• Title/Summary/Keyword: 재사용 가능

Search Result 2,783, Processing Time 0.039 seconds

Study on the Thermal Storage Characteristics of Phase Change Materials for Greenhouse Heating (온실보온(溫室保溫)을 위한 상변화(相變化) 물질(物質)의 축열특성연구(蓄熱特性硏究))

  • Song, Hyun-Kap;Ryou, Young-Sun;Kim, Young-Bok
    • Solar Energy
    • /
    • v.13 no.2_3
    • /
    • pp.65-78
    • /
    • 1993
  • An overdose of fossil fuel for greenhouse heating causes not only the high cost and low quality of agricultural products, but also the environmental pollution of farm village. To solve these problems it is desirable to maximize the solar energy utilization for the heating of greenhouse in winter season. In this study phase change materials were selected to store solar energy concentratively for heating the greenhouse and their characteristics of thermal energy storage were analyzed. The results were summarized as follows. The organic $C_{28}H_{58}$, and the inorganic $CH_3COONa{\cdot}3H_2O\;and\;Na_2SO_4{\cdot}10H_2O$ were selected as low temperature latent heat storage materials. The equation of critical radius was derived to define the generating mechanism of the maximum latent heat of phase change materials. The melting point of $C_{28}H_{58}$ was $62^{\circ}C$, and the latent heat was $50.0{\sim}52.0kcal/kg$. The specific heat of liquid and solid phase was $0.54{\sim}0.69kcal/kg^{\circ}C$ and $0.57{\sim}0.75kcal/kg^{\circ}C$ respectively. The melting point of $CH_3COONa{\cdot}3H_2O$ was $61{\sim}62^{\circ}C$, the latent heat was $64.9{\sim}65.8$ kcal/kg and the specific heat of liquid and solid phase was respectively $0.83kcal/kg^{\circ}C$ and $0.51{\sim}0.52kcal/kg^{\circ}C$. The melting point of $Na_2SO_4{\cdot}10H_2O$ was $30{\sim}30.9^{\circ}C$, the latent heat was 53.0 kcal/kg and the specific heat of liquid and solid phase was respectively $0.78{\sim}0.89kcal/kg^{\circ}C$ and $0.50{\sim}0.7kcal/kg^{\circ}C$ When the urea of 21.85% was added to control the melting point of $Na_2SO_4{\cdot}10H_2O$ and the phase change cycles were repeated from 0 to 600, the melting point was $16.7{\sim}16.0^{\circ}C$ and the latent heat was $36.0{\sim}28.0kcal/kg^{\circ}C$.

  • PDF

Survival Rate on the Small Cyprinidae by PIT Tagging Application (소형 잉어과 어류의 PIT tag 적용을 위한 생존율 평가)

  • Jang, Min-Ho;Yoon, Ju-Duk;Do, Yuno;Joo, Gea-Jae
    • Korean Journal of Ichthyology
    • /
    • v.19 no.4
    • /
    • pp.371-377
    • /
    • 2007
  • The passive integrated transponder (PIT) telemetry is a useful method for investigating fish population dynamics, community structure and migration. It can be applied for small fishes (TL<100 mm) because of its tiny size and light weight. The survival rate of PIT tag was investigated on 4 small size cyprindae fish species, Carassius gibelio langsdorfi (n=34, standard length; $91.9{\pm}0.9mm$, body weight; $21.2{\pm}0.9g$), Hypophthalmichthys molitrix (n=16, SL; $75.1{\pm}0.9mm$, BW; $6.0{\pm}0.2g$), Pseudorasbora parva (n=30, SL; $51.4{\pm}1.1mm$, BW; $2.7{\pm}0.2g$) and Phoxinus phoxinus (n=37, SL; $70.6{\pm}1.4mm$, BW; $8.2{\pm}0.5g$) under age 1 for applicability and effectiveness. We used three type tags including a small (length 11.0 mm, diameter 2.1 mm, weight 0.088 g), middle (20 mm, 3.5 mm, 0.102 g), large (30 mm, 3.5 mm, 0.298 g) size. After 30 days of tag insertion, survival rate of 117 individuals were 58.1% (large tag, 50.0%; middle tag, 57.5%; small tag, 61.4%). Survival rates varied between three types of tags because the abdominal cavity of each individual was different size. The death was due to surgical damage. If we apply tagging systems on field research of the Korean freshwater fish, the PIT tag will be effective method for analyzing fish ecology.

