• Title/Summary/Keyword: 저저압

Search Result 53, Processing Time 0.029 seconds

Evaluation on Insulation Performance of Traction Motors for a Hybrid Vehicle by Partial Discharge Measurement (부분방전 측정에 의한 하이브리드차량 견인전동기의 절연성능평가)

  • Park, Dae-Won;Park, Chan-Yong;Choi, Jae-Sung;Kil, Gyung-Suk;Lee, Kang-Won
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.2
    • /
    • pp.249-253
    • /
    • 2009
  • This paper dealt with the insulation evaluation by a measurement of partial discharge(PD) on traction motors used in a hybrid vehicle. The PD method has been accepted as an effective and a non-destructive. technique to evaluate insulation performance of low-voltage electric and electronic devices. In this paper, the PD measurement system which was manufactured with a coupling network, a low noise amplifier, and an associated electronics is described. The PD measurement system has the frequency bandwidth of $1[MHz]{\sim}30[MHz]$ at -3 [dB] and the stable sensitivity of 19 [mV/pC] for the traction motor. From the experimental results, discharge inception voltage (DIV) and apparent charge (q) were $1,100[V_{rms}]$ and 105 [pC] for the used motor, and $1,400[V_{rms}]$ and 84 [pC] for the new one. By comparing the DIV and q, we could evaluate the insulation condition for the traction motors.

Development of a Direct-Connected Supersonic Combustor Test Facility (직결형 초음속 연소기 시험 설비 개발)

  • Yang, Inyoung;Lee, Kyung-jae;Lee, Yang-ji;Kim, Hyung-Mo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.290-293
    • /
    • 2017
  • A direct-connected, continuous type combustion test facility was developed to test a supersonic combustor model used in scramjet engines. The facility requirements were determined by assuming the flight speed of Mach 5, yielding the combustor inlet flow speed of Mach 2. Also the cross-section of the supersonic combustor under test was assumed as $32mm{\times}70mm$. As a result, the facility was designed to have the flow total pressure of 548 kPaA, total temperature of 1,320 K, and flow rate of 0.776 kg/s. The facility consists of a turbo type air compressor, electric air heater, vitiation air heater and a two dimensional facility nozzle to accelerate the flow to Mach 2. Also, an oxygen supply system was added to compensate the vitiation. The exhaust de-pressurization system is not added. Designed pressure, temperature, and flow rate were verified through the test operation of the facility.

  • PDF

Changes of Electrical Characteristics of Low-voltage ZnO Varistors by a lightning Impulse Current (뇌충격전류에 의한 저압용 산화아연형 바리스터의 전기적 특성변화)

  • 이종혁;한주섭;길경석;권장우;송동영;최남섭
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.4
    • /
    • pp.793-801
    • /
    • 2000
  • This paper presents the effect of lightning impulse current on ZnO varistors(390[V], 6.5[kA]) used in low-voltage AC mains as a protective device against transient overvoltages. The electrical characteristics of ZnO varistors are deteriorated by overtime impulse current, and a deteriorated ZnO varistor is brought to a thermal runaway and finally destroyed even in normal operating voltage. Therefore, it is important to estimate the changes of the electrical characteristics of ZnO varistors. A lightning impulse current standardized in IEC 61000-4-5 is applied to the varistors to accelerate deterioration, and the energy applied to the varistor at each time is about 12 [J]. In the experiment, various parameters such as leakage current, reference voltage are measured with the number of applied impulse current. Also, micro-structure changes of the varistors after applying the lightning impulse current of 200 times are compared. The electrical characteristics of the varistors are degraded by overtime impulse current, showing increase in leakage current and decrease in reference voltage.

