• Title/Summary/Keyword: 잔류오염

Search Result 491, Processing Time 0.036 seconds

Applicable Properties of Electrolyzed Acid-Water as Cleaning Water (세정수로서의 전해산화수 적용 특성)

  • 정진웅;정승원;김명호
    • Food Science and Preservation
    • /
    • v.7 no.4
    • /
    • pp.395-402
    • /
    • 2000
  • To enlarge application field of electrolyzed acid-water(EAW) on food industry, the changes of EAW properties by storage conditions and heating were investigatet. It was showed that storing EAW in closed container is mon effective to keep up the oxidation-reduction potentials(ORP), hyperchloride content and pH than stored in opened ones. ORP of EAW stored in closed container could be kept mon than 1 month as 1,150 mV levels. Ruing heating from 2$0^{\circ}C$ to 95$^{\circ}C$, ORP was increased to 1,150 mV levels at 95$^{\circ}C$ after gradual decrease to 5$0^{\circ}C$. Tyrosinase activity was decreased approximately to 26%~35% in EAW having a 950 mV~1,140 mV ORP. Also it was confirmed that EAW has anti-browning effect as sliced apple and potato, and their juices treated with EAW had conspicous difference in their $\Delta$E value. 12 kinds of pesticides such as aldrine, capful diazinon, diedrin, $\alpha$-endosulfan $\beta$-endosulfan, endosulfan sulfate, endrin, $\alpha$-BHC, o,p'-DDT, procymidone, PCNB added in EAW were recovered from ND~73.6% comparing to ones added in distilled water. The recovered amounts of pesticides, procymidone and diazinon in lettuce after soaking in EAW were 1.12 ppm and ND, compared with those of amounts soaked in distilled water were 3.67 ppm and 3.05 ppm respectively. So, it seems that EAW has potentials to promote the degradation of pesticides.

  • PDF

Gas-Liquid Chromatographic Determination of Haloxyfop-R and lts Methyl Ester Residues in Soils and Soybeans (토양과 대두중 Haloxyfop-R 및 Haloxyfop-R-methyl의 기체크로마토그래피를 이용한 잔류분석)

  • Lee, Young-Deuk
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.4
    • /
    • pp.333-340
    • /
    • 1997
  • An analytical method was developed to determine residues of haloxyfop-R and its methyl ester in soils and soybeans using gas-liquid chromatography (GLC) with electron capture detector (ECD). Soil or soybean sample was acidified and extracted with acetone. The extract was then subjected to ion-associated partition to individually separate haloxyfop-R and the neutral methyl ester. One phase containing haloxyfop-R was methylated with $BF_3$/methanol, partitioned to n-hexane and analyzed by GLC/ECD. The other phase containing the methyl ester was further purified by Florisil column chromatography prior to GLC determination. No cross contamination was found between two phases containing each of the acid and methyl ester, thus two compounds can be separately determined as the identical haloxyfop-R-methyl. Overall recoveries of haloxyfop-R from fortified samples averaged 88.2${\pm}$3.9% (n=12) and 88.3${\pm}$4.0% (n=6) for soils and soybeans respectively, and those of haloxyfop-R-methyl showed mean values of 89.2${\pm}$4.0% (n=12) and 85.6${\pm}$5.6% (n=6). Detection limits of both haloxyfop-R and its methyl esterwere 0.005㎎/㎏ and 0.01㎎/㎏ for soil and soybean samples respectively.

  • PDF

Investigation of Nonylphenols Contamination in Solvents and Solid-phase Extraction Cartridge, and its Removal Protocols (정밀분석용 용매 및 SPE의 Nonylphenols 오염평가 및 제거)

  • Park, Jong-Min;Choi, Geun-Hyonng;Kim, Jung-Im;Hong, Su-Myeong;Kwon, Oh-Kyung;Im, Geon-Jae;Kim, Jin-Hyo
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.1
    • /
    • pp.22-27
    • /
    • 2011
  • Nonylphenols are toxic compounds classified as endocrine disruptors. We investigated the nonylphenols clean-up procedures for the contamination control in the quantitative analysis. In this research we analyzed the residual nonylphenols in the solvent and the SPE cartridges. First, at the analysis of HPLC grade solvents (n-hexane, diethyl ether, ethyl acetate and its mixture), diethyl ether was confirmed the residue as 0.963 ${\mu}g/mL$, and we eliminated the contaminant through the distillation with $CaH_2$, Second, at the analysis of SPE cartridges (silica gel and Florisil), all products were showed the residue at 0.046~13.0 ${\mu}g/mL$, but unfortunately the residue in the cartridge were not easily removed with referenced methods in all tested SPE cartridges except in silica gel SPE cartridge with glass ware.

