• Title/Summary/Keyword: 장착위치

Search Result 723, Processing Time 0.039 seconds

The Effects of a MR Torso Coil on CT Attenuation Correction for PET (PET/CT 검사에 있어서 MR Torso Coil의 CT 감쇄보정에 대한 영향 평가)

  • Lee, Seung Jae;Bahn, Young Kag;Oh, Shin Hyun;Gang, Cheon-Gu;Lim, Han Sang;Kim, Jae Sam;Lee, Chang Ho;Seo, Soo-Hyun;Park, Yong Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.81-86
    • /
    • 2012
  • Purpose : Combined MR/PET scanners that use the MRI for PET AC face the challenge of absent surface coils in MR images and thus cannot directly account for attenuation in the coils. To make up for the weak point of MR attenuation correction, Three Modality System (PET/CT +MR) were used in Severance hospital. The goal of this work was to investigate the effects of MR Torso Coil on CT attenuation correction for PET. Materials and Methods : PET artifacts were evaluated when the MR Torso Coil was present of CTAC data with changing various kV and mA in uniformity water phantom and 1994 NEMA cylinderical phantom. They evaluated and compared the following two scenarios: (1) The uniform cylinder phantom and the MR Torso Coil scanned and reconstructed using CT-AC; (2) 1994 NEMA cylinderical phantom and the MR Torso Coil scanned and reconstructed using CT-AC. Results : Streak artifacts were present in CT images containing the MR Torso Coil due to metal components. These artifacts persisted after the CT images were converted for PET-AC. CT scans tended to over-estimate the linear attenuation coefficient when the kV and mA is increasing of the metal components when using conventional methods for converting from CT number. Conclusion : The presence of MR coils during PET/CT scanning can cause subtle artifacts and potentially important quantification errors. Alternative CT techniques that mitigate artifacts should be used to improve AC accuracy. When possible, removing segments of an MR coil prior to the PET/CT exam is recommended. Further, MR coils could be redesigned to reduce artifacts by rearranging placement of the most attenuating materials.

  • PDF

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

Effects of Hemorrhage on the Electroencephalograms in Dogs Anesthetized with Ketamine, Propofol and Isoflurane (출혈이 Ketamine, Propofol, Isoflurane 마취견의 뇌파에 미치는 영향)

  • Yoon, In-Sub;Jang, Hwan-Soo;Lim, Jae-Hyun;Kwon, Young-Sam;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.26 no.6
    • /
    • pp.539-546
    • /
    • 2009
  • The effect of hemorrhage on the electroencephalogram(EEG) was investigated in fifteen mixed-breed dogs anesthetized with ketamine, propofol and isoflurane. Animals were randomly allocated to three groups (n = 5) by anesthetic agents; group 1 (ketamine 5 mg/kg, IV), group 2 (propofol $156\;{\mu}g$/kg/min, IV) and group 3 (isoflurane 2.0% end-tidal concentration). Medetomidine ($40\;{\mu}g$/kg, IM) was used in all dogs as a preanesthetic agent. Recording electrode for EEG was positioned at CZ. EEG, heart rate, systolic/diastolic blood pressure, $pCO_2$, $pO_2$ and blood pH were measured before anesthesia, after anesthesia and after every bleedings. Three bleedings were accomplished by drawing blood through the femoral artery catheter at a rate of 7 ml/kg (10% of total blood volume) for 10 minutes. In the course of hemorrhage, a systolic/diastolic pressure continuously decreased in all groups. The $pCO_2$ values and heart rates were increased in all groups. The $pO_2$ values were most significantly increased in group 1 compared with those in other groups. The pH values were not significantly changed. On statistical analysis of EEG, there was no significant changes in group 1 and 3. But in group 2, band 3, 4 and 7 were significantly altered after 2nd and 3rd bleeding. Power alterations of band 3, 4 and 7 were thought to be related with hemorrhage over 20% of total blood volume in group 2. In conclusion, the regulation of infusion rate would be considered when a dog, anesthetized with propofol, bleed over 20% of total blood volume.

