• Title/Summary/Keyword: 전극모델

Search Result 254, Processing Time 0.025 seconds

Computation of Critical Length for Linear Grounding Electrodes (직선형 접지전극의 임계길이의 산정)

  • Kim, Ki-Bok;Lee, Bok-Hee;Joe, Jeong-Hyeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.67-74
    • /
    • 2009
  • For the surge currents like lightning currents containing high frequency components and the abnormal currents having high frequencies which cause the EMI(Electromagnetic interference) problems for the electronic devices and communication instruments, the linear grounding electrodes have the significantly composite impedance characteristics which are dependent on the frequency of the applied current. The impedance of a grounding electrode is not lowered by expanding the dimension of the grounding electrode, and the length of grounding electrode having the minimum value of the grounding impedance for each condition of frequency and soil characteristics is existent, and it is defined as Critical length. In this paper, the critical lengths for the vertically and horizontally-buried grounding electrodes are calculated by using the distributed parameter circuit model. The propriety of the simulations has been confirmed by comparing the simulated results with the measured results.

Characteristic Analysis of Cyclic Voltammetry on a Self-Assembled Mono-layer Electrode (자가조립 단층 전극에 대한 순환전위법의 특성해석)

  • Cho, Hana;Yoon, Do-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.4
    • /
    • pp.217-224
    • /
    • 2013
  • In this paper, we have investigated the characteristics of cyclic voltammetry of a self-assembled mono-layer(SAM) electrode which was modified by 3-Mercaptopropionic acid (3-MPA) on gold nanoparticle(AuNP)-deposited electrode. Also, the transport phenomena of electrons and ions around the electrode have been analyzed. The governing equation and its boundary conditions by adopting the semi-infinite diffusion model were formulated for the mass-transfer dominant system. In order to obtain the numerical solutions of cyclic voltammetry(CV) on SAM electrodes, MATLAB program was implemented by applying the explicit finite difference method. Resulting CV program for the SAM-modified electrode was verified in good agreements with the experimental CV results for the 3-MPA on AuNP electrode.

Development of a Circuit Model for the Dynamic Plasma Load in a PSII Pulse System (PSII 펄스 시스템의 동적 플라즈마 부하 회로 모델 개발)

  • Chung, K.J.;Choe, J.M.;Hwang, H.D.;Kim, G.H.;Ko, K.C.;Hwang, Y.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.3
    • /
    • pp.246-258
    • /
    • 2006
  • A circuit model has been developed to analyze characteristics of the PSII(plasma source ion implantation) pulse system with dynamic plasma load. The plasma sheath in front of the immersed planar target biased with a negative-high voltage pulse is assumed to be governed by the dynamic Child-Langmuir sheath model. Target current is self-consistently varied with the applied voltage by using the voltage-controlled current source in the circuit model. Circuit simulations are conducted with Pspice circuit simulator, and simulated pulse currents and voltages on the target are compared and confirmed with experimental results for various voltage pulses and plasma conditions.

A Study on the Characteristics of Four Electrode Bioimpedance Model using Dry Electrode (건식전극을 이용한 4 전극형 생체임피던스 모델 특성 연구)

  • Cho, Young Chang;Jeong, Jong Hyeong;Yun, Jeong-oh;Kim, Min Soo
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1122-1127
    • /
    • 2019
  • In this study, the bio-impedance of the human body is able to obtain a lot of information by monitoring the pathological and physiological conditions of clinical and biological tissues. The four electrode method system for biometrics measured the potential difference between two electrodes and the other two electrodes were used as electrodes for current flow. The newly developed dry gold electrode measured impedance from 1 Hz to 50 kHz and produced reproducible results. To verify the impedance measurement of the dry electrode, the pitting was performed using an equivalent circuit model of the bioelectrode skin, and the effectiveness was demonstrated through modeling. Fixed electrode types have a constant position of the electrodes attached during the measurement, so that a stable measurement can be obtained, thereby minimizing the error.

