• Title/Summary/Keyword: 적합도 분석

Search Result 13,663, Processing Time 0.049 seconds

An Efficient Application of XML Schema Matching Technique to Structural Calculation Document of Bridge (XML 스키마 매칭 기법의 교량 구조계산서 적용 방안)

  • Park, Sang Il;Kim, Bong-Geun;Lee, Sang-Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1D
    • /
    • pp.51-59
    • /
    • 2012
  • An efficient application method of XML schema matching technique to the document structure of structural calculation document (SCD) of bridge is proposed. With 30 case studies, a parametric study on weightings of name, sibling, child, and parent elements of XML scheme component that are used in the similarity measure of XML schema matching technique has been performed, and suitable weighting to analyze document structure of SCD is suggested. A simplified formula for quantification of similarity is also introduced to reduce computation time in huge scale document structure of SCDs. Numerical experiments show that the suggested method can increase the accuracy of XML schema matching by 10% with suitable weighting parameters, and can maintain almost the same accuracy without weighting parameters compared to previous studies. In addition, computation time can be reduced dramatically when the proposed simplified formula for the quantification of similarity is used. In the numerical experiments of testing 20 practical SCDs of bridges, the suggested method is superior to previous studies in the accuracy of analyzing document structure and 4 to 460 times faster than the previous results in computation time.

A Study on Changes in Pore Water Quality of Polluted Sediment due to Mixing Ratio of Granulated Coal Ash (석탄회 조립물 혼합비율에 따른 오염 퇴적물의 간극수 수질 변화에 관한 연구)

  • Lee, In-Cheol;Woo, Hee-Eun;Kim, Kyeongmin;Lee, Jun-Ho;Kim, Kyunghoi
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.30 no.5
    • /
    • pp.201-206
    • /
    • 2018
  • This study investigated the changes in pore water quality of polluted sediment by mixing ratio of granulated coal ash. The mesocosm experiments were carried out with 0%, 10%, 30% and 50%, respectively, of the material mixture ratio relative to the sediments. According to the results of the experiments, pH increased depending on the mixing ratio. Phosphate and ammonia concentrations were significantly decreased in the mixing ratio of 30% and 50% compared to the control (p < 0.05). The concentration of hydrogen sulfide was reduced by 72% at the mixing ratio of 10%, and it was not detected at the mixing ratio of 30% and 50%. This study was confirmed that granulated coal ash can change the pore water quality of polluted sediments in proportion to the amount of material. However, the effect of the mixing ratio between 30% and 50% was not significantly different, thus it is concluded that mixing of 30% of the volume of the sediment is economically feasible.

A case study on the bolt failure of the moving parts of a marine diesel engine (선박용 디젤기관의 운동부 볼트 손상사례에 대한 연구)

  • Kim, Jong-Ho;Lee, Jae-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.118-124
    • /
    • 2017
  • To investigate and analyze the cause of the failure of the connecting rod bolt and the crank pin bearing bolt of the diesel engine of this study, the following results were obtained through site surveying, the investigation of literature referring to similar failures, testing and inspection of the fracture surface, and the experience of the researchers. The fractured crank pin bearing bolt of the diesel engine is estimated to be damaged later than the connecting rod bolt. From the shape of fracture surface, it is evident that the failed connecting rod bolt is fractured by fatigue failure due to abnormally repeated loads (e.g. loosening of the connecting bolt, etc.), and is not failed by brittle fractures due to the impact load. The surface of the U-nut on the fractured connecting rod bolt has been worsening due to the improper use of lubricant (agent for prevention of thread fixing) and no usage of separating the each connecting rod on each cylinder. Moreover, there is the possibility that those poor surface conditions of the fractured connecting rod bolt have affected the failure of the connecting rod bolt of the main engine. And it could be assumed that the mechanical characteristic and manufacturing process of the failed connecting rod bolt and crank pin bearing bolt, which were made by a domestic company, conform to the design requirements for those bolts.

Feasibility of Tobacco(Nicotiana tabacum L.) for Phytoremediation of Soil Contaminated with Zn and Cu (Zn 및 Cu 오염토양에서 담배에 의한 복원 탐색)

  • Lee, Sang-Gak;Kang, Byeung-Hoa
    • Korean Journal of Environmental Agriculture
    • /
    • v.20 no.4
    • /
    • pp.211-217
    • /
    • 2001
  • This study was conducted to evaluate the effect of Zn and Cu on physiological responses of tobacco at the different leaf ages for the purpose of phytoremediation of heavy metal contaminated field. Plant height was significantly decreased at Zn and Cu concentrations of 1.0 mM or higher. Especially, root dry weight decreased more (50% reduced) than shoot dry weight. Zn and Cu accumulation in the shoot and root was dramatically increased after 2.0 mM treatment. The accumulation pattern was different by leaf aging in that Zn accumulated more in senescence leaf and Cu accumulated more in growing leaf. The amounts of heavy metal accumulations per plant were 146,000 mg/kg for Zn and 20,500 mg/kg for Cu at 2.0 mM treatment. The proper harvesting time would be suggested as vegetative growth stage for Zn and reproductive stage for Cu. The concentrations of other inorganic ions (Mg, Mn, Fe) were decreased when Zn and Cu concentrations were increased. Cu concentration and Zn concentration of both shoot and root were decreased in Zn treatment and Cu treatment, respectively.

