• 제목/요약/키워드: 장기 내구성

검색결과 293건 처리시간 0.031초

연성 지오그리드의 내구성 및 장기설계인장강도 평가 (Evaluation of Durability and Long-term Design Tensile Strength of Flexible Geogrids)

  • 조삼덕;김진만;안주환;전한용;조성호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 토목섬유 학술발표회 논문집
    • /
    • pp.21-38
    • /
    • 1999
  • Engineering properties of most polymers used in geosynthetics such as geogrid can be degraded by the chemical reaction (e.g., oxidization, ultraviolet rays, hydrolysis etc.), chemical and mechanical load, microorganism, and so on. In addition, polymer can be damaged by the compaction during construction, and the characteristic of tensile strength of polymer can be changed by the long-term creep effect. In this study, engineering properties of flexible geogrids which are manufactured by weaving/knitting the high-tenacity polymers such as polyester formed in a very open, grid-like configuration, coated with any one of a number of materials (e.g., PVC, latex, etc.), are investigated. Through the analysis of test results, the durability and the long-term design tensile strength of flexible geogrids are evaluated.

  • PDF

층간소음저감재 장기 내구성 평가를 위한 가열시험의 문제점 및 개선방안에 관한 연구 (A study on the improvement method of heat treatment condition for the long-term stability evaluation in the floor impact isolator)

  • 박연준;이찬규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.238-243
    • /
    • 2011
  • This study compared Kd, loss factor and thickness of floor impact isolator by loading/unloading heat treatment with results by continuous loading treatment and checked problem and improvement method of heat treatment condition for the long-term stability evaluation of the floor impact isolation. As the results, it is required the change of heat treatment condition unloading now to loading as actual weigh on the floor impact isolator.

  • PDF

장기폭로실험에 의한 철근콘크리트구조물 보수재료$\cdot$공법의 철근부식특성 평가 (A Study on the Reinforcement Corrosion Evaluation of Repair Material and Method for Reinforced Concrete Structure by Long Term Exposure Experiment)

  • 김영선;이의배;김영덕;조봉석;김재환;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.197-200
    • /
    • 2005
  • In this study, for the establishment of the performance evaluation methods and the quality control standards of durability recovery method, the quantitative exposure data by long term exposure test under the coast is accumulated and analyzed Investigating and evaluating the result of exposure test at 30 month of exposure age under the coastal environment, carbonation and salt damage are not happened at all but the difference in electric potential are found. Therefore, it is considered that the reinforcement corrosion at replacement with repair material are caused by active-passive corrosion macrocells.

  • PDF

결정질 태양전지모듈의 외부 응력에 따른 장기적 내구성 예측 (The Durability Estimation of Crystalline PV Module according to Mechanical Stress)

  • 김경수;강기환;유권종
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.35-36
    • /
    • 2008
  • In this paper, we studied the long term durability estimation for crystalline photovoltaic module while exposing to mechanical stress. Solar cell and PV module have many different kinds of stresses from cell to module fabrication. For this reason, some solar cell shows micro crack that decrease crystallization. In here, we expose artificial mechanical load on surface of PV module. Through this, the periodic external force on PV module might give an negative effect. The further analysis is described in the following paper.

  • PDF

태양전지모듈의 국부적 열특성 변화에 따른 장기적 내구성 및 출력특성 분석 (The analysis on long-term durability and output power characteristics of PV modules by variation on local thermal property)

  • 강기환;김경수;박지홍;유권종;안형근;한득영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.214-215
    • /
    • 2007
  • Int this paper, we studied the analysis on long-term durability and output power characteristics of PV modules by variation on local thermal property. Using 5 modules(80W), we measured the maximum output power change during the test period. And the optical transmittance of glass was compared with PV module's maximum power fluctuation. The external environment change effected contamination on the entire or local surface of module. This caused the local temperature variation of each solar cell on PV module. The specific analysis is shown in the following paper.

  • PDF

페로니켈 슬래그를 사용한 비소성 시멘트 모르타르의 특성 (Properties of Non Sintered Cement Mortar using Ferro Nickel Slag)

  • 윤민식;나형원;형원길
    • 한국건축시공학회지
    • /
    • 제22권6호
    • /
    • pp.641-649
    • /
    • 2022
  • 본 연구는 우리가 사용하고 있는 포틀랜드 시멘트와 골재로 사용되는 천연모래를 산업부산물로 전량 대체하여 비소성 시멘트 모르타르를 개발하고자 하였다. 포틀랜드 시멘트를 대체하기 위해 고로슬래그, 순환유동층 플라이애시, 미분탄 플라이애시를 사용하였으며 천연골재를 페로니켈 슬래그로 대체하였다. 페로니켈슬래그를 적용한 비소성 시멘트 모르타르의 특성을 파악하기 위해 입도 크기를 분류하여 실험을 실시하였다. 플로우 테스트를 통해 유동성 및 작업성을 확인하였으며, 휨 및 압축강도 시험은 재령 3, 7, 28일 실시하였다. 또한 염소이온 침투 시험을 통해 내구성을 파악하였다. 연구 결과, 시멘트와 골재를 산업부산물로 전량 대체한 결합재는 건설재료로 활용 가능성이 높은 것으로 판단된다. 특히 장기강도발현과 내구성확보에 유리한 것으로 확인하였다.

