• Title/Summary/Keyword: 재사용 가능

Search Result 2,782, Processing Time 0.029 seconds

Clinical Application of Dose Reconstruction Based on Full-Scope Monte Carlo Calculations: Composite Dose Reconstruction on a Deformed Phantom (몬테칼로 계산을 통한 흡수선량 재구성의 임상적 응용: 변형된 팬텀에서의 총제적 선량재구성)

  • Yeo, Inhwan;Xu, Qianyi;Chen, Yan;Jung, Jae Won;Kim, Jong Oh
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.139-142
    • /
    • 2014
  • The purpose of this study was to develop a system of clinical application of reconstructed dose that includes dose reconstruction, reconstructed dose registration between fractions of treatment, and dose-volume-histogram generation and to demonstrate the system on a deformable prostate phantom. To achieve this purpose, a deformable prostate phantom was embedded into a 20 cm-deep and 40 cm-wide water phantom. The phantom was CT scanned and the anatomical models of prostate, seminal vesicles, and rectum were contoured. A coplanar 4-field intensity modulated radiation therapy (IMRT) plan was used for this study. Organ deformation was simulated by inserting a "transrectal" balloon containing 20 ml of water. A new CT scan was obtained and the deformed structures were contoured. Dose responses in phantoms and electronic portal imaging device (EPID) were calculated by using the XVMC Monte Carlo code. The IMRT plan was delivered to the two phantoms and integrated EPID images were respectively acquired. Dose reconstruction was performed on these images using the calculated responses. The deformed phantom was registered to the original phantom using an in-house developed software based on the Demons algorithm. The transfer matrix for each voxel was obtained and used to correlate the two sets of the reconstructed dose to generate a cumulative reconstructed dose on the original phantom. Forwardly calculated planning dose in the original phantom was compared to the cumulative reconstructed dose from EPID in the original phantom. The prescribed 200 cGy isodose lines showed little difference with respect to the "prostate" and "seminal vesicles", but appreciable difference (3%) was observed at the dose level greater than 210 cGy. In the rectum, the reconstructed dose showed lower volume coverage by a few percent than the plan dose in the dose range of 150 to 200 cGy. Through this study, the system of clinical application of reconstructed dose was successfully developed and demonstrated. The organ deformation simulated in this study resulted in small but observable dose changes in the target and critical structure.

Development of a Kit for Diagnosing AtCYP78A7 Protein in Abiotic-tolerant Transgenic Rice Overexpressing AtCYP78A7 (AtCYP78A7 과발현 환경스트레스 내성 형질전환 벼의 단백질 진단 키트 개발)

  • Nam, Kyong-Hee;Park, Jung-Ho;Pack, In-Soon;Kim, Ho Bang;Kim, Chang-Gi
    • Journal of Life Science
    • /
    • v.28 no.7
    • /
    • pp.835-840
    • /
    • 2018
  • Quantitative determination of the protein expression levels is one of the most important parts in assessment of the safety of foods derived from genetically modified (GM) crops. Overexpression of AtCYP78A7, a gene encoding cytochrome P450 protein, has been reported to improve tolerance to abiotic stress, such as drought and salt stress, in transgenic rice (Oryza sativa L.). In the present study, an enzyme-linked immunosorbent assay (ELISA) kit for diagnosing AtCYP78A7 protein including AtCYP78A7-specific monoclonal antibody was developed. GST-AtCYP78A7 recombinant protein was induced and purified by affinity column. Four monoclonal antibodies (mAb 6A7, mAb 4C2, mAb 11H6, and mAb 7E8) against recombinant protein were also produced and biotinylated with avidin-HRP. After pairing test using GST-AtCYP78A7 protein and lysate of rice samples, mAb 4C2 and mAb 7E8 were selected as a capture antibody and a detecting antibody, respectively, for ELISA kit. Product test using rice samples indicated that percentages of detected protein in total protein were greater than 0.1% in AtCYP78A7-overexpressing transgenic rice (Line 10B-5 and 18A-4), whereas those in negative control non-transgenic rice (Ilpum and Hwayoung) were less than 0.1%. The ELISA kit developed in this study can be useful for the rapid detection and safety assessment of transgenic rice overexpressing AtCYP78A7.