  • PDF

Effects of growth interruption on the photoluminescence characteristics of InGaAs/InP quantum wells (성장정지효과에 의한 InGaAs/InP 양자우물구조의 Photoluminescence 특성 변화)

  • 문영부;이태완;김대연;윤의준;유지범
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.2
    • /
    • pp.104-111
    • /
    • 1998
  • The InGaAs/InP quantum wells(QWs) were grown by low pressure metalorganic chemical vapor deposition and the effects of growth interruption steps on their interfacial structures were investigated by measuring photoluminescence spectra. When InP or InGaAs surface was treated under the same group V ambient, the full width at half maximum (FWHM) of the QW peak increased possibly due to the incorporation of impurities during the growth interruption time. When InP surface was treated under $AsH_3$, howerer, the PL peak showed red-shift due to the As-P exchange reaction and the change of FWHM was not remarkable. The effective thickness of InAs interfacial layer formed during $AsH_3$, treatment on the InP surface was calculated to be 1~2 monolayers. In the case of InGaAs treatment under $PH_3$, the PL peak energy and the FWHM increasied. This results suggest that $PH_3$ treatment on the InGaAs surface suppresses the incorporation of As into the subsequent InP layer and the local replacement of As by P occurs simultaneously.

  • PDF

Distribution of Precipitation on the Korean Peninsula Associated with the Weakening of Tropical Cyclones (태풍의 약화와 관련된 한국의 강수량 분포)

  • Hwang, Ho-Seong;Byun, Hi-Ryong;Lee, Sang-Min;Choi, Ki-Seon;Lee, Ji-Sun
    • Journal of the Korean earth science society
    • /
    • v.31 no.4
    • /
    • pp.322-334
    • /
    • 2010
  • Spatiotemporal characteristics of precipitation in Korea, associated with the weakening of Tropical Cyclones (TCs) around the Korean Peninsula ($32-36^{\circ}N$, $122-132^{\circ}E$) over the last 30 years (1979-2008), were investigated. Weakened TCs are classified as WEC (Weakened to Extratropical Cyclone) and WTD (Weakened to Tropical Depression). In WEC, precipitation was evenly distributed all over the Korean Peninsula and the greater precipitation was recorded in the southern coast. In WTD, the most precipitation was recorded in the southern coast but low precipitation was recorded in the central and inland areas of Korea. The difference of precipitation between WEC and WTD was not statistically significant in Region 2 (Jeollanam-do, Gyeongsangnam-do, southeastern part of Gyeongsangbuk-do, Jeju-do); however, the precipitation resulting from WEC was greater than that resulting from WTD in Region 1 (central area of Korea, Jeollabuk-do, inland of Gyeongsangbuk-do). In WEC, the developed upper-level potential vorticity (PV) and low-level temperature trough shifted to the northwest of TCs approaching Korea. In addition, an upper-level jet stream and strong divergence field were observed to the northeast of the TCs. It was assumed that these meteorological factors had induced baroclinic instability and diabatic process, which created a large precipitation area around the TCs. However, the intense PV, temperature trough, jet stream were not observed in WTD, which created a small precipitation area around the TCs.

Effects of time compression on auditory working memory and decision making process in normal hearing subjects (시간 압축이 청각 작업기억과 의사 결정 과정에 미치는 영향)

  • Lim, Dukhwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.1
    • /
    • pp.64-69
    • /
    • 2022
  • Background music is presented simultaneously with target messages. The main content should be kept intact for some time to aid decision making process. The maintenance of this information requires auditory working memory. The temporal compression of background music may often adopted due to the limitation of the presentation time. In this study, auditory working memory and decision making proces were analyzed in terms of temporal compression ratios of the background music. A total of 37 subjects of early twenties joined the study. Selected products were categorized based on eigen values of multi-dimensional scaling. Four presentation conditions were cases with no background music, background music with no compression, background music with low compression, and background music high compression. Matched reponses were analyzed through repeated ANOVA. Results showed that the high involvement product required more working memory resources. However, the increased level of usage did not always lead to the corresponding changes in decision making process. This approach may be useful in analyzing the role of time compression and working memory in consumer behaviors.

