• Title/Summary/Keyword: 적외분광분석

Search Result 307, Processing Time 0.029 seconds

The analysis of the Effect the Minute Quantities of Infrared Rays that Were not Filtered by IR Cut-Off Filter has on Digital Images (IR Cut-Off Filter가 차단하지 못한 미량의 적외선이 디지털화상에 미치는 영향 분석)

  • Lee, Yong-Hwan;Park, Se-Won;Hong, Jung-Eui
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.205-215
    • /
    • 2011
  • Films are sensitive to ultraviolet rays and in contrast, digital camera sensors are extremely sensitive to infrared rays due to the differences in spectral characteristics. As a result, all digital cameras that use CCD or CMOS are equipped with IR Cut-Off Filter on the overall sensor. Complete block out of infrared rays is ideal, but the actual experiment results showed that infrared rays were not being blocked out completely. Infrared permeability was also different for each camera. Therefore, this study aims to analyze the effect of the minute quantities of infrared rays, which get transmitted due to mechanical properties of IR Cut-Off Filters that are installed on digital cameras, on digital picture images. The results obtained by carrying out a comparative analysis of a UV Filter (infrared transmitting state) and a UV-IR Filter (infrared blocked out state) are as follows. It was confirmed that the minute quantities of infrared rays do affect dynamic range and resolution to some extent, despite the little or no difference in noise and color reproduction.

Fabrication and Magnetic Properties of BaFe12-2xCoxTixO19 Powders (BaFe12-2xCoxTixO19 분말의 제조 및 자기특성 연구)

  • An, Sung-Yong;Shim, In-Bo;Kim, Chul-Sung;Lee, Seung-Wha
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.1
    • /
    • pp.21-28
    • /
    • 2003
  • M-type hexagonal BaF $e_{12-2x}$ $Co_{x}$ $Ti_{x}$ $O_{19}$ (0$\leq$x$\leq$1.0) ferrite powders prepared by a sol-gel method. The crystallographic and magnetic properties were characterized with a x-ray diffraction (XRD), thermogravimetry (TG), differential thermal analysis (DIA), Fourier transform infrared spectroscopy (FT-IR), vibrating sample magnetometer (VSM), and Mossbauer spectroscopy. The result of XRD measurements show that the a and c lattice parameters increase with increasing x from $\alpha$=5.882 and c=23.215 $\AA$ for $\chi$=0.0, to $\alpha$=5.895 and c=23.295 $\AA$ for $\chi$=1.0. From the Mossbauer results, the $Co^{2+}$- $Ti^{4+}$ site occupancies have been affected the changes in the magnetization and in the coercivity. The Curie temperature linearly decreases with increasing $Co^{2+}$- $Ti^{4+}$ concentration x.

Discrimination of Pasture Spices for Italian Ryegrass, Perennial Ryegrass and Tall Fescue Using Near Infrared Spectroscopy (근적외선분광법을 이용한 이탈리안 라이그라스, 페레니얼 라이그라스,톨 페스큐 종자의 초종 판별)

  • Park, Hyung Soo;Choi, Ki Choon;Kim, Ji Hye;So, Min Jeong;Lee, Ki Won;Lee, Sang Hoon
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.35 no.2
    • /
    • pp.125-130
    • /
    • 2015
  • The objective of this study was to investigate the feasibility of using near infrared spectroscopy (NIRS) to discriminate between grass spices. A combination of NIRS and chemometrics was used to discriminate between Italian ryegrass, perennial ryegrass, and tall fescue seeds. A total of 240 samples were used to develop the best discriminant equation, whereby three spectra range (visible, NIR, and full range) were applied within a 680 nm to 2500 nm wavelength. The calibration equation for the discriminant analysis was developed using partial least square (PLS) regression and discrimination equation (DE) analysis. A PLS discriminant analysis model for the three spectra range that was developed with the mathematic pretreatment "1,8,8,1" successfully discriminated between Italian ryegrass, perennial ryegrass, and tall fescue. An external validation indicated that all of the samples were discriminated correctly. The discriminant accuracy was shown as 68%, 78%, and 73% for Italian ryegrass, perennial ryegrass, and tall fescue, respectively, with the NIR full-range spectra. The results demonstrate the usefulness of the NIRS-chemometrics combination as a rapid method for the discrimination of grass species by seed.

Variey Discrimination of Sorghum-Sudangrass Hybrids Seed Using near Infrared Spectroscopy (근적외선분광법을 이용한 수수×수단그라스 교잡종 종자의 품종 판별)

  • Lee, Ki-Won;Song, Yowook;Kim, Ji Hye;Rahman, Md Atikur;Oh, Mirae;Park, Hyung Soo
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.40 no.4
    • /
    • pp.259-264
    • /
    • 2020
  • The aim of this study was to investigate the feasibility of discrimination 12 different cultivar of sorghum × sudangrass hybrid (Sorghum genus) seed through near infrared spectroscopy (NIRS). The amount of samples for develop to the best discriminant equation was 360. Whole samples were applied different three spectra range (visible, NIR and full range) within 680-2500 nm wavelength and the spectrastar 2500 Near near infrared was used to measure spectra. The calibration equation for discriminant analysis was developed partial least square (PLS) regression and discrimination equation (DE) analysis. The PLS discriminant analysis model for three spectra range developed with mathematic pretreatment 1,8,8,1 successfully discriminated 12 different sorghum genus. External validation indicated that all samples were discriminated correctly. The whole discriminant accuracy shown 82 ~ 100 % in NIR full range spectra. The results demonstrated the usefulness of NIRS combined with chemometrics as a rapid method for discrimination of sorghum × sudangrass hybrid cultivar through seed.