Modeling of High-throughput Uranium Electrorefiner and Validation for Different Electrode Configuration (고효율 우라늄 전해정련장치 모델링 및 전극 구성에 대한 검증)

  • Kim, Young Min;Kim, Dae Young;Yoo, Bung Uk;Jang, Jun Hyuk;Lee, Sung Jai;Park, Sung Bin;Lee, Han soo;Lee, Jong Hyeon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.4
    • /
    • pp.321-332
    • /
    • 2017
  • In order to build a general model of a high-throughput uranium electrorefining process according to the electrode configuration, numerical analysis was conducted using the COMSOL Multiphysics V5.3 electrodeposition module with Ordinary Differential Equation (ODE) interfaces. The generated model was validated by comparing a current density-potential curve according to the distance between the anode and cathode and the electrode array, using a lab-scale (1kg U/day) multi-electrode electrorefiner made by the Korea Atomic Energy Research Institute (KAERI). The operating temperature was $500^{\circ}C$ and LiCl-KCl eutectic with 3.5wt% $UCl_3$ was used for molten salt. The efficiency of the uranium electrorefining apparatus was improved by lowering the cell potential as the distance between the electrodes decreased and the anode/cathode area ratio increased. This approach will be useful for constructing database for safety design of high throughput spent nuclear fuel electrorefiners.

Changes in Heating Profiles of Apple Juice by Ohmic Heating (통전가열(Ohmic Heating) 처리조건에 따른 사과주스의 가열속도 변화)

  • Kim, Kyung-Tack;Choi, Hee-Don;Kim, Sung-Soo;Hong, Hee-Do
    • Applied Biological Chemistry
    • /
    • v.41 no.6
    • /
    • pp.431-436
    • /
    • 1998
  • The optimum ohmic heating condition of apple juice was investigated with model solution. The temperature rise of model solution was found to be $7.8,\;21.0,\;47.4^{\circ}C/min$ when the distances between electrodes were 29, 22, and 17mm, respectively. The heating rate increased proportionally with the numbers of electrode pairs, 1 to 3 and highly dependent on applied voltage. The heating rate was not affected by the frequencies ranged from 60 Hz to 60 KHz and the wave form of applied alternating electric current. The apple juices prepared by ohmic heating sterilization revealed similar physicochemical properties to that by commercial sterilization.

  • PDF

Design and fabrication of Rotary Microactuator Using SEA(Skewed Electrode Actuator) (SEA(Skewed Electrode Actuator)를 이용한 회전형 마이크로 액츄에이터의 설계 및 제작)

  • Choi, Seok-Moon;Hwang, Eun-Su;Cho, Dong-Woo;Kim, Young-Jun;Lee, Sang-Jo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.65-68
    • /
    • 2001
  • 본 연구에서는 코움 드라이브에 비해 구동력은 크고 평행 판 구동 방식에 비해서는 선형 특성이 우수하며 안정된 구동거리가 증가하는 특성을 갖는 새로운 정전력(electrostatic force) 구동 방식을 제안한다. 운동 전극과 고정 전극을 기울어지게 배치하여 전극 면에 평행한 정전력 $F_x$와 전극 면에 수직인 정전력 $F_y$의 합력 $F_e$ 방향으로 전극을 운동시킴으로써 정전력의 방향과 전극의 운동 방향을 일치시킨다. 제안된 구동방식의 정전력 모델을 이용한 해석 결과 코움 드라이브에 비해서는 구동력이 50 % 이상 크며 평행 판 구동에 비해서는 안정된 구동 거리가 10 - 30 % 이상 증가하는 구동 특성을 얻을 수 있었다. 제안된 구동방식을 이용하여 HDD의 트랙 방향 저장 밀도를 증가시키기 위한 듀얼스테이지 서보(dual-stage servo)에 사용 될 마이크로 액츄에이터 (microactuator)를 설계하고 SoG(Silicon on Glass) 공정을 이용하여 제작하였다.