Forward Osmotic Pressure-Free (△𝜋≤0) Reverse Osmosis and Osmotic Pressure Approximation of Concentrated NaCl Solutions (정삼투-무삼투압차(△𝜋≤0) 법 역삼투 해수 담수화 및 고농도 NaCl 용액의 삼투압 근사식)

  • Chang, Ho Nam;Choi, Kyung-Rok;Jung, Kwonsu;Park, Gwon Woo;Kim, Yeu-Chun;Suh, Charles;Kim, Nakjong;Kim, Do Hyun;Kim, Beom Su;Kim, Han Min;Chang, Yoon-Seok;Kim, Nam Uk;Kim, In Ho;Kim, Kunwoo;Lee, Habit;Qiang, Fei
    • Membrane Journal
    • /
    • v.32 no.4
    • /
    • pp.235-252
    • /
    • 2022
  • Forward osmotic pressure-free reverse osmosis (Δ𝜋=0 RO) was invented in 2013. The first patent (US 9,950,297 B2) was registered on April 18, 2018. The "Osmotic Pressure of Concentrated Solutions" in JACS (1908) by G.N. Lewis of MIT was used for the estimation. The Chang's RO system differs from conventional RO (C-RO) in that two-chamber system of osmotic pressure equalizer and a low-pressure RO system while C-RO is based on a single chamber. Chang claimed that all aqueous solutions, including salt water, regardless of its osmotic pressure can be separated into water and salt. The second patent (US 10.953.367B2, March 23, 2021) showed that a low-pressure reverse osmosis is possible for 3.0% input at Δ𝜋 of 10 to 12 bar. Singularity ZERO reverse osmosis from his third patent (Korea patent 10-22322755, US-PCT/KR202003595) for a 3.0% NaCl input, 50% more water recovery, use of 1/3 RO membrane area, and 1/5th of theoretical energy. These numbers come from Chang's laboratory experiments and theoretical analysis. Relative residence time (RRT) of feed and OE chambers makes Δ𝜋 to zero or negative by recycling enriched feed flow. The construction cost by S-ZERO was estimated to be around 50~60% of the current RO system.

Preparation of poly-crystalline Si absorber layer by electron beam treatment of RF sputtered amorphous silicon thin films (스퍼터링된 비정질 실리콘의 전자빔 조사를 통한 태양전지용 흡수층 제조공정 연구)