근적외 분광분석법을 이용한 한국산과 미국산 잎담배의 판별분석

  • 장기철;김용옥;이경구
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.20 no.2
    • /
    • pp.191-197
    • /
    • 1998
  • Discriminant analysis using near infrared spectra derived from Korean Flue-cured(KF) and American Flue-cured(AF), and also Korean Burley(KB) and American Burley(AB) tobacco was done to classify flue-cured and burley tobacco as either grown in Korea or grown in the USA. Samples were scanned in the wavelength of 400 ~ 2500 nm by near infrared analyzer(NIRSystem Co., model 6500). The discrimination equations for flue-cured and burley tobacco were developed using partial least square 2 method in Infrasoft International NIRS 3 software package. KF samples used for the development of the discrimination equations were higher contents of total sugar, crude ash and chlorine, and higher value of leaf density and brightness, but lower contents of nicotine, total nitrogen and ether extracts, and higher value of redness than those of AF samples. KB samples were higher contents of nicotine, crude ash and chlorine, but lower contents of ether extracts and value of brightness than those of AB samples. On 3 dimensional graph drawn with 3 principal component scores calculated with 3 principal component from KF and KB sample spectra, KF sample spectra were significantly different from AF, and also KB sample spectra were significantly different from AB. The discrimination equations of flue-cured and burley were developed with 3 principal component, respectively. The discrimination equations for flue-cured and burley had a standard error of 0.03 and 0.04, and a R2 of 0.88 and 0.84, respectively. The tobacco samples used for the development of discrimination equation were perfectly classified as KF and AF by flue-cured discrimination equation, and also perfectly classified KB and AB by burley discrimination equation, respectively. The correct classification rates of KF and AF samples not used for the development of discrimination equations were 9S % (828 out of 869 samples) and 98 % (98 out of 100 samples) by flue-cured discrimination equations, and KB and AB samples were 94%(345 out of 368 samples) and 100%(42 out of 42 samples) by burley discrimination equations, respectively.

  • PDF

Preparation of Spherical TiO2 Nanoparticles Using Amphiphilic PCZ-r-PEG Random Copolymer Template Membrane (양친성 PCZ-r-PEG 랜덤 공중합체 분리막을 이용한 구형 이산화티타늄 나노입자의 제조)

  • Lee, Jae Hun;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.29 no.3
    • /
    • pp.183-189
    • /
    • 2019
  • Amphiphilic PCZ-r-PEG random copolymer assisted solvothermal process is used to prepare mesoporous $TiO_2$ microspheres generated from nanoparticles by self-assembly method. Synthesized PCZ-r-PEG is characterized by Fourier transform infrared spectroscopy (FT-IR), nuclear magnetic resonance (NMR), gel permeation chromatography (GPC) and transmission electron microscopy (TEM). The mesoporous $TiO_2$ are prepared by PCZ-r-PEG, glucose, water in tertrahydrofuran solution at $150^{\circ}C$ for 12 h and the $TiO_2$ microspheres are calcined at $550^{\circ}C$ for 30 min to further crystallize and organic residue are removed. Morphology and crystallization phase is characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD) respectively. The mesoporous $TiO_2$ crystallized in pure anatase phase with diameter of $300{\pm}20nm$.

Improvement of Cloud-data Filtering Method Using Spectrum of AERI (AERI 스펙트럼 분석을 통한 구름에 영향을 받은 스펙트럼 자료 제거 방법 개선)

  • Cho, Joon-Sik;Goo, Tae-Young;Shin, Jinho
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.2
    • /
    • pp.137-148
    • /
    • 2015
  • The National Institute of Meteorological Research (NIMR) has operated the Fourier Transform InfraRed (FTIR) spectrometer which is the Atmospheric Emitted Radiance Interferometer (AERI) in Anmyeon island, Korea since June 2010. The ground-based AERI with similar hyper-spectral infrared sensor to satellite could be an alternative way to validate satellite-based remote sensing. In this regard, the NIMR has focused on the improvement of retrieval quality from the AERI, particularly cloud-data filtering method. The AERI spectrum which is measured on a typical clear day is selected reference spectrum and we used region of atmospheric window. We performed test of threshold in order to select valid threshold. We retrieved methane using new method which is used reference spectrum, and the other method which is used KLAPS cloud cover information, each retrieved methane was compared with that of ground-based in-situ measurements. The quality of AERI methane retrievals of new method was significantly more improved than method of used KLAPS. In addition, the comparison of vertical total column of methane from AERI and GOSAT shows good result.

