• Title/Summary/Keyword: 저류상수(K)

Search Result 50, Processing Time 0.026 seconds

A Study of Flood Runoff Variation by Travel Times Estimation Methods (도달시간 산정방법에 따른 홍수유출특성 변화에 관한 연구)

  • Park, Ki-Bum;Ko, Jin-Seuk;Jee, Hong-Gee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.1
    • /
    • pp.34-45
    • /
    • 2006
  • In this study comparison estimates travel times with observed travel time. In generally, peak flood discharges decrease become travel times longer. It is closely related to storage constant for the watershed routing of a flood. There are so many empirical formulas available for the estimation of travel time, storage coefficients and lag time but results computed generally show great different depending on individual formulas. When calculated flood discharge depend on the travel times varying the discharge. In this study the Wichun travel time shorter optimization travel time than observed travel time for the rusa and memi. There are showed good results for flood discharges, water level and velocity of the memi at the Younggok.

  • PDF

A Sensitivity Analysis of Model Parameters involved in Clark Method on the Magnitude of Design Flood for urban Watersheds (CLARK 유역추적법에 의한 계획홍수량 산정에 미치는 매개변수의 민감도 분석)

  • Yoon, Kwang-Wonn;Wone, Seog-Yeon;Yoon, Yong-Nam
    • Water for future
    • /
    • v.27 no.4
    • /
    • pp.85-94
    • /
    • 1994
  • A Sensitivity analysis on the model parameters involved in the Clark watershed routing method is made to demonstrate the effect of each parameter on the magnitude of 50-year design flood for small urban streams. As for the rainfall parameter the time distribution pattern of design storm was selected. For short duration storms Huff, Yen & Chow and Japanese Central type distributions were selected and the Mononobe distribution of 24-hour design storm was also selected and tested for Clark method application. The effect of SCS runoff curve number for effective rainfall and the methods of subbasin division for time-area curve were also tested. The routing parameter, i.e. the storage constant(K), was found to be the dominating parameter once design storm is selected. A multiple regression formula for K correlated with the drainage area and main channel slope of the basin is proposed for the use in urban stream practice for the determination of design flood by Clark method.

  • PDF

A Simulation Study on the Analysis of Optimal Gas Storage System of the Depleted Gas Reservoir (고갈가스전에의 적정 가스저장시스템 분석을 위한 시뮬레이션 연구)

  • Lee, Youngsoo;Choi, Haewon;Lee, Jeonghwan;Han, Jeongmin;Ryou, Sangsoo;Roh, Jeongyong;Sung, Wonmo
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.515-522
    • /
    • 2007
  • In this study we have attempted to evaluate the technical feasibility of "BB-HY", which is depleted gas reservoir as a gas storage field, using the commercial compositional simulator "ECLIPSE 300". The "BB-HY" reservoir has an initial gas in place of 143 BCF which is relatively small, and its porosity and permeability are 19.5% and 50 md, respectively. For "BB-HY" gas reservoir, we have performed a feasibility analysis by investigating the cushion gas (or working gas), converting time to gas storage field, operation cycle, number of wells and the possible application of horizontal borehole as well. From the simulation results, it was found that the amount of cushion gas in "BB-HY" reservoir is required at least 50% of IGIP in order to operate stably as gas storage field. When one produces gas for longer time and hence the remaining gas in reservoir is less than optimal cushion gas, no technical problem was occurred as long as additional cushion gas is injected up to the optimal cushion gas. In the case of changing the operation cycle into producing gas for three months during winter season from producing five months, the result shows that either the cushion gas should be greater than 60% or the more number of wells should be drilled. Meanwhile, from the results of sensitivity analysis for the number of wells, in cases of operating six or eight vertical wells, the stable reproduction of the injected gas can not be possible in "BB-HY" gas reservoir since the remaining gas in reservoir is increased. Therefore, in "BB-HY" reservoir, at least ten vertical wells should be drilled for the stable operation of gas. This time, when three horizontal wells are additionally drilled including the existing two vertical wells, it was found that the operation of injection and reproduction of gas is relatively stable in "BB-HY" gas reservoir.

