• Title/Summary/Keyword: 전기추진 시스템

Search Result 456, Processing Time 0.031 seconds

A Study on the Characteristics of Shaft Electric Motive Force of Controllable Pitch Propeller - Focusing on the M/V Segero - (가변피치 프로펠러의 축기전력 특성에 관한 연구 - 세계로호를 중심으로 -)

  • Park, Kyung-Min;Im, Myeong-Hwan;Choe, Sang-Bom;Ahn, Byong-Won
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.1
    • /
    • pp.135-140
    • /
    • 2022
  • Most machines are made of several types of . In particular, the shaft system of the ship consists of the brass of the propeller blade and the stainless steel of the shaft. When dissimilar the electrolyte solution of seawater, a voltaic cell and a shaft electromotive force is generated. This electromotive force causes electrical corrosion of the bearing and shaft supporting the shaft system. prevent this corrosion, a shaft grounding system is installed in ships. As for the experimental method, various information acquired by designing a program to periodically measure the electromotive force of the controllable pitchpropeller) system using an A/D converter of NI. This study analyzed the generation and characteristics of accumulator electromotive force for CPP and considered the installation location of the grounding system to remove the accumulator electromotive force.

Design and Characteristic Analysis of Hybrid-Type Levitation and Propulsion Device for High-Speed Maglev Vehicle (초고속 자기부상열차를 위한 하이브리드형 부상 추진 시스템의 설계 및 특성해석)

  • Cho, Han-Wook;Kim, Chang-Hyun;Han, Hyung-Suk;Lee, Jong-Min;Kim, Bong-Sup;Kim, Dong-Sung;Lee, Young-Sin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.715-721
    • /
    • 2010
  • This paper deals with the design and characteristic analysis of electro-magnet/permanent-magnet (EM-PM) hybrid levitation and propulsion device for high-speed magnetically levitated (maglev) vehicle. The machine requires PMs with high coercive force in order to levitate the vehicle by only PMs, and propulsion force is supplied by long-stator linear synchronous motor (LSM). The advantages of this configuration are an increasing levitation airgap length and decreasing total weight of the vehicle, because of the zero-power levitation control. Several design considerations such as machine structure, manufacturing, and control strategy are described. Moreover, the levitation and propulsion device for high-speed maglev vehicle has been designed and analyzed usign the electromagnetic circuit and FE analysis. In order to verify the design scheme and feasibility of maglev application, 3-DOF static force test set is implemented and tested. The obtained experimental data using the static tester shows the validity of the design and analysis approaches.

The Utilization Evolution of EMS Network Analysis for Optimal Power System Operation (전력계통 최적운영을 위한 EMS 계통해석 활용 진화)

  • Kang, Hyung-Koo;Kim, Tae-Eon;Kim, Kwang-Ho;Choi, Young-Min;Lee, Gun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.20_21
    • /
    • 2009
  • 전력거래소는 국내 유일하게 한국의 전력계통을 실시간으로 감시 제어하고, 계통의 안전성을 평가 후 최적으로 운용하기 위해 2002년부터 현 EMS 시스템을 운용해 오고 있다. 초기 모든 계통해석의 근간이 되는 상태추정의 운용을 위해 계통모델과 필요 취득 데이터를 대폭 정비하였다. 현재는 154kV 무인 변전소의 탭을 추가취득 하고 모든 아날로그 취득데이터의 그룹별 가중치 조정에 의한 상태추정 등 계통해석의 정도개선 노력을 지속적으로 추진해오고 있다. 또한 상정고장 개소와 발변전소 3상 단락 고장 개소를 대폭 확대 정비하여 예상되는 모든 고장에 급전원이 신속히 대처할 수 있도록 하였다. 또한 무효전력 제어를 통한 계통손실 최소화 방안의 합리적 도출을 위한 최적화 기능의 실시간 계통운용 등 괄목한 성과를 거두었다. 본고에서는 이들 EMS 계통해석 기능을 중심으로 현재의 활용실태와 미래의 방향에 대하여 소개하고자 한다.