The Comparative Analysis of Exposure Conditions between F/S and C/R System for an Ideal Image in Simple Abdomen (복부 단순촬영의 이상적 영상구현을 위한 F. S system과 C.R system의 촬영조건 비교분석)

  • Son, Sang-Hyuk;Song, Young-Geun;Kim, Je-Bong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.37-43
    • /
    • 2007
  • 1. Purpose : This study is to present effective exposure conditions to acquire the best image of simple abdomen in Film Screen (F.S) system and Computed Radiography (C.R) system. 2. Method : In the F.S system, while an exposure condition was fixed as 70kVp, images of a patients simple abdomen were taken under the different mAs exposure conditions. Among these images, the best one was chosen by radiologists and radiological technologists. In the C.R system, the best image of the same patient was acquired with the same method from the F.S system. Both characteristic curves from F.S system and C.R system were analyzed. 3. Results : In the F.S system, the best exposure condition of simple abdomen was 70kVp and 20mAs. In the CR system, with the fixed condition at 70kVp, the image densities of human organs, such as liver, kidney, spleen, psoas muscle, lumbar spine body and iliac crest, were almost same despite different environments (3.2mAs, 8mAs, 12mAs, 16mAs and 20mAs). However, when the exposure conditions were over or under (below) 12mAs, the images between the abdominal wall and the directly exposed part became blurred because the gap of density was decreased. In the C.R system, while the volume of mAs was decreased, an artifact of quantum mottle was increased. 4. Conclusion : This study shows that the exposure condition in the C.R system can be reduced 40% than in the F.S system. This paper concluded that when the exposure conditions are set in CR environment, after the analysis of equipment character, such as image processing system(EDR : Exposure Data Recognition processing), PACS and so on, the high quality of image with maximum information can be acquired with a minimum exposure dose.

  • PDF

A Simultaneously Analytical Method of Phthalate and Adipate Plasticizers in Food Packaging by Dual-Column GC-FID System (Dual-Column GC-FID System을 이용한 식품 포장재 중 Phthalate류 및 Adipate류 가소제의 동시 분석법)

  • Kang Gil-Jin;Kwak In-Shin;Eom Mi-Ok;Jeon Dea-Hoon;Kim Hyung-il;Sung Jun-Hyun;Choi Jung-Mi;Kim Eun-Kyung;Lee Young Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.4
    • /
    • pp.277-283
    • /
    • 2005
  • A plasticizer is a substance which is added to a material to improve its processability, flexibility and stratchability. Phthalates and adipates are the most frequently used plasticizers of poly(vinyl chloride) (PVC). However, they can migtate into food from PVC food packaging, and some of them are especially suspected as endocrine disruptors. In this study, Simultaneous analysis of 13 phthalates and 9 adipates were carried out by dual-column gas chromatography system equipped wi two FID detectors for rapid confirmation and quantification. The Proposed method was validated with > 0.993 of linearity in the ranges of 10-500 mg/l, < $3.5\%$ RSD of reproducability in 10 inter-days sample preparations, and > $98.1\%$ of recoveries for all the plasticizers. DEHA was detected in all the 3 PVC wraps at levels of 176.9-198.5mg/g. Among the 51 samples of PVC gaskets, the targeted plasticizers were detected in 41 samples. Of these plasticizer detected samples,40 contained DIDP at the levels of 157.3-374.7 mg/g and one contained DMP at the levels of 165.6 mg/g. Also, some plasticizers were detected in other packaging materials such as PET, PP, PE, Pulp. But it might be attributed to contamination in manufacturing.

The Estimation Model of an Origin-Destination Matrix from Traffic Counts Using a Conjugate Gradient Method (Conjugate Gradient 기법을 이용한 관측교통량 기반 기종점 OD행렬 추정 모형 개발)

  • Lee, Heon-Ju;Lee, Seung-Jae
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.1 s.72
    • /
    • pp.43-62
    • /
    • 2004
  • Conventionally the estimation method of the origin-destination Matrix has been developed by implementing the expansion of sampled data obtained from roadside interview and household travel survey. In the survey process, the bigger the sample size is, the higher the level of limitation, due to taking time for an error test for a cost and a time. Estimating the O-D matrix from observed traffic count data has been applied as methods of over-coming this limitation, and a gradient model is known as one of the most popular techniques. However, in case of the gradient model, although it may be capable of minimizing the error between the observed and estimated traffic volumes, a prior O-D matrix structure cannot maintained exactly. That is to say, unwanted changes may be occurred. For this reason, this study adopts a conjugate gradient algorithm to take into account two factors: estimation of the O-D matrix from the conjugate gradient algorithm while reflecting the prior O-D matrix structure maintained. This development of the O-D matrix estimation model is to minimize the error between observed and estimated traffic volumes. This study validates the model using the simple network, and then applies it to a large scale network. There are several findings through the tests. First, as the consequence of consistency, it is apparent that the upper level of this model plays a key role by the internal relationship with lower level. Secondly, as the respect of estimation precision, the estimation error is lied within the tolerance interval. Furthermore, the structure of the estimated O-D matrix has not changed too much, and even still has conserved some attributes.