Application of Seasonal AERI Reference Spectrum for the Improvement of Cloud data Filtering Method (계절별 AERI 기준 스펙트럼 적용을 통한 구름에 영향을 받은 스펙트럼 자료 제거방법 개선)

  • Cho, Joon-Sik;Goo, Tae-Young;Shin, Jinho
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.5
    • /
    • pp.409-419
    • /
    • 2015
  • The Atmospheric Emitted Radiance Interferometer (AERI) which is the Fourier Transform InfraRed (FTIR) spectrometer has been operated by the National Institute of Meteorological Research (NIMR) in Anmyeon island, South Korea since June 2010. The ground-based AERI with similar hyper-spectral infrared sensor to satellite could be an alternative way to validate satellite-based remote sensing. In this regard, the NIMR has focused on the improvement of Cloud data Filtering Method (CFM) which employed only one reference spectrum of clear sky in winter season. This study suggests Seasonal-Cloud data Filtering Method (S-CFM) which applied seasonal AERI reference spectra. For the comparison of applied S-CFM and CFM, the methane retrievals (surface volume mixing ratio) from AERI spectra are used. The quality of AERI methane retrieval applied S-CFM was significantly more improved than that of CFM. The positive result of S-CFM is similar pattern with the seasonal variation of methane from ground-based in-situ measurement, even if the summer season's methane is retrieved over-estimation. In addition, the comparison of vertical total column of methane from AERI and GOSAT shows good result except for the summer season.

Influence of the homogenizing grade and meathematical treatment on the determination of ground beef components with near infrared reflectance spectroscopy (식품의 근적외선 반사분광분석법에서 균질의 정도가 흡광도에 미치는 영향 및 수학적 처리방법에 관한 연구)

  • Oh, Eun-Kyong;Grossklaus, Dieter
    • Korean Journal of Food Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.408-413
    • /
    • 1992
  • This study was conducted to determine the effect of the homogenizing grade of sample on absorbance of near infrared reflectance spectrophotometer with which chemical compositions of food were rapidly and effectively analyzed. By the mathematical treatment of absorbance values standard error of prediction was reduced as follows. 1. The absorbance values of various samples ground for the same periods of time were calibrated before or after treatment with first or second derivative in an attempt to accurately predict the components of samples ground for the different periods of time. The standard error of prediction for moisture content were 1.478%, 0.658% and 0.580%, respectively, those for fat content 0.949%, 0.637% and 0.527%, respectively, and those for protein content 0.514%, 0.493% and 0.394%, respectively. Calibration of absorbance values after second derivative treatment showed the highest accuracy in predicting sample components. 2. The absorbance values of various samples ground for the different periods of time were calibrated before or after treatment with first or second derivative in order to accurately predict the components of samples ground for the different periods of time. The standard error of prediction for moisture content were 1.026%, 0.589% and 0.568%, respectively, and those for protein content 0.860%, 0.557% and 0.399%, respectively. The standard error of prediction were lower in the order of calibrations before and after first and second derivative treatments. As a result, calibration of absorbance values after second derivative treatment showed higher accuracy regardless of grinding time of samples.

  • PDF

Measurement of lipid content of compost fermentation using near-infrared spectroscopy

  • Daisuke Masui;Suehara, Ken-ichiro;Yasuhisa Nakano;Takuo Yano
    • Near Infrared Analysis
    • /
    • v.2 no.1
    • /
    • pp.37-42
    • /
    • 2001
  • Near infrared spectroscopy (NIRS) was applied to determination of the lipid content of the compost during the compost fermentation of tofu (soybean0curd) refuse. The absorption of lipid observed at 5 wavelengths, 1208, 1712, 1772, 2312 and 2352 nm on the second derivative spectra. To formulated a calibration equation, a multiple linear regression analysis was carried out between the near-infrared spectral data and on the lipid content in the calibration sample set (sample number, n=60) obtained using Soxhlet extraction method. The value of the multiple correlation coefficient (R) was 0.975 when using the wavelengths of 1208 and 1712 nm were used in the calibration equation. To validate the calibration equation obtained, the lipid content in the validation sample set (n=35) not used for formulating the calibration equation was calculated using the calibration equation, and compared with the value obtained using the Soxhlet extraction method. Good agreement was observed between the results of the Soxhlet extraction method and those values of the NIRS method. The simple correlation coefficient (r) and standard error of prediction (SEP) were 0.964 and 0.815 %, respectively. suitability of the lipid content as an indicator of the compost fermentation of tofu refuse was also studied. The decrease of the lipid content in the compost corresponded to the decrease of the total dry weight of the compost in the composter. The lipid content was a significant indicator of the compost fermentation. The NIRS method was applied to measure the time course of the lipid content in the compost fermentation and good results were obtained. The study indicates that NIRS is a useful method for process management of the compost fermentation of tofu refuse.