• Title/Summary/Keyword: 전기저항성

Search Result 1,801, Processing Time 0.031 seconds

Electrical Resistance Measurement in Characterizing the Internal Damage of Carbon Nanotube/Polypropylene Nanocomposites (전기저항 측정법을 이용한 탄소나노튜브/폴리프로필렌 나노복합재료의 내부 손상 예측)

  • Kim, Hak-Soo;Kwon, Dong-Jun;Wang, Zuo-Jia;Gu, Ga-Young;Kim, Dae-Sik;Lee, Chun-Soo;Park, Joung-Man
    • Composites Research
    • /
    • v.26 no.3
    • /
    • pp.201-206
    • /
    • 2013
  • The electrical resistance measurement was investigated as a damage monitoring method. In this study, 0.5 wt% Carbon nanotube reinforced polypropylene (CNT/PP) composites were evaluated under compressive fatigue loading. The shape of specimens was $20^{\circ}$ curved round type. Compression strength and electrical resistance were measured at different sections of specimen during compression. The microcracks of CNT/PP composites were detected based on the changing ratio of electrical resistance. Micro-damage during compressive fatigue test could be detected by electrical resistance measurements. The reason is that the contact points of CNTs in composites decreased under fatigue loading. During compressive fatigue test, larger change of electrical resistance was detected at the microcrack sections. It was proved that microcracks could be detected by electrical resistance measurement under compression test, whereas the real delamination parts were consistent with the predicted results by electrical resistance measurement.

A Development of Sheet Resistance Meter for Thin Film Materials (박막 재료의 면저항 측정기 개발)

  • Kang, Jeon-Hong;Yu, Kwang-Min;Kim, Han-Jun;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.233-234
    • /
    • 2009
  • 박막 재료의 면저항 측정은 일반적으로 FPP(Four-Point Probe)원리를 적용한 측정기률 사용하고 있다. 개발된 면저항 측정기의 특징은 dual configuration 기술을 적용하여 탐침 간격에 대한 시료의 크기 및 두께에 대한 보정계수를 고려하지 않아도 되므로 누구나 업고 정확하게 사용 할 수 있다. 측정범위는 $1\;m{\Omega}{/\square}\;{\sim}\;1\;G{\Omega}{/\square}$이며, 반복성과 재현성 및 직선성은 0.1 %이하로서 우수한 특성을 나타냈다. 또한 기존의 면저항 측정기에 적용된 single configuration 기술에서 나타나는 가장자리 효과의 단점을 dual configuration 기술을 적용하여 해결하였고 정밀 정확도를 향상시켰다. 개발된 면저항 측정기의 특성평가는 국가측정표준으로부터 소급성이 유지된 표준저항, 분할저항기, 면저항 인증표준물질 등을 사용하였다.

  • PDF

765kV 심형기초 철탑의 정상 접지저항

  • Han, Pung;Choi, Jong-Gi;Chung, Gil-Jo;Kim, Jeong-Bu
    • 전기의세계
    • /
    • v.46 no.9
    • /
    • pp.36-46
    • /
    • 1997
  • 본 해설에서는 철탑의 과도 접지저항은 물론 정상 접지저항의 측정과 관리에 대한 필요성을 강조하며, 일차적으로 765kV 심형기초 철탑의 정상 접지저항의 계산 및 측정에 관하여 설명한다.

  • PDF

Application of Electrical Resistivity Tomography to Analyze Soil Properties in Unsaturated Bone (불포화대 토양 특성 분석을 위한 전기비저항 토모그래피의 적용성)

  • Yong Hwan-Ho;Song Sung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.3
    • /
    • pp.184-190
    • /
    • 2004
  • To analyze soil properties of unsaturated zone, we applied electrical resistivity tomography(ERT) of high resolution image. From linear relationship with each soil texture between results of ERT and soil properties such as electrical conductivity of pore water, water contents and ionic contents, we could be analyzed the result of ERT more effectively. Consequently, ERT can be useful for estimating soil properties between the two holes and evaluating indirectly pH and organic contents of soil.