Research Trends in Hybrid Cross-Laminated Timber (CLT) to Enhance the Rolling Shear Strength of CLT (CLT의 rolling shear 향상을 위한 hybrid cross laminated timber 연구 동향)

  • YANG, Seung Min;LEE, Hwa Hyung;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.49 no.4
    • /
    • pp.336-359
    • /
    • 2021
  • In this study, hybrid CLT research and development trends were analyzed to improve the low rolling shear strength of CLT, a large wooden panel used in high-rise wooden buildings. Through this, basic data that can be used in research and development directions for localization of CLT were prepared. As a way to improve the low rolling shear strength, the use of hardwood lamina, the change of the lamina arrangement angle, and the use of structural composite materials are mainly used. Rolling shear strength and shear modulus of hardwood lamina are more than twice as high as softwood lamina. It confirmed that hardwoods can be used and unused species can be used. Rolling shear strength 1.5 times, shear modulus 8.3 times, bending stiffness 4.1 times improved according to the change of the layer arrangement angle, and the CLT strength was confirmed by reducing the layer arrangement angle. Structural wood-based materials have been improved by up to 1.35 times MOR, 1.5 times MOE, and 1.59 times rolling shear strength when used as laminas. Block shear strength between the layer materials was also secured by 7.0 N/mm2, which is the standard for block shear strength. Through the results of previous studies, it was confirmed that the strength performance was improved when a structural wood based materials having a flexural performance of MOE 7.0 GPa and MOR 40.0 MPa or more was used. This was determined based on the strength of layered materials in structural wood-based materials. The optimal method for improving rolling shear strength is judged to be the most advantageous application of structural wood based materials with strength values according to existing specifications. However, additional research is needed on the orientation of CLT lamina arrangement according to the fiber arrangement of structural wood-based materials, and the block shear strength between lamina materials.

Uranium Adsorption Properties and Mechanisms of the WRK Bentonite at Different pH Condition as a Buffer Material in the Deep Geological Repository for the Spent Nuclear Fuel (사용후핵연료 심지층 처분장의 완충재 소재인 WRK 벤토나이트의 pH 차이에 따른 우라늄 흡착 특성과 기작)

  • Yuna Oh;Daehyun Shin;Danu Kim;Soyoung Jeon;Seon-ok Kim;Minhee Lee
    • Economic and Environmental Geology
    • /
    • v.56 no.5
    • /
    • pp.603-618
    • /
    • 2023
  • This study focused on evaluating the suitability of the WRK (waste repository Korea) bentonite as a buffer material in the SNF (spent nuclear fuel) repository. The U (uranium) adsorption/desorption characteristics and the adsorption mechanisms of the WRK bentonite were presented through various analyses, adsorption/desorption experiments, and kinetic adsorption modeling at various pH conditions. Mineralogical and structural analyses supported that the major mineral of the WRK bentonite is the Ca-montmorillonite having the great possibility for the U adsorption. From results of the U adsorption/desorption experiments (intial U concentration: 1 mg/L) for the WRK bentonite, despite the low ratio of the WRK bentonite/U (2 g/L), high U adsorption efficiency (>74%) and low U desorption rate (<14%) were acquired at pH 5, 6, 10, and 11 in solution, supporting that the WRK bentonite can be used as the buffer material preventing the U migration in the SNF repository. Relatively low U adsorption efficiency (<45%) for the WRK bentonite was acquired at pH 3 and 7 because the U exists as various species in solution depending on pH and thus its U adsorption mechanisms are different due to the U speciation. Based on experimental results and previous studies, the main U adsorption mechanisms of the WRK bentonite were understood in viewpoint of the chemical adsorption. At the acid conditions (<pH 3), the U is apt to adsorb as forms of UO22+, mainly due to the ionic bond with Si-O or Al-O(OH) present on the WRK bentonite rather than the ion exchange with Ca2+ among layers of the WRK bentonite, showing the relatively low U adsorption efficiency. At the alkaline conditions (>pH 7), the U could be adsorbed in the form of anionic U-hydroxy complexes (UO2(OH)3-, UO2(OH)42-, (UO2)3(OH)7-, etc.), mainly by bonding with oxygen (O-) from Si-O or Al-O(OH) on the WRK bentonite or by co-precipitation in the form of hydroxide, showing the high U adsorption. At pH 7, the relatively low U adsorption efficiency (42%) was acquired in this study and it was due to the existence of the U-carbonates in solution, having relatively high solubility than other U species. The U adsorption efficiency of the WRK bentonite can be increased by maintaining a neutral or highly alkaline condition because of the formation of U-hydroxyl complexes rather than the uranyl ion (UO22+) in solution,and by restraining the formation of U-carbonate complexes in solution.

