• Title/Summary/Keyword: 적외선 해석

Search Result 193, Processing Time 0.031 seconds

Analysis of the Characteristics of Flue Gas in Infrared Mobile Heaters for Gas Room Heating (가스난방용 적외선 히터의 연소배기가스 특성해석)

  • Kim Young-Gyu;Kwon Jeong-Rock;Kim Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.66-73
    • /
    • 1998
  • This paper deals with the combustion characteristics of flue gas in infared mobile heaters. The experimental work has been performed to obtain the concentration levels and combustion characteristics of flue gas with varying chamber size and room temperature. The experimental results showed that oxygen depletion sensor device was operated at the oxygen concentration level of $18.3\%$ for all the chamber size. The combustion characteristics of oxygen and carbon dioxide show a linearity After 10 minutes the combustion property of carbon monoxide occurs at random without a level of oxygen and carbon dioxide in closed space of the heater. In these results, it is very important to prevent incomplete combustion through a sufficient ventilation, and accident prevention with a reduction of the oxygen and diffusion of toxic carbon monoxide.

  • PDF

Stress Analysis and Fatigue limit Evaluation of Plate with Notch by Lock-In Thermography (Lock-In Thermography를 이용한 노치시험편의 응력해석 및 피로한계치 평가)

  • Kim, Won-Tae;Kang, Ki-Soo;Choi, Man-Yong;Park, Jeong-Hak;Huh, Yong-Hak
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.315-320
    • /
    • 2006
  • This paper describes stress analysis and fatigue limit evaluation of plate with V-notch and hole-notch by lock-in infrared thermography. Temperature variation of a specimen under cyclic loading is negatively proportional to the sum of principle stress change and the surface temperature measured by infrared camera is calculated to the stress of notch specimens, based on thermoelastic equation. And also, fatigue limitation can be evaluated by the change of intrinsic energy dissipation. Fatigue limitation of two notch specimens is evaluated as 164 MPa and 185 MPa, respectively and the stress measured by Lock-in infrared Thermography show good agreement within 10% error.

A Study on the Sampling of Ocean Meteorological Data to Analyze Signature of Naval Ships (함정 신호해석 연구에 필요한 해양기상환경 자료의 표본추출에 관한 연구)

  • Cho, Yong-Jin
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.2
    • /
    • pp.19-28
    • /
    • 2018
  • In this paper, we studied on the sampling of ocean meteorological data to analyze signature of naval ships. The newest ocean meteorological data, that was quality controled by the Korea Meteorological Administration(KMA), was collected. Outliers were removed from the data by setting the usable range of data. After that, the data size was reduced through the random sampling method, taking geopolitical significance and effective area of buoy, for probabilistic analysis. Moreover, the sample sizes were set at 100, 200, and 400 by considering the population size and a 95% confidence level. The final sample was obtained using the two-dimensional stratified sampling method based on highly correlated water temperature and air temperature. The sum of the squared errors and the confidence interval was calculated to compare the result of sampling. As a result, this study proposed reasonable sample size for infra­red signature analysis of naval ships.

Multiscale Analysis on Vibration of the Photo Responsive Polymer (광변형 고분자의 동적 진동에 관한 멀티스케일 해석)

  • Yun, Jung-Hoon;Li, Chenzhe;Chung, Hayoung;Choi, Joonmyung;Cho, Maenghyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.6
    • /
    • pp.571-575
    • /
    • 2016
  • Photo responsive polymer(PRP) is well known for its photo deformation under UV light, and goes back to its original shape in visible light due to the photoisomerization of the azobenzene inside the PRP. In this paper, dynamic study of the vibration in PRP is discussed. In order to predict photo-deformation of the PRP a multiscale modeling is introduced which covers quantum level photo excitation, microscopic morphology, and macroscopic deformation of the PRP. A simple 1D beam model is introduced to model dynamic bending behavior of the PRP. Through fast Fourious transformation analysis, we identify that vibration frequency of the PRP can be controlled by light polarization angle.

On-orbit Thermal Analysis for Verification of Thermal Design of Korea Pathfinder Lunar Orbiter (시험용 달 궤도선의 열설계 검증을 위한 궤도 열해석)

  • Jang, Byung-Kwan;Lee, Jang-Joon;Hyun, Bum-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.12
    • /
    • pp.1028-1036
    • /
    • 2018
  • KARI plans to launch Korea Pathfinder Lunar Orbiter (KPLO) to the Moon by December 2020 for the first step of the Korea Lunar Exploration Project. This orbiter will be launched to obtain lunar exploration technologies and science data in advance before launching a main orbiter and a lunar probe. This paper describes the verification of thermal design for the orbiter. It is exposed to more extreme thermal environment than that of low Earth orbit satellite due to the heavy infrared emission of the Moon. Accordingly, a thermal design considering this environment is needed to maintain the temperature of payloads and components equipped in the orbiter within operating temperature range in all orbits. We performed the thermal analysis for Earth-Moon transfer orbit, lunar mission orbit and lunar eclipse required for thermal design verification of the lunar orbiter. As a result, this thermal design met the design requirements.

