• Title/Summary/Keyword: 적외선 검출

Search Result 344, Processing Time 0.024 seconds

Preparation of Surface Functionalized Gold Nanoparticles and their Lateral Flow Immunoassay Applications (표면 개질된 금나노입자의 제조 및 이의 측방유동면역 센서 응용)

  • Kim, Dong Seok;Choi, Bong Gill
    • Applied Chemistry for Engineering
    • /
    • v.29 no.1
    • /
    • pp.97-102
    • /
    • 2018
  • In this work, the surface of gold nanoparticles (AuNPs) was modified with small molecules including mercaptoundecanoic acid (MUA) and L-lysine for the development of highly sensitive lateral flow (LF) sensors. Uniformly sized AuNps were synthesized by a modified Turkevich-Frens method, showing an average size of $16.7{\pm}2.1nm$. Functionalized AuNPs were then characterized by transmission electron microscopy, UV-vis spectroscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy. The stable conjugation of AuNPs and antibodies was obtained at pH 7.07 and the antibody concentration of $10{\mu}g/mL$. The functionalized AuNP-based LF sensor exhibited lower detection limit of 10 ng/mL for hepatitis B surface antigens than that of using the bare AuNP-based LF sensor (100 ng/mL).

Design and fabrication of a zoom optics having 20 magnification range for mid-IR(3.7-4.8$\mu$m) FLIR system (3.7-4.8$\mu$m 파장대역 FLIR 시스템을 위한 20:1 줌 렌즈 광학계 설계 및 제작)

  • 김현숙;김창우;홍석민
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.6
    • /
    • pp.462-467
    • /
    • 1999
  • This paper describes the design and fabrication of mid-IR $(3.7-4.8{\mu}m)$ zoom optics which is used for FUR (Forward Looking Infra-Red) system with 320 $\times$ 240 focal plane arrays. The zoom optics has 20 magnification range and maximun 40$^{\circ}$$\times$30$^{\circ}$ of super wide field of view. The locus of zoom is almost linear, which gives easy access of mechanical and electro-mechanical design. The on-axis MTF of zoom optics has been measured and it shows diffraction limited optical performance. For example, it gives 0.692 at 24 cycles/mm at highest magnification, and 7.6 cycles/mradof resolving power is achieved with the operation of attached micro-scanning system.system.

  • PDF

Study on the Brightness Temperature Measurement in the Human Body Using Millimeter-wave Radiometer (밀리미터파 라디오미터를 이용한 인체의 내부 밝기온도 측정에 관한 연구)

  • Jung, Min Kyoo;Kim, Tae Hun;Nah, Seung Wook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.163-167
    • /
    • 2016
  • We have developed a millimeter-wave radiometer system for applications in the fields of medical imaging. In this paper, we introduced the brightness temperature measurement in the human body using Millimeter-wave Radiometer. Calibration of sensitivity of the radiometer system is essential to measure equivalent temperature (brightness temperature) of objects. We have developed, as a calibration source, a new type of black body for the millimeter wave region with temperature control capability. The system noise figure and temperature sensitivity of the system measured using the blackbody are 3.3 dB and 0.1 K, respectively. The brightness temperature of human body through clothes was measured to be around $38^{\circ}$[C].

A Calibration Method for Multimodal dual Camera Environment (멀티모달 다중 카메라의 영상 보정방법)

  • Lim, Su-Chang;Kim, Do-Yeon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.9
    • /
    • pp.2138-2144
    • /
    • 2015
  • Multimodal dual camera system has a stereo-like configuration equipped with an infrared thermal and optical camera. This paper presents stereo calibration methods on multimodal dual camera system using a target board that can be recognized by both thermal and optical camera. While a typical stereo calibration method usually performed with extracted intrinsic and extrinsic camera parameter, consecutive image processing steps were applied in this paper as follows. Firstly, the corner points were detected from the two images, and then the pixel error rate, the size difference, the rotation degree between the two images were calculated by using the pixel coordinates of detected corner points. Secondly, calibration was performed with the calculated values via affine transform. Lastly, result image was reconstructed with mapping regions on calibrated image.

An ASIC Design for Photon Pulse Counting Particle Detection (광계수방식 물리입자 검출용 ASIC 설계)

  • Jung, Jun-Mo;Soh, Myung-Jin;Kim, Hyo-Sook;Han, AReum;Soh, Seul-Yi
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.947-953
    • /
    • 2019
  • The purpose of this paper is to explore an ASIC design for estimating sizes and concentrations of airborne micro-particles by the means of integrating, amplifying and digitizing electric charge signals generated by photo-sensors as it receives scattered photons by the presence of micro-particles, consisting of a pre-amplifier that detects and amplifies voltage or current signal from photo-sensor that generates charges (hole-electron pairs) when exposed to visible rays, infrared rays, ultraviolet rays, etc. according to the intensity of rays; a shaper for shaping the amplified signal to a semi-gaussian waveform; two discriminators and binary counters for outputting digital signals by comparing the magnitude of the shaped signal with an arbitrary reference voltages. The ASIC with the proposed architecture and functional blocks in this study was designed with a 0.18um standard CMOS technology from Global Foundries and the operation and performances of the ASIC has been verified by the silicons fabricated by using the process.

