• Title/Summary/Keyword: 전극거리

Search Result 196, Processing Time 0.031 seconds

Research on Comparison of Individual and Connecting Grounding Electrode for Potential Rise Distribution (개별 접지전극과 연접된 접지전극의 전위상승 분포 비교 연구)

  • Gil, Hyoung-Jun;Choi, Chung-Seog;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.57-62
    • /
    • 2008
  • This paper deals with a comparison of individual and connecting grounding electrode for potential rise. When a test current flowed through grounding electrode, potential rise was measured and analyzed for grounding method using a electrolytic tank in real time. In order to analyze the potential rise of grounding systems, a hemispherical water tank experimental apparatus was studied. Potential rise was measured and analyzed regarding the grounding method and distance by using this apparatus. The apparatus was composed of a hemispherical water tank, AC power supply, a movable potentiometer, and test grounding electrodes. The potential rise was measured by the horizontal moving probe of the potentiometer. The grounding electrodes were designed and fabricated with ground rods on a scale of one-eightieth. Potential rises of individual grounding electrode were higher than those of connecting grounding electrode. The distributions of surface potential are dependent on the distance from grounding electrode.

기판-타겟간 거리가 선형 대향 타겟 스퍼터 시스템으로 성장시킨 AGZO 전극 특성에 미치는 효과 연구

  • Sin, Hyeon-Su;Seo, Gi-Won;Lee, Ju-Hyeon;Kim, Han-Gi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.533-533
    • /
    • 2013
  • 본 연구에서는 선형 대향 타겟 스퍼터 시스템을 이용하여 hetero sputtering방법으로 증착한Al-Ga-Zn-O (AGZO) 박막의 기판-타겟간 거리(Target-to-Substrate distance)에 따른 전기적, 광학적, 구조적 특성을 분석하였다. 타겟과 기판 사이의 거리 변화(30~120 mm)에 따른 AGZO 박막의 특성 변화를 관찰하기 위하여 일정한 DC 파워 250 W, 공정압력 0.3 mTorr, Ar 20 sccm에서 서로 다른 AZO 타겟과 GZO 타겟을 이용하여 hetero-sputtering 공정을 진행하였다. 최적의 타겟과 기판 사이의 거리를 결정하기 위해 AGZO 박막의 투과도(T)와 면저항($R_{sh}$)을 기반으로 figure of merit ($T^{10}/R_{sh}$)값을 계산하였다. 기판-타겟간 거리는 AGZO 박막의 밀도에 영향을 주는 핵심 인자로 30 mm에서 120 mm로 증가수록 밀도가 낮은 AGZO 박막이 형성되었다. 최적의 타겟과 기판 사이의 거리(30 mm)에서 AGZO 박막은 132 Ohm/sq의 낮은 면저항과 87.2%의 높은 투과도를 나타내었다. 그러나 기판-타겟간 거리가 증가할수록 같은 두께에서 면저항은 급격히 증가함을 발견할 수 있었으며 이러한 특성 변화는 스퍼터되어 기판에 도달하는 입자의 에너지 차이로 설명이 가능하다. 따라서 본 연구에서는 기판-타겟간 거리에 따른 AGZO 박막의 특성 변화를 설명할 수 있는 메커니즘을 다양한 분석을 통해 제시하였다. 또한 적화된 AGZO 투명 전극을 이용해 제작한 GaN-LED의 Damage free sputtering 기술에 대해서 소개한다.

  • PDF

Modeling of Two-dimensional Self-consistent RF Plasmas on Discharge Chamber Structures (전극 구조에 관한 2차원 RF 플라즈마의 모델링)

  • So, Soon-Youl;Lim, Jang-Seob;Kim, Chel-Woon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.1-8
    • /
    • 2005
  • Plasma researches using parallel-plate electrodes are widely used in semiconductor application such as etching and thin film deposition. Therefore, a quantitative understanding and control of plasma behavior are becoming increasingly necessary because their important applications and simulation techniques have been actively carried out in order to solve such problems above. In this paper, we developed a two-dimensional(2D) self-consistent fluid model, because 2D models can deal with real reactor geometries. The fluid model is based on particle continuity equations for taking account of an electrode system in a cylindrical geometry. An pure Ar gas was used at 500[mTorr] and radio-frequency (13.56(MHz)). Four models were simulated under the different electrode geometries which have chamber widths of 5.25, 6.0, 8.0, and 10.0[cm] and we compared their results with each other. Plasma uniformity and a do self-bias voltage were also discussed.

A Study of Polarity Effect of Parallel Plate Type ionization Chamber with Different Volume (평행평판형 전리함의 두 전극간의 거리에 따른 극성효과 연구)

  • 윤형근;신교철
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.69-73
    • /
    • 2002
  • Exposure measurement data with parallel plate ionization chambers were known to depend on the polarity ($k_{pol}$) effect. In this work, the polarity effect were investigated for three parallel plate ionization chambers with different volume. The ionization chamber was fabricated using acrylic plate for the chamber medium and printed circuit board for electrical configuration. The various sizes of the sensitive volumes designed so far were 0.9, 1.9, and 3.1 co. High voltage generator was fabricated using the conventional 9 V batteries to apply the high voltage (300-500 V) to the electrode of the parallel plate ionization chamber. The gap between two electrodes ranged from 3, 6, and 10mm. As the result of our experiment, the polarity effect was within 0.5% in photon beam and 1% to 3.5% in the electron beams. Among electron beams, 16 MeV beam, which had highest energy, showed less polarity effect than electron beams with other energies.

