ test which combines a standard cone penetration test with a pressuremeter. The cone pressuremeter tests in clay are presented and analyzed. An analytical solution of CPM incorporated non-linear soil behavior with no volume change is presented, and curve fitting technique is proposed to make use of both the loading and unloading portions of the pressuremeter test. The proposed method is accomplished by putting greater emphasis on the unloading portion. Twenty CPM tests are analyzed using the proposed method, and the derived undrained shear strength of soil is compared with other tests such as field vane tests and laboratory tests. The interpreted soil parameters had resonable values when compared to other in-situ and laboratory test results. The cone pressuremeter has provided reliable measures of undrained shear strength using curve fitting method.

The Stress -Strain Behavior of Sand in Torsion Shear Tests (비틀림전단시험에 의한 모래의 응력 -변형률 거동)

  • 남정만;홍원표
    • Geotechnical Engineering
    • /
    • v.9 no.4
    • /
    • pp.65-82
    • /
    • 1993
  • A series of torsion shear tests were performed to study the drained stress -strain behavior of medium dense Santa Monica Beach sand under various stress paths. The torque was applied to both clockwise and counterclockwise directions at the end of hollow cylinder specimen. Two clip gages had been previously used to measure the changes in wall thickness and diameter of the specimen. In this study, however, the lateral strain was determined by measuring volume changes in specimen. Specimens were prepared by the air pluviation method and gaseous carbon deozide( CO2) was used to measure precisely volumetric strain in specimen. The drained stress -strain behavior of cohesionless Boils during rotation of principal stress directions was analysed based on the results of torsion shear tests. The coupling of mal stress were applied. It was also found from the test results that the atrial strain at failure decreased with increasing value.

  • PDF

A Study on the Shear Resisting Effect of Filling-up Carbon Fiber Rod Plastic in Reinforced Concrete Beam without Web Reinforcement (전단보강근이 없는 철근콘크리트보의 매립형 CFRP 전단보강효과에 대한 연구)

  • Kim, Young-Sik;Park, Sung-Moo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.5 no.2 s.16
    • /
    • pp.57-63
    • /
    • 2005
  • The reinforced concrete becomes deteriorated. In strengthening of reinforced concrete structure, it is recently useing FRP. The purpose of this study is to investigate the shear resisting effort of filling-up CFRP in reinforced concrete beams without web reinforced. Six specimens were manufactured and tested. In the test result, it was analysis. The main variables in the test were a space and volume of CFRP.

  • PDF