• Title/Summary/Keyword: 저항 성능

Search Result 2,109, Processing Time 0.025 seconds

Estimation of Ship Resistance by Statistical Analysis and its Application to Hull Form Modification (통계해석에 의한 저항 추정 및 선형 개량)

  • S.W.,Hong;K.J.,Cho;D.S.,Yun;E.C.,Kim;W.C.,Jung
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.25 no.4
    • /
    • pp.28-38
    • /
    • 1988
  • This paper describes the statistical analysis method of predicting the ship resistance. The equation for the wavemaking resistance coefficient is derived as the principal dimensions and sectional area coefficients by using the wavemaking resistance theory and its regression coefficients are determined from the regression analysis of the resistance test results. The equation for the form factor is derived by purely regression analysis of the principal dimensions, sectional area coefficients and resistance test results. Also, it is shown that the wavemaking resistance can be minimize by varying the sectional area curve without changing the principal dimensions of the ship. This methods were applied to the resistance prediction of a bulk carrier. And the, the modified hull form with minimum wavemaking resistance was obtained and the reduction of effective power was confirmed by the resistance test.

  • PDF

Optimizing the Configurations of Cooling Channels with Low Flow Resistance and Thermal Resistance (냉각유로 형상변화에 따른 유동 및 열저항 최적화 연구)

  • Cho, Kee-Hyeon;Ahn, Ho-Seon;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.1
    • /
    • pp.9-15
    • /
    • 2011
  • In this study, we investigated the hydrodynamic and thermal performance of constructal architectures on the basis of the mass flow rates for a given pressure drop, and we determined the thermal resistance and flow uniformity. The five flow configuration used in this study were the first construct with optimized hydraulic diameter, the second construct with optimized hydraulic diameter, the first construct with non-optimized hydraulic diameter, second construct with non-optimized hydraulic diameter, and a serpentine configuration. The results of our study suggest that the best fluid-flow structure is the second constructal structure with optimized constructal configurations. We also found that in the case of the optimized structure of cooling plates, the heat transfer was remarkably higher and the pumping power was significantly lower than those of traditional channels.

The Elementary Study on the Development for Test Methods of Load Resistance about Attachments on the Lightweight Wall (경량벽체의 부착물에 대한 하중저항성 평가방법 개발을 위한 기초적 연구)

  • Kim, Sang-Heon;Kim, Se-Whan;Choi, Soo-Kyung;Seo, Chee-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.119-126
    • /
    • 2015
  • The wall system has been also tending to shift from existing concrete wall to variable lightweight wall according to increasing use of column structure system in apartment construction. Therefore, wall needs certain amount of strength which also means the standard measurement of resistance against loading of wall attachments is needed. Nevertheless, there currently aren't enough researches of related standards for such measurement. For such reason, the research would be used as baseline data to development for test methods of load resistance about attachments on the lightweight wall, that presented improvements in the apparatus and maximum loads for domestic circumstances by researching current tests.

Influences of the Surface Pollution Cause by the Marine Growth on Ship Hulls on Engine Performance and Output (선체 해양생물의 선저오염이 엔진성능과 출력에 미치는 영향)

  • Jung, Kyun-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.399-404
    • /
    • 2015
  • The cost of fuel in ships has recently increased due to a rapid increase in international oil prices and international restrictions regarding the greenhouse effect generated from the burning of fuel. Therefore, different methods for changing the hull designs for improving energy efficiency, developing coating for reducing friction resistances, developing additives for improving engine thermal efficiency, and low-speed operation for reducing fuel consumption have been considered. The developments of high-speed, large-scale, and energy-saving vessels are deemed essential to adapt to the recent high oil price era. Therefore, it is important to analyze Precisely the qualitative and quantitative changes in the resistance value of the local areas of the hull surface. In this study, the engine performance before and after docking was analyzed to examine friction resistance caused by marine growth on the hull as a basic study for improving the energy efficiency. The result was then presented by comparing it with the previous data for 2.5 years between docks to investigate the performance of the main engine, the change in friction resistances and loads, the fuel consumption and ship speed.

A Study on the Anti-corrosion Properties of Organic and Inorganic Inhibitor by Electrochemical Evaluation Method in Saturated Aqueous Solution of Calcium Hydroxide (포화 수산화칼슘 수용액 내에서의 무기계 및 유기계 방청제의 전기화학적 방식 특성평가)

  • Kim, Soo-Young;Ryu, Hwa-Sung;Kim, Sung-Kil;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.66-74
    • /
    • 2013
  • In this study, corrosion potential ($E_{corr}$), corrosion rate, and polarization resistance were measured aimed at inorganic inhibitors (passive film type) and organic inhibitors (absorption type). The experiment was conducted using potentiostat for the variable molar ratio and chloride ion concentration of the components of inhibitors in an aqueous solution of saturated calcium hydroxide targeting corrosion. As a result, it was possible to ensure an anticorrosive performance of at least a 1.2 molar ratio of inorganic inhibitors. Also, the organic inhibitors ensured the prevention of the anticorrosive performance of at least about a 0.3 molar ratio. It also showed the tendency that between polarization resistance and corrosion rate, Ecorr and corrosion rate is inversely proportional to the linear. Conversely, the tendency between polarization resistance and Ecorr is proportional to the linear. Also, a distinct difference in organic and inorganic inhibitors' relationship to Ecorr, corrosion rate, and polarization resistance was not shown.