  • PDF

Calculation of Deposit Thickness Distribution According to Distance between Contact Points of Rack (랙의 접점간 거리에 따른 도금 두께 분포 계산)

  • Lee, Min-Su;Park, Jae-Yeong;Im, Tae-Hong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.162-162
    • /
    • 2016
  • 비전도체를 피도금체로 하여 전기 도금을 하는 경우 우선 피도금체 상에 시드 층을 형성 시키고 이후 여러 번의 전기도금을 거치게 된다. 이때 접점의 위치와 전류 인가 방법은 도금 특성에 영향을 미치게 된다. 이를 고찰하기 위하여 접점간 거리에 따른 도금 두께 분포 계산을 하였다. 본 연구에서는 도금 분포 계산을 위해 Elsyca社의 PlatingMaster를 사용하였다. 방향별 도금 두께 분포의 변화를 극명하게 관찰하기 위하여 종횡비 10:1로 음극과 양극 모델링을 하였고 접점의 개수는 1 ~ 3개, 접점의 위치는 10 mm 간격으로 이동하는 것을 변수로 하였다. 피도금체의 시드 층은 니켈 층으로 두께 $0.4{\mu}m$로 설정하고 유산동 도금 용액을 이용하여 용액 데이터베이스 측정하고 반영하였다. 계산을 위한 전류 밀도는 $50mA/cm^2$, 도금시간은 10분으로 모든 모델에서 동일하게 적용하였다. 도금이 성장한 면의 두께를 폭과 길이 방향으로 비교 관찰한 결과 전극간의 거리는 시드 층이 얇을수록 두께 분포에 큰 영향을 미쳤다. 하지만 하지 도금 층의 두께가 충분히 두꺼운 경우 전극간의 거리는 큰 영향을 미치지 않는다.

  • PDF

Effects of the Current Probe on Ground Resistance Measurements Using Fall-of-Potential Method (전위강하법에 의한 접지저항측정에 미치는 전류보조전극의 영향)

  • 이복희;엄주홍
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.69-77
    • /
    • 2000
  • In this paper, the effects of the positions of the potential and current probes on the measurements of the ground resistance and potential gradients with the fall-of-potential method are described and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and ground resistance of the measuring probes. The ground resistance is calculated by applying the 61.8% and rule in the fall-of-potential method, and then the potential probe is located on the straight line between the grounding electrode to be measured and the current probe. However, sometimes the grounding electrode to be measured and the measuring probes in on-site test might not be arranged on the straight line with adequate distance because there are building, road block, construction and other establishments. Provided that the grounding electrode to be measured and the measuring probes ar out of position on the straight line or have inadequate distance, the measurement of the ground resistance classically falls into an error and the measured ground resistance should be corrected. Measurements were focused on the grounding electrode system made by the ground rods of 2.4m long. It was found that the suitable separation between the grounding electrode to be measured and the current probe is more than 5 times of the length of the grounding electrode to be measured.

  • PDF

Studies on Contact Characteristics in Metal/OEL this films (금속/유기발광박막 간의 접합특성 연구)

  • 이호철;강수창;신무환
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.96-98
    • /
    • 1999
  • 유기전계발광소자(OELD)의 성능 향상을 위한 많은 연구가 진행되고 있지만 아직까지 금속전극과 유기발 광층 사이의 접촉저항(Contact Resistance)에 관한 연구는 거의 보고되지 않고 있다. Ohmic 접합에서 접촉 저항은 효율적이고 신뢰성 있는 소자제작에 있어서 간과되어서는 안될 매우 중요한 부분이다. 본 연구에서는 금속전극과 유기발광충 사이의 접촉저항에 관해서 논의하고자 한다. 본 연구에서 제작된 샘플은 금속전극으로 Ag, 유기발광재료로서 Alq$_3$를 사용하였으며, Alq3의 두께를 100 $\AA$에서 500 $\AA$까지 각각 다르게 하여 서로 다른 두께의 유기발광층을 가지는 샘플을 제작하였다. 금속전극의 매트릭스 구조에 의해 형성된 적선의 크기는 3 mm x 2 mm이며, 제작된 샘플의 접촉비저항은 TLM(Transmission Line Measurement) 방법을 이용하여 구하였다. Planar한 TLM model로부터 새로운 vertical model을 유추하였으며, 이를 근거로 접촉저항 및 transfer length 등을 계산하였다. 상온에서 측정된 전체 저항값은 유기발광층의 두께가 증가함 에 따라 증가하는 경향을 나타냈으며, 이 때 계산된 접촉비저항은 1.49$\times$$10^1$ $\Omega$-$\textrm{cm}^2$ 이다. 접촉저항은 전극 사이의 거리의 증가에 따라 증가하지만, 측정시간의 thermal budget의 영향으로 상대적으로 전체저항이 감 소하였으나, 저항감소분의 포화에 따라서, 거리에 비례하여 다시 저항이 증가하였다.

