• Title/Summary/Keyword: 저온냉동

Search Result 210, Processing Time 0.025 seconds

An Experimental Study of Three Buffer Pulse Tube Refrigerator (Three buffer 맥동관 냉동기에 관한 실험적 연구)

  • 박성제;고득용;김효봉;신완순
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.189-193
    • /
    • 1999
  • An experimental study was carried out to improve the cooling capacity and performance of the pulse tube refrigerator. Three buffer pulse tube refrigerator was designed and fabricated, and the experimental apparatus was constructed. This paper presents operating process of three buffer pulse tube refrigerator and results obtained with the performance test. The cooldown characteristics and load characteristics are described. The lowest temperature measured in three pulse tube refrigerator was 88K and the cooling capacity at the optimum operating condition was 27W at 120K.

  • PDF

Study of Stirling Cryocooler Performance with different length of split tube (Split tube 길이변화에 따른 스터링 극저온 냉동기의 특성에 관한 연구)

  • 홍용주;박성제;고득용;김효봉;오군섭;김종학
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.37-40
    • /
    • 2001
  • A free piston and free displacer (FPFD) Stirling cryocooler for cooling infrared and cryo-sensor is currently under development at Korea Institute of Machinery & Materials. In this study, performance tests of stirling cryocooler with different length of split tube were performed to get characteristics of cryocooler. The Experimental results show the Stirling cryocooler with small volume of split tube has higher cooling power and faster response time.

  • PDF

An Experimental Study of a Therr Buffer Pulse Tube Refrigerator (Three Buffer 맥동관 냉동기에 관한 실험적 연구)

  • 박성재;고득용;김효봉;신완순
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.2
    • /
    • pp.54-59
    • /
    • 1999
  • An experimental study was carried out to improve the cooling capacity and performance of the pulse tube refrigerator. Three buffer pulse tube refrigerator was designed and fabricated, and the experimental apparatus operating process of the therr buffer pulse tube refrigerator and results obtained with the performance test. The cooldown characteristics and load characteristics are described. The lowest temperature measured in the three buffer pulse tube refrigerator was 88K and the cooling capacity at the optimum operating condition was 27 W at 120K.

  • PDF

Performance Test of the Stirling Cryocooler for Cooling of the Infrared Detectors (적외선 센서 냉각용 스터링 냉동기의 성능시험)

  • 고득용;박성제;김효봉;염한길;김홍국;김남환
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.202-206
    • /
    • 1999
  • This paper presents operating process of the Stirling cryocooler and results obtained with the performance test for Signal Usfa UP 7075 Stirling cryocooler. An experimental study was carried out to develop the more reliable Stirling cryocooler. The cooldown characteristics and load characteristics are described. The lowest temperature measured in the Stirling cryocooler wa 62.5K and the cooling capacity at the optimum operating condition was 0.4W at 77K. At that time, carnot COP was 0.024.

  • PDF

Design of the Linear Compressor Stirling Cryocooler (Linear compressor 스터링 냉동기 설계에 관한 연구)

  • 박성제;고득용;홍용주;김효봉
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.81-84
    • /
    • 2000
  • This paper presents operating process and design method on the linear compressor Stirling cryocooler for cooling infrared detector. The free piston-type Stirling cryocooler, which applies 1) the Stirling cycle for refrigeration, 2) linear motors for driving, 3) flexure bearings for support systems, and 4) fine gap for clearance seals, is the most suitable design for a mechanical cryocooler utilized in a night vision environment.

  • PDF

The Performance Investigation of 1/4 Wavelength Thermoacoustic Refrigerator with Helium Refrigerant (헬륨을 냉매로 사용한 1/4파장 열음향 냉동기의 성능 평가)

  • 송규조;박종호;이성노
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.52-57
    • /
    • 2002
  • In this study, a thermoacoustic refrigerator, using a resonant standing acoustic wave. has been built. The refrigerant is helium gas. The description of thermoacoustic refrigerator was Presented. The temperature ratio (cold part temperature over hot part temperature) and the COP (Coefficient of Performance) that normalized by carnot's COP are plotted versus the thermal load applied to the cold end, for- various speaker power.