Diagnosis of power supply by analysis of chaotic nonlinear dynamics (카오스 비선형 동력학 해석에 의한 수·변전설비의 진단)

  • Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.1
    • /
    • pp.113-119
    • /
    • 2013
  • In this paper, n order to degrade of diagnosis of power supply by using Poincare map and fractal dimension with temperature measured by infrared camera. we review the characteristic of temperature variation according to pattern variation of power supply in chemical industry complex. As a simulation results we can be realized the characteristic behaviors of nonlinear dynamics in the poincare mal and fractal dimension. In the future verification method requires through additional research.

A Two-dimensional Numerical Simulation of Self-signal Processing Infrared Detectors (자기신호처리 적외선 감지소자의 2차원 수치해석)

  • 조남홍;곽계달
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.11
    • /
    • pp.52-62
    • /
    • 1995
  • We developed a two-dimensional numerical simulator which can analyze the electrical as well as optical characteristics and evaluate the detection performances of self-signal processing infrared detectors. It solves the poisson equation and the electron, hole current continuity equations including the optical generation and recombination models. To speed up convergency rate. the Newton algorithm is used. Automatic triangular grid generator make it easy to simulate the devices with the various read-out geometries. This simulator can show the variation of spatial resolution which is caused by the transit velocity and transit time dispersion in bifurcate and horn geometries respectively. Also, we calculated the responsivity, noise, and detectivity in respect of the applied electric field and background field-of-view. The results obtained from simulation correspond to those of experiments, and it is verified that horn read-out geometry has the superior spatial resolution and detection performance to bifurcate geometry.

  • PDF

Synthesis and Characterization of Substituted Quinoline Complexes of Molybdenum (I). Substituted Quinolinium Salts of Pentachlorooxomolybdate (V) (몰리브덴(V)의 퀴놀린계 착물합성과 그 성질 (제2보). 오클로로옥소몰리브덴(V) 산의 치환퀴놀린윰염)

  • Kwang Lee;Sang-Oh Oh
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.5
    • /
    • pp.482-489
    • /
    • 1985
  • The substituted quinolinium salts of pentachlorooxomolybdate (V) have been synthesized and characterized by means of the investigation of elemental analysis, infrared spectra, electron spectra, electric conductivity. The results of elemental analysis were well coincided with the theoretical value and all prepared salts were mononuclear complexes. The complexes were binary univalent electrolytes and analyzed d-d transition and charge transfer transition.

  • PDF

Infrared Spectroscopic Study on the Effect of an External Electric Field on the Crystallization Behavior of PVDF (적외선분광분석을 통한 외부 전장이 PVDF 결정화 거동에 미치는 영향에 관한 연구)

  • 김갑진;조항원;이종순
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2002.04a
    • /
    • pp.97-100
    • /
    • 2002
  • PVDF를 전장하에서 용융결정화 하는 경우에 전장의 세기가 증가할수록 전기적으로 불활성인 $\alpha$-결정의 핵생성속도는 지연되는 반면에 전기적으로 활성을 갖는 ν-결정의 핵생성은 빨라지는 것으로 Stein 연구그룹이 일찍이 보고한 바 있다. [1,2] 그러나 실제로 PVDF를 용응 결정화하는 경우에는 결정화온도가 그다지 낮지 않는 경우에는 $\alpha$-결정과 ν-결정이 혼재되어 나타나기 때문에 외부 전장하리서의 용융결정화시에 외부전장의 세기가 $\alpha$-결정과 ν-결정의 핵생성속도 및 성장속도에 미치는 영향을 분리하여 해석한 논문은 거의 없다. (중략)

  • PDF

The Analysis of Temperature Distribution Electric incoming Apparatus Using a Infrared Thermal Imaging System (적외선 열화상 카메라를 이용한 수전설비 온도분포해석)

  • Jeong, Seung-Cheon;Lim, Yeung-Bae;Kim, Jong-Seo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1113-1116
    • /
    • 2004
  • This paper presents the method for analyzing surface temperature of Electric incoming Apparatus. For the experiment, the surface temperature of electric power apparatus was measured and analyzed by using a infrared thermal imaging system. Surface Discharges(SD) have very complex characteristics of discharge patterns, therefore it requires the development of precise analysis methods. recently, studies on infrared thermal imaging system are carried out to analyze temperature distribution of power equipments through condition diagnosis and to diagnose the degradation of power equipments. The changes in suface temperature was measured by using the infrared thermal imaging system under hot line condition. The system was set up based on the diagnostic method of the electric incoming apparatus.

  • PDF