• Title/Summary/Keyword: 재료 모사

Search Result 513, Processing Time 0.028 seconds

Analytical Study for Performance Improvement of Studs for Steel Plate Concrete(SC) Walls subjected to Bending Moment (휨모멘트를 받는 강판 콘크리트(SC) 벽체에서 스터드의 성능개선을 위한 해석적 연구)

  • Cho, Sung-Gook;Lim, Jin-Sun;Jeong, Young-Do;Yi, Seong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.74-81
    • /
    • 2014
  • In this study, it was conducted to improve the performance of stud of Steel Plate Concrete(SC) walls subjected to bending moment. Non-linearity of contact interface, connection, and material properties were considered in finite element modeling of SC wall. In order to validate the analytical model, furthermore, a foregoing laboratory experiment was simulated by FEM, so that comparison between the measured result and the analysis result have be done. The size of the analytical model was determined by reflecting various references and the analyses were performed according to various shapes and arrangements of stud. Additionally, the validity of the model considering the related provisions in the KEPIC SNG standard was also considered. As a result, the optimal shape and spacing of studs was proposed through this numerical analysis and standard verification.

Analysis of Pile Head Lateral Load-Deflection Behavior of Steel-Concrete Composite Drilled Shafts (강관합성 현장타설말뚝 머리의 수평하중-변위 거동 분석)

  • Lee, Yong-An;Chung, Moon-Kyung;Park, Jae-Hyun;Lee, Ju-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.12
    • /
    • pp.97-106
    • /
    • 2011
  • To analyze the lateral load-deflection behavior of steel-concrete composite drilled shafts, a series of lateral pile load tests were performed. The test results were compared with the results from various analytical methods for lateral pile behaviors using the coefficients of subgrade reaction ($k_h$) estimated by pressuremeter test (PMT) and standard penetration test (SPT). As a result, it was found that the analytical methods using the $k_h$ estimated by SPT N value were not suitable for evaluating the pile head lateral load-deflections of the piles within the allowable deflection. However, the methods using the $k_h$ calculated from PMT were able to represent the initial lateral behavior at the head of the piles fairly well. Also, the method by the pressuremeter curve, which was applied directly to the p-y curve of the piles, offered a reasonable lateral behavior estimation by applying the correction factor to the pile materials.

Analysis for Mechanical Behavior of GFRP Rock Bolt for Permanent Support of Tunnel (영구 터널지보재로서의 활용을 위한 GFRP 록볼트의 역학적 거동 분석)

  • Sim, Jong-Sung;Kang, Tae-Sung;Lee, Yong-Taek;Kim, Hyun-Joong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.124-131
    • /
    • 2010
  • Rock Bolt generally utilizes deformed reinforcing bar welded from structural steel of which strength is higher than required for making advantageous use of the support function of ground. In the condition with highly corrosive underground water, however, problem frequently occurs on tunnel and slope stabilization in terms of repair, rehabilitation and maintenance issues due to the destruction of Rock Bolt by corrosion of steel. A structural performance evaluation for GFRP Rock Bolt was conducted for the purpose of resolving the foregoing problem and at the same time developing a permanently-usable support material. This study intended to evaluate the safety factor of GFRP Rock Bolt by implementing the slope stability interpretation via structural analysis on the basis of its structural characteristics derived from both tensile force function test and shear force function test. It is judged based on the results that GFRP Rock Bolt would secure sufficient ground stability as an alternative material for existing Steel Rock Bolt.

A Study on Impact Sound Insulation Properties of EPDM Micro Cellular Pad (에틸렌-프로필렌-디엔 삼원 공중합 (EPDM) 발포체의 충격음 저감 특성에 관한 연구)

  • Lee, Kyung-Won;Lee, Jung-Hee;Sohn, Ho-Soung
    • Elastomers and Composites
    • /
    • v.35 no.2
    • /
    • pp.138-148
    • /
    • 2000
  • In order to investigate the possibility of EPDM micro cellular pad (MCP) as an impact sound insulation product, we studied static/dynamic properties and vibration transfer characteristics of EPDM MCP depending on shape, thickness, degrees of foaming by using material test system (MTS) and lab scale mock-up test apparatus. Static/dynamic rigidity is increased when shape is simple. thickness and degrees of foaming low. We could see that dynamic stiffness is proportional to the transmissibility of EPDM MCP. When dynamic stiffness is increased, characteristic peak at transmissibility curve moves high frequency range or snows increase of maximum value of transmissibility. For lab scale mock-up test and finite element method, EPDM MCP shows low vibration velocity and superior mode shape to just concrete plus slab structure. We could confirm that possibility of EPDM MCP as a impact sound insulation product is high.

  • PDF

Analysis of Strengthening Veriables for Strengthened Bridge Decks by Externally Bonded Sheet (보강판으로 외부부착 보강된 교량 바닥판의 성능향상을 위한 변수 해석)

  • 심종성;오흥섭
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.556-565
    • /
    • 2002
  • The concrete bridge decks on the main girder will usually develop initial cracks in the longitudinal or the transverse direction due to dry shrinkage and temperature change, and as the bridge decks age the crack will gradually develop in different directions due to repeated cyclic loads. The strengthening direction of the concrete bridge deck is a very important factor in improving proper structural behavior. Therefore, in this study, theoretical analyses of strengthened bridge decks were performed using the nonlinear finite element method. To improve the accuracy of the analytical result, boundary conditions and material property of strengthening material was simulated by laboratory condition and test results, respectively. The effect of the strengthening direction and the amount of strengthening material were estimated and compared to the experimental results. The efficiency of the strengthened bridge decks by strengthening variables such as the amount, width and thickness of CFS was observed.