Hybrid Off-pump Coronary Artery Bypass Combined with Percutaneous Coronary Intervention: Indications and Early Results (심폐바이패스 없이 시행하는 관상동맥우회술과 경피적 관상동맥중재술의 병합요법 : 적응증 및 조기성적)

  • Hwang Ho Young;Kim Jin Hyun;Cho Kwang Ree;Kim Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.38 no.11 s.256
    • /
    • pp.733-738
    • /
    • 2005
  • Background: The possibility of incomplete revascularization and development of flow competition after revascularization of the borderline lesion made the hybrid strategy as an option for complete revascularization. Material and Method: From January f998 to July 2004, 25 $(3.2\%)$ patients underwent hybrid revascularization among 782 total OPCAB procedures. Clinical results and angiographic patencies were evalulated. Percutaneous coronary intervention (PCI) was peformed before CABG in 8 patients and after CABG in 47 patients. Result: The causes of PCIs before CABG were to achieve complete revascularization with minimally invasive surgery (n=7) and emergent PCI for culprit lesion (n=1). The indications of PCIs after CABG were high possibility of flow competition in the borderline lesion of right coronary artery territory (n=8), diffuse atheromatous lesion preventing anastomosis of graft (n=5), severe calcified ascending aorta with no more arterial grafi available (n=3), and intramyocardial coronary lesion (n=1). Mean number of distal anastomoses was $2.3\pm1.0$. Mean number of lesions treated by PCI was $1.2\pm0.4$. There was no operative or procedure-related mortality. PCI-related complication was periprocedural myocardial infarction in one patient, and complications related to CABG were transient atrial fibrillation (n=5), perioperative myocardial infarction (n=1), and transient renal dysfunction (n=1). Early postoperative coronary angiography $(1.8{pm}1.6days)$ revealed $100\%$ patency rate of grafts (57/57). The stenosis occurred in one patient performed PCI before CABG, which was successfully treated with re-ballooning. During midterm follow-up (mean; $25{\pm}26$ months), 1 patient died of congestive heart failure. All survivors (n=24) accomplished follow-up coronary angiographics, which showed .all grafts (56/57) were patent except one string sign. In-stent restenosis was developed in 2 patients who received bare metal stents. Conclusion: In selected patients, complete revascularization was achieved with low risk by taking the hybrid strategy.

Reproducibility and accuracy of tooth size measurements obtained by the use of computer (컴퓨터를 이용한 치아크기 계측시 재현도와 정확도에 관한 연구)

  • Kim, Eun-Jeong;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.563-573
    • /
    • 1999
  • The purpose of this study was to evaluate the availability of computer system for the measurement of tooth size in the model analysis through the comparison of two measurements: One was to use a computer; and the other was to use vernier calipers. Twenty sets of casts were used, which showed a moderate degree of crowding and full eruption of all teeth. The mesio-distal width of 12 teeth from the left central incisor to the left first molar at each set of the casts were measured twice with vernier calipers and a computer respectively. This measurement was repeated two weeks later. First, for the reproducibility analysis, the two computer measurements were compared then the vernier calipers measurements were compared. Second, all the teeth were sepapated into the region of mesiodistal contact points and its width was measured by a micrometer to obtain standard measurements. For the accuracy analysis, these standard measurements were compared with the measurements from the dental casts using two methods. The difference between them was defined as the measurement error. To investigate the cause of measurement error, an examination was made for the presence and degree of contact point deviation on each tooth from the upper and lower occlusograms, and the mesio-distal angulation of each tooth was measured with TARG. Following results were obtained through statistical analysis. 1. In the analysis for reproducibility; the measurements with vernier calipers showed significant differences in three out of twelve teeth while the computer measurements showed significant differences in one out of twelve teeth. 2. In the analysis for accuracy; compared with the standard measurements, the measurements with vernier calipers showed significant differences in three out of twelve teeth while the computer measurements showed significant differences in two out of twelve teeth. 3. Compared with the standard measurements, the measurements with vernier calipers were apt to be larger at the upper first molar, and smaller at the lower first molar The computer measurements, however, were apt to be larger at both upper and lower first molars. 4. The measurements with vernier calipers showed the largest error at the lower first molar and the degree of error was variable according to the tooth while the difference of error was small in the computer measurements. 5. In the analysis for the correlation of the degree of measurement errors with the contact point deviation index and the mesio-distal crown angulation of each tooth, the measurements with vernier calipers did not show significant correlation while the measurements with computer showed slight Positive correlations. The results of this study indicate that a computer system may be useful for the measurement of tooth size in the model analysis.

