• Title/Summary/Keyword: 전기통신시스템

Search Result 1,740, Processing Time 0.055 seconds

Verification Strategy of IEC 61850 Communication Reliability for Constructing the Substation Automation System (변전자동화시스템 구축을 위한 IEC 61850 통신신뢰성 검증 방안)

  • Lee, N.H.;Jang, B.T.;An, Y.H.;Kim, B.H.;Shin, E.B.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.231-234
    • /
    • 2009
  • IEC 61850 based substation automation system is operating under digital network with a number of IEDs and a HMI as relation of server and client. In case of IEDs, before implementing the system, all of the system integrators require IEC 61850 certificate from individual IED manufacture. Otherwise, there is nothing to verify IED for constructing substation automation system at the real substation. This paper shows verification strategy of IEC 61850 communication reliability such as association /release, report, dataset and four type control function.

  • PDF

Functional Description of D-EMS for the Stabilization of Distribution Systems with Large Penetration of Distributed Energy Resources (대용량 분산전원 연계 배전계통 안정화를 위한 D-EMS의 기능 분석)

  • Jeong, Bong-Sang;Chun, Yeong-Han;Lee, Su-Mi;Cha, Song-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.519_520
    • /
    • 2009
  • 신재생 에너지원을 포함한 대부분의 소용량 분산전원(DER : Distributed Energy Resource)은 22.9 KV 이하의 저압 배전계통에 분포하게 된다. 배전계통에 도입되는 분산전원(DER)에 의한 역조류 문제는 수용가 단의 전압상승 문제를 야기 시킬 뿐 아니라 보호계전 시스템의 전반적인 재검토를 필요로 한다. 출력 제어가 불가능한 분산전원(DER)의 도입량 증가에 따른 무효전력의 수급문제는 기존의 배전망 운영의 개념으로는 효율적인 제어가 어려우며, 유효전력의 급변에 의한 문제도 배전 지역별로 어느 정도 안정화 시킬 필요가 있다. 이를 위해서는 배전 계통운영에도 Energy Management System(D-EMS)의 도입이 필요할 것으로 사료된다. 본 논문은 D-EMS 도입 및 스마트그리드 체제로의 이행을 위한 통신네트워크의 아키텍처 수립을 위한 기능분석 결과이다.

  • PDF

How to develop overseas transmission business with Korean transmission technology (송변전 기술의 효과적인 해외시장 진출 방안)

  • Kim, Jong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.329_330
    • /
    • 2009
  • 한국전쟁의 폐허를 딛고 한세대 만에 세계최고수준의 전력 계통을 구축한 우리나라의 전력산업은 이제 성장한계에 이르러, 해외시장 진출을 통해 신성장동력을 확보하는데 주력하고 있다. 하지만 날로 치열해져 가는 국제경쟁의 틈바구니에서 세계 전력시장의 강자로 거듭나기 위해서는 전력산업의 전 분야에 걸쳐 보다 종합적이고 중장기적인 전략으로 접근하는 것이 필요하다. 한국전력의 해외사업은 1993년 발전 사업에 진출한 이래 성공적으로 확장을 거듭하고 있으나 글로벌 리더인 한국전력의 위상에 걸 맞는 시장 확보를 위해서는 발전뿐만 아니라 송변전, 배전, 통신 등 각 분야가 유기적으로 연결되어 시너지 효과를 창출해야 하고, 진출 대상국가의 전력산업 전체를 겨냥한 Total solution의 상품을 가지고 고객을 만족시킴과 동시에 수익을 극대화 해 나가야 한다. 이를 위해서는 전력계통 전체를 다루는 송변전기술을 이용한 기술마케팅을 통하여 진출대상국의 정보와 인맥을 확보한 뒤 이것을 바탕으로 리스크를 최소화 하고 수익성이 보장되는 발전 IPP사업 등 우량 사업을 개발하는 한편, 장차 그 나라의 전력시스템 전체를 한국화 해나감으로써 장기적인 시장을 확보하는 전략 아래 한국전력, 국내 전력업계 및 정부가 긴밀히 협력해 나가야 한다.

  • PDF

Remote Multi-Communication System for Networking of LED Lighting Devices (LED 조명장치의 네트워킹을 위한 원격다중통신시스템)

  • Li, Lin-Rong;Chang, Young-Hak;Lee, Jin;Ryoo, Young-Jae;Choi, Moon-Ho;Kwak, Jae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1779_1781
    • /
    • 2009
  • The main contents of this paper is to design a system that can remote control the most of the LED lighting device in the market. In order to realize the device driver, we choose the communication mode Zigbee, PLC, RS232 and RS485. Using client-server system, LED lighting device can be controlled just through web browser.

