• Title/Summary/Keyword: 장치면적

Search Result 567, Processing Time 0.026 seconds

Analysis of the Failure Mode in a Homogeneous Sandy Slope Using Model Test (모형실험을 이용한 균질한 사질토 사면의 붕괴형상 분석)

  • Song, Young-Suk;Park, Joon-Young;Kim, Kyeong-Su
    • The Journal of Engineering Geology
    • /
    • v.32 no.2
    • /
    • pp.209-219
    • /
    • 2022
  • To experimentally investigate the variation of soil characteristics in slope during rainfall and the shape of slope failure, the model test was performed using soil box and artificial rainfall simulator. The model test of slope formed by the homogenous sand was performed, and the saturation pattern in the model slope due to rainfall infiltration was observed. The slope model with the inclination of 35° was set up on the slope of 30°, and the rainfall intensity of 50 mm/hr was applied in the test. The soil depth of 35 cm was selected by considering the size of soil box, and the TDR (time domain reflectometry) sensors were installed at various depths to investigate the change of soil characteristics with time. As the result of model test, the slope model during rainfall was saturated from the soil surface to the subsurface, and from the toe part to the crest part due to rainfall infiltration. That is, the toe part of slope was firstly saturated by rainfall infiltration, and then due to continuous rainfall the saturation range was enlarged from the toe part to the crest part in the slope model. The failure of slope model was started at the toe part of slope and then enlarged to the crest part, which is called as the retrogressive failure. At the end of slope failure, the collapsed area increased rapidly. Also, the mode of slope failure was rotational. Meanwhile, the slope failure was occurred when the matric suction in the slope was reached to the air entry value (AEV) estimated in soil-water characteristic curve (SWCC).

Prediction of Crack Distribution for the Deck and Girder of Single-Span and Multi-Span PSC-I Bridges (단경간 및 다경간 PSC-I 교량의 바닥판 및 거더의 균열분포 예측)

  • Hyun-Jin Jung;Hyojoon An;Jaehwan Kim;Kitae Park;Jong-Han Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.102-110
    • /
    • 2023
  • PSC-I girder bridges constitute the largest proportion among highway bridges in Korea. According to the precision safety diagnosis data for the past 10 years, approximately 41.3% of the PSC-I bridges have been graded as C. Furthermore, with the increase in the aging of bridges, preemptive management is becoming more important. Damage and deterioration to the deck and girder with a long replacement cylce can have considerable impacts on the service and deterioration of a bridge. In addition, the high rate of device damages, including expansion joints and bearings, necessitates an investigation into the influence of the device damage in the structural members of the bridge. Therefore, this study defined representative PSC-I girder bridges with single and multiple spans to evaluate heterogeneous damages that incorporate the damage of the bridge member and device with the deterioration of the deck. The heterogeneous damages increased a crack area ratio compared to the individual single damage. For the single-span bridge, the occurrence of bearing damage leads to the spread of crack distribution in the girder, and in the case of multi-span bridges, expansion joint damage leads to the spread of crack distribution in the deck. The research underscores that bridge devices, when damaged, can cause subsequent secondary damage due to improper repair and replacement, which emphasizes the need for continuous observation and responsive action to the damages of the main devices.

Evaluation Methods for the Removal Efficiency of Physical Algal Removal Devices (물리적 녹조 제거 장치의 제거 효율 평가 방안)

  • Pyeol-Nim Park;Kyung-Mi Kim;Young-Cheol Cho
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.6
    • /
    • pp.419-430
    • /
    • 2023
  • In response to the periodic occurrence of cyanobacterial blooms in Korean freshwaters, various types of cyanobacteria removal technologies are being developed and implemented. Due to the differing principles behind these technologies, it is difficult to compare and evaluate their removal efficiencies. In this study, a standardized method for evaluating cyanobacteria removal efficiency was proposed by utilizing the results of removal operations using a mobile cyanobacteria removal device in the Seohwacheon area of Daechung Reservoir. During removal operations, the decrease in chlorophyll-a (chl-a) concentration (ΔChl-a) in the working area was calculated based on the amount of collected sludge, the efficiency rate, and the concentration of chl-a. Additionally, the required working days (WD) to reduce the chl-a concentration to 1 mg/m3 in the target area was calculated based on the area of the target zone, the maximum daily working area, and the efficiency rate. A method for calculating the cyanobacteria removal capacity was proposed based on the reduction rate of chl-a concentration in the water before and after the operation, the treatment capacity of the removal technology, and the water volume of the target area. The cyanobacteria removal capacity of the mobile cyanobacteria removal device used in this study was 6.64%/day (targeting the Seohwacheon area of Daechung Reservoir, approximately 500,000 m2), which was higher compared to other physical or physicochemical cyanobacteria removal technologies (0.02~4.72%/day). Utilizing the evaluation method of cyanobacteria removal efficiency presented in this study, it will be possible to compare and evaluate the cyanobacteria removal technologies currently being applied in Korea. This method could also be used to assess the performance and efficiency of physical or physicochemical combined cyanobacteria removal techniques in the "Guidelines for the Installation and Operation of Algae Removal Facilities and the Use of Algae Removal Agents" operated by the National Institute of Environmental Research.