  • PDF

Influences of the electrode surface states on the spark voltage in gas discharges (기체방전에서 불꽃파괴전압에 미치는 전극표면상태의 영향)

  • 백용현;이복희;전덕규;조성욱;서국철
    • Electrical & Electronic Materials
    • /
    • v.4 no.1
    • /
    • pp.65-72
    • /
    • 1991
  • 본 논문은 전극의 표면상태가 기체방전의 전리성장과 특성에 미치는 영향에 관한 것으로 질소-산소 혼합가스중의 순수전극과 오손전극의 상태에서 전압-전류 특성과 글로우방전 개시전압을 측정하였다. 순수전극의 경우, 압력과 전극간의 거리의 곱이 8(Torr-cm)이하이고 산소의 혼입량이 0.005(%)이하일 때의 전리성장은 암류로부터 안정타운젠트방전을 거쳐 글로우방전으로 이행되었으며 글로우방전 개시전압은 거의 일정하였다. 동일의 전극표면상태에서 조차 방전개시전압은 산소혼입비에 의존하며 방전횟수에 따른 이의 변화는 산소의 함량이 0.1(%)부근에서 크게 나타났다. 방전횟수와 산소혼입량의 증가에 따른 방전개시전압의 상승은 주로 전극표면에서의 산소흡착층의 형성과 부착작용에 의한 NO, $O_{2}$, NO$_{2}$, $O_{3}$와 간은 부이온의 생성에 기인된 것으로 여겨진다.

  • PDF

Characteristics on Electroosmosis Ground Improvement Using Nano-geosynthetics (나노섬유를 이용한 동전기 지반개량에 관한 특성)

  • Ahn, Kwangkuk;Jeong, Kusic;Lee, JunDae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.4
    • /
    • pp.59-63
    • /
    • 2009
  • In this study, Nano-geosynthetics with electroosmosis method was used and tried to verify the possibility of usage for soft ground improvement. Electroosmosis tests were performed with increasing the voltage level and changing distance between electrodes. The electrokinetic cell was assembled and a Nano-geosynthetics was inserted into the plastic drain board. And electroosmosis was applied to the disturbed kaolin clay. In order to study the effects of ground improvement, ground settlement, water content, collected pore water and shear strength were compared and analyzed with non-applied kaolin clay. Also, the electroosmosis tests were performed with changing the distance between electrodes and the voltage size. As a results of changing the distance and voltage between electrodes, the more voltage size was increased, the more the settlement of ground, shear strength and collected pore water were increased. As the distance between electrodes were increased, the settlement of ground, shear strength, water content and collected pore water were decreased. Finally, Nano-geosynthetics as a material of electrode have the sufficient potential to improve soft ground.

  • PDF

Earth Resistance Measurement Method by Clamp-one Type Current Comparison (클램프온식 전류비교 접지저항 측정방법)

  • Jeong, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.353-355
    • /
    • 2007
  • 피접지체의 접지는 전력설비의 절연파괴,낙뢰 등으로 전압이 침입할 경우 접지전극의 접지저항이 높으면 접지전극으로 유입되는 전류와 접지저항의 곱에 해당하는 접지전극의 전위가 상승하게 되므로 설비의 파손 인축의 피해 등이 발생 할 수 있다. 따라서 접지저항은 낮은 값으로 유지하는것이 필요하고 정기적으로 측정하여 관리하도록 규정하고 있다. 대표적인 접지저항측정방법으로는 3전극법(Fall of potential method)과 Hook-on 측정법이 있다. 그러나 3전극법은 측정하고자 하는 접지전극으로부터 일정한 거리에 전류를 흘려주고 이때 대지 전위를 측정 할 수 있는 2개의 보조전극 설치가 필수적이나 접지극과 접지선의 단자와는 설치 위치가 다르므로 접지전극의 설치점을 확인하기 곤란하고 건물내부, 지하철, 터널 등에는 보조전극의 설치가 거의 불가능하므로 처음 설치한 접지극의 접지저항측정관리에 어려움이 크다. 또한 Hook-on 측정법은 다중 접지 계통에 사용하는 방법으로 접지극이 수십 또는 수백개를 병렬로 연결한 경우 측정하고저 하는 접지그의 접지저항값에 비해 나머지 접지전극 전체의 합성저항이 무시할 수 있을 만큼 적은 경우에만 측정할 수 있으므로 건물이나 변전실 등 수개의 접지극이 설치된 경우는 사용할 수 없다. 본 연구는 보조전극을 설치하지 않고 측정하고자하는 접지전극 상호간의 전류분배 비율을 저항의 역수 비율로 하여 각각의 접지 전극의 접지저항값을 운전 중인 상태에서 간단하고 정확하게 측정할 수 있는 새로운 접지저항 측정 방법에 관한 연구이다.

  • PDF