• Title/Summary/Keyword: 자화포화

Search Result 264, Processing Time 0.029 seconds

중성자 조사 및 열처리에 따른 SA508 C1.3강의 자기특성 변화

  • 장기옥;김택수;심철무;지세환;김종오
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.5
    • /
    • pp.249-254
    • /
    • 1998
  • In relation to the application of magnetic method to the evaluation of irradiation damage (embrittlement) changes in the magnetic parameters(hysteresis loop and Barkhausen noise) and Vickers microhardness due to neutron irradiation and heat treatment were measured and compared. In the case of irradiation $(2.3{\times}10^{19}\;n/cm^2,\; E{\ge}1\;Mev,\; 288{\circ}C)$ hysteresis loop measurements show that susceptibility decreases as coercivity increase. Saturation magnetization do not show any change. Barkhausen noise amplitude and Barkhausen noise energy