  • PDF

Growth and Physiological Responses of Indeciduous Quercus L. in Container by Fertilizing Treatment (시비 처리에 따른 상록 참나무속 수목의 용기 내 생장 및 생리적 반응)

  • Kim, Jong Jin;Lee, Seung Hak;Song, Ki Seon;Jeon, Kwon Seok;Choi, Jin Young;Choi, Kyu Seong;Lee, Seok Noh;Sung, Hwan In
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.4
    • /
    • pp.372-380
    • /
    • 2014
  • BACKGROUND: This study was carried out in order to closely examine the influence of fertilization upon growth in container of seedling in indeciduous Quercus species (Q. mysinaefolia, Q. acuta and Q. glauca). METHODS AND RESULTS: Fertilizer level was made by adjusting water soluble compound fertilizer (N:P:K=19: 19:19, v/v) to 1000, 2000, $3000mg{\cdot}L^{-1}$ level along with non-fertilizing plot. Fertilization increased height, root collar diameter growth, and dry weight in these three species of trees. The more increase in fertilizer level led to the more rise even in growth of these species. H/D ratio and T/R ratio also showed tendency of getting bigger in the more rise in fertilizer level. Photosynthetic rate was shown to get higher in the higher fertilizer level according to fertilization in all the three species. In the analysis of root morphological traits, the total root length was surveyed to be longer in the more rise in fertilizer concentration. As even a case of root project area, surface area, and root volume is the similar tendency to characteristics in the total root length, a rise depending on fertilization was observed. CONCLUSION: In light of the results in this experiment, the fertilizer level is judged to be $2000mg{\cdot}L^{-1}$ level that is proper for production of 1-year-old container seedling in indeciduous Quercus species with excellent root development and high seedling quality index.

Microseismic Monitoring for KAERI Underground Research Tunnel (KURT 미소진동 모니터링)

  • Kim, Kyung-Su;Bae, Dae-Seok;Koh, Yong-Kwon;Kim, Jung-Yul
    • The Journal of Engineering Geology
    • /
    • v.19 no.2
    • /
    • pp.139-144
    • /
    • 2009
  • The microseismic monitoring system with wide range of frequency has been operating in real time and it is remotely monitored at indoor and on-site for one year. This system was constructed and established in order to secure the safe and effective operation of the KAERI Underground Research Tunnel(KURT). For one year monitoring work, total 14 events were recorded in the vicinity of the KURT, and the majority of events are regarded as ultramicroseismic earthquake and artificial impacts around the tunnel. The major event is the magnitude 3.4 earthquake which was centered around Gongju city, Chungnam Province. It means that there is no significant evidence of high frequency microseismic event, which is associated with fracture initiation and/or propagation in the rock mass and shotcrete. Three components sensor was applied in order to analyze and define the direction of vibration as well as an epicenter of microseismic origin, and also properly designed and installed in a small borehole. This monitoring system is able to predict the location and timing of fracturing of rock mass and rock fall around an undreground openings as well as analysis on safety of various kinds of engineering structures such as nuclear facilities and other structures.

A Study on the Safety Characterization Grounding Design of the Inner Photovoltaic System (태양광 발전단지 내부 그리드의 안전 특성화 접지 설계에 관한 연구)

  • Kim, Hong-Yong;Yoon, Suk-Ho
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.2
    • /
    • pp.130-140
    • /
    • 2018
  • Purpose: In this paper, we propose a design technique for the safety characterization grounding in the construction of the photovoltaic power generation complex which can be useful and useful as an alternative power energy source in our society. In other words, we will introduce the application of safety grounding for each application, which can improve and optimize the reliability of the internal grid from the cell module to the electric room in the photovoltaic power generation complex. Method: We analyze the earth resistivity of the soil in the solar power plant and use the computer program (CDEGS) to analyze the contact voltage and stratospheric voltage causing the electric shock, and propose the calculation and calculation method of the safety ground. In addition, we will discuss the importance of semi-permanent ground electrode selection in consideration of soil environment. Results: We could obtain the maximum and minimum value of ground resistivity for each of the three areas of the data measured by the Wenner 4 - electrode method. The measured data was substituted into the basic equation and calculated with a MATLAB computer program. That is, it can be determined that the thickness of the minimum resistance value is the most favorable soil environment for installing the ground electrode. Conclusion: Through this study, we propose a grounding system design method that can suppress the potential rise on the ground surface in the inner grid of solar power plant according to each case. However, the development of smart devices capable of accumulating big data and a monitoring system capable of real-time monitoring of seismic changes in earth resistances and grounding systems should be further studied.