  • PDF

The effectiveness of urokinase in treatment of pleural effusion in children (소아의 흉수 치료에 있어서 유로키나제 효과)

  • Nam, Ga-yeon;Park, Hee-ju
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.7
    • /
    • pp.660-664
    • /
    • 2007
  • Purpose : Pleural effusion is a common complications of pediatric bacterial pneumonia. Intrapleural administration of fibrinolytic agents such as urokinase have been used in the management of complicated parapneumonic effusions. But the safety and effectiveness of intrapleural urokinase instillations in children has not been confirmed. The aim of this study is to evaluate the safety and effectiveness of intraperitoneal urokinase in children. Methods : We reviewed a total of 29 children diagnosed as parapneumonic effusion with septation by chest CT or chest ultrasonography. We divided them into two groups. Fourteen children treated with urokinase after thoracostomy (Group A) were compared with 15 children treated only with thoracostomy (Group B). The urokinase, 3,000 IU/kg/day, was injected into the pleural cavity twice a day. Results : There was no statistical difference in sex and age between the two groups. Total drainage volume during thoracostomy in group A and B was 375.5 mL and 350.0 mL, respectively. It was not statistically significant. But the amounts of pleural fluid of group A on day 1, day 2 and day 3 were 102.5 mL, 100.0 mL, and 70.0 mL respectively and those of group B on day 1, day 2 and say 3 were 120.0 mL, 50.0 mL and 15.0 mL respectively. To compare group A with group B in the amounts of drainage volume on day 1 was not statistically significant, but the amounts of drainage volumes on day 2 and day 3 in group A were statistically more significant than group B (Day 1 P=0.371, Day 2 P=0.049, Day 3 P=0.048, respectively). The duration of fever, antibiotics, thoracostomy and total hospital days. Were not statistically significant between the two groups. But the frequency of complications in Group A was statictically significantly lower than in group B. Conclusion : Intrapleural instillation of urokinase facilitates the drainage of loculated pleural effusions, especially during the first 3 days, and it could reduce complications, such as pleural thickening, surgical managements, re-positioning of tube and re-thoracostomy. So intrapleural urokinase injection was and effective and safe treatment of pleural effusion in children (P=0.014).

Analysis of the Manufacturing Techniques for the KwangDahoe Tying on the Sword in Joseon Dynasty (조선시대 도검 패용 광다회의 제작기법 분석)

  • Baek, Je-Sun;Chung, Kwang-Young
    • Korean Journal of Heritage: History & Science
    • /
    • v.50 no.3
    • /
    • pp.64-87
    • /
    • 2017
  • Dahoe is a traditional braid in Joseon Dynasty. There are many Dahoe artifacts, which can give us a glimpse of the costume, culture, and life of that era. The study of Dahoe is necessary in various fields, but it is difficult because this manufacturing technique has been passed down from hand to hand. Few studies have been done so far. This research examines the manufacturing technique of KwangDahoe which is passed down by Maedeupjang (Decorative Knotting) and is generally used for knotting and/or tying objects. The main characteristic of TieKwangDahoe, made through the same method as WonDahoe, is the square hole in the middle. It was impossibile to remake the original braid because there is no confirmed number of the strand. Especially it is very difficult to do conservation and restoration on serious degradation state of the fiber. Therefore, it is necessary to analyze the non-destructive manufacturing techniques method for Dahoe and assess their applicability. First, we analyzed the artifacts' manufacturing technique based on the database of the Dahoe's manufacturing technique. In order to do that, we undertook schematization, restoration, morphological analyzation of the Dahoe. And then, X-ray CT scans were performed to improve the reliability of the DB. These results of scanning were interpreted based on the manufacturing technique. The selected Tie-KwangDahoe on the sword for the study are artifacts including artistic value and symbolism in Joseon Dynasty. Based on the analysis of the manufacturing technique, we found that both artifacts were made of 20-strand braid of single cross according to the length-scale measure. It was manufactured using 8-strand on left-right side, 12-strand on front-back side by the braiding manufacturing technique method Finally, this research suggests non-destructive analysis method of Dahoe's manufacturing technique is based on the database and the analysis results. I hope this research can be useful in various professional fields of Dahoe in the future. Moreover, I hope this can be of any help in preserving Korean cultural heritage.