Environmental Pollutants in Streams of Andong District and Insect Immune Biomarker (안동지역 하천의 환경오염물질과 곤충면역 생체지표 분석)

  • Ryoo Keon Sang;Ko Seong-Oon;Cho Sunghwan;Lee Hwasung;Kim Yonggyun
    • Korean journal of applied entomology
    • /
    • v.44 no.2
    • /
    • pp.97-108
    • /
    • 2005
  • Samples of water, soil, and sediment were taken from 10 streams near Andong, Korea in May 2004. To assess the degree of environmental pollution of each stream, chemical pollutants such as total notrogen (T-N), total phosphorus (T-P), chemical oxygen demand (COD), heavy metals, organophosphorus pesticides, organochlorine pesticides, and dioxin-like PCB congeners were analyzed by standard process tests or U.S. EPA methods. In addition, biomarkers originated from insect immune systems of beet armyworm, Spodoptera exigua, were used to analysis of the environmental samples. Except Waya-chun stream showing T-N content of 9.12 mg/L, most streams were contaminated with relatively low levels of overall pollutants in terms of T-N, T-P, and COD, compared to their acceptable environmental levels designated by the Ministry of Environment. Contents of Pb and Cd in samples of each stream were much lower than environmentally permissible levels. However, several times higherconcentrations of Pb and Cd were found in locations at Mi-chun, Kilan-chun, and Hyunha-chun streams, in comparison with other streams. Diazinon, parathion, and phenthoate compounds among organophosphorus pesticides were detected as concentrations of 0.19, 0.40, and $1.13\;{\mu}g/g$, respectively, from soil sample collected in the vicinity of Mi-chun stream. On the other hand, 16 organochlorine pesticides and 12 dioxin-like PCB congeners, known as endocrine disrupting chemicals, selected in this study were not found above the limit of detection. Biomarker analyses using insect immune responses indicated that Waya-chun stream was suspected as exposure to environmental pollutants. Limitation and compensation of both environmental analysis techniques are discussed.

Laboratory Tests for Trichloroethylene (TCE) and Toluene Remediation in Soil Using Soil Vapor Extraction (토양증기추출(Soil Vapor Extraction)을 이용한 토양 내 Trichloroethylene (TCE)과 Toluene정화 실험)

  • 이민희;강현민
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • Column experiments were performed to evaluate the removal efficiency of soil vapor extraction (SVE) iota TCE (trichloroethylene) and toluene in soil. Homogeneous Ottawa sands and real soils collected from contaminated area were used to investigate the effect of soil properties and SVE operation conditions on the removal efficiency. In column teats with two different sizes of Ottawa sand, the maximum effluent TCE concentration in a coarse sand column was 442 mg/L and 337 mg/L in a fine sand column. However, after 20 liter gas flushing, the effluent concentrations were very similar and more than 90% of initial TCE mass were removed from the column. For two real contaminated soil columns, the maximum effluent concentration decreased 50% compared with that in the homogeneous Ottawa coarse sand column, but 99% of initial TCE mass were extracted from the column within 40 liter air flushing, suggesting that SVE is very available to remove volatile NAPLs in the contaminated soil. To investigate the effect of contaminant existing time on the removal efficiency, an Ottawa sand column was left stable for one week after TCE was injected and the gas extraction was applied into the column. Its effluent concentration trend was very similar to those for other Ottawa sand columns except that the residual TCE after the air flushing showed relatively high. Column tests with different water contents were performed and results showed high removal efficiency even in a high water content sand column. Toluene as one of BTEX compounds was used in an Ottawa sand column and a real soil column. Removal trends were similar to those in TCE contaminated columns and more than 98% of initial toluene mass were removed with SVE in both column.

저온 공기 표면 플라즈마 특성과 이를 이용한 화학작용제 제독

  • Jeong, Hui-Su;Seo, Jin-A;Choe, Seung-Gi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.195.2-195.2
    • /
    • 2016
  • 대기압 플라즈마는 공기중에서 방전이 가능하고, 이때 생성되는 활성산소종(ROS)과 활성질소종(RNS)을 적절히 이용하면 살균은 물론 제독이 가능하다. 특히 신경작용제나 수포작용제 등의 화학물질은 박테리아 포자, 세균, 바이러스 등의 생물작용제에 비해 더 많은 에너지와 시간이 요구된다. 현재 군이나 의료 시설에서는 과산화수소를 이용한 제독이나 염소계 표백제 성분으로 구성된 수용성 제독제를 이용하지만, 플라즈마의 경우는 단순히 기체를 방전하여 제독에 이용할 수 있으므로 보다 제독 시스템을 간단하게 구성할 수 있다. 하지만 대기압 방전시 방전전압을 낮추기 위해 헬륨과 알곤등의 기체를 공급하여 사용할 경우 부가적인 시스템의 규모가 커져 활용에 제한이 따른다. 따라서 본 연구에서는 대기중에 존재하는 질소, 산소 등을 이온화시키기 위해 10-25kHz의 주파수에서 4.5kV의 8us 펄스전원을 인가하여 공기 플라즈마를 얻고, 열에 의한 분해효과를 제거하기 위해 플라즈마의 기체온도를 20도로 유지시켰다. 플라즈마의 특성은 방출광 분석법을 이용하여 떨림온도를 계산하였고, 질소와 오존의 농도를 동시에 관찰하였다. 분해된 화학작용제는 기체분석기(Gas Chromatography)를 통해 표준 오염농도대비 잔류한 양을 측정함으로써 제독효율을 계산하였다.

