• Title/Summary/Keyword: 장비 상태감시

Search Result 95, Processing Time 0.026 seconds

Development of AMI NMS (Network Management System) using SNMP for Network Monitoring of Meter Reading Devices (원격검침 설비의 네트워크 상태감시를 위한 SNMP 기반의 저압 AMI 망관리시스템 개발)

  • Kim, Young-Il;Park, So-Jeong;Kim, Young-Jun;Jung, Nam-Jun;Choi, Moon-Suk;Park, Byung-Seok
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.259-268
    • /
    • 2016
  • KEPCO installed AMI (Advanced Metering Infrastructure) metering system for low-voltage customers from 2008. AMI metering system of KEPCO has operated 2.55 million customers and will plan to operate 22 million customers until 2020. KEPCO developed AMI NMS (Network Management System) to operate the meter reading network efficiently. NMS monitors the network status of DCUs (Data Concentration Unit) and modems. NMS provides functionalities of data collection and analysis. It collects property data of network device, network topology information, communication performance information, fault information, and etc. It analyzes collected data and controls network devices by remote access. AMI NMS collects about 370 MIBs (Mangement Information Bases) using SNMP (Simple Network Management Protocol). This paper introduces main functionalities, designed context, and implemented service screen.

Development of Multi Function Display for Digital Ship (Digital Ship을 위한 다기능 표시장치 개발)

  • Choe, Hang-Soeb;Kim, Jung-Han;Park, Dong-Ho;Rim, Sung-Jeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2855-2857
    • /
    • 2005
  • 디지털 선박(Digital Ship)이란 항해의 안전과 효율적 운행을 위해 항해, 조정, 상태감시 등 선박운행에 대한 전반적인 내용들을 컴퓨터를 통해서 구현하고 위성통신을 통해서 육상에서도 제어할 수 있는 완전 자동화 및 네트워크화 된 시스템을 의미하며 궁극적으로 무인화된 선박을 지향한다. 또한 통한항해시스템이란 선박의 경제적이고 안전한 운항을 위해 전자해도와 레이더를 이용하여 선박의 항로를 계획하고 감시하며 최적 항로 분석, 충돌/좌초방지 및 자동항법시스템과 연계한 자동항해 기능을 수행한다. 본 논문은 디지털 선박을 위하여 항해정보시스템과 항해 장비 통합장치 및 통신서버를 기반으로 한 전자해도와 레이더, 자동항법장치(autopilot) 및 각종 항해센서의 다기능 표시장치의 기능과 인터페이스 방안을 제시하였다.

  • PDF

An Insulation Resistance Measurement of IT network using LabVIEW (LabVIEW를 사용한 IT접지방식 배전계통의 활선절연저항 측정)

  • Kim, Yong-Jung;Kim, Doohwan;Kim, Hyosung
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.228-229
    • /
    • 2013
  • 원자력발전소, 병원 및 철도와 같이 지속적인 전력공급이 필요한 시설에서는 IT접지시스템의 적용이 활발해지고 있다. 또한 자가발전을 통한 DC배전계통에서 IT접지시스템이 사용될 것으로 예측되고 있다. 이러한 IT접지시스템은 전력선의 어느 쪽도 접지하지 않으며, 장비의 외함 만을 접지함으로써 전력선의 어느 한쪽이 접지되는 사고를 당하더라도 계통의 운전을 정지시키지 않고 고장부위를 찾을 수 있는 시간적 여유가 있으므로, 계통의 연속적인 운전을 확보할 수 있다. 그러나 이러한 접지의 장점을 얻기 위해서는 계통의 운전 중에 전력선의 상태를 지속적으로 감시할 필요가 있다. 본 연구에서는 사용자의 활용도가 높은 LabVIEW 소프트웨어를 이용하여 절연저항을 모니터링 함으로써 전력선의 절연상태를 지속적으로 감시하는 활선절연저항측정기를 개발한다.