Regeneration of a defective Railroad Surface for defect detection with Deep Convolution Neural Networks (Deep Convolution Neural Networks 이용하여 결함 검출을 위한 결함이 있는 철도선로표면 디지털영상 재 생성)

  • Kim, Hyeonho;Han, Seokmin
    • Journal of Internet Computing and Services
    • /
    • v.21 no.6
    • /
    • pp.23-31
    • /
    • 2020
  • This study was carried out to generate various images of railroad surfaces with random defects as training data to be better at the detection of defects. Defects on the surface of railroads are caused by various factors such as friction between track binding devices and adjacent tracks and can cause accidents such as broken rails, so railroad maintenance for defects is necessary. Therefore, various researches on defect detection and inspection using image processing or machine learning on railway surface images have been conducted to automate railroad inspection and to reduce railroad maintenance costs. In general, the performance of the image processing analysis method and machine learning technology is affected by the quantity and quality of data. For this reason, some researches require specific devices or vehicles to acquire images of the track surface at regular intervals to obtain a database of various railway surface images. On the contrary, in this study, in order to reduce and improve the operating cost of image acquisition, we constructed the 'Defective Railroad Surface Regeneration Model' by applying the methods presented in the related studies of the Generative Adversarial Network (GAN). Thus, we aimed to detect defects on railroad surface even without a dedicated database. This constructed model is designed to learn to generate the railroad surface combining the different railroad surface textures and the original surface, considering the ground truth of the railroad defects. The generated images of the railroad surface were used as training data in defect detection network, which is based on Fully Convolutional Network (FCN). To validate its performance, we clustered and divided the railroad data into three subsets, one subset as original railroad texture images and the remaining two subsets as another railroad surface texture images. In the first experiment, we used only original texture images for training sets in the defect detection model. And in the second experiment, we trained the generated images that were generated by combining the original images with a few railroad textures of the other images. Each defect detection model was evaluated in terms of 'intersection of union(IoU)' and F1-score measures with ground truths. As a result, the scores increased by about 10~15% when the generated images were used, compared to the case that only the original images were used. This proves that it is possible to detect defects by using the existing data and a few different texture images, even for the railroad surface images in which dedicated training database is not constructed.

Evaluation of the Usefulness of Virtual Reality Equipment for Relieving Patients' Anxiety during Whole-Body Bone Scan (전신 뼈 검사 환자의 불안감 해소를 위한 가상현실 장비의 유용성 평가)

  • Kim, Hae-Rin;Kim, Jung-Yul;Lee, Seung-Jae;Baek, Song-Ee;Kim, Jin-Gu;Kim, Ga-Yoon;Nam-Koong, Hyuk;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.27-32
    • /
    • 2022
  • Purpose When performing a whole-body bone scan, many patients are experiencing psychological difficulties due to the close distance to the detector. Recently, in the medical field, there is a report that using virtual reality (VR) equipment can give pain relief to pediatric patients with weak concentration or patients receiving severe treatment through a distraction method. Therefore, in this paper, VR equipment was used to provide psychological stability to patients during nuclear medicine tests, and it is intended to evaluate whether it can be used in clinical practice. Materials and Methods As VR equipment, ALLIP Z6 VR (ALLIP, Korea) was used and the experiment was conducted after connecting to a mobile phone. The subjects were 30 patients who underwent whole-body bone examination from September 1, 2021 to September 30, 2021. After intravenous injection of 99mTc-HDP, 3 to 6 hours later, VR equipment was put on and whole body images were obtained. After the test, a survey was conducted, and a Likert scale of 5 points was used for psychological anxiety and satisfaction with VR equipment. Hypothesis verification and reliability of the survey were analyzed using SPSS Statistics 25 (IBM, Corp., Armonk, NY, USA). Results Anxiety about the existing whole-body bone test was 3.03±1.53, whereas that of anxiety after wearing VR equipment was 2.0±1.21, indicating that anxiety decreased to 34%. When regression analysis of the effect of the patient's concentration on VR equipment on anxiety about the test, the B value was 0.750 (P<0.01) and the t value was 6.181 (P<0.01). decreased and showed an influence of 75%. In addition, overall satisfaction with VR equipment was 3.76±1.28, and the intention to reuse was 66%. The Cronbach α value of the reliability coefficient of the questionnaire was 0.901. Conclusion When using VR equipment, patients' attention was dispersed, anxiety was reduced, and psychological stability was found. In the future, as VR equipment technology develops, it is thought that if the equipment can be miniaturized and the resolution of VR content images is increased, it can be used in various clinical settings if it provides more realistic stability to the patient.