  • PDF

An Analysis of the Comparison for a Trend on the Interior Lighting Design of High-rise Office Buildings Between Overseas and Domestic (국내.외 초고층 오피스건축물의 조명설계 경향 비교 분식)

  • Jeong, Keun-Young;Hong, Seong-Kwon;Chol, An-Seop;Lee, Jeong-Ho;Mistrick, Richard
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.42-50
    • /
    • 2008
  • There are many plans of the high-rise buildings these days in domestic and will be constructed from now on. It is required to develop energy saving techniques immediately because the high-rise buildings consume a lot of energy. The most effective energy savings method is the application of the efficient lighting designs and fixtures. The purpose of this study is to analyze a trend of lighting design, fixture and control system between overseas and domestic. It can be used the guide line for the high-rise buildings in domestic application.

A Fault Diagnosis Using System Matrix In Expert System (System matrix를 사용한 고장진단 전문가 시스템)

  • Sim, K.J.;Kim, K.J.;Ha, W.K.;Chu, J.B.;Oh, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.233-236
    • /
    • 1989
  • This paper deals with the expert system using network configuration and input information composed of protective relays and tripped circuit breakers. This system has knowlegebase independent on network dimension because network representation consists of the type of the matrix. Therefore, the knowlege of network representation is simplified, the space of knowlege is reduced, the addition of facts to the knowlege is easy and the expansion of facts is possible. In this paper, the network representation is defined to system matrix. This expert system based on the system matrix diagnoses normal, abnormal operations of protective devices as well as possible fault sections. The brach and bound search technique is used: breadth first technique mixed with depth first technique of primitive PROLOG search technique. This system will be used for real time operations. This expert system obtaines the solution using the pattern matching in working memory without no listing approach for rule control. This paper is written in PROLOG, the A.I. language.

  • PDF

Implementation of Highly Integrated Total Energy System (전력수급 종합시스템 현장적용)

  • Park, Si-Woo;Yoon, Yong-Beum;Nam, Jae-Hyun;Choo, Jin-Boo;Choi, Bong-Soo;Lee, Hyo-Sang;Kim, Joon-Hwan;Lyu, Sung-Ho;Han, Seung-Goo;Baek, Woong-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1525-1525
    • /
    • 1999
  • The main purpose of HITES(Highly Integrated Total Energy System) is to build and develop an integrated energy system for power system operational planning and analysis which consists of load forecast, economic generation schedule, stability analysis and relational database system. The HITES can be utilized to supply a stable electric power and operate KEPCO's power system facilities economically. This system was put into operation in 1999. This paper describes the main feature of the HITES, main functions, numerical methods adopted in this system and network configuration.

  • PDF

The 3 Step Expansion Strategy and Configuration of Smart Grid Station (스마트그리드 스테이션의 구성과 3단계 확산 전략)

  • Kim, Kun-Sung;Hwang, Woohyun;Yang, Chung-Ho;Geum, Dong-Jin;Kim, Suk-Cheol;Lee, Jung-ho;Seo, Jung-il
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.35-36
    • /
    • 2015
  • 21세기 들어 지구온난화 현상이 심각해지면서 세계 각국의 온실가스 감축 노력이 추진되고 있다. 특히, 2005년 2월에 공식 발효한 교통의정서(Kyoto Protocol)에서 온실가스 배출에 실질적인 책임이 있는 38개 선진국을 대상으로, 2012년까지 1990년의 온실가스 배출량 대비 평균 5.2%의 감축을 의무화 한 것이다. 한국 정부 또한 2009년 11월 온실 가스 감축목표를 2020년 배출전망치(BAU : Business As Usual) 대비 30%로 결정하고 저탄소 녹색성장기본법에 명시하는 등 국제적 감축 행렬에 동참하였다. 한국 정부는 2009년 12월부터 2013년 5월까지 42개월간 제주도에서 스마트그리드 실증사업을 시행하였다. 본 논문에서는 제주 실증단지에서 개발된 기술을 이용하여 건물단위 에너지 통합관리를 할 수 있는 시스템으로서 스마트그리드 스테이션을 개발하여 현장에 적용하였고 이를 활용한 확산방안을 제시하고자 한다.