  • Jeong, Chaehwan;Na, Hyeonsik;Nam, Daecheon;Choi, Yeonjo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.81-81
    • /
    • 2010
  • 유리기판위에 큰 결정입자를 갖는 실리콘 (폴리 실리콘) 박막을 제조하는 것은 가격저가화 및 대면적화 측면 같은 산업화의 높은 잠재성을 가지고 있기 때문에 그동안 많은 관심을 가지고 연구되어 오고 있다. 다양한 방법을 이용하여 다결정 실리콘 박막을 만들기 위해 노력해 오고 있으며, 태양전지에 응용하기 위하여 연속적이면서 10um이상의 큰 입자를 갖는 다결정 실리콘 씨앗층이 필요하며, 고속증착을 위해서는 (100)의 결정성장방향 등 다양한 조건이 제시될 수 있다. 다결정 실리콘 흡수층의 품질은 고품질의 다결정 실리콘 씨앗층에서 얻어질 수 있다. 이러한 다결정 실리콘의 에피막 성장을 위해서는 유리기판의 연화점이 저압 화학기상증착법 및 아크 플라즈마 등과 같은 고온기반의 공정 적용의 어려움이 있기 때문에 제약 사항으로 항상 문제가 제기되고 있다. 이러한 관점에서 볼때 유리기판위에 에피막을 성장시키는 방법으로 많지 않은 방법들이 사용될 수 있는데 전자 공명 화학기상증착법(ECR-CVD), 이온빔 증착법(IBAD), 레이저 결정화법(LC) 및 펄스 자석 스퍼터링법 등이 에피 실리콘 성장을 위해 제안되는 대표적인 방법으로 볼 수 있다. 이중에서 효율적인 관점에서 볼때 IBAD는 산업화측면에서 좀더 많은 이점을 가지고 있으나, 박막을 형성하는 과정에서 큰 에너지 및 이온크기의 빔 사이즈 등으로 인한 표면으로의 damages가 일어날 수 있어 쉽지 않는 방법이 될 수 있다. 여기에서는 이러한 damage를 획기적으로 줄이면서 저온에서 결정화 시킬 수 있는 cold annealing법을 소개하고자 한다. 이온빔에 비해서 전자빔의 에너지와 크기는 그리드 형태의 렌즈를 통해 전체면적에 조사하는 것을 쉽게 제어할 수 있으며 이러한 전자빔의 생성은 금속 필라멘트의 열전자가 아닌 Ar플라즈마에서 전자의 분리를 통해 발생된다. 유리기판위에 흡수층 제조연구를 위해 DC 및 RF 스퍼터링법을 이용한 비정질실리콘의 박막에 대하여 두께별에 따른 밴드갭, 캐리어농도 등의 변화에 대하여 조사한다. 최적의 조건에서 비정질 실리콘을 2um이하로 증착을 한 후, 전자빔 조사를 위해 1.4~3.2keV의 다양한 에너지세기 및 조사시간을 변수로 하여 실험진행을 한 후 단면의 이미지 및 결정화 정도에 대한 관찰을 위해 SEM과 TEM을 이용하고, 라만, XRD를 이용하여 결정화 정도를 조사한다. 또한 Hall효과 측정시스템을 이용하여 캐리어농도, 이동도 등을 각 변수별로 전기적 특성변화에 대하여 분석한다. 또한, 태양전지용 흡수층으로 응용을 위하여 dark전도도 및 photo전도도를 측정하여 광감도에 대한 결과가 포함된다.

  • PDF

Crystallization properties of amorphous silicon thin films by electron beam exposing method for solar cell applications (태양전지 응용을 위한 E-beam 조사법에 의한 비정질 실리콘 결정화 특성연구)