Numerical Investigation on Cracking of Bridge Deck Slabs with Latex Modified Concrete Overlays (라텍스 개질 콘크리트 교량 교면 포장부 균열에 대한 수치해석 연구)

  • Choi, Kyoung-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.77-84
    • /
    • 2010
  • Latex modified concrete (LMC) exhibits improved material properties including high tensile strength and durability compared with conventional concrete, and hence LMC has been used as protective layers over the bridge deck slabs to increase their service life with underlying assumption of excellent bond behavior between the LMC overlay and the concrete substrate. In this study, the effect of the primary parameters of the concrete substrate (i.e., shrinkage, stiffness and cracking capacity) as well as the LMC overlay thickness on the probability of cracking of the bridge deck slabs using LMC overlays was investigated by carrying out the finite element analysis that simulated the bond behavior of LMC overlays on normal strength concrete (NSC) and HPC bridge deck slabs. Based on the results of the numerical analysis, it is concluded that the relatively high shrinkage strains and stiffness of HPC slabs can increase its probability of cracking in bridge deck slabs using LMC overlay.

A Study on Manufacture standardization of High Strength Concrete to Use Moderate Heat Portland Cement (벨라이트계 시멘트를 이용한 고강도 콘크리트 제조표준화에 관한 연구)

  • Park, Cheol;Kim, Dong-Suck;Um, Tai-Sun;Lee, Jong-Ryul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.665-668
    • /
    • 2008
  • Recently the city construction and the concrete structures are more becoming extra weight and the efficient use of the space by the population intensively and follow in industrial intensive commerce and the residence commerce composition building which leads the high story of the building. Consequently the high rise of the building which space applies efficiently in objective which will increase continuously. Also with high rise of buildings durability it will be able to increase the life of the structure is emphasized and the concrete structure is demanding the more high strength.

  • PDF

Development and Performance of Self-Propelled Vehicles for Repairing Concrete Sewage Pipes (콘크리트 하수관로 결함부 보수를 위한 자주차 개발 및 성능평가)

  • Park, Ji-Hun;Jung, Hoe-Won;Park, Hee-Woong;Yang, In-Hwan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.3
    • /
    • pp.372-378
    • /
    • 2020
  • In this study, an experiment was conducted on the development and performance of self-propelled vehicles to repair defects in concrete sewage pipes. The self-propelled vehicle for a non-excavation repair for the sewage pipe defects was developed in consideration of the performance of the driving system, the feasibility of the repair unit, and the transportation of repair materials. In order to evaluate the performance of the developed self-propelled vehicle, a repair test was performed by simulating a defect at a connection between the main pipe and extruded one. The main sewage pipe was meade of concrete and its diameter was 500mm. Thereafter, watertightness performance was evaluated on the leakage at the repaired part. For watertightness performance, both ends of concrete sewage pipe and connected one was inserted by plugs, and then water was injected. The amount of leakage water measurement was 0.07L/㎡, indicating a value less than 0.2L/㎡ of the allowable leakage amount. Therefore, test results indicated that the self-propelled vehicle developed in this study exhibited excellent maintenance performance for repairing the sewage pipes.

Experimental Study on Internal Temperature Change Induced by Heating Element Attached to Tunnel Lining Surface (터널 라이닝 표면에 부착된 발열체로 인한 내부 온도 변화의 실험적 연구)

  • Jin, Hyunwoo;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.11
    • /
    • pp.35-40
    • /
    • 2017
  • The rearside of concrete lining of tunnels constructed in cold region might experience on freezing due to the low temperature. This causes damage of concrete lining resulting in adverse affect on the durability as well as integrity of tunnel structure by causing damage to the concrete lining. In order to prevent the rearside of tunnel lining from freeing, the temperature change inside the concrete lining was measured by attaching a heating element to the tunnel lining surface and generating heat for a certain period of time. A special freezing chamber was developed to conduct the experiments considering in-situ environment. The carbone nanotube (CNT) was used as a heating element in this study. The temperature distribution of the concrete lining was measured by applying the heat to the heating element. The effect of the outside temperature and heating duration were analyzed.

Ultimate Analysis of RC Beam with Unbonded Prestressing CFRP Plate (비부착 CFRP 판으로 긴장된 RC 보의 극한해석)

  • Lee, Jae-Seok;Choi, Kyu-Chon;Park, Young-Ha
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.249-252
    • /
    • 2008
  • A study for the nonlinear analysis method of RC(Reinforced Concrete) beams with unbonded prestressing CFRP plate is presented. The cross-section of RC beam element is idealized as an assemblage of concrete and reinforcing steel fibers in order to account for varied material properties within the cross-section of the element. The unbonded CFRP plate is modeled as a series of the CFRP plate segments each of which is linked to the RC beam element, but slips without any resistance to simulate the unbonded behavior of the CFRP plate. The stress of each CFRP plate segment is redistributed iteratively using the force equilibrium relationship at each common node until it reaches at the same stress level. To evaluate the validity of the proposed analysis method, the results of ultimate analysis of the reinforced concrete beams with unbonded prestressing CFRP plates are compared with the experimental results obtained from other investigators. The proposed analysis method is found to predict ultimate behaviors of these beams fairly well.

  • PDF