  • PDF

Air Monitoring of Persistent Organic Pollutants Using Passive Air Samplers (Passive Air Sampler를 이용한 잔류성 유기오염물질의 대기 모니터링)

  • Choi, Sung-Deuk;Chang, Yoon-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.5
    • /
    • pp.481-494
    • /
    • 2005
  • The monitoring of persistent organic pollutants (POPs) in the atmosphere is a basis for the study of the fate of POPs in multimedia environments. Recently, passive air samplers (PASs) for POPs have been developed. In this paper, we deal with the principle, properties, and applications of the PAS. The principle of PAS, which has no pump, is physical sorption of semi-volatile organic chemicals on various sorbent materials. The PAS is much smaller than a high-volume air sampler and does not need electricity. These properties of the PAS make it possible to conduct various-scaled environmental monitoring all over the world including the Arctic and Antarctic, but the major disadvantage of PAS is its long sampling periods up to 2 years. To date, four kinds of PAS have been developed: polyurethane foam (PUF), polymer-coated glass (POG), semi-permeable membrane devices (SPMDs), and XAD resin-based PAS. Among them, SPMDs have been commercialized and are most widely used now. Meanwhile, the POPs emitted from China have a large potential to influence the levels and fates of POPs in Korea. Since characteristics of PAS are quite useful to monitor long-range transport of POPs, the use of PAS is highly recommended.

Concentration Distribution of Polychlorinated Biphenyls(PCBs) in Urban Watershed (도심하천유역의 PCBs 농도 분포)

  • Kim, Hyun-Seung;Kim, Il-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.757-766
    • /
    • 2012
  • In this study, we have examined concentration distribution and patterns of PCBs in waters, sediments and soils in an agricultural area of South Korea to investigate the relationship between PCBs sources and concentration levels. The concentration of PCBs in water samples were ranged from lower values below detection limit to 8.25 ug/L and the concentration of PCBs in sediment samples were ranged from lower values below detection limit to 76.67 ug/Kg. The concentration of PCBs in soil samples were ranged from lower values below detection limit to 23.51 ug/Kg. These contamination levels were far below the guideline values suggested for environmental quality assessment. The homologue patterns in samples varied from sample to sample, but isomer patterns were very similar with each other. PCB-138 and PCB-153 were predominant congeners in the soil and sediment, which were similar to the results obtained from previous studies. With these results, the assessment of potential sources of PCBs contamination in the sediments of the Nakdong river basin was performed. The principal components were extracted by Principal Component Analysis(PCA). As the result of PCA, it could be expected that PCBs in samples of this study were more affected by PCB products than combustion processes and mostly affected by already-known sources. The PCBs in the soil and sediment samples were related with commercial PCB products.

The Development of Rapid analytical Method for PCBs in Transformer Oils (변압기 절연유 중 PCBs 신속분석법 개발)

  • Park, Seok-Un;Nam, Chang-Hyun;Park, Hyun-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.136-138
    • /
    • 2008
  • PCBs는 잔류성유기오염물질(POPs) 중 하나로 변압기 절연유 등에 주로 사용되어 왔으나 환경 및 인체유해성이 밝혀짐에 따라 생산 및 사용이 금지된 물질로써 국내에서는 절연유 중 PCBs 분석이 전력산업과 변압기 절연유의 재활용 및 처리 분야에서 매우 중요한 문제로 대두되고 있다. 그러나 현행 폐기물공정시험방법은 분석절차가 까다롭고 고가의 분석비용이 소모되며 고도로 훈련된 분석인력이 필요하다. 이에 본 연구에서는 보다 저렴한 비용으로 신속하게 PCB를 분석할 수 있는 간이 분석법을 개발하고자 하였다. 현행 폐기물공정시험방법에 대한 기술적 검토를 수행하여 복잡한 전처리 절차를 축소하고 번거로운 정성 및 정량작업을 간소화한 결과, 분석비용은 약 1/2, 분석시간은 약 1/3로 줄일 수 있었다. 본 연구에서 개발한 간이 분석법을 현행 공정시험법과 적절히 병행하여 사용 할 경우 폐 변압기의 신속한 분석이 가능하여 분석비용 절감에 따른 큰 경제적 효과가 있을 것으로 예상된다.

  • PDF

A Study on Physical Properties of Recyclables obtained from MSW (재활용(再活用) 대상(對象) 폐자원( 廢資源)의 물리적(物理的) 성상(性狀) 분석(分析)에 관한 연구(硏究))

  • Choi, Woo Zin;Yoon, Kun Duk
    • Resources Recycling
    • /
    • v.21 no.5
    • /
    • pp.72-78
    • /
    • 2012
  • In general, recyclable items are separately discharged from households and then, hand-sorted into different types of valuables at materials recovery facilities (MRF). However, most of residues after hand-sorting are finally end up with landfill and/or incineration due to lack of separation technologies and economical reasons. In the present study, physical properties on recyclable items obtained from an MRF are investigated to improve the recovery of valuable items. The results of physical compositions based on the sizing tests are also presented.