Development of Sewage Treatment Apparatus for Detached House in Agricultural Village by Natural Purification Method (자연정화공법에 의한 농촌 전원 독립가구 하수처리장치 개발)

  • Seo, Dong-Cheol;Park, Mi-Ryoung;Kim, Hyung-Jun;Cho, In-Jae;Lee, Hong-Jae;Sung, Sun-Jin;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.3
    • /
    • pp.202-210
    • /
    • 2006
  • To develop small-scale sewage treatment apparatus for detached house of agricultural village, a small-scale sewage treatment apparatus by natural purification method that consisted of packaged form of aerobic, anoxic and anaerobic bed was constructed. The efficiency of sewage treatment according to the sewage treatment method, sewage loading, and the injection method of sewage were investigated for small-scale sewage treatment apparatus of packaged form of aerobic, anoxic and anaerobic bed. The removal rate of pollutants according to the sewage treatment method for small-scale sewage treatment apparatus was high in the order of aerobic-anoxic-anoxic bed < aerobic-anoxic-anaerobic bed. The optimum filter media in small-scale sewage treatment apparatus was a broken stone. The removal rate of pollutants according to sewage loading in small-scale sewage treatment apparatus was high in the order of $1,200L/m^2{\cdot}day\fallingdotseq900L/m^2{\cdot}day\fallingdotseq600L/m^2{\cdot}day$. The removal rate of pollutants according to injection method of sewage in small-scale sewage treatment apparatus was high in the order of continuous injection $\fallingdotseq$ intermittent injection. When loaded under the optimum conditions, removal rate of BOD, COD, SS, T-N and T-P were 99, 95, 99, 83 and 96%, respectively, through this 3-stepped small-scale treatment apparatus arrayed with the order of aerobic, anoxic and anaerobic bed.

A Study on Neutron Resonance Energy of 180Ta below 1eV Energy (1 eV 이하 에너지 영역에서의 180Ta 동위원소의 중성자공명에 대한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.287-292
    • /
    • 2014
  • In this study, the neutron capture cross section of $^{180}Ta$(natural existence ratio: 0.012 %) obtain by measuring has been compared with the evaluated data for the capture data. In generally, the neutron capture resonance is defined as Breit-Wigner formula. The formula consists of the resonance parameters such as neutron width, total width and neutron width. However in the case of $^{180}Ta$, these are very poor experimental neutron capture cross section data and resonance information in below 10 eV. Therefore, in the study, we analyzed the neutron resonance of $^{180}Ta$ with the measuring the prompt gamma-ray from the sample. And the resonance was compared with the evaluated data by Mughabghab, ENDF/B-VII, JEFF-3.1 and TENDL 2012. Neutron sources from photonuclear reaction with 46-MeV electron linear accelerator at Research Reactor Institute, Kyoto University used for cross section measurement of $^{180}Ta(n,{\gamma})^{181}Ta$ reaction. $BGO(Bi_4Ge_3O_{12})$ scintillation detectors used for measurement of the prompt gamma ray from the $^{180}Ta(n,{\gamma})^{181}Ta$ reaction. The BGO spectrometer was composed geometrically as total energy absorption detector.

Practical Application of Mn-Cu Metal Catalyst for the Removal of Acetaldehyde (아세트알데히드 제거를 위한 Mn-Cu 금속촉매 실용화에 관한 연구)

