• 제목/요약/키워드: 저선량

Search Result 487, Processing Time 0.026 seconds

Effects of low dose gamma radiation on the germination and yield components of chinese cabbage (저선량 ${\gamma}$선 조사가 배추종자의 발아와 수량에 미치는 효과)

  • Kim, Jae-Sung;Kim, Jin-Kyu;Lee, Young-Keun;Back, Myung-Wha;Gim, Jeong-Kyu
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.3
    • /
    • pp.274-278
    • /
    • 1998
  • To observe the stimulating effects of low-dose ${\gamma}-radiation$ on the Chinese cabbage, $1{\sim}5$ years old seeds were cultivated in the green house and the experimental field after irradiation of $0.5Gy{\sim}30.0Gy$ and the growth characters of them were investigated. The germination rates and the seedling heights of old seeds increased positively in the green house, but different from each other depending on their period of storage. Those of 3-, 4-, and 5-year old seeds increased remarkably at the 4.0Gy-, 1.0Gy-, and 0.5Gy-irradiation group respectively. However, in the case of 1-year and 2-year old seeds, there were not significant effects of irradiation except the increase of seedling height. There were significant increasing effects of radiation on the plant height, fresh weight, and diameter of all seeds grown in the experimental field of 4.0Gy- and 8.0Gy-irradiation group, including the corresponding effects of 1-year and 2-year old seeds in 20.0Gy- and 30.0Gy-irradiation group.

  • PDF

Effectiveness of the Detection of Pulmonary Emphysema using VGGNet with Low-dose Chest Computed Tomography Images (저선량 흉부 CT를 이용한 VGGNet 폐기종 검출 유용성 평가)

  • Kim, Doo-Bin;Park, Young-Joon;Hong, Joo-Wan
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.411-417
    • /
    • 2022
  • This study aimed to learn and evaluate the effectiveness of VGGNet in the detection of pulmonary emphysema using low-dose chest computed tomography images. In total, 8000 images with normal findings and 3189 images showing pulmonary emphysema were used. Furthermore, 60%, 24%, and 16% of the normal and emphysema data were randomly assigned to training, validation, and test datasets, respectively, in model learning. VGG16 and VGG19 were used for learning, and the accuracy, loss, confusion matrix, precision, recall, specificity, and F1-score were evaluated. The accuracy and loss for pulmonary emphysema detection of the low-dose chest CT test dataset were 92.35% and 0.21% for VGG16 and 95.88% and 0.09% for VGG19, respectively. The precision, recall, and specificity were 91.60%, 98.36%, and 77.08% for VGG16 and 96.55%, 97.39%, and 92.72% for VGG19, respectively. The F1-scores were 94.86% and 96.97% for VGG16 and VGG19, respectively. Through the above evaluation index, VGG19 is judged to be more useful in detecting pulmonary emphysema. The findings of this study would be useful as basic data for the research on pulmonary emphysema detection models using VGGNet and artificial neural networks.

Sensitivity Analysis of Critical Findings Other than Lung Cancer in Low-Dose CT Using "S" Modifier ("S" modifier를 이용한 저선량 CT의 폐암 외 중요 소견에 대한 민감도 분석)

  • Hyeon-Jin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.343-350
    • /
    • 2023
  • Based on Lung CT Screening Reporting and Data System (Lung-RADS), which has been used to standardize reading for lung cancer screening since November 2016, the types and frequency of "S" modifier findings other than lung cancer were analyzed. As a result of this study, 360 cases (35.19%) of "S" modifier were found in 1,023 subjects, and the most frequent diseases were coronary calcification and emphysema, 145 (14.17%) of coronary calcification and 138 (13.49%) of emphysema, indicating that the discovery rate was very high compared to other findings. In addition, it was found to be highly associated with the duration of smoking, and in the case of coronary calcification, 9 cases (5.73%) were found in the non-smokers group A, 23 cases (11.44%) within 10 years of smoking, 39 cases (13.68%) in the C group within 20 years of smoking, and 31% of the E group over 30 years of smoking. In addition to coronary calcification and emphysema, abnormal findings of pneumonia, lung epilepsy, and mediastinal disease were also found to be p<0.05 as a result of the analysis of the association with the smoking period, indicating that the smoking period was affected.