  • PDF

A Implementation of the IPTV Quality Monitoring System (IPTV 품질 모니터링 시스템 개발)

  • Shin, Jae-Heung;Lee, Sang-Ha;Lee, Sang-Chul;Kim, Byung-Jik;Cho, Chul-Su
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1897_1898
    • /
    • 2009
  • IPTV, 인터넷 전화 등 인터넷 가입자에게 제공되는 서비스가 지속적으로 증가하고 있으며, 서비스 종류의 증가와 동시에 통신 사업자가 제공하는 네트워크 속도의 향상에도 불구하고 서비스 사용자의 불만이 증가하고 있다. 이러한 불만의 원인은 인터넷을 이용하는 모든 서비스가 네트워크 자원을 공유하기 때문에 특정 서비스의 품질을 확보하지 못하는 현상의 발생에 기인한다. 따라서 인터넷 사업자의 입장에서는 인터넷을 이용하여 다양한 서비스가 이루어지지만, 해당 서비스의 품질을 확보하는 것이 중요한 과제로 등장하였다. 본 논문에서는 IPTV 서비스 환경과 유사한 실험망 환경을 구축하고, HD급 영상 데이터를 멀티캐스트스트리밍 방송 서비스를 통해 네트워크상에서 트래픽 부하에 따른 IPTV 수신영상품 질의 변화를 살펴보고, 영상품질에 따른 네트워크 측정요소의 임계치를 도출한다.

  • PDF

The CIM standards for distribution automation applications (배전 자동화 어플리케이션을 위한 CIM 표준 연구 조사)

  • Lee, Ji-Hye;Kim, Kern-Joong;Yang, Min-Uk;Lee, Jea-Won;Cho, Hwi-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.169_170
    • /
    • 2009
  • IEC 61970과 IEC 61968 시리즈에 의해 정의되는 CIM은 현재 EMS 내 어플리케이션의 모듈 통신성, transmission system electrical model들의 교환, DMS 구성 서비스를 위한 정보 교환에 적절하다. CIM은 Distribution operation에서 서로 다른 시스템을 가지는 기술적 해석 어플리케이션의 통합 과정을 촉진 시키는 데에 이용될 수 있지만, distribution network의 교환을 더욱 완벽하게 가능하게 하기 위한 모델 개선이 필요하다.

  • PDF

Synchronization of Chaotic Secure Communication Systems with Interval Time-varying Delays (구간 시변 지연이 존재하는 카오스 보안 통신시스템의 동기화)

  • Kwon, Oh-Min;Park, Ju-Hyun;Lee, Sang-Moon;Park, Myeong-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1215-1222
    • /
    • 2009
  • In this paper, a method of designing a controller which ensures the synchronization between the transmission and the reception ends of chaotic secure communication systems with interval time-varying delays is proposed. To increase communication security, the transmitted message is encrypted with the techniques of N-shift cipher and public key. And to reduce the conservatism of the stabilization criterion for error dynamic system obtained from the transmitter and receiver, a new Lyapunov-functional and bounding technique are proposed. Through a numerical example, the effectiveness of the proposed method is shown in the chaotic secure communication system.

High Order Template Scheme for Rapid Acquisition in the UWB Communication System (고차 모델을 사용한 광대역 통신 시스템의 새로운 고속 동기화 기법)

  • Baasantseren, Gansuren;Lin, Xiaoju;Lee, Hae-Kee;Kim, Sung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.47-52
    • /
    • 2010
  • The low power of ultra-wideband (UWB) signal makes the acquisition of UWB signal be a more challenging task. In this paper, we propose the method of high order template signal technique that reduces the synchronization time. Experimental results are presented to show the improvements of performance in the mean acquisition time (MAT) and the probability of detection. The performance compared with the serial search, the truly random search and the random permutation search. It is shown that over typical UWB multipath channels, a random permutation search scheme may yield lower MAT than serial search.

Zigbee Based Wireless Respiration Monitor System (지그비 통신 기반의 근거리 무선 호흡모니터 시스템)

  • Lee, In-Kwang;Kim, Seong-Sik;Jang, Jong-Chan;Kim, Koon-Jin;Kim, Kyung-Ah;Lee, Tae-Soo;Cha, Eun-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.142-147
    • /
    • 2008
  • Abdominal circumference changes due to breathing by the respiratory muscle activity such as diaphragm, which would partially represent the lung volume variation. The present study introduced conductive rubber molded in a cord shape incorporated with a patient's pants. The conductive rubber cord operated as a displacement transducer to measure the lung or abdominal volume changes. Signal extraction circuitry was developed to obtain the volume and its derivative(or the flow) signals followed by wireless transmission based on the Zigbee communication protocol in a size of $65mm{\times}105mm$ easily put in pocket. Breathing frequency was accurately evaluated and breath pattern analysis seemed feasible, since respiratory behaviours such as maximal inspiration and cough were well identified. Remote wireless receiver module also enabled to monitor both volume and flow signals during resting breathing on a PC terminal.

Traffic Test Method for Networked Control System (네트워크 기반 제어시스템의 통신부하 시험방법)

  • Yu, Kwang-Myung;Kim, Jong-An;Ryu, Ho-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.5
    • /
    • pp.688-695
    • /
    • 2013
  • Networked Control Systems(NCS) contain the structure which controllers, actuators and sensors are connected to communication network. And they have been adopted in large and complicated plant area due to the advantages of mitigating computational bottleneck and maintenance. Although this structure provides many benefits, it brings in problems of unpredictable communication delay, data loss and corruption. This phenomena have to be considered in designing NCSs since it affects on overall control system stability. This paper introduces network traffic test method for ethernet based NCSs to find out maximum network usage which guarantee stable control operation. Test results shows this methods can be adopted in various types of NCSs and contributes economical system design and effective system operation.