  • Jung, Sung-Chul;Lee, Seung-Hwan
    • Journal of Digital Convergence
    • /
    • v.10 no.8
    • /
    • pp.201-210
    • /
    • 2012
  • Because sensing odor varies depending on each person, even if the odor is released in line with the legal emission permission concentration levels, it can still become a social issue if a civil complaint is made. The purpose of this research is to study the possibility of putting Mn-Cu metallic oxide catalysts into practical use to economically eliminate acetaldehyde which produces a odor in the industrial process. An optimal operating parameter to eliminate acetaldehyde was deduced through a performance evaluation in the research laboratory and the performance was verified by applying the parameter into an actual facility as an on-the-site experiment through a Scale-up of pilot size. The operating temperature of the metallic oxide catalysts researched so far was at the minimum close to $220^{\circ}C$, and the $220^{\circ}C$ elimination efficiency was 50% or below. However, having experimented by using a Mn-Cu metallic oxide catalyst in this research, optimum elimination efficiency showed when space velocity (GHSV) was equal to or below 6,000 $hr^{-1}$. The average elimination efficiency was 61.2% when the catalyst controlling temperature was $120^{\circ}C$, 93.3% when the catalyst controlling temperature was $160^{\circ}C$, and 94.9% when catalyst controlling temperature was $180^{\circ}C$, thereby reflecting high elimination efficiency. The specific surface area of the catalyst was $200m^2/g$ before use, however, was reduced to $47.162m^2/g$ after 24 months and therefore showed that despite the decrease in specific surface area as time passed, there was no significant influence on the performance. Having operated Mn-Cu metallic oxide catalyst systems for at least two years on a site where there was no inflow of toxins like sulfur compounds and acidic gases, we were able to confirm that elimination efficiency of at least 90% was maintained.

Elliptic Curve Cryptography Coprocessors Using Variable Length Finite Field Arithmetic Unit (크기 가변 유한체 연산기를 이용한 타원곡선 암호 프로세서)

  • Lee Dong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.1
    • /
    • pp.57-67
    • /
    • 2005
  • Fast scalar multiplication of points on elliptic curve is important for elliptic curve cryptography applications. In order to vary field sizes depending on security situations, the cryptography coprocessors should support variable length finite field arithmetic units. To determine the effective variable length finite field arithmetic architecture, two well-known curve scalar multiplication algorithms were implemented on FPGA. The affine coordinates algorithm must use a hardware division unit, but the projective coordinates algorithm only uses a fast multiplication unit. The former algorithm needs the division hardware. The latter only requires a multiplication hardware, but it need more space to store intermediate results. To make the division unit versatile, we need to add a feedback signal line at every bit position. We proposed a method to mitigate this problem. For multiplication in projective coordinates implementation, we use a widely used digit serial multiplication hardware, which is simpler to be made versatile. We experimented with our implemented ECC coprocessors using variable length finite field arithmetic unit which has the maximum field size 256. On the clock speed 40 MHz, the scalar multiplication time is 6.0 msec for affine implementation while it is 1.15 msec for projective implementation. As a result of the study, we found that the projective coordinates algorithm which does not use the division hardware was faster than the affine coordinate algorithm. In addition, the memory implementation effectiveness relative to logic implementation will have a large influence on the implementation space requirements of the two algorithms.

Evaluation of Usefulness of Image by Using New Compression Paddle for Mammoplasty Patient During Mammography (유방촬영 시 유방보형물 환자에 대한 새로운 압박대 적용의 유용성 평가)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.229-235
    • /
    • 2015
  • Mammoplasty is currently increasing not only for cosmetic surgery, but as well as for the recovery after breast cancer surgery. The prostheses inserted into the breasts of women who have undergone mammoplasty, hide the breast substances and it is becoming increasingly difficult to diagnose breast disease, and fear is growing by the concern of the prostheses bursting by the strap. So we want to develop a strap applicable to women with prostheses inserted, to determine the usefulness, and we also want to compare the utility by comparing the total area of the Inner and Outer parts of the breast and Posterior Nipple Line (PNL), after obtaining video by applying the existing strap and the developed strap to phantom of the prostheses inserted patient shape. When the pressure by the developed pressure, the total area increased by 10.09% from CC view to $9,813.797mm^2$, 3.88% from CC-ID view to $7,621.531mm^2$, PNL increased by 3.41% from CC view to $90.916mm^2$, 1.64% from CC-ID view to$75.357mm^2$. And the breast tissue of the thorax side increased 3.53% from CC view to $177.725mm^2$, and 6.57% from CC-ID view to $152.510mm^2$, and we could verify that the prostheses were completely eliminated in the CC-ID images of developed strap, compared with the existing strap.

