• Title/Summary/Keyword: 적분 이득

Search Result 101, Processing Time 0.023 seconds

Design of a permanent magnetic synchronous motor speed servo controller using on-line tuning PI control method (온라인 동조 PI 제어기법을 이용한 영구자석형 동기전동기의 속도 제어기 설계)

  • Jun, In-Hyo;Im, Sang-Duck;Choi, Jung-Keyng;Park, Seung-Yub
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.12
    • /
    • pp.36-45
    • /
    • 1998
  • In this paper, a method of on-line PI gain-tuninng is proposed for the speed control of brushless D.C. motor by investigating the pattern of input and output without estimating parameter. Proportional gain is tuned in the process to obtain a fast speed response by supplying the maximum constant input. And integral gain is appropriately tuned in the process of proportional control so that the response may be stably converged and the overshoot may be prevented. Therefore because both control and gain-tuning are executed concurrently, additional works that estimate parameters and so on aren't required in the proposed method. In the proposed method, both fast-response and overshoot problem are well solved, and it is more useful and convenient than existing auto-tuning methods in the speed control of D.C. motor. It is illustrated by simulations and experimental results that the proposed method is useful and stable.

  • PDF

A fast transient control of EDPA gain on channel add/drop WDM networks (채널 가감 파장분할다중(WDM)망에서 EDFA 이득의 빠른 과도 응답 제어)

  • Park Jungmoon;Lee Sangheon;Shin Seoyong;Song Seongho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.4A
    • /
    • pp.233-240
    • /
    • 2005
  • In this paper, we have shown the gain recovery time of erbium-doped fiber amplifier(EDFA) in WDM add/drop networks can be reduced to less than $3\mu$sec by employing disturbance observer technique with PID controller which is based on 3-level EBFA model. The $3\mu$sec transient time is the fastest one ever reported and it is about $1\%$ of $250\mu$sec previously obtained from disturbance observer technique with PI controller which was based on 2-level EDFA model and it is also less than $200\mu$sec of commercially available EDFAs for WDM networks. We were able to obtain this result by analyzing various system characteristics as we change the parameters of disturbance observer and PID controller. If this result is applied to a commercial product, the product will do an important role in the future dynamic WDM networks.

Weighted Integral H Control of Induction Motor using T-S fuzzy (T-S 퍼지를 사용한 유도전동기의 가중적분 H 제어)

  • Kim, Min-Chan;Park, Seung-Kyu;Yoon, Tae-Sung;Kwak, Gun-Pyong;Ahn, Ho-Gyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.6
    • /
    • pp.1399-1408
    • /
    • 2013
  • This paper proposes a new $H_{\infty}$ T-S fuzzy controller with a novel integral control for induction motors which have nonlinear dynamics. The $H_{\infty}$ T-S fuzzy controller is used for the nonlinearity and robustness and weighted integral is used for tracking problem and control performance. A T-S Fuzzy controller is the fuzzy combination of local linear controllers considering the overall stability, and LMI(Linear Matrix Inequlity) is used for determining the gains of linear controllers. The tracking problem of an induction motor is changed into regulator problem by introducing the integral control technique with weighting factor, diminishing the conservatism of $H_{\infty}$ T-S fuzzy controller.

Investigation of miximum permitted error limits for second order sigma-delta modulator with 14-bit resolution (14 비트 분해능을 갖는 2차 Sigma-Delta 변조기 설계를 위한 구성요소의 최대에러 허용 범위 조사)

  • Cho, Byung-Woog;Choi, Pyung;Sohn, Byung-Ki
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.5
    • /
    • pp.1310-1318
    • /
    • 1998
  • Sigma-delta converter is frequently used for conyerting low-frequency anglog to digital signal. The converter consists of a modulator and a digital filer, but our work is concentrated on the modulator. In this works, to design second-order sigma-dalta modulator with 14bit resolution, we define maximumerror limits of each components (operational smplifier, integrator, internal ADC, and DAC) of modulator. It is first performed modeling of an ideal second-order sigma-delta modulator. This is then modified by adding the non-ideal factors such as limit of op-amp output swing, the finit DC gain of op-amp slew rate, the integrator gian error by the capacitor mismatch, the ADC error by the cmparator offset and the mismatch of resistor string, and the non-linear of DAC. From this modeling, as it is determined the specification of each devices requeired in design and the fabrication error limits, we can see the final performance of modulator.

  • PDF

Correction on Current Measurement Errors for Accurate Flux Estimation of AC Drives at Low Stator Frequency (저속영역에서 교류전동기의 정확한 자속추정을 위한 전류측정오차 보상)

  • Cho, Kyung-Rae;Seok, Jul-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.65-73
    • /
    • 2007
  • This paper presents an on-line correction method of current measurement errors for a pure-integration-based flux estimation down to 1-Hz stator frequency. An observer-based approach is taken as one possible solution of eliminating the dc offset and the negative sequence component of unbalanced gains in the synchronous coordinate. At the same time, the positive sequence component estimation is performed by creating an error signal between a motor model reference and an estimated q-axis rotor flux established by a permanent magnet (PM) in the synchronous coordinate. The compensator utilizes a PI controller that controls the error signal to zero. The proposed technique further contains a residual error compensator to completely eliminate miscellaneous disturbances in the estimated flux. The developed algorithm has been implemented on a 1.1-kW permanent magnet synchronous motor (PMSM) drive to confirm the effectiveness of the proposed scheme.