  • PDF

디젤발전기 엔진 상태신호 측정 및 분석 사례

  • Choe, Gwang-Hui;Lee, Sang-Guk;Lee, Byeong-O
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.745-745
    • /
    • 2012
  • 원자력발전소에서 비상디젤발전기는 노심의 안전성을 지키는 매우 중요한 역할을 담당하고 있다. 이를 위해 디젤발전기는 신뢰성능 높게 유지하도록 규제요건이 마련되어 있다. 디젤발전기의 엔진 상태를 주기적으로 감시하고 평가하기 위해서는 엔진 상태 신호 분석 기술이 필요하다. 엔진 상태 신호 분석에는 연소분석과 진동 및 초음파 측정 및 분석기술이 중요한 비중을 차지한다. 연소 분석은 디젤 엔진의 개별 실린더에 대한 연소 성능에 대한 정보를 제공한다. 진동 및 초음파 분석은 이벤트 타이밍과 기계적 상태에 대한 정보를 알려준다. 이들 신호는 정상적인 부하로 운전하는 디젤엔진의 가동에 영향을 미치지 않고 수집할 수 있다. 엔진 상태 신호 분석을 이용하는 주요 동기는 전통적으로 장비 제작자의 권고에 따라 수행되는 분해-검사 유지 보수 프로그램을 일부 대체하고 예측정비를 통해 신뢰도를 유지하기 위함이다. 상태 진단정비는 엔진 상태 신호분석을 주로 이용하여 엔진의 신뢰도와 이용률을 증가시킬 수 있다. 본 논문에서는 국내외서 경험한 엔진상태신호 측정 및 분석 사례를 기술하였다.

  • PDF

Design and materialization of remote monitoring integrate mod for efficient TCS(Toll Collection System) maintenance (요금수납시스템의 효율적인 유지관리를 위한 원격모니터링 통합모델 설계 및 구현)

  • Park, Dong-Yeon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2007.05a
    • /
    • pp.531-534
    • /
    • 2007
  • 원격모니터링 통합모델은 고속도로나 유료도로의 영업소 요금수납 체계의 하부시스템 (요금수납시스템, ETCS시스템, 위반차량촬영시스템, 축중시스템)의 구성 및 장애 현황을 감시하고, 장애 발생에 대한 장애처리 체계를 수행하는 모델이다. 본 논문에서는 실시간 장애감시, 효율적 WorkFlow 구성 및 차별화된 정보를 제공하기 위해서 감시 S/W 엔진과 DBMS(Database Managemnet System) 기반의 C/S (Client /Server)시스템을 구성하고 WEB기반의 환경을 설계한다. 본 통합모델을 구현함으로써 체계적인 구성관리/장애관리를 통한 효율적인 유지관리 업무가 가능하며, 현장 장비의 상태 파악이 조기에 용이하여 장애 시간을 최소화 할 수 있다. 또한 Data의 지식 DB화를 통하여 유사 장애에 대한 조치가 용이하다.

The development of F/A system for extractor (사출기용 F/A system 개발)

  • 이범근;송호정;우경환;이천희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1416-1419
    • /
    • 1996
  • 현재 많은 공장에서 사용중인 사출기나 프레스를 중앙 집중식 제어를 위한 다양한 시도가 있었다. 이러한 시도는 많은 공장 자동화와 이를 기본으로 한 생산관리 시스템을 구축함으로서 제품의 품질을 향상시킬수 있을 뿐만 아니라 장비의 오동작을 중앙에서 감시, 감독하여 장비의 효율을 최대화함으로 생산성을 증대하여 기업의 이윤을 최대화 할수 있다는 장점이 있다. 그러나 공장 자동화의 단계는 초기 단계로 여러가지 문제점을 안고 있으며 현 상태의 시스템으로 위의 여러가지 장점을 얻기에는 어려운 실정에 있으며 그 시스템의 운영에도 많은 문제점이 발견되어 운영 불가능 상태로 방치된 이 시점에서 이러한 문제점을 분석하여 최대한으로 현재 개발된 시스템의 오류를 수정 및 보완하여 효과적인 공장 자동화를 위한 시스템을 완성함으로서 생산의 향상과 기업의 원활한 생산 활동을 지원하고자 한다.