The Influence of Bonding Parameters on the Contact Resistance, Adhesion and Reliability of Anisotropically Conductive Film(ACF) (이방성 전도 필름의 접촉 저항, 접착력 및 신뢰성에 미치는 접속 변수의 영향)

  • Im, Myeong-Jin;Baek, Gyeong-Uk
    • Korean Journal of Materials Research
    • /
    • v.8 no.5
    • /
    • pp.399-407
    • /
    • 1998
  • 본 연구에서는 LCD패키지용 이방성 전도 필름의 전기적, 기계적 특성 및 신뢰성에 미치는 접속 변수의 영향을 연구하였다. 이방성 전도 필름을 통한 전기적 전도 현상을 각각의 도전 입자와 기판 사이의 기계적 접촉에 의해 접촉 방향으로만 전류가 흐르게 되는 것이 주되는 전도 기구이다. 따라서 접속 압력에 따라 각각의 도전 입자의 변형으로 기판 사이의 접촉 면적이 변하는데 이방성 전도필름의 접촉 저항은 이런 접촉 변화에 의해 결정된다. 접속 압력에 따라 초기에 접촉 저항은 감소하다가 점차 접촉 저항기가 안정화되는 거동을 보였다. 그러나 높은 접속 압력에서는 오히려 저항치가 약간 증가함을 보였다. 이방성 전도 필름 접속의 접착력을 평가하기 위해 필 테스트(peel test)를 시행하였는데, 접속 압력과 접속 온도를 증가 시킬수록 이방성 전도 필름 접속의 접착력을 평가하기 위해 고온 시효 시험, 온도 사이클링 시험, 고온 고습 시험의 신뢰성 시험을 시행하였으며, 이중 고온 고습 시험이 ACF접속의 전기적, 기계적 특성에 가장 악영향을 주었다. 또 큰 압력으로 접속된 것보다 작은 압력으로 접속되었을 때, 그리고 도전입자로는 금속 코팅 된 폴리머 입자가 사용될 때 신뢰성이 상대적으로 좋은 것을 발견했다.

  • PDF

Study on the Photoimageable Resin Composition for Polymer Thick Film Resistor Paste (폴리머 후막 저항 페이스트용 Photoimageable Resin 조성 연구)

  • Park, Seong-Dae;Park, Se-Hun;Yoo, Myong-Jae;Lee, Sang-Myung;Kang, Nam-Kee;Lim, Jin-Kyu;Kim, Dong-Kook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.228-229
    • /
    • 2006
  • 본 연구에서는 PCB에 적용하기 위한 폴리머 타입 후막저항의 하나로서, 포토공정으로 저항 패턴의 형성이 가능한 페이스트를 제조하였다. 기존의 폴리머 후막저항은 스크린 인쇄를 패터닝의 주요 방법으로 하고 있어 패턴의 정밀성이 떨어지는 단점이 있었다. 이를 개선하여 고정밀 저항 패턴의 형성이 가능하도록 Photoimageable Resin을 저항 페이스트의 개발에 도입하였다. Acrylated oligomer 및 monomer, 그리고 Novolac Epoxy를 주 기지상 재료로서 사용하였으며, acrylate와 epoxy의 함량비에 따른 저항 페이스트의 현상성 및 시트저항을 평가하였다. 전도성 Filler 재료로 카본블랙을 이용하였는데, 그 물리적 특성차와 함량이 저항 페이스트의 현상성과 저항값에 미치는 영향을 평가하였다. 실험결과 Acrylate와 epoxy의 비가 2.5:1일 때 현상성이 가장 양호하였으며, 이 조성에 XC72R 카본블랙을 2g 첨가하였을 때 시트저항의 평균값은 약 $6\;k{\Omega}\{\square}$였다.

  • PDF

Applicability of Resistivity/Capacitance Measurement on CPT Module for Investigation of Subsurface Contamination (지반 오염도 조사를 위한 전기비저항/정전용량 측정콘의 적용성 평가)

  • Oh, Myoung-Hak;Kim, Yong-Sung;Park, Jun-Boum
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.7
    • /
    • pp.45-54
    • /
    • 2006
  • Resistivity cone penetrometer test (RCPT) can be employed at a relatively low cost for in-situ delineation of subsurface contamination. While the resistivity measurement has a potential to investigate the subsurface contamination, resistivity measurements alone will lead to some degree of ambiguity in the results. In this study, capacitance measurement was incorporated into the RCPT to overcome the ambiguity inherent in electrical resistivity measurements. This study is focused on verifying the applicability of resistivity and capacitance measurements of CPT module to provide information on subsurface contaminated by heavy metal and petroleum hydrocarbon. Laboratory model tests were performed to evaluate the sensitivity of the measured resistivity and relative capacitance on the water content and different types of contaminants. Test results show that simultaneous measurement of electrical resistivity and capacitance can give more reliable information on subsurface contamination. Electrical measurements of the CPT module showed high applicability to be used in detecting saturated soils contaminated by heavy metal and diesel plume floating above the groundwater table.