A Study on Formulation of Surfactant-free Aqueous Cleaning agents and Evaluation of Their Physical Properties and Cleaning Ability (계면활성제 무첨가 세정제의 배합 및 물성/세정성 평가 연구)

  • Lee, Jae Ryoung;Yoon, Hee Keun;Lee, Min Jae;Bae, Jae Heum;Bae, Soo Jeong;Lee, Ho Yeoul;Kim, Jong Hee
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.219-225
    • /
    • 2013
  • Environment-friendly and surfactant-free aqueous cleaning agents have been developed in order to solve various problems generated by surfactants in the aqueous cleaning agents. Aqueous surfactant-free cleaning agents, S-1 and S-2 have been formulated with water-soluble solvents such as propylene glycol and propylene glycol ether on their main components and with some additives. These solvents were chosen because of their good solubility in water and excellent solubility of fluxes which are major contaminants of printed circuit board in the electronic industry. Physical properties of the formulated and the imported cleaning agents were measured to predict their cleaning performance, and their cleaning abilities of flux and solder contaminants were evaluated under the various ultrasonic frequencies by a gravimetric method. The measurement results show that the physical properties of cleaning agent V are generally similar with those of formulated cleaning agents S-1 and S-2. Both the cleaning agent V and the formulated cleaning agents S-1 and S-2 showed similar trends that their pH decrease in the beginning and then increases later on with the increase of their dilution in water. It is considered that the wetting indices of the cleaning agents calculated with experimental values do not not have any influence on their cleaning ability. In ultrasonic cleaning tests under three ultrasonic frequencies of 28, 45, and 100 kHz, their best performances of cleaning solder and flux were obtained at 45 kHz and 28 kHz, respectively, and the cleaning performance of the formulated cleaning agents S-1 and S-2 was better than that of the cleaning agent V. However, in the case of the recommended diluted concentration of 25 wt% cleaning solution, the cleaning performance of the cleaner V for solder and flux was better in the initial stage of cleaning compared to the formulated cleaners. And it may be concluded that the formulated cleaning agents S-1 and S-2 can be applied to cleaning of solder and flux in the industry, based on the experimental results in this study.

The Effects of Catheter Revision and Mupirocin on Exit Site Infection/Peritonitis in CAPD Patients (복막 투석 환자에서 도관 관련 감염 및 복막염에 대한 Mupirocin과 도관 전환술(Catheter revision)의 효과)

  • Park, Jun-Beom;Kim, Jung-Mee;Choi, Jun-Hyuk;Jo, Kyu-Hyang;Jung, Hang-Jae;Kim, Yeung-Jin;Do, Jun-Yeung;Yoon, Kyung-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.347-356
    • /
    • 1999
  • Background: Exit site/tunnel infection causes considerable morbidity and technique failure in CAPD patients. We presently use a unique revision method for the treatment of refractory ESI/TI in CAPD patients and mupirocin prophylaxis for high risk patients. Materials and Methods: We reviewed 139 CAPD patients about the ESI/TI from October 1993 to February 1999 at Yeungnam University Hospital. At the beginning of the ESI. we usually started medications with rifampicin and ciprofloxacin and then changed the antibiotics according to the sensitivity test. If the ESI had persisted and there were TI symptoms (purulent discharge, abscess lesion around exit site). we performed catheter revision(external cuff shaving, disinfection around tunnel and new exit site on opposit direction) with a combination of proper antibiotics. We applied local mupirocin ointment at the exit site three times per week to the 34 patients who had the risk of ESI starting from October 1998. Results: The total follow-up was 2401 patient months(pt. mon). ESI occurred on 105 occasions in 36 out of 139 patients, and peritonitis occurred on 112 occasions in 67 out of 139 patients. The total number of incidences of ESI and peritonitis was 1 per 23.0 pt. mon and 1 per 2l.6 pt.mon. The most common organism responsible for ESI was Staphylococcus aureus (26 of 54 isolated cases, 48%), followed by the Methicillin resistant S. aureus(MRSA) (13 cases, 24%). Seven patients(5: MRSA. 2: Pseudomonas) had to be treated with a revision to control infection. Three patients experienced ESI relapse after revision. One of them improved with antibiotics, while another needed a second revision and the remaining required catheter removal due to persistent MRSA infection with re-insertion at the same time. But, there was no more ESI in these 3 patients who were received management to relapse (The mean duration: 14.0 months). The rates of ESI were significantly reduced after using mupirocin than before(1 per 12.7 vs 34.0 pt.mon, P<0.01). Conclusions: In summary, revision technique can be regarded as an effective method for refractory ESI/TI before catheter removal. Also local mupirocin ointment can play a significant role in the prevention of ESI.