  • Jeong, Chaehwan;Ryu, Sang;Kim, Changheon;Lee, Jong-Ho;Kim, Ho-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.80-80
    • /
    • 2010
  • 유리기판위에 큰 결정입자를 갖는 실리콘 (폴리 실리콘) 박막을 제조하는 것은 가격저가화 및 대면적화 측면 같은 산업화의 높은 잠재성을 가지고 있기 때문에 그동안 많은 관심을 가지고 연구되어 오고 있다. 다양한 방법을 이용하여 다결정 실리콘 박막을 만들기 위해 노력해 오고 있으며, 태양전지에 응용하기 위하여 연속적이면서 10um이상의 큰 입자를 갖는 다결정 실리콘 씨앗층이 필요하며, 고속증착을 위해서는 (100)의 결정성장방향 등 다양한 조건이 제시될 수 있다. 다결정 실리콘 흡수층의 품질은 고품질의 다결정 실리콘 씨앗층에서 얻어질 수 있다. 이러한 다결정 실리콘의 에피막 성장을 위해서는 유리기판의 연화점이 저압 화학기상증착법 및 아크 플라즈마 등과 같은 고온기반의 공정 적용의 어려움이 있기 때문에 제약 사항으로 항상 문제가 제기되고 있다. 이러한 관점에서 볼때 유리기판위에 에피막을 성장시키는 방법으로 많지 않은 방법들이 사용될 수 있는데 전자 공명 화학기상증착법(ECR-CVD), 이온빔 증착법(IBAD), 레이저 결정화법(LC) 및 펄스 자석 스퍼터링법 등이 에피 실리콘 성장을 위해 제안되는 대표적인 방법으로 볼 수 있다. 이중에서 효율적인 관점에서 볼때 IBAD는 산업화측면에서 좀더 많은 이점을 가지고 있으나, 박막을 형성하는 과정에서 큰 에너지 및 이온크기의 빔 사이즈 등으로 인한 표면으로의 damages가 일어날 수 있어 쉽지 않는 방법이 될 수 있다. 여기에서는 이러한 damage를 획기적으로 줄이면서 저온에서 결정화 시킬 수 있는 cold annealing법을 소개하고자 한다. 이온빔에 비해서 전자빔의 에너지와 크기는 그리드 형태의 렌즈를 통해 전체면적에 조사하는 것을 쉽게 제어할 수 있으며 이러한 전자빔의 생성은 금속 필라멘트의 열전자가 아닌 Ar플라즈마에서 전자의 분리를 통해 발생된다. 유리기판위에 다결정 실리콘 씨앗층을 제조하기 위하여 전자빔을 조사하는 방법과 Al을 이용한 씨앗층 제조법이 비교되어 공정 수행이 이루어진다. 우선, 전자빔 조사를 위해 DC 및 RF 스퍼터링법을 이용하여 ${\sim}10^{20}cm^{-3}$이상의 농도를 갖는 $p^+^+$ 비정질 실리콘 박막을 제조한다. Al의 증착은 DC 스퍼터링법을 이용하여 제조하고 그 두께는 실리콘 박막의 두께와 동일한 조건(350nm)으로 제조한다. 제조된 샘플은 E-beam gun이 달린 챔버로 이동하여 1.4keV의 세기를 가지고 각각 10, 20, 50, 100초를 조사한 후 단면의 이미지를 SEM으로, 결정화 정도를 Raman으로, 결정화 방향 등에 대한 조사를 XRD로 분석 측정한다. 그리고 Hall effect를 통해 전자빔의 조사 전후의 캐리어 농도, 이동도 및 비저항 등에 대한 조사가 이루어진다. 동시에 Al을 촉매로 한 layer교환에 대하여 마찬가지로 분석을 통하여 최종적으로 비교분석이 이루어 진다. 전자빔을 조사한 샘플에 대하여 빠른 시간 및 캐리어농도 제어 등의 우수성이 보이며, 특히 ~98%이상의 결정화율을 보일 것으로 예상된다.

  • PDF

Development of Backup Calculation System for a Nuclear Steam Supply System Thermal-Hydraulic Model ARTS (Advanced Real-time Thermal Hydraulic Simulation) of the W/H Type NPP (W/H형 원전 시뮬레이터용 핵 증기공급 계통 열수력모델 ARTS(Advanced Real-time Thermal Hydraulic Simulation)의 보조계산체계 개발)

  • 서재승;전규동
    • Journal of Energy Engineering
    • /
    • v.13 no.1
    • /
    • pp.51-59
    • /
    • 2004
  • The NSSS (Nuclear Steam Supply System) thermal-hydraulic programs adopted in the domestic full-scope power plant simulators were provided in early 1980s by foreign vendors. Because of limited compulsational capability at that time, they usually used very simplified physical models for a real-time simulation of NSSS thermal-hydraulic transients, which entails inaccurate results and, thus, the possibility of so-called "negative training", especially for complicated two-phase flows in the reactor coolant system. In resolve the problem, KEPRI developed a realistic NSSS T/H program ARTS which was based on the RETRAN-3D code for the improvement of the Nuclear Power Plant full-scope simulator. The ARTS (based on the RETRAN-3D code) guarantees the real-time calculations of almost all transients and ensures the robustness of simulations. However, there is some possibility of failing to calculate in the case of large break loss of coolant accident (LBLOCA) and low-pressure low-flow transient. In this case, the backup calculation system cover automatically the ARTS. The backup calculation system was expected to provide substantially more accurate predictions in the analysis of the system transients involving LBLOCA. The results were reasonable in terms of accuracy, real-time simulation, robustness and education of operators, complying with FSAR and the AMSI/ANS-3.5-1998 simulator software performance criteria.