• Title/Summary/Keyword: 적외선 열화상 이미지

Search Result 25, Processing Time 0.018 seconds

Assessment of Applicability of CNN Algorithm for Interpretation of Thermal Images Acquired in Superficial Defect Inspection Zones (포장층 이상구간에서 획득한 열화상 이미지 해석을 위한 CNN 알고리즘의 적용성 평가)

  • Jang, Byeong-Su;Kim, YoungSeok;Kim, Sewon ;Choi, Hyun-Jun;Yoon, Hyung-Koo
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.10
    • /
    • pp.41-48
    • /
    • 2023
  • The presence of abnormalities in the subgrade of roads poses safety risks to users and results in significant maintenance costs. In this study, we aimed to experimentally evaluate the temperature distributions in abnormal areas of subgrade materials using infrared cameras and analyze the data with machine learning techniques. The experimental site was configured as a cubic shape measuring 50 cm in width, length, and depth, with abnormal areas designated for water and air. Concrete blocks covered the upper part of the site to simulate the pavement layer. Temperature distribution was monitored over 23 h, from 4 PM to 3 PM the following day, resulting in image data and numerical temperature values extracted from the middle of the abnormal area. The temperature difference between the maximum and minimum values measured 34.8℃ for water, 34.2℃ for air, and 28.6℃ for the original subgrade. To classify conditions in the measured images, we employed the image analysis method of a convolutional neural network (CNN), utilizing ResNet-101 and SqueezeNet networks. The classification accuracies of ResNet-101 for water, air, and the original subgrade were 70%, 50%, and 80%, respectively. SqueezeNet achieved classification accuracies of 60% for water, 30% for air, and 70% for the original subgrade. This study highlights the effectiveness of CNN algorithms in analyzing subgrade properties and predicting subsurface conditions.

Nondestructive Evaluation of Defect Size by Using a Contrast Parameter of Infrared Image (적외선 열화상 이미지 컨트라스트 파라미터를 이용한 결함 크기의 비파괴 평가)

  • Choi, Jungyoung;Choi, Sooyoung;Kim, Jaeyeon;Yoo, Kitae;Park, Jaiwon;Hyun, Changyong;Byeon, Jaiwon
    • Journal of Applied Reliability
    • /
    • v.18 no.1
    • /
    • pp.87-94
    • /
    • 2018
  • Purpose: In this study, the defect quantification of thin metal plate was evaluated by using lock-in infrared thermography. Methods: A STS304 standard specimens, which had the artificial-defects of different size, were used. The focal distance between the infrared camera and the specimen was set to 500mm, and the distance between the lump and the specimen was set to 200mm. One halogen lamp with a maximum capacity of 1kW was used, and phase-lock infrared thermal images with a frequency of 1Hz were captured and analyzed. Result: Objectively quantified data values were obtained by analyzing the contrast ratio and signal-to-noise ratio. Conclusion: The possibility of defect diagnosis for thin metal plate was confirmed by using the lock-in infrared thermography technique.

Development of IR Thermal Camera Detector based on Smartphone Interlocking for Hidden Camera Crime Prevention (몰래카메라 범죄방지를 위한 스마트폰 연동 기반의 IR 열카메라 탐지기 개발)

  • Kang, Young-Gil;Cho, Pil-Gu;Kim, Young-Gon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.1-8
    • /
    • 2021
  • The performance of hidden camera cameras is improving day by day due to miniaturization and advanced technology integration according to the speed of technological development of smartphones. As this external networking computing environment is advanced and diversified, exposure to hidden cameras in addition to general safety cameras is also increasing. On the other hand, the technology for detecting and preventing hidden cameras is not keeping up with the development and speed of these hidden cameras. Therefore, in this study, the heat of the hidden camera was detected using infrared thermal detection technology based on general image and thermal image synthesis technology, and the reflectance of each wavelength according to the difference in ambient temperature was analyzed to reduce the false positive rate.

Nondestructive Deterioration Diagnosis and Environmental Investigation of the Stupa of the Buddhist Monk Soyo in Baegyangsa Temple, Jangseong (장성 백양사 소요대사탑의 비파괴 훼손도 진단과 입지환경 검토)

  • Kim, Yuri;Lee, Myeong Seong;Chun, Yu Gun;Lee, Mi Hye;Jwa, Yong-Joo
    • Korean Journal of Heritage: History & Science
    • /
    • v.49 no.4
    • /
    • pp.52-63
    • /
    • 2016
  • The Stupa of Buddhist Monk Soyo in Baegyangsa temple, Jangseong, was erected to pay a tribute to the achievement of the Buddhist monk Soyo, who worked for Baegyangsa temple as a chief monk, and is a bellshaped stupa with the detailed pattern of a Korean traditional buddhist bell. It is composed of pinkish-grey sandstone and the body of the stupa was damaged by longitudinal cracks on the front and back areas and the exfoliation caused break-out in the most part of the sculpture on the left and right areas. According to the ultrasonic test and infrared thermography analysis for physical deterioration diagnosis, most weathering aspects appeared on the body of the stupa and some exfoliated part that could not be seen with the naked eye was detected 6.1% and 5.9% on the left and right side respectively. Hyperspectral imaging analysis was also carried out to assess biological deterioration. According to the result, the surface of the stupa was covered 71.8 ~ 79.9% with vegetation like algae, lichen and moss. NDVI(Normalized Difference Vegetation Index) was higher relatively on the bottom part near the ground, right and back areas of the stupa. Therefore conservation treatment for the exfoliated part and bio-deterioration is necessary and the environment condition needs to be fixed to prevent extra damages on the stupa.

Performance Analysis of the Powerline Communication for Condition Monitoring System of an MW Class Offshore Wind Turbine's Nacelle (MW급 해상풍력발전기 나셀의 상태 감시를 위한 전력선 통신 성능 분석)

  • Sohn, Kyung-Rak;Kim, Kyoung-Hwa;Jeong, Seong-Uk;Nam, Seung-Yun;Kim, Hyun-Sik
    • Journal of Navigation and Port Research
    • /
    • v.40 no.3
    • /
    • pp.159-164
    • /
    • 2016
  • The goal of this study is to implement a communication system that can monitor the status of the nacelle using the power cable itself, without the dedicated communication lines such as an UTP cable and optical fiber for the offshore wind turbine. An inductive coupling powerline communication system for a MW class offshore wind turbine was proposed and its communication performance was demonstrated. The inductive couplers was designed for operation at up to 500 A using a ferrite composite materials. Field test was carried out on the wind farms of Jeju island. Using the iperf communication test program, we have obtained more than 15 Mbps data transmission rate through the 100 m power cable that was installed between the nacelle and the bottom of the power converter. In the data transmission stability test for a week, there was no failure ever. The minimum transmission rate was 15 Mbps and the average data rate was about 20 Mbps. Next, we have installed an infrared camera inside the nacelle in order to measure the temperature distribution and variation of the nacelle. The real-time thermal image taken by the camera was successfully sent to the monitoring system without error.