  • PDF

Development of Equipment Measuring Insulation Resistance of High-Power Cables in Operation at Power Station (발전소에서 운전 중인 고전력 케이블의 절연저항의 변화를 감시하는 장치의 개발)

  • Um, Kee-Hong;Kim, Bo-Kyeong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.159-164
    • /
    • 2016
  • In or to generate high electric power in increasing demand, power station should operate facilities to meet requirement. The scale of electric power equipment is increasing in both size and complexity. With unexpected accidents at power facilities or power stations happening, substantial socioeconomic losses in an industrial society is caused. A major cause of unexpected accidents is deterioration of dielectrics, isolating two conductors electrically. In order to detect the deterioration processes of power cables, the operation status of power cables should be monitored on a regular basis. We have invented and installed equipment at Korea Western Power Co., Ltd., located in Taean, in order to predict and prevent the deterioration status of dielectrics destruction of power cables. The main line in Y-connection to the secondary coils of transformer delivers electric power to the external devices. The equipment we developed is the one measuring insulation resistance of cables operation in on/off status with respect to the main line. We present the equipment in terms of operation and configuration of hardware side.

Relationship Between Humidity and Insulation Status of XLPE 6.6kV Cables for the Load of Electric Turbine Generator (터빈 발전기 부하용 XLPE 6.6kV 케이블의 절연층 절연상태와 습도의 상관관계)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.5
    • /
    • pp.185-190
    • /
    • 2016
  • The high-power 6.6 kV XLPE (or CV) cables at Korean electric power stations have been in operation for the last 40 years. Most of the XLPE cables starts deteriorating in 6-8 years from the operating instant of time, some cables may be breakdown at any moment even though they were installed in recent years, causing, huge socioeconomic losses. In order to prevent unexpected cable accident, the operating status of power cables should be monitored in regularly, timely bases. We have invented a device in order to systematically monitor and prevent an abrupt accidents of high-power cables in operation at power station. It has been installed at Korean Western Power Co. Ltd. at Taean, and operating normally for the last 4 years. In this paper, we introduce the functions and operating principles of the measuring device, and present the relationship between humidity and insulation status of XLPE cables for the load of electric turbine generator.

A Study on Development and Diagnosis Factors of On-Line DC Leakage Current System for Junctions of High-Voltage Cables in Operation at Thermoelectric Power Station (화력 발전소 고전압 케이블 접속재의 On-Line 직류 누설 전류 시스템 개발과 진단 Factor에 관한 연구)

  • Park, Sung-Hee;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.187-193
    • /
    • 2018
  • There has been a gradual increase in the demand for the electric power in Korea. In order to meet the demand, power station should have technical functions with increased effectiveness. When accident happens in electric machinery at power stations, huge amount of economic losses and mulfunction of equipments occur. One of the accidents is a deteriorated cables operating power stations. In order to prevent cable accident in advance, we should monitor the insulation status of the cable. Cable accidents are resulting from the junctions. We have developed and installed a device in order to identify the status of junction part of power cable at Korea Western Power Co., Ltd.. We performed an accurate diagnosis for the stable utilization of junctions where the accidents occurs most frequently, and to increase the reliability. In this paper, we present the concepts of our device and the method of monitoring diagnosis for the stable use of junctions at cables predicting the life time of cables by analyzing the data obtained by the device. We also present the hardware aspect of the device we have developed.

Analysis of Monitored Insulation Data Using Standard Deviation of Leakage Current Data in High-Power Cables at a Thermoelectric Power Station (화력발전소 고전력 케이블의 누설 전류 측정 데이터의 표준 편차값을 사용한 절연감시 데이터 분석)

  • Kim, Bo-Kyeong;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.245-250
    • /
    • 2017
  • From the instant of installation and operation, power cables start deteriorating. Cable systems can be maintained not only by monitoring the insulation status of the insulation layer and oversheath, but also the insulation status of the terminal and junction in high-voltage power cables. When the cable system (the cable itself and cable junctions combined) deteriorates, fire accidents happen due to dielectric breakdowns. We have invented a device to monitor the deteriorating status of cables, and installed it at Korea Western Power Co. Ltd. located in Taean, Chungcheongnam-do Province. In this paper, we present the results obtained using our device, through analysing and calculating the standard deviation of leakage current from cable insulators attached to the cables. When the standard deviation of analysed leakage current falls below a critical value, a cable system is deemed to be operating safely. But when the standard deviation of analysed leakage current is larger than the critical value, the insulation status of the terminal and junction in the cable system is considered to have seriously deteriorated. The terminal and junction in the relevant system should then be replaced preemptively in order to prevent blackout accidents of cables caused by the suspension of power supply.