바나듐 레독스 흐름전지용 이온교환막의 수명 예측 (Prediction of Life Time of Ion-exchange Membranes in Vanadium Redox Flow Battery)

  • 조국진;박진수
    • 전기화학회지
    • /
    • 제19권1호
    • /
    • pp.14-20
    • /
    • 2016
  • 바나듐 레독스 흐름 전지는 서로 다른 산화수를 가지는 이온의 산화 환원 반응을 이용하여 전기에너지와 화학에너지를 상호 변환하여 충전 및 방전하는 원리의 에너지 변환 장치로, 구동 중요 요소로는 전극, 전해액, 이온교환막이 있다. 여기서 이온교환막은 산화 환원 반응의 수소이온의 전달 및 전해액을 분리하는 역할을 하며, 이상적인 특징으로는 높은 내산성, 낮은 저항과 높은 수소 전도도와 낮은 바나듐 이온의 투과성과 낮은 가격이다. 최근 이러한 목표에 도달하기 위해서 이온 교환막에 대한 활발한 개발이 이루어지고 있다. 개발된 이온교환막은 여러 물성 평가를 통해 적합막인지 판별하며, 그 평가 중 장기 내구성 평가는 막대한 시간이 걸린다. 이러한 단점을 보완하고자 본 연구에서는 평가 시간이 긴 낮은 전류밀도부터 평가 시간이 짧은 고 전류밀도에서 수행한 단기 실험(총 운전시간 87.5 시간)을 통하여 하나의 식을 만들어 그 수명을 예측하였으며, 실제 장기 내구성 평가(총 예상 운전시간 2,296 시간)를 진행하여 해당 식의 오차율이 5~6%로 적용 타당성을 확인하였다. 그 결과 본 식을 통하여 수명을 예측할 경우 96.2%의 시간을 단축시킬 수 있었다.

4차 암모늄 염을 포함하는 폴리메타크릴레이트 습도센서 (Humidity Sensor of Polymethacrylate with 4th Ammonium Salt)

  • 홍채환;김세훈;남병욱
    • 폴리머
    • /
    • 제31권3호
    • /
    • pp.255-262
    • /
    • 2007
  • 고분자 습도센서 막으로 사용하기 위한 두 가지 타입의 공중합체를 라디칼 중합방식에 의하여 제조하였다. 각각 공중합체는 세 가지의 단량체를 포함하여 제조하였는데, 각 단량체들은 습도 저항성, 막 안정성, 유연성, 임피던스 및 전극 부착력을 증대시키는 효과를 가지도록 하였다. 염 형태의 MDBAB는 제조된 습도 막의 임피던스를 감소시키는 효과를 보였으며 아민과 반응하여 가교 구조를 생성하였다. DAEMA, 4-VP, 및 2-EHA를 사용하여 습도막 제조를 위하여 몇 가지 조성물을 제조하였다. 특정 조성 조건에서 성능 및 장기 내구성 측면에서 우수한 결과를 얻을 수 있었다.

장기자연폭로에 따른 내화뿜칠재의 내화성능에 관한 실험적 검토

  • 김대회;최동호;이세현
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2013년도 추계학술대회 초록집
    • /
    • pp.141-142
    • /
    • 2013
  • 철골건축물은 화재에 취약한 구조로써 내화성능 확보를 위하여 내화피복이 필수적이다. 국내에서 가장 많이 사용되고 있는 철골내화피복재는 내화뿜칠재로 폭 넓게 사용되고 있으나, 기존 제도에서 인정 당시의 내화성능은 확인이 가능하나 시간경과에 따른 내구성저하와 이에 따른 내화성능 저하가 예상된다. 이에 본 연구에서는 실내조건에서 장시간 자연폭로실험을 실시함으로써 내화뿜칠피복재의 시간경과에 따른 내화성능 저하현상을 확인하였다.

  • PDF

저온 소성한 MgO 분말을 혼입한 콘크리트의 내구 특성 (Durability Characteristics of Concrete Containing Lightly Burnt MgO Powder)

  • 최슬우;김주형;이광명;권용길;장봉석
    • 콘크리트학회논문집
    • /
    • 제23권5호
    • /
    • pp.609-615
    • /
    • 2011
  • $850{\sim}1,000^{\circ}C$ 정도의 저온에서 소성된 MgO 분말을 혼입한 MgO 콘크리트는 장기적인 팽창성을 보인다. 이러한 팽창성은 MgO 분말의 느린 수화 반응을 통해 이루어지기 때문에 늦은 재령에서의 수축을 보상하는 특성을 가진다. 하지만 MgO 분말의 혼입은 시멘트의 초결을 지연시키며 응결 시간을 증가시키고, MgO 콘크리트의 공극률과 공극의 크기 분포가 일반 콘크리트와 다르기 때문에 현장 적용을 위해서는 MgO 콘크리트의 역학적 특성뿐만 아니라 다양한 내구 성능에 대한 검토가 필요하다. 이 연구에서는 MgO 콘크리트의 내구 특성을 평가하기 위하여 5% 수준으로 MgO 분말을 혼입한 콘크리트를 재령 56일까지 $20^{\circ}C$에서 수중 양생한 후 탄산화, 동결융해 및 염화물 확산에 대한 실험을 수행하여 MgO 분말을 혼입하지 않은 콘크리트의 내구 특성과 비교하였다. 그 결과 MgO 분말을 혼입한 콘크리트에서 콘크리트의 내구 성능이 다소 향상되는 것을 확인할 수 있었으며, 이는 MgO 분말의 수화 반응에 따른 팽창 효과로 콘크리트의 미세 구조가 치밀해지기 때문으로 사료된다.