Preparation of Nano-Sized ITO Powder from Waste ITO Target by Spray Pyrolysis Process (폐(廢) ITO 타겟으로부터 분무열분해(噴霧熱分解) 공정(工程)에 의한 ITO 나노 분말(粉末) 제조(製造))

  • Yu, Jae-Keun;Kang, Seong-Gu;Sohn, Jin-Gun
    • Resources Recycling
    • /
    • v.16 no.1 s.75
    • /
    • pp.28-36
    • /
    • 2007
  • Nano-sized ITO powders with the average particle size below 50 nm were synthesized from complex acid solution dissolved the ITO target into hydrochloric acid by a spray pyrolysis process, and the influences of reaction factors as reaction temperature and concentration of raw material solution were investigated. As the reaction temperature increases from 800 to $1000^{\circ}C$, the average particle size of the ITO powder increases from 40 nm to 100 nm, the microstructure gradually becomes solid, individual particles independently appear with the shape of polygon, the particle size distribution becomes increasingly irregular, the XRD peak intensity gradually increases and the specific surface area decreases. As the concentration of the raw material solution increases from 50g/l to 400g/l, the average particle size of ITO powder gradually increases, yet the particle size distribution appears more irregular. When the concentration is at 50 g/l, the average particle size of ITO powder is below 30 nm and the particle size distribution appears comparatively uniform. Nevertheless, when the concentration reaches 400 g/l, which is close to e saturated concentration, the particle size distribution appears extremely irregular, and the particles with the size ranging from 20 nm to 100 nm coexist. Along with the concentration rise, the XRD peak intensity gradually increases, yet the specific surface area decreases.

유전자 변형 농산물의 개발 실태와 전망

  • 최양도;정종주
    • Proceedings of the Korean Society of Food Hygiene and Safety Conference
    • /
    • 2002.05a
    • /
    • pp.3-42
    • /
    • 2002
  • 21세기에는 인구의 폭발적 증가와 함께 가속화된 산업화로 말미암아 경지 면적은 줄고 농업 환경은 더욱 피폐해질 것으로 예상된다. 지금도 이미 화석 에너지원의 고갈로 대체 에너지 개발이 시급히 요구되고 있으며, 지구의 자연 환경 보존 목소리도 그 어느 때 보다 높다. 한마디로 식량, 에너지, 환경 문제가 새 세기에 우리가 시급히 해결해야할 과제로 주어져 있다. 이에 과학계에서는 식량 및 대체 에너지원의 공급을 증대시키고 환경을 보존할 수 있는 보편적인 수단으로 환경 친화적 유전자 변형 (GM)작물의 활용이 제시되고있다. 따라서 선진국들은 이의 기반이 되는 식물유전체 연구에 대규모 투자를 아끼지 않고 있으며, 이를 이 용한 식물 생명공학산업을 국가 전략 산업으로 집중 육성하고 있다. GM작물 제조 기술은 유용 유전자의 발굴 및 재조합, 식물세포로의 이식 및 재분화를 통한 완전한 식물체 재생, 이를 품종으로 실용화하는 단계로 구성되어 있다. GM작물은 1983년 항생제 저항성 담배가 개발된 것을 시점으로 하여, 1994년에는 연화지 연 토마토 Flaver Saver이후 지금까지 개발 실용화된 작물은 제초제 저항성 콩, 카놀라, 목화, 그리고 해충 저항성 옥수수 등이 있으며,2001년까지 세계적으로 상품화 승인을 얻은 경우는 15 작물 68품종에 이른다. 2001년 경우 GM작물 종자시장은 약 30억 달러에 달하고 있으며, 미국, 아르헨티나, 캐나다 등 세계적으로 52.6백만 ha에 이르는 면적에서 재배되었다. 그러나 GM농산물의 식품 및 환경 안전성에 대한 의구심이 일기 시작하였고, 따라서 이의 생산 및 소비에 대한 전반적 인 문제가 뜨거운 쟁점으로 부각되기도 하였다. 이 에 각국 정부는 객관적 인 안전성을 확보하기 위한 제도적인 장치를 마련하고 있으며, 아울러 과학기술자들은 더욱 안전한 형질전환 기술 개발을 도모하고 있다. 다음 세대의 GM작물은 단순한 제초제 및 병해충 저항성을 넘어서서 특정 영양 또는 건강기능성을 향상시켜 부가가치를 증가시킨 신품종 맞춤작물이 지속적으로 개발 상업화될 것이다. 따라서 고유성을 가진 유용 유전자의 대량 확보 여부가 산업적 경쟁력을 결정하게 될 것이다. 지금까지 개별 유전자 중심으로 이루어지던 유용 유전자 발굴 작업은 유전체학의 출현으로 규모가 대량화되고 그 효율이 증진되었다. 따라서 진 각국은 유용 유전자 발굴에 국가적 차원의 역량을 집중하고 있다. 그러나 우리나라는 정부와 민간의 소규모 지원으로 근근히 기술 습득 차원에 머물러 왔으며, 산업적 경쟁력의 무기가 될 고유한 유용 유전자와 형질전환 기술이 거의 없는 어려운 상황에 놓여 있다. 최근 정부가 시작한 생명공학 분야 대규모 연구지원 사업 기대를 모아 보며 이 분야 과학기술자들의 노력을 촉구한다.

  • PDF