Effect of Types of Accelerators and Replacement Levels of GGBFS on the Performance of Shotcrete Mortars (숏크리트 모르타르의 성능에 대한 급결제 종류 및 고로슬래그 미분말 대체율의 영향)

  • Lee, Seung Tae;Kim, Seong Soo;Kim, Dong Gyu;Park, Kwang Pil
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.1
    • /
    • pp.76-84
    • /
    • 2013
  • In this study, some engineering properties of OPC and GGBFS shotcrete mortars with alkali-free or aluminate accelerator were experimentally examined. As a result, GGBFS mortars with alkali-free accelerator were significantly similar to OPC mortars with same accelerator with respect to both setting time and compressive strength. Comparatively, GGBFS mortars with aluminate accelerator showed a good performance with an increased replacement of GGBFS. Furthermore, when replaced with GGBFS over 50%, the mortars exhibited superior performances of electrical resistivity and chloride ions penetration resistance. Accordingly, it is suggested that GGBFS has a beneficial effect as shotcreting materials in the condition of proper replacement levels.

An Application of Electrical Resistance Method for Monitoring of Rotating Cylindrical Separator (원통형 회전 분리기를 감시하기 위한 전기저항법의 이용)

  • Lee, Bo-An;Kim, Sin
    • Journal of Energy Engineering
    • /
    • v.20 no.1
    • /
    • pp.21-25
    • /
    • 2011
  • In order to monitor a rotating cylindrical separator for radioactive waste, an electrical resistance method is proposed and its mathematical model is investigated. In a rotating radioactive waste separator, the electrical resistance between a pair of electrodes mounted on the inner wall of the vessel is related to the thickness of annular region of insoluble particle formed around the periphery and the concentration of the insoluble particle in that region. This work presents an analytical relationship among the aforementioned parameters based on a two-dimensional solution to the electrical potential equation and an empirical conductivity-concentration relation. Also, the feasibility of electrical resistance method for monitoring rotating cylindrical separators is discussed.

Ag Grid를 이용한 플렉시블 투명 전극의 투명 안테나 특성 연구

  • Jo, Chung-Gi;Kim, Han-Gi
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.27.2-27.2
    • /
    • 2011
  • 본 연구에서는 저저항/고투과 플렉시블 투명 전극 개발을 위해 금속 그리드가 적용된 투명 전극을 개발하였다. Lift off 공정을 도입하여 플렉시블 PET 기판 위에 Ag grid를 성막하고 이후 연속 공정이 가능한 Roll-to-Roll sputtering system을 이용하여 최적화된 ITO(40nm)/Ag(12nm)/ITO(40nm) 다층 투명 전극을 성막하였다. 제작된 플렉시블 투명 전극의 전기적, 광학적, 구조적 특성 및 기계적/전기적 안정성 평가를 위해 four-point probe measurement, Hall effect measurement, UV/Vis spectrometer, scanning electron microscopy 및 bending tester를 이용하여 각각의 특성을 분석하였다. Ag grid가 적용된 ITO/Ag/ITO 투명 전극에서 Ag의 배선 간격이 0.75 mm일 때 0.18 ohm/sq. 의 낮은 면 저항과 가시광선 영역에서 80% 이상의 높은 투과율을 나타내었으며, 이러한 저저항 및 고투과율 특성으로 인해 최적화된 배선 간격 0.75 mm에서 $538.11{\times}10^{-3}\;ohm^{-1}$의 매우 높은 figure of merit ($T^{10}/R_{sh}$) 값을 확보할 수 있었다. 기계적 응력에 따른 전기적 안정성 특성 분석 결과 5,000회 이상의 bending cycle 에서도 초기 저항 값과 유사한 전기적 특성을 나타냄으로써 Ag grid가 적용된 ITO/Ag/ITO 플렉시블 투명 전극의 기계적 응력에 따른 전기적 안정성을 확인할 수 있었다. Ag grid가 적용된 ITO/Ag/ITO 투명 전극의 투명 안테나 적용 가능성을 타진하기 위해 low band 및 high band 영역에서의 안테나 효율을 측정하였으며, 모든 영역에서 상용화된 copper 안테나와 유사한 효율을 나타내었다. Ag grid를 이용한 플렉시블 투명 전극의 저저항/고투과율 특성은 플렉시블 광전소자의 투명 안테나로의 적용 가능성을 나타낸다.

  • PDF