  • PDF

Development of Monitoring for secondary-battery-system using LabVIEW (LabVIEW를 이용한 2차전지의 상태 감시제어장치에 관한 연구)

  • Kim, Sun-Young;Sin, Kun;Kim, Byung-Mok;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.85-88
    • /
    • 2011
  • 석유 등 화석연료로 인한 지구온난화 문제와 더불어 일본 대지진 이후 원자력발전의 안전에 의문이 제기 되면서 신재생에너지에 대한 관심이 한층 고조되고 있다. 이에 발맞추어 국가정책으로 녹색성장 정책이 실행됨에 따라 2030년까지 전체 에너지원 중 신에너지전원의 비중을 전체 에너지원의 11%로 확대하는 정책을 적극적으로 추진하고 있다. 따라서 신재생에너지를 통하여 얻은 전기에너지를 저장하여 사용 할 수 있는 2차 전지에 대한 연구가 다수의 산업 현장에서 각광을 받고 있다. 최근 2차 전지는 Smart Grid 및 전기자동차분야에서 폭넓게 사용 되면서 정확한 출력전압, SOC 및 충-방전 예상 시간을 추정하여 2차 전지의 과충전, 과방전으로 인하여 생기는 고장 및 사고를 미연에 방지하고 2차 전지 사용 시 편의성을 제공하기 위한 시스템에 대한 연구가 필요한 실정이다. 본 논문은 이런 실정에 맞추어 LabVIEW 프로그램을 활용하여 2차 전지의 상태를 실시간으로 감시 및 제어하는 프로그램을 제작함으로써, 사고 시 2차 전지에 가해지는 피해 방지 및 관리 시 발생하는 여러 문제점에 대한 효율적인 해결 방안을 제시하고자 한다.

  • PDF

Analysis of the Data Reliability for the Preventive Diagnostic System (예방진단시스템의 데이터 신뢰성 분석)

  • Kweon, Dong-Jin;Chin, Sang-Bum;Kwak, Joo-Sik;Woo, Jung-Wook;Choo, Jin-Boo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.2
    • /
    • pp.94-100
    • /
    • 2005
  • Abnormal symptoms on operating conditions of power transformer are monitored by a preventive diagnostic system which prevents the sudden power failure in case of quick progress of abnormal situation. The preventive diagnostic system helps plan the proper maintenance method according to the transformer conditions via accumulated data. KEPCO has adopted the preventive diagnostic system at nine of 345kV substations since 1997. Application techniques of the diagnostic sensors were settled, but diagnostic algorithm and practical use of accumulated data are not yet established. To build up the diagnostic algorithm and effective use of the preventive diagnostic system, the reliability of the data which were accumulated in a server computer is very important. This paper describes the data analysis in the server in order to advance the reliability of the accumulated data of the preventive diagnostic system. The principles and data flows of the diagnostic sensors were analyzed, and the data discrepancy between sensors and server were calibrated.

A Practical Tuning Method of Dual-Input PSS and its Application to Large Power System (다중-입력 PSS의 실제적인 튜닝 방법과 대형 전력 시스템에의 적용)

  • Kim, Dong-Joon;Moon, Young-Hwan;Hur, Jin;Shin, Jeong-Hoon;Kim, Tae-Kyun;Choo, Jin-Boo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.7
    • /
    • pp.362-370
    • /
    • 2002
  • This paper describes the practical tuning method of dual-input PSS and its application to Muju P/P #2 with Proto PSS, which is based on DSP technology and uses both frequency and power. First, the model parameters of generator system used in this paper have been derived from the generator characteristic testing. Then, in the selection of PSS parameters, the Bode plot is plotted in order to tune the PSS's time constants which are able to compensate the phase lagging due to generator and excitation system. In addition, the eigenvalue analysis is also performed for determining a reliable PSS gain, $K_{s}$. Finally, the transient stability program has been utilized to verify the safe operation of Proto PSS against the predictable disturbances such as the AVR-step test and generator unloading test. In on-site test, the simulated results have been identically duplicated by implementing AVR step test in Muju P/P #2 with Proto PSS, which has the previously designed PSS parameters.s.