Water supply reliability analysis of Sand dam (샌드댐의 물공급 신뢰도 분석)

  • Chung, Il-Moon;Lee, Jeongwoo;Kim, Min-Gyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.27-27
    • /
    • 2020
  • 샌드댐은 주로 건조지역에서 홍수시 유량을 차단시켜 유송토사와 함께 유입된 물을 장기간 보관함으로써 모래와 물이 함께 저장되며 모래속에 저장된 물을 취수하는 방식의 특수한 저류 구조물이다. 우리나라에서는 아직 적용된 바 없으나 상수도 미급수 지역인 계곡부에서 물을 모래안에 저장하게 되면 증발로부터 오래 견딜 수 있는 장점을 활용할 수 있을 것이다. 본 연구에서는 이와 같은 계곡부 샌드댐의 실제 가뭄시 물공급 신뢰도를 평가하기 위한 분석을 수행하였다. 분석 대상지역은 춘천 서상리로 물공급 능력을 평가하기 위해 유역수문모형 SWAT-K와 저수지 유출추적을 결합한 모의모형을 개발하고 이를 적용하였다. 샌드댐의 제원을 다양하게 고려하여 최적 설계 인자를 도출하기 위해 폭, 높이, 길이 등 구조물의 제원을 다양하게 변경하며 물공급 신뢰도 95 %를 만족할 수 있는지 평가하였다. 일반적인 댐의 이수안전도 평가시에는 분석 단위기간을 5일, 10일로 하고 있으나, 본 연구에서는 유역면적이 작은 관계로 분석 단위기간을 1일로 설정하였다. 총 9년간의 분석을 수행하였고, 5 %에 해당하는 연간 약 18일의 물공급 부족이 발생하는 신뢰도를 기준으로 일 취수량 20-50 ㎥을 적용하였을 때의 물수지 분석을 수행하여 샌드댐과 기존 취수보의 규모에 따른 물공급 능력을 평가하였다.

  • PDF

An application of the A-PDA model and the water supply performance index for the temporal and spatial evaluation of the performance of emergency water supply plans via interconnections (비상시 용수 연계공급 성능의 시·공간적 평가를 위한 A-PDA 모형 및 공급성능지표의 적용)

  • Oak, SueYeun;Kim, SuRi;Jun, Hwandon
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.11
    • /
    • pp.977-987
    • /
    • 2018
  • The purpose of the water distribution system is gradually changing to increase the flexibility for responding to various abnormal situations. In addition, it is essential to improve resilience through preparing emergency plans against water supply failure. The most efficient way is emergency interconnections which supply water from interconnected adjacent blocks. To operate successful interconnections, it is essential to evaluate the supply performance in spatial and temporal aspects. The spatial and temporal aspects are dominated by its interconnected pipes and interconnected reservoirs respectively. In this study, an emergency interconnection scenario where problem occurred in reservoir 1 at 0:00hr in A city, Korea. An Advanced-Pressure Driven Analysis model was used to simulate the volume and inflow volume of the interconnected reservoirs. Based on the hydraulic analysis results, a multi-dimensional evaluation of the supply performance was conducted by applying possible water supply range indicator (PWSRI) and possible water supply temporal indicator (PWSTI) which are based on fuzzy membership functions. As a result, it was possible to evaluate the supply performance on the sides of consumers in spatio-temporal aspects and to review whether established plans mitigate the damage as intended. It is expected to be used for decision making on structural and non-structural emergency plan to improve the performance of an emergency interconnection.