Evaluation of clinical status of removable partial dentures (가철성 국소의치의 임상적 상태에 대한 평가)

  • Yang, Dong-Seok;Cho, Uk;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Mi-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.320-327
    • /
    • 2009
  • Statement of Problem: Although many efforts have been continually made to estimate long term prognosis of removable partial dentures, the complication of removable partial dentures was still found because of inaccurate fabrication procedure and improper maintenance care. Purpose: The purpose of this study was to evaluate the clinical status of removable partial dentures. Material and methods: A total of 112 individuals with 153 removable partial dentures (35 - 87 years, 64 women and 48 men) were examined by intra-oral examination, diagnostic cast and radiographic examination. Results and conclusion: The results of this study were as follows: 1. Length of service of removable partial dentures was $5.3{\pm}4.3$ years (mean), 4.0 years (median). 2. A total of 45 removable partial dentures were considered failures. The loss of 18 abutments of 369 was founded. 3. Type of arch, Kennedy classification and type of opposite dentition were found to have no influence on longevity and success rate of removable partial dentures (P > .05). 4. Most common major connector was the palatal plate in maxilla and the number of lingual bar and linguoplate designed in mandible were similar. 5. The circumferential type retainer was the most commonly used retainer. 6. Sixty-three percent of the class I and II removable partial dentures incorporated indirect retention into the design. 7. Approximately 81% of the removable partial dentures had at least one defect. Excessive wear of posterior teeth (27.9%), lack of integrity (23.2%), lack of stability (22.6%) were frequent defects of removable partial dentures.

Size and Retention of Tongue Bulb for Tongue Retaining Device (혀 유지구의 크기와 유지력 평가)

  • Park, Nam-Seon;Lee, Ki-Ho;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.283-292
    • /
    • 2007
  • In several treatment modalities for snoring and obstructive sleep apnea (OSA), oral appliances mainly including mandibular advancement appliance (MAA) and tongue retaining device (TRD) are recognized as a non-invasive, reversible alternative with favorable results. Tongue bulb is a major component of TRD which prevents the tongue from approaching the posterior wall of the pharynx and can be combined with MAA. Determination of tongue bulb size for the patient is important for therapeutic effect, but frequently needs time-consuming work. For effective fabrication and standardization of tongue bulbs, this study aimed to categorize tongue bulb size for healthy young men and to examine its relation with maximum retention force and with physical parameters including tongue-related variables. 36 non-snoring, asymptomatic young men with normal occlusion were voluntarily participated in this study (mean age: $24.47{\pm}2.58$ years). Experimental procedures consisted of prefabrication of tongue bulb set (20 types with a width of 27-36mm and thickness of 8 and 10 mm), determination of tongue bulb size and the maximum retention force for each subject, and measurement of physical parameters including body mass index (BMI), neck circumference and width, thickness and length of tongue. This study showed that there was significant difference of retention force among the bulb size-related groups both in upright and supine position (p<0.05) and that retention force increased with bulb size. Correlation of tongue bulb size with physical parameters was not clearly verified and there was no significant difference in retention force between upright and supine positions. Based on our results, it can be suggested that retention force relates with tongue bulb size, ultimately with tongue volume. A further study needs to be performed in the patients with snoring and OSA.

Complication and Failure Analysis of Fixed Restorations (고정성 보철물과 연관된 합병증과 실패에 관한 조사)

  • Yun, Mi-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.149-159
    • /
    • 2011
  • Restoring and replacing teeth with fixed prostheses commonly used in dental practice. Because of improper oral hygiene care and inaccurate laboratory procedure, complication of fixed prostheses was found in the mouth of patient. Although many efforts have been continually made to obtain the data of long term prognosis of fixed prostheses, it was difficult to do it. The purpose of this study was to evaluate the clinical status of fixed prostheses to improve the quality of dental care. In order to assess the clinical status of fixed prostheses, a total of 154 individuals (aged 22-82, 88 women and 66 men loaded with 578 unit of fixed prostheses, and 423 abutments) who visited the Department of Prosthodontics, Pusan National University Hospital, between January 2009 to December 2009 and removed old fixed prostheses were examined. The results of this study were as follows: 1. Length of service of fixed prostheses was $10.3{\pm}05.5$ years (mean), 10.0 years (median). 2. Location of fixed prostheses was found to have statistically significant influence on longevity of fixed prostheses (P<.05). The longevity of fixed prostheses was high in anterior-posterior combination region (mean:13.1, median:13.5) than anterior and posterior region. 3. Longevity of fixed prostheses made of metal was longest (mean:13.3, median:12.3). 4. Number of units in fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 5. Condition of opposing dentition was found to have statistically significant influence on longevity of fixed prostheses (P>.05). The fixed prostheses lasted longest when opposed by complete denture (mean:17.1, median:19.7), removable partial denture, fixed prosthesis and natural dentition trailing behind (P<.05) 6. Periodontal disease (37.5%), dental caries (19.0%), defective margin (18.4%) were frequent complications. In 33.1% of the cases, abutment state after removing fixed prostheses was needed to be extracted.