A Hybrid Navigation System for Intelligent Wheelchair (지능형 휠체어를 위한 하이브리드 내비게이션 시스템)

  • Ko, Eun-Jeong;Ju, Jin-Sun;Kim, Eun-Yi
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.552-557
    • /
    • 2009
  • In this paper, we propose hybrid navigation system, for obstacle detection and avoidance in Intelligent wheelchairs (IWs). To robustly detect obstacles and avoid them on various environments, hybrid navigation system combines both range-sensor and camera information. For this, 10 range-sensors (2 ultrasonic and 8 infra-red sensors) and CCD camera are used. Through processing the informations obtained from those sensors, our system can detect obstacles with various sizes and shapes, and then avoid them. To assess the effectiveness of the proposed hybrid navigation system, it was tested on complex environments including various obstacles, then the results showed the potential of our system as mobility aids for disabled people.

  • PDF

A Study on the Design of a ROIC for Uncooled Infrared Ray Detector Using Differential Delta Sampling Technique (차동 델타 샘플링 기법을 이용한 비냉각형 적외선 검출회로의 설계에 관한 연구)

  • Jung, Eun-Sik;Kwan, Oh-Sung;Lee, Po;Jeong, Se-Jin;Sung, Man-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.5
    • /
    • pp.387-391
    • /
    • 2011
  • A uncooled infrared ray sensor used in an infrared thermal imaging detector has many advantages. But because the uncooled infrared ray sensor is made by MEMS (micro-electro-mechanical system) process variation of offset is large. In this paper, to solve process variation of offset a ROIC for uncooled infrared ray sensor that has process variation of offset compensation technique using differential delta sampling and reference signal compensation circuit was proposed. As a result of simulation that uses the proposed ROIC, it was possible to acquire compensated output characteristics without process variation of offsets.

Enhancement of the Nighttime Image Exposure with IR LED Camera for surveillance camera (감시 시스템에서의 야간 영상 보정 알고리즘을 이용한 IR LED Camera의 적정 노출 영상 획득)

  • Woo, Seung-Won;Sohn, Jong-In;Kim, Seung-Ryong;Kim, Jun-Hyung;Kim, Young-Jung;Sohn, Kwang-Hoon
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2013.06a
    • /
    • pp.286-288
    • /
    • 2013
  • 감시 카메라에서 야간 시간대의 영상 품질은 매우 중요한 요소 중 하나이다. 본 논문에서는 IR LED Camera 에서 적외선 LED 를 사용한 회로적 제어를 통한 노출 제어에 문제점을 분석하고, 이를 해결하기 위한 적응적 배경 모델링과 IR 카메라의 특화된 객체 검출 방법을 제안한다. 노출 제어 방식의 배경을 제외한 적응적 배경과 객체의 합성으로 향상된 야간 영상획득 방식을 제안한다. 영상 개선 실험 결과는 기존의 회로적 노출 제어 방식의 영상보다 제안하는 방식이 프로세스의 단순화를 통한 비용 절감 효과와 야간 영상 품질 향상의 우수성을 보여준다.

  • PDF

A Study on the Improvement of Image Quality for a Thermal Imaging System with focal Plane Array Typed Sensor (초점면 배열 방식 열상 카메라 시스템의 화질 개선 연구)

  • 박세화
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.2
    • /
    • pp.27-31
    • /
    • 2000
  • Thermal imaging system is implemented for the measurement and the analysis of the thermal distribution of the target objects. The main Part of the system is thermal camera in which a focal plane array typed sensor is introduced The sensor detects mid-range infrared spectrum or target objects and then it output generic video signal which should be processed to form a thermal image frame. A digital signal processor(DSP) in the system inputs analog to digital converted data. performs algorithms to improve the thermal images and then outputs the corrected frame data to frame buffers for NTSC encoding and for digital outputs.. To enhance the quality of the thermal images, two point correction method is applied. Figures indicate that the corrected thermal images are much improved.

  • PDF

Structural and Electrical Properties of $V_{1.85}W_{0.15}O_5$ Thin Films for the Uncooled Infrared Detector (비냉각 적외선 검출기용 $V_{1.85}W_{0.15}O_5$ 박막의 구조적, 전기적 특성)

  • Nam, Sung-Pill;Ryu, Ki-Won;Lee, Sung-Gap;Bea, Seon-Gi;Lee, Young-Hie
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.237-238
    • /
    • 2008
  • The films of Vanadium tungsten oxide, $V_{1.85}W_{0.15}O_5$, were grown on Pt/Ti/$SiO_2$/Si substrate by RF sputtering method. The $V_{1.85}W_{0.15}O_5$ thin films deposited on Pt/Ti/$SiO_2$/Si substrates by RF sputtering method exhibited fairly good TCR and dielectric properties. It was found that film crystallinity, dielectric properties, and TCR properties were strongly dependent upon the annealing temperature. The dielectric constants of the $V_{1.85}W_{0.15}O_5$ thin films annealed at $300^{\circ}C$ were 55, with a dielectric loss of 1.435, respectively. Also, the TCR values of the $V_{1.85}W_{0.15}O_5$ thin films annealed at $300^{\circ}C$ were about -3.6%/K.

  • PDF