Analysis of First Flush of Recreation Park and Removal Rate According to Rainfall-Runoff Storage Depth (위락시설지역의 초기세척현상과 초기 강우-유출고 저류에 따른 저감효율 분석)

  • Jung, Jae-Woon;Park, Ha-Na;Choi, Dong-Ho;Baek, Sang-Soo;Yoon, Kwang-Sik;Baek, Won-Jin;Beam, Jin-A;Lim, Byung-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.648-655
    • /
    • 2013
  • Nonpoint source pollution characteristics of recreation park was investigated. Runoff ratio of recreation park ranged 23-57%, which was lower than other urban area since impervious area was less than 37%. The average BOD, COD, TOC, SS, T-N, T-P, were 14.09, 32.86, 12.19, 121.51, 7.78 and 0.72 mg/L, respectively. First flush of recreation park was analyzed by normalized cumulative load - volume curve and mass first flush ratio(MFFn), MFF10 for BOD, COD, SS, T-P, T-N, TOC were 2.90, 1.59, 2.15, 2.74, 2.60, and 1.59, respectively. Observed data showed that 62% of pollutant could be removed by storaging 5 mm rainfall-runoff and even 3 mm depth could store up to 50% of pollutant in runoff.

Suggestion of the Modified Archie's Formula for Calculating Water Saturation of Clean Sandstone and Carbonate Rocks (청결 사암 및 탄산염암의 물 포화도 산출을 위한 수정 Archie 경험식의 제안)

  • Lee, Sang-Hee;Ko, Eun-Ji;Kim, Jin-Hoo
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.3
    • /
    • pp.125-132
    • /
    • 2015
  • The water saturation ($S_w$), which is very important to estimate hydrocarbon reserves in the reservoir, has been determined from resistivity index (RI) by using the Archie's formula. However, in many cases, it has been reported that n is not constant for a given formation and it could be varied with water saturation. In addition, it frequently happens that the line obtained by linear regression analysis on log-log scale does not pass through the origin. In order to overcome these drawbacks, we suggested a modified Archie's formula, which can handle almost all the RI vs. $S_w$ cross-plots whether the trend is straight or curved and whether it passes through the origin or not. We also demonstrated that how to determine conductivity exponent ${\mu}$, critical water saturation $S_c$, and saturation distribution factor b in the laboratory to use the modified Archie's formula. Since the modified Archie's formula takes into account pore structure, pore water distribution, and wettability of reservoir such as clean sandstone and carbonate rocks, it might improve field applicability.

Analysis of Stream Depletion due to Groundwater Pumping in Variable Stream Stages Using an Analytical Model (해석적 모형을 이용한 지하수 양수 및 하천수위 변화에 따른 하천수 감소 특성 분석)

  • Lee, Jeongwoo
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.439-449
    • /
    • 2019
  • To prevent the drying-out of streams and to make effective use of stream water and groundwater, it is necessary to evaluate the impact of groundwater pumping on nearby streams. To this end, stream depletion due to groundwater pumping should be investigated in terms of various hydraulic characteristics of the aquifer and stream. This study used the Baalousha analytical solution, which accounts for stream-stage variation over time, to analyze stream depletion due to groundwater pumping for cases where the stream level decreases exponentially and recovers after the decrease. For conditions such as an aquifer transmissivity of 10~100 ㎡ d-1, storage coefficient 0.05~0.3, streambed hydraulic conductance 0.1~1.0 m d-1, stream-well distance 100~500 m, and stage recession coefficient 0.1~1.0 d-1, the contribution of stream water (the dimensionless ratio of stream water reduction rate to groundwater pumping rate) was analyzed in cases where stream level change was considered. Considering the effect of stream-stage recession, the contribution of stream water is greatly reduced and is less affected by the stream-depletion factor, which is a function of the stream-to-well distance and hydraulic diffusivity. However, there is no significant difference in stream depletion under constant- and variable-stage recovery after recession. These results indicate that stream level control can distribute the relative impacts on stream water and aquifer storage during groundwater pumping

Development of Runoff Hydrograph Model for the Derivation of Optimal Design Flood of Agricultural Hydraulic Structures(1) (농업수리구조물의 적정설계홍수량 유도를 위한 유출수문곡선모형의 개발(I))