Neon liquefaction system manufacture and characteristic that use GM refrigerator (GM 냉동기를 이용한 네온액화시스템 제작과 특성)

  • 권운식;손명환;백승규;이언용;권영길;서정세;문태선;조창호
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.278-280
    • /
    • 2003
  • We manufactured neon liquefaction system for cooling system of HTS motor. The neon liquefaction system consists of a GM refrigerator, a liquefaction vessel and a vacuum chamber. It is found that the neon starts to be liquefied in the liquefaction vessel after 35 minutes of cool-down from gas state of 294k. Capacity of neon liquefaction system and the liquefaction rate were about 36W, 0.1g/s.

  • PDF

Performance Analysis of an Ammonia(R717) and Carbon Dioxide(R744) Two-Stage Cascade Refrigeration System ($NH_3-CO_2$를 사용하는 이원 냉동 시스템의 성능 분석)

  • Son, Chang-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • In this paper, cycle performance analysis of $NH_3-CO_2$(R717-R744) two-stage cascade refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, compressor efficiency, and condensing and evaporating temperature in the ammonia(R717) high temperature cycle and the carbon dioxide low temperature cycle. The main results were summarized as follows : The COP of two-stage cascade refrigeration system increases with the increasing subcooling degree, but decreases with the increasing superheating degree. The COP of two-stage cascade refrigeration system decreases with the increasing condensing temperature, but increases with the increasing evaporating temperature. And the COP of two-stage cascade refrigeration system increases with increasing the compressor efficiency. Therefore, superheating and subcoolng degree, compressor efficiency, and evaporating and condensing temperature of $NH_3-CO_2$(R717-R744) two-stage cascade refrigeration system have an effect on the COP of this system.

Market and Trend of the Cryogenic Refrigerator (적외선 및 저온 센서 냉각 기술의 시장과 동향)

  • 이성래;손홍균;채민수;유병건
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.11
    • /
    • pp.31-36
    • /
    • 2002
  • 극저온 냉동기 시장은 군수시장이 대부분이며 민수시장은 현재까지는 여러 분야에 응용되기 시작하는 시장 형성기에 있다. 그러나 향후 초전도시장과 더불어 성장이 기대되는 시장이다. 국내는 기술 개발면에서 많은 발전을 하고 있지만 아직도 외국에 비하여 뒤떨어진 실정이며 특히 극저온 냉동기의 제조 공정과 경제성 면에서의 기술발전은 본사를 제외하고서는 전무한 실정이다. 생산기술의 면에서의 연구 부족은 제한된 시장과 많은 기술장벽과 단시간의 개발기간 등에 주원인이 있다고 하겠다. 이러한 공정기술 낙후성은 가격경쟁력에서 뚜렷이 나타날 수밖에 없으며 이를 극복하기 위해서는 지속적인 개발과 체계적 지원이 뒤따라야 한다. 극저온냉동기의 국산화를 위해서는 원천기술 개발뿐만 아니라 공정 및 생산기술 개발 또한 절실히 필요하다. 따라서 많은 관계 연구자들의 연구와 관심이 뒤따라야 한다.

맥동관형 크라이오펌프 개발품의 목표성능에 대한 고찰

  • In, Sang-Ryeol;Tak, Yeong-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.226-226
    • /
    • 2012
  • 국산 크라이오 펌프를 개발하는 사업이 1단계 3년을 지나 올해 2단계에 접어들었다. 그동안 기계연을 중심으로 맥동관형 냉동기 개발에 주력하면서 저온성능 향상에서 큰 진전을 보였고 2단계에서는 우성진공의 주도하에 펌프의 상용화를 목표로 하고 있다. 펌프는 냉동기 뿐만 아니라 활성탄 어레이와 열차폐 및 배플이 잘 설계되어야 최적의 배기성능을 나타낼 수 있다. 우선은 펌프의 목표성능을 좀 더 구체화할 필요가 있고, 각 부품들의 상세한 형상결정에 앞서 개략적인 배치설계에 대해 성능을 예측하여 목표성능과 비교하고 설계를 수정하는 것을 반복하여 전반적으로 구조설계의 최적화를 완성하는 것이 급선무이다. 본 발표에서는 이런 구조설계 최적화 작업의 처음 결과와 개발중인 크라이오 펌프의 최종 성능 목표치에 대해 소개한다.

  • PDF