Effects of Low-Dose Gamma Irradiation on Physicochemical Properties and Formation of Resistant Starch of Corn Starch (저선량 감마선 조사가 옥수수 녹말의 이화학 성질 및 저항전분 생성에 미치는 영향)

  • Kim, Sung-Kon;Kim, Jeong-Hee;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.3
    • /
    • pp.378-384
    • /
    • 2006
  • Intrinsic viscosity of starch irradiated with Co-60 (0.25-9.1 kGy) significantly decreased, and swelling power and solubility measured at $80^{\circ}C$ linearly increased with increasing irradiated dose. Radiation treatment up to 1 kGy increased amylose content of starch. Water-binding capacity increased rapidly up to 3 kGy. Peak viscosity of irradiated starches by Rapid visco Analyser and Visco/amylo/Graph indicated that the decrease in peak viscosity was dose-dependent. Gamma irradiation showed no effect on endothermic temperatures of irradiated starches, but decreased endothermic enthalpy with increasing dose level. Viscosity of starch autoclaved at $120^{\circ}C$ and air-dried significantly decreased with increasing irradiation dose. Resistant starch content slightly decreased upon irradiation.

원전 1차계통 방사선량 감소를 위한 코발트 합금 대체기술 개발

  • 한정호;이덕현;노계호
    • Nuclear Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.324-336
    • /
    • 1994
  • 경수로형 원전에서 발생되는 작업종사자에 대한 피폭선량의 약90%는 1차계통내 재질성분으로부터 방사화되는 코발트 핵종에 기인한다. 원전 선진국에서는 이러한 코발트 생성원을 근원적으로 제거하여 1차계통내 방사선량을 획기적으로 감소시킬 목적으로 Co reduction program을 중점적으로 추진하여 왔으며, 이중 계통내 코발트 주생성원인 각종 밸브재질을 저 Co 또는 Co-free 합금으로 대체시키는 기술이 이미 상당한 수준에 이르렀다. 국내의 건설예정 원전에 있어서도 이러한 기술개발의 적용에 대한 검토가 요구되고 있는 점을 미루어 볼 때, 머지 않은 장래에 국내 원전에 대한 이 기술의 적용이 불가피할 것으로 보여진다. 본 기고문에서는 원전 1차계통내 밸브의 코발트 합금재질 대체기술과 관련된 내용을 중점적으로 소개, 검토하고자 한다.

  • PDF

Dose Distribution of 3-Channel Ovoid Applicator (3-Channel Vaginal Ovoids의 선량분포 특성)

  • Kim Chang Hee;Yun Sang Mo;Kim Sung Kyu;Shin Sei One
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.134-139
    • /
    • 2004
  • This study was aimed to develop a new ovoid applicator for vaginal high-dose rate intracavitary radiation therapy, evaluate uniformity of dose distribution, and assess clinical applicability. The authors evaluated dose uniformity of vaginal mucosa according to 5-different ovoid-separation using 2-channel and modified 3-channel ovoid applicator. There were no significant differences in the dose distribution along the vaginal mucosa with 2 and 2.5 cm separations, but there were between the 2-channel and 3-channel ovoid applicator with a separation of 3 cm or more. Although a low dose area was shown between two ovoid applicators with the 2-channel ovoid applicator, the dose distribution along the vaginal mucosa with the 3-channel ovoid applicator was very uniform.

  • PDF

Effects of Low Dose Ionizing Radiation on the Growth and Yield of Soybean Cultivars (저선량의 이온화방사선이 대두품종의 생육과 수량에 미치는 효과)

  • Kim, Jae-Sung;Lee, Young-Keun;Song, Hi-Sup;Park, Hong-Sook;Kim, Jeong-Gyu
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.1
    • /
    • pp.66-69
    • /
    • 1999
  • To investigate the hormetic effect of the low dose ${\gamma}-ray$, soybean(Glycine max L.) seeds of three cultivars (Hwangkeumkong, Bansakong, S900 cv.) were irradiated with the dose of 0.5∼20.0 Gy and cultivated in the experimental field. The hormetic effects of the low dose ${\gamma}-ray$ on the growth of field experiment were different from each cultivar, that is, more effective in the S900 cultivar of black seedcoat color than in the Hwangkeumkong and Bangsakong of yellow ones. The germination rate of S900 cultivar increased about 30% in the 0.5Gy irradiated group compared with that of the control. The plant height of the 4.0Gy irradiated group in both Bangsakong and S900 cultivar increased 15% more than that of the control. Grain yield and the number of pod in 1.0 Gy and 4.0 Gy irradiated group of S900 cultivar and that of 2.0 Gy irradiated group of Hwangkeumkong increased 25 and 35% on the average, respectively.