  • 이순혁;박명근;맹승진
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.37 no.3_4
    • /
    • pp.34-47
    • /
    • 1995
  • It is experienced fact as a regular annual event that the structure to he designed on unreasonable flood for the agricultural structures including reservoirs have been brought not only loss of lives, but also enormous property damage. For the solution of this problem at issue, this study was conducted to develop an optimal runoff hydrograph model by comparison of the peak flows and time to peak between observed and simulated flows derived by linear time-invariant and linear time-variant models under the condition of having a short duration of heavy rainfall with uniform rainfall intensity at nine small watersheds which are within the range of 55.9 to 140.7 square kilometers in area in Han, Geum, Nagdong and Yeongsan Rivers. The results obtained through this study can be summarized as follows. 1. Storage constants and Gamma function arguments were calculated within the range of 1.2 to 6.42 and of 1.28 to 8.05 respectively by the moment method as the parameters for the analysis of runoff hydrograph based on linear time-invariant model. 2. Parameters for both linear time-invariant and linear time-variant models were calibrated with nine gaged watershed data, using a trial and error method. The resulting parameters including Gamma function argument, N and storage constant, K for linear time-invariant model were related statistically to watershed characteristic variables such as area, slope, length of main stream and the centroid length of the basin. 3. Average relative errors of the simulated peak discharge of calibrated runoff hydrographs by using linear time-variant and linear time-invariant models were shown to be 0.75 and 5.42 percent respectively to the peak of observed runoff hydrographs. Correlation coefficients for the statistical analysis in the same condition were shown to be 0.999 and 0.978 with a high significance respectively. Therefore, it can be concluded that the accuracy of a linear time-variant model is approaching more closely to the observed runoff hydrograph than that of a linear time-invariant model in the applied watersheds. 4. Average relative errors of the time to peak of calibrated runoff hydrographs by using linear time-variant and linear time-invariant models were shown to be 16.44 and 19.89 percent respectively to the time to peak of observed runoff hydrographs. Correlation coefficients in the same condition were also shown to be 0.999 and 0.886 with a high significance respectively. 5. It can be seen that the shape of simulated hydrograph based on a linear time- variant model is getting closer to the observed runoff hydrograph than that of a linear time-invariant model in the applied watersheds. 6. Two different models were verified with different rainfall-runoff events from data for the calibration by relative error and correlation analysis. Consequently, it can be generally concluded that verification results for the peak discharge and time to peak of simulated runoff hydrographs were in good agreement with those of calibrated runoff hydrographs.

  • PDF

Annual Groundwater System Change in Geum-gang Basin (금강 수계 지하수 시스템의 연간 물수지 변화 추정)

  • Kim, Ji-Eun;Kim, Tae-Hee
    • Economic and Environmental Geology
    • /
    • v.44 no.1
    • /
    • pp.49-57
    • /
    • 2011
  • Water budget analysis in the groundwater system was conducted in order to understand water budget distributions in the ground water system in Geum-gang watershed. The annual amounts of precipitation, runoff, evapotranspiration, dam storage change and water supply over the sub-watershed in Geum-gang watershed were evaluated the residual groundwater from 2002 to 2006, based on the water budget considering inflow and outflow. Then we are able to expect residual groundwater of each sub-basin. According to the result of study, the year 2003 and 2006 were recorded the highest and the lowest precipitation value, respectively. Average run-off percentage against precipitation was 60.44%. Annual evapotranspiration in each of years didn't show the remarkable variations but the values were high in the lower reaches of the basin. The residual waters in Geum-gang basin were determined to be 133.36 in 2002, 77.64 in 2003, -19.40 in 2004, -82.25 in 2005 and -128.07 mm in 2006. The residual water in Geum-gang basin was high in the main and up stream such as Maepo. Also the residual water showed low distributions in Nonsan and Seokhwa.