Complication and Failure Analysis of Endodontically Treated Teeth Restored with Post and Cores (포스트로 수복한 근관 치료된 치아의 임상적 상태에 대한 평가)

  • Yun, Mi-Jung;Kim, Mu-Hyon;Jeong, Chang-Mo;Huh, Jung-Bo;Jeon, Yeong-Chan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.359-370
    • /
    • 2012
  • The endodontically treated tooth is generally restored with post and core, owing to the brittle and the loss of large amount of tooth structure. The purpose of this study was to evaluate the clinical status of fixed prostheses to improve the quality of dental care. In order to assess the clinical status of fixed prostheses, a total of 101 individuals (aged 30-89, 66 women and 35 men loaded with 125 fixed prostheses) who treated in the Department of Prosthodontics, Pusan National University Dental Hospital, between January 1990 to December 2005 were examined. The results of this study were as follows: 1. Length of service of fixed prostheses was $9.7{\pm}3.4$ years (mean), 11.1 years (median). 2. Age and sex of patient was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 3. Location of fixed prostheses was found to have statistically significant influence on longevity of fixed prostheses (P<.05). The longevity of fixed prostheses was low in anterio-posterior combination region (median:9.2 years). 4. Longevity of fixed prostheses made of base metal ceramic(median:12.0 years) and noble metal ceramic (median:11.3 years) is long (P<.05). 5. Number of units in fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 6. Condition of opposing dentition was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 7. Dental caries, periapical disease, tooth fracture were frequent complications. In 51.9% of the cases, abutment state after removing fixed prostheses was needed to be extracted.

Development and Application of the High Speed Weigh-in-motion for Overweight Enforcement (고속축하중측정시스템 개발과 과적단속시스템 적용방안 연구)

  • Kwon, Soon-Min;Suh, Young-Chan
    • International Journal of Highway Engineering
    • /
    • v.11 no.4
    • /
    • pp.69-78
    • /
    • 2009
  • Korea has achieved significant economic growth with building the Gyeongbu Expressway. As the number of new road construction projects has decreased, it becomes more important to maintain optimal status of the current road networks. One of the best ways to accomplish it is weight enforcement as active control measure of traffic load. This study is to develop High-speed Weigh-in-motion System in order to enhance efficiency of weight enforcement, and to analyze patterns of overloaded trucks on highways through the system. Furthermore, it is to review possibilities of developing overweight control system with application of the HS-WIM system. The HS-WIM system developed by this study consists of two sets of an axle load sensor, a loop sensor and a wandering sensor on each lane. A wandering sensor detects whether a travelling vehicle is off the lane or not with the function of checking the location of tire imprint. The sensor of the WIM system has better function of classifying types of vehicles than other existing systems by detecting wheel distance and tire type such as single or dual tire. As a result, its measurement errors regarding 12 types of vehicle classification are very low, which is an advantage of the sensor. The verification tests of the system under all conditions showed that the mean measurement errors of axle weight and gross axle weight were within 15 percent and 7 percent respectively. According to the WIM rate standard of the COST-323, the WIM system of this study is ranked at B(10). It means the system is appropriate for the purpose of design, maintenance and valuation of road infrastructure. The WIM system in testing a 5-axle cargo truck, the most frequently overloaded vehicle among 12 types of vehicles, is ranked at A(5) which means the system is available to control overloaded vehicles. In this case, the measurement errors of axle load and gross axle load were within 8 percent and 5 percent respectively. Weight analysis of all types of vehicles on highways showed that the most frequently overloaded vehicles were type 5, 6, 7 and 12 among 12 vehicle types. As a result, it is necessary to use more effective overweight enforcement system for vehicles which are seriously overloaded due to their lift axles. Traffic volume data depending upon vehicle types is basic information for road design and construction, maintenance, analysis of traffic flow, road policies as well as research.