Design and Performance Prediction of μN Level MEMS Thrust Measurement System of Piezoresistance Method (압저항 방식의 μN급 MEMS 추력 측정 시스템 설계 및 성능 예측)

  • Ryu, Youngsuk;Lee, Jongkwang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.111-117
    • /
    • 2018
  • In this study, an MEMS thrust measurement system was designed and a study on the performance prediction of system was performed to evaluate the performance of micro thruster. Thrust measurement system consists of beam, membrane, and piezoresistive sensor. An FEM analysis was carried out to verify the stability of the system, confirm the stress variation at the beam, and position the piezoresistive sensor. The stability of the designed system was verified by comparing the yield strength of the material with the maximum stress. The piezoresistive sensor was designed to be 20% of the length of the beam to obtain a high gauge factor. The size of the membrane and the beam of the reference model were designed to be $15mm{\times}15mm$, and $500{\mu}m{\times}500{\mu}m$, respectively.

A Study on the Erosion Resistance Performance of Biopolymer Mixed Soils According to Soil Types (토양 종류에 따른 바이오폴리머 혼합토의 침식저항 성능 연구)

  • Kim, Myounghwan;Lee, Du Han
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.221-221
    • /
    • 2021
  • 토양의 강도와 점성을 높여주는 바이오폴리머를 제방 호안에 도포하면 기존의 다른 호안 재료들과 마찬가지로 제방을 보호하는 것이 가능하다. 특히 바이오폴리머는 천연 토양과 혼합하여 사용하므로 다른 인공적인 호안재료들에 비해 생태적으로 유리하다. 하지만 바이오폴리머는 결합되어지는 토양의 점도, 공극률, 입도 등의 토양이 가지는 특성에 따라 성능이 변화하기 때문에 바이오폴리머를 이용한 혼한토를 제방 호안에 적용하기 위해서는 적절한 강도를 가지게 하는 토양을 선정해야 한다. 본 연구에서는 바이오폴리머를 마사토 및 황토 등과 결합하여 시험구를 설치하고 식생환경을 조성한 뒤 실규모 실험수로에서 수리 실험을 수행하여 바이오폴리머를 이용한 호안 공법의 침식 저항 성능을 평가하고 토양의 종류에 따라 성능을 비교하였다.

  • PDF

Assessment of Impact Resistance Performance of Post-tensioned Curved Wall using Numerical Impact Analysis (긴장력이 도입된 곡면벽체의 충돌저항성능 수치해석평가)

  • Chung, Chul-Hun;Lee, Jungwhee;Jung, Raeyoung;Yu, Tae-Yong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.2
    • /
    • pp.161-167
    • /
    • 2016
  • In this study, the effect of wall curvature and post-tension force on impact resistance is evaluated by numerical analysis method. A total of twelve cases with two parameters such as wall shape of flat and curved, and consideration of post-tensioning force were included in this study. A 3D detailed finite element model of commercial passenger plane engine is utilized as projectile. The depths of penetration and central displacement calculated from the numerical simulations were compared and analysed. As the results of the numerical simulations of this study, penetration depth was reduced approximately 60~80% due to the application of post-tension force, but the decrease of maximum central displacement was not remarkable. Also, the effect of curvature was relatively insignificant.

An Evaluation of Blast Resistance Performance of RC Columns According to the Shape of Cross Section (단면의 형상에 따른 철근콘크리트 기둥의 폭발저항 성능 평가)

  • Kim, Han-Soo;Park, Jae-Pyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.4
    • /
    • pp.387-394
    • /
    • 2010
  • The alternative load path method based on a column removal scenario has been commonly used to protect building structures from being progressively collapsed due to probable blast loading. However, this method yields highly conservative result when the columns still have substantial load resisting capacity after blast. In this study, the behavior of RC columns with rectangular and circular sections under the blast loading was investigated and the remaining capacity of the partially damaged columns was compared. AUTODYN which is a hydrocode for the analysis of the structure on the impact and blast loading was used for this study. The blast loading was verified with the experiment results. The analysis results showed that the circular columns are preferable to the rectangular ones in respect of the blast resistance performance.