Cloud P2P OLAP: Query Processing Method and Index structure for Peer-to-Peer OLAP on Cloud Computing (Cloud P2P OLAP: 클라우드 컴퓨팅 환경에서의 Peer-to-Peer OLAP 질의처리기법 및 인덱스 구조)

  • Joo, Kil-Hong;Kim, Hun-Dong;Lee, Won-Suk
    • Journal of Internet Computing and Services
    • /
    • v.12 no.4
    • /
    • pp.157-172
    • /
    • 2011
  • The latest active studies on distributed OLAP to adopt a distributed environment are mainly focused on DHT P2P OLAP and Grid OLAP. However, these approaches have its weak points, the P2P OLAP has limitations to multidimensional range queries in the cloud computing environment due to the nature of structured P2P. On the other hand, the Grid OLAP has no regard for adjacency and time series. It focused on its own sub set lookup algorithm. To overcome the above limits, this paper proposes an efficient central managed P2P approach for a cloud computing environment. When a multi-level hybrid P2P method is combined with an index load distribution scheme, the performance of a multi-dimensional range query is enhanced. The proposed scheme makes the OLAP query results of a user to be able to reused by other users' volatile cube search. For this purpose, this paper examines the combination of an aggregation cube hierarchy tree, a quad-tree, and an interval-tree as an efficient index structure. As a result, the proposed cloud P2P OLAP scheme can manage the adjacency and time series factor of an OLAP query. The performance of the proposed scheme is analyzed by a series of experiments to identify its various characteristics.

Study on CO2-Coal Gasification Reaction Using Natural Mineral Catalysts (천연 광물질을 이용한 CO2 석탄 촉매 가스화 반응 특성 연구)

  • Lee, Roosse;Sohn, Jung Min
    • Applied Chemistry for Engineering
    • /
    • v.27 no.1
    • /
    • pp.56-61
    • /
    • 2016
  • In this study, the effect of natural minerals on the reaction kinetics for lignite-$CO_2$ gasification was investigated. After physical mixing of lignite from Meng Tai area with 5 wt% of each natural mineral catalysts among Dolomite, Silica sand, Olivine and Kaolin, $CO_2$ gasification was performed using TGA at each 800, $850^{\circ}C$ and $900^{\circ}C$. The experimental data was analyzed with volumetric reaction model (VRM), shrinking core model (SCM) and modified volumetric reaction model (MVRM). MVRM was the most suitable among three models. As increasing the reaction temperature, the reaction rate constant became higher. With natural mineral catalysts, the reaction rate constant was higher and activation energy was lower than that of without catalysts. The lowest activation energy, 114.90 kJ/mol was obtained with silica sand. The highest reaction rate constant at $850^{\circ}C$ and $900^{\circ}C$ and lower reaction rate constant at $800^{\circ}C$ were obtained with Kaolin. Conclusively, the better catalytic performance could be observed with Kaolin than that of using other catalysts when the reaction temperature increased.

A Simulation of Temperature Control of Greenhouse with Hot-Water Heating System (온수난방시스템 온실의 온도제어 시뮬레이션)

  • 정태상;하종규;민영봉
    • Journal of Bio-Environment Control
    • /
    • v.8 no.3
    • /
    • pp.152-163
    • /
    • 1999
  • It is required to analyze the controlled response of air temperature in greenhouse according to control techniques for precise control. In this study, a mathematical model was established for air heating of greenhouse with hot-water heating system The parameters of the model were decided by regression analysis using reference data measured at the greenhouse being heated In the simulation for the digital control of air temperature in the greenhouse, the mathematical model to evaluate the control performances was used. Tested control methods were ON-OFF contpol, p control, rl control and PID control. The mathematical model represented by inside air temperature ( T$_{i}$), hot-water temperature (T$_{w}$) in heating pipe and outside air temperature (T$_{o}$) was expressed as a following discrete time equation ; T$_{i}$($textsc{k}$+1)= 0.851.T$_{i}$($textsc{k}$)+0.055.T$_{w}$($textsc{k}$)+0.094.T$_{o}$($textsc{k}$) Control simulations for various control methods showed the settling time, the overshoot and the steady state nor as follows; infinite time, 3.5$0^{\circ}C$, 3.5$0^{\circ}C$ for ON-OFF control : 30min 2.37$^{\circ}C$, 0.51$^{\circ}C$ for P control; 21min, 0.0$0^{\circ}C$, 0.23$^{\circ}C$ for PI control; 18min 0.0$0^{\circ}C$, 0.23$^{\circ}C$ for PID control, respectively. PI and PID controls appeared to be optimal control methods. There was no effect of differential gain on the heating process but much effect of integral gain on it.on it.

  • PDF