  • PDF

A study on the effect of collimator angle on PAN-Pelvis volumetric modulated arc therapy (VMAT) including junction (접합부를 포함한 PAN-전골반암 VMAT 치료 계획 시 콜리메이터 각도의 영향에 관한 고찰)

  • Kim, Hyeon Yeong;Chang, Nam Jun;Jung, Hae Youn;Jeong, Yun Ju;Won, Hui Su;Seok, Jin Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.61-71
    • /
    • 2020
  • Purpose: To investigate the effect of collimator angle on plan quality of PAN-Pelvis Multi-isocenter VMAT plan, dose reproducibility at the junction and impact on set-up error at the junction. Material and method: 10 adult patients with whole pelvis cancer including PAN were selected for the study. Using Trubeam STx equipped with HD MLC, we changed the collimator angle to 20°, 30°, and 45° except 10° which was the default collimator angle in the Eclipse(version 13.7) and all other treatment conditions were set to be the same for each patient and four plans were established also. To evaluate these plans, PTV coverage, coverage index(CVI) and homogeneity index (HI) were compared and clinical indicators for each treatment sites in normal tissues were analyzed. To evaluate dose reproducibility at the junction, the absolute dose was measured using a Falmer type ionization chamber and dose changes at the junction were evaluated by moving the position of the isocenter in and out 1~3mm and setting up the virtual volume at the junction. Result: CVI mean value was PTV-45 0.985±0.004, PTV-55 0.998±0.003 at 45° and HI mean value was PTV-45 1.140±0.074, and PTV-55 1.031±0.074 at 45° which were closest to 1. V20Gy of the kidneys decreased by 9.66% and average dose of bladder and V30 decreased by 1.88% and 2.16% at 45° compared to 10° for the critical organs. The dose value at the junction of the plan and the actual measured were within 0.3% and within tolerance. At the junction, due to set-up error the maximum dose increased to 14.56%, 9.88%, 8.03%, and 7.05%, at 10°, 20°, 30°, 45°, and the minimum dose decreased to 13.18%, 10.91%, 8.42%, and 4.53%, at 10°, 20°, 30°, 45° Conclusion: In terms of CVI, HI of PTV and critical organ protection, overall improved values were shown as the collimator angle increased. The impact on set-up error at the junction by collimator angle decreased as the angle increased and it will help improve the anxiety about the set up error. In conclusion, the collimator angle should be recognized as a factor that can affect the quality of the multi-isocenter VMAT plan and the dose at the junction, and be careful in setting the collimator angle in the treatment plan.

Evaluation of the Accuracy and usability of Trigger mode in Respiratory Gated Radiation Therapy (호흡동조방사선치료를 위한 Trigger mode 투시영상 획득 시 호흡 속도에 따른 정확성 평가 - Phantom Study)

  • Park, je wan;Kim, min su;Um, ki cheon;Choi, seong hoon;Song, heung kwon;Yoon, in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.25-33
    • /
    • 2021
  • Purpose : The purpose of this study is to evaluate the accuracy and usefulness of the Trigger mode for the Respiratory Gated Radiation Therapy (RGRT) Materials and methods : A QUASAR respiratory phantom that inserted a 3 mm fiducial marker (a gold marker) was used to estimate the accuracy of the Trigger mode. And the 20 bpm was used as reference respiration rate in this study. The marker that placed at the center of the phantom was contoured, and the lower threshold of a gating window was fixed at 2.0 mm using an OBI with Truebeam STxTM. The upper threshold was measured every 0.5 mm from 1.0 mm to 3.0 mm. The respiration rates were changed every 10 bpm from 10 bpm to 60 bpm. We repeatedly measured five times to check the error rate of the trigger mode in the same condition. Result : The differences of a distance from a peak phase to upper threshold, 1.0 to 3.0 mm at a 20 bpm as a reference for 3 days in a row were 0.68±0.05 mm, 0.91±0.03 mm, 1.23±0.03 mm, 1.42±0.04 mm, and 1.66±0.06 mm, respectively. Measurement result of changes in respiratory rate compared to baseline respiratory rate in maximum absolute difference. The coefficient of determination (R2) to estimate the correlation between the respiration velocity and variation of absolute difference was on average 0.838, 0.887, 0.770, 0.850, and 0.906. The p-values of all the variables were below 0.05. Conclusion : Using Trigger mode during respiratory gated radiation therapy (RGRT), accuracy and usefulness of trigger mode at reference breathing rate were confirmed. However, inaccuracies depending on the rate of breathing it could be uncertain in case of respiration rate is faster than 20 bpm as a standard respiration rate compared to slower than 20 bpm. Consequently, when conducting a RGRT using the trigger mode, real time monitoring is required with well educated respiration.