  • PDF

Effects of Low Dose γ-Radiation on Photosynthesis of Red Pepper (Capsicum annuum L.) and the Reduction of Photoinhibition (저선량 γ선 조사가 고추의 광합성과 광 스트레스 경감에 미치는 효과)

  • Lee, Hae-Youn;Baek, Myung-Hwa;Park, Soon-Chul;Park, Youn-Il;Kim, Jae-Sung
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.2
    • /
    • pp.83-89
    • /
    • 2002
  • The effect of low dose $\gamma$ radiation on photosynthesis and the reduction of photoinhibition in red pepper plant was investigated. The seedling height leaf width and leaf length of pepper were stimulated in plants grown from seeds irradiated with the low dose of 4 Gy. The $O_2$ evolution in the 4 Gy irradiation group was 1.5 times greater than in the control. To investigate the effect of low dose $\gamma$ radiation on response to high light stress, photoinhibition was induced in leaves of pepper by illumination of high light (900 $\mu mol/m^2/s$). Pmax was decreased with increasing illumination time by 20% in the control, while hardly decreased in the 4 Gy irradiation group. The photochemical yield of PSII, estimated as Fv/Fm, was decreased with increasing illumination time by 50% after 4 hours while Fo did not change. However, Fv/Fm in the 4 Gy irradiation group was decreased by 37% of inhibition, indicating that the photoinhibition was decreased by the low dose $\gamma$ radiation. Changes in the effective quantum yield of PSII, $\Phi_{PSII}$, and 1/Fo-1/Fm, a measure of the rate constant of excitation trapping by the PSII reaction center, showed similar pattern to Fv/Fm. And NPQ was decreased after photoinhibitory treatment showing no difference between the control and the 4 Gy irradiation group. These results showed the positive effect of low dose $\gamma$ radiation on the seedling growth and the reduction of photoinhibition.

The Effects of Gamma Irradiation on the Microbiological, Physicochemical and Sensory Quality of Peach (Prunus persica L. Batsch cv Dangeumdo) (감마선 조사에 의한 복숭아의 미생물학적, 이화학적 품질 및 관능적 품질 변화)

  • Kim, Mi-Seon;Kim, Kyoung-Hee;Yook, Hong-Sun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.3
    • /
    • pp.364-371
    • /
    • 2009
  • The effect of gamma irradiation ($0.5{\sim}2$ kGy) on the microbiological, physicochemical and sensory properties of peaches was investigated during 6 day storage at $20{\pm}3^{\circ}C$. Total aerobic bacteria, yeasts and molds significantly decreased with increasing dose level. In Hunter's color values, L-values decreased and a- and b-values increased with increment of irradiation dose level. Hardness significantly decreased with increment of irradiation dose level whereas pH, soluble solid, and total polyphenol contents increased with increment of irradiation dose level. DPPH (1,1-diphenyl-2-picrylhydrazyl) radical-scavenging activity of irradiated peach was higher than that of control and its activity increased with increment of irradiation dose level. Vitamin C content was not affected by irradiation. In sensory test, overall acceptabilities of irradiated samples were higher than those of control. These results suggest that gamma irradiation on peach was effective for microbiological safety while improving the antioxidant activity, but not good on color and texture of peach.

A Study On Low Radiation Measurement of Radiation Measuring Devices and Improvement of Reaction Speed according to the Rapid Change of Radiation Dose (방사선 측정장치의 저준위 방사선 측정과 방사선량의 급격한 변화에 따른 장치의 반응 속도개선에 관한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.544-551
    • /
    • 2014
  • This paper suggests an algorithm to measure low-level radiation by radiation measuring devices, and the other algorithm to improve reaction speed of the device to better respond to dramatic changes in radiation amount. The former algorithm to improve the accuracy of measuring low-level radiation takes advantage of a dual window radiation measurement method which is based on accumulated average of pulses gathered by a radiation measuring sensor. The latter algorithm is to enhance reaction speed of a measuring device to more sensitively react to dramatic changes in radiation amount by adopting a dual window radiation measurement method which analyzes data patterns newly put into for six seconds. To verify the suggested algorithms, a hardware-which consists of sensor and high-voltage generator, controller, charger and power supply circuit, wireless communication part, and display part-was used. Tests conducted on the dual window radiation measurement method as used in the suggested algorithm have proved that accuracy improves to measure low-level radiation of 5uSv/h, and linearity also gets better. Other tests were conducted to see whether the suggested algorithm enhances the reaction speed of a radiation measuring device so that the device responds better to dramatically changing radiation amount. The experimental results have shown meaningful changes in numbers after six seconds. Therefore, the conclusions are made that the algorithm enhances the reaction speed of the device.