A Study on the State feedback with Integral Control for a Variable Air Volume Unit (가변 풍량 유닛에 대한 적분기를 가진 상태 궤환 제어에 관한 연구)

  • 박세화
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.2
    • /
    • pp.9-14
    • /
    • 2000
  • State feedback with integral control for a variable air volume(VAV) unit which is recently taken notice of for the energy efficiency and saving in the building is studied to investigate the performance of the digital control methodology for the possible practical application. The digital controller which acquires the targat zone temperature and the air flow rate of the supplied air to the zone controls the opening of the damper in the VAV unit. Simulation results are performed for the conditions including reference changes and external thermal variations. In the simulation. simplified conditioned zone and the damper actuator modelling is considered. and relationships between controller gain Parameters and the system dynamics are investigated.

  • PDF

Current Regulated Delta Modulator for Series Resonant Inverter with Transformer-Coupled Load (변압기-결합형 직렬공진 인버터의 델타변조 전류제어)

  • 안희욱;김학성
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.231-239
    • /
    • 1999
  • An improved version of current-regulated delta modulator (CRDM) is investigated for the output cunent control of v voltage-source inverters that have transformer-coupled series resonant load and are operated at the resonant frequency. Conventional CRDM has not only CUlTent offset problem but also transformer flux saturation problem when i it is applied to induction heating systems that have transformel-coupled loads. To cope with these problems, the effect of flux saturation is analysed, and simple method to av이d the problem is proposed. And integral type of CRDM is a adopted to remove the cunent offset. The boundaries of integrator gain for stable operation is calculated using the c concept of sliding mode controL The validity of proposed strategy is vel퍼ed through simulations and prototype e experiments.

  • PDF

Comparison of PI and PR Controller Based Current Control Schemes for Single-Phase Grid-Connected PV Inverter (단상 계통 연계형 태양광 인버터에 사용되는 PI 와 PR 전류제어기의 비교 분석)

  • Vu, Trung-Kien;Seong, Se-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2968-2974
    • /
    • 2010
  • Nowadays, the PV systems have been focused on the grid connection between the power source and the grid. The PV inverter can be considered as the core of the whole system because of an important role in the grid-interfacing operation. An important issue in the inverter control is the load current regulation. In the literature, Proportional Integral (PI) controller, which is normally used in the current-controlled Voltage Source Inverter (VSI), cannot be a satisfactory controller for an AC system because of the steady-sate error and the poor disturbance rejection, especially in high-frequency range. Compared with conventional PI controller, Proportional Resonant (PR) controller can introduce an infinite gain at the fundamental frequency of the AC source; hence it can achieve the zero steady-state error without requiring the complex transformation and the de-coupling technique. Theoretical analyses of both PI and PR controller are presented and verified by simulation and experiment. Both controller are implemented in a 32-bit fixed-point TMS320F2812 DSP processor and evaluated on a 3kW experimental prototype PV Power Conditioning System (PCS). Simulation and experimental results are shown to verify the controller performances.

A Design of Multi-band Antenna using asymmetric Bow-tie structure (비대칭 보우 타이 구조를 이용한 다중 대역 안테나 설계)

  • Jang, Jeong-Seok;Kim, Dae-Woong;Choi, Yong-Gyu;Hong, Ui-Seok
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.2
    • /
    • pp.41-50
    • /
    • 2010
  • In this paper, a multi-band antenna with novel structure for mobile communications is designed and fabricated. The proposed antenna has the Multi-band antenna characteristics by two common-grounded slots with different size and angle. In order to reduce size and to enhance the gain of the antenna, a reflector is consisted of chokes on the three sides. It is optimized by using the CST Microwave Studio commercial software based on the FIA(Finite Integration Algorithm) and PBA(Perfect Boundary Approximation), and then the fabricating and measuring is practiced. As a result of measurement, the reflection coefficient is less than -11 dB(VSWR < 1.8) and the gain of antenna is more than 6dBi at 824~894MHz and 1885-2500MHz.

PID Controller and Derivative-feedback Gain Design of the Direct-drive Servo Valve Using the Root Locus and Manual Tuning (근궤적과 수동 조정에 의한 직접 구동형 서보밸브의 PID 제어기 및 미분피드백 이득 설계)

  • Lee, Seong Rae
    • Journal of Drive and Control
    • /
    • v.13 no.3
    • /
    • pp.15-23
    • /
    • 2016
  • The direct-drive servo valve(DDV) is a kind of one-stage valve because the main spool valve is directly driven by the dc motor. Since the DDV structure is simple, it is less expensive, more reliable, and offers a reduced internal leakage and a reduced sensitivity to fluid contamination. The control system of the DDV is highly nonlinear due to a current limiter, a voltage limiter, and the flow-force effect on the spool motion. The shape of the step response of the DDV-control system varies considerably according to the magnitudes of the step input and the load pressure. The system-design requirements mean that the overshoots should be less than 20%, and the errors at 0.02s should be less than 2%, regardless of the reference-step input sizes of 1V and 5V and the load-pressure magnitudes of 0MPa and 20.7MPa. To satisfy the system-design requirements, the PID-controller parameters of $K_c$, $T_i$ and $T_d$, and the derivative-feedback gain of $K_{der}$ are designed using the root locus and manual tuning.