  • PDF

Investigation into influence of sound absorption block on interior noise of high speed train in tunnel (터널 내부 도상 블록형 흡음재의 고속철도차량 내부 소음에 미치는 영향에 대한 고찰)

  • Lee, Sang-heon;Cheong, Cheolung;Lee, Song-June;Kim, Jae-Hwan;Son, Dong-Gi;Sim, Gyu-Cheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.4
    • /
    • pp.223-231
    • /
    • 2018
  • Recently, due to various environmental problems, blast tracks in tunnel are replaced with concrete tracks, but they have more adverse effects on noise than blast tracks so that additional noise measures are needed. Among these measures, sound-absorbing blocks start to be used due to its easy and quick installation. However, the performance of sound absorption blocks need to be verified under real environmental and operational conditions. In this paper, interior noise levels in KTX train cruising in Dalseong tunnel are measured before and after the installation of sound-absorbing blocks and the measured data are analyzed and compared. Additionally, noise reduction are estimated by modeling the high speed train, the tunnel and absorption blocks. Measurement devices and methods are used according to ISO 3381 and the equivalent sound pressure levels during the cruising time inside the tunnel are computed. In addition to overall SPLs(Sound Pressure Levels), 1/3-octave-band levels are also analyzed to account for the frequency characteristics of sound absorption and equipment noise in a cabin. In addition, to consider the effects of train cruising speeds and environmental conditions on the measurements, the measured data are corrected by using those measured during the train-passing through the tunnels located before and behind the Dalseong tunnel. Analysis of measured results showed that the maximum noise reduction of 6.8 dB (A) can be achieved for the local region where the sound-absorbing blocks are installed. Finally, through the comparison of predicted 1/3-octave band SPLs for the KTX interior noise with the measurements, the understanding of noise reduction mechanism due to sound-absorbing blocks is enhanced.

Result of Radiation Therapy of Cerebellar Medulloblastoma - with Emphasis on the Neuraxis Dose - (전중추신경계 조사선량을 중심으로 한 수아세포종의 방사선치료성적)

  • Kim Joo Young;Kim Il Han;Ha Sung Whan;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.69-77
    • /
    • 1993
  • Treatment of cerebellar medulloblastoma has been much improved with modern surgical technique for gross total tumor removal and adequate radiation therapy for the whole craniospinal axis. Questions have been arosen about the optimal radiation dose for the preventive treatment of whole cranium and whole spinal axis. Recently, many authors have reported their treatment results as comparable to older data, using lower than conventional dose of 3,600 cGy-4,000 cGy. For 50 patients treated between 1981 and 1990 at the Department of Radiation Therapy of SNUH, retrospective analysis was done for the treatment result, especially the neuraxis control, by radiation dose for the presymptomatic area of the disease. Analysis only by total spinal dose did not give any significant difference. But further analysis by following patient group; 3,600 cGy/150 cGy (n=6), 3,000 cGy/150 cGy (n=10), 2,400 cGy/150 cGy (n=17) and 2,400 cGy/100-120 cGy (n=11) showed significant improvement of neuraxis control by decreasing order (p =0.003). There was no significant difference in overall survival between the groups. For the 19 patients who had been confirmed initially as having no neuraxis disease, TDF 30 was the cur-off value that could prevent neuraxis failure (p =0.004). We couldn't define any TDF value that give reasonable control for the patient group with positive CSF study at initial diagnosis.

  • PDF

Influence of Fine Aggregate Properties on Unhardened Geopolymer Concrete (잔골재 특성이 굳지 않은 지오폴리머 콘크리트에 미치는 영향)

  • Cho, Young-Hoon;An, Eung-Mo;Lee, Su-Jeong;Chon, Chul-Min;Kim, Dong-Jin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.2
    • /
    • pp.101-111
    • /
    • 2016
  • It is possible that aggregates add on to geopolymer based fly ash to mix mortar and concrete like cement. This is necessary to evaluate mineral composition, particle shape, surface, size distribution, density and absorption ratio for fine aggregates due to few detailed research to examine influence of fine aggregates properties on unhardened geopolymer concrete. In this research, used two different fine aggregates, Jumunjin sand(having quartz, mica, feldspar, pyroxene in mineral composition, more than 96% of total size between -0.60 and +0.30mm, angular shape and rough surface) and ISO sand(having almost all quartz in mineral composition, more than 51% size between -1.40 and +0.60mm, simultaneously varied size distribution, spherical shape and smooth surface). After an experimental result of the varied ratio of Si/Al=1.0-4.1 geopolymer paste, mix proportion respectively applied Si/Al=1.5 having the highest compressive strength to mortar and Si/Al=3.5 having the highest consistency to concrete. Geopolymer mortar by mixing with Jumunjin and ISO sand in varied range of 20-50wt.% showed flow size increase between 69.5 and 112.0mm, between 70.5 and 126.0mm respectively. Geopolymer concrete at an addition of 77wt.% of total aggregates ratio showed that average compressive strength was 32MPa and the consistency was favorable to molding. Since ISO sand observing varied size distribution, spherical shape, smooth surface, low absorption ratio resulted in advantageous properties on consistency of geopolymer, geopolymer concrete can be suitable for using the fine aggregates similar to ISO sand.