  • PDF

Evaluation of the Cochlear Electrode Behavior in the 3D Human Cochlea Model by FEM Analysis (3차원 달팽이관 모델에서의 인공와우 전극의 거동에 대한 유한요소해석)

  • 임윤섭;박세익;김용협;오승하;김성준
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.207-215
    • /
    • 2004
  • A finite element analysis is used in this study to model 6 kinds of electrode by a genetic program in order to evaluate the mechanical effect on the 3D human cochlea model and the behavior of electrode. Human cochlea is modeled by the spiral-approximation method and the shape of scala tympani is extracted from the mid section of the human cochlea. Contact pressure at the tip and the insertion force are found to be highest when the wires stack horizontally. Axial rotation of electrode is minimal comparing with the stimulating current spread. The results indicate that the electrode stiffness is important to minimize the trauma.

Current of planar switch during the recovering time of the negative pulse (음펄스 전압회복에 따른 평판형 스위치 전극에 흐르는 전류의 거동 관찰)

  • Hwang, Hui-Dong;Choe, James;Ko, Kwang-Cheol;Kim, Gon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.120-122
    • /
    • 2004
  • 평판 스위치 전극에 인가되는 전압 변화에 따라서 전극 앞에서의 플라즈마 전위의 변화를 측정하고, 이를 이용하여 형성된 전계의 변화를 관찰하였다. 대부분 스위치 전각에 인가되는 펄스는 펄스 인가시간, 플래토(plateau)시간, 펄스 회복시간으로 구성되어 이들 세 가지 시간 구간에 따라서 전위의 변화를 측정하여 형성되는 전계를 관찰하였다. 빠른 방전 스위치의 동작특성을 이해하기 위하여 스위치 전극인가 전압의 인가시간 변화와 이에 따른 전압 변화율 및 인가전압의 크기에 따른 플라즈마 쉬스의 거동을 관찰하고, 그 크기가 펄스 변화율과 크기에 따라 변화함을 찾았다. 펄스의 회복시간 동안에 돌아오는 플라즈마 쉬스의 거동은 펄스의 인가시간동안의 변화와 유사한 거동을 보였으며 이때에도 펄스 회복율이 중요한 인자임을 알 수 있었다. 만일 펄스 변화율이 커서, 전극 앞에서의 쉬스의 거동 속도가 플라즈마 이온의 음속보다 빠르게 변할 때는 이온 매트릭스 쉬스의 거동형태를 따르고, 변화율이 늦어서 쉬스의 거동 속도가 이온의 음속보다 느리게 변하는 경우에는 Child-Langmuir 쉬스의 형태가 시간에 따라 전개됨을 알 수 있었다. 펄스 특성을 정량적으로 관찰할 수 있도록 스위치 전극에 흐르는 전류의 크기를 계산하기 위해 필요한 모델을 개발하여 실험견과와의 비교를 통하여 펄스 시간동안 플라즈마의 거동이 스위치를 흐르는 전류에 미치는 영향을 연구하였다.

  • PDF

The implementation of Lab-on-a-chip type Glucose sensor which uses PVA and design (PVA를 이용한 Lab-on-a-chip type Glucose sensor설계 및 구현)

  • Lee, S.R.;Kim, G.Y.;Lee, Y.T.;Seo, H.D.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.927-931
    • /
    • 2004
  • 본 논문에서는 혈당측정기 제작에 있어 PDMS(Su-8)를 이용하였다. 이는 일종의 고분자로서 기계적 특성이 우수하고 제작이 간단하며, 가격이 저렴하고 다른 물질과의 접합이 용이하다. 혈액의 펌핑과 믹싱을 할 수 있도록 새로운 구조체를 설계하였으며 제안된 모델의 핵심 부분인 측정전극의 제작에 필요한 기초적인 실험을 수행하였다. 측정전극의 성능향상과 제작편의성, 저가격화를 위해 효소고정화방법으로 Electrospinning (전기방사)으로 제조된 PVA nanofiber web을 이용하였으며, 이는 중합도 Pn=1700, 비누화도 98%인 공업용으로 상용화된 값싼 제품이다. 따라서 이를 이용하면 측정용 전극의 효소고정화에 있어 저가격화를 이룰 수 있을 것으로 기대된다 고정화된 전극분석을 위해 SEM(주사전자현미경)과 NMR(핵자기공명분광계), FT-IR(적외선분광분석)장비를 사용하였다. 그리고 기존의 효소고정화법(전기중합법)과의 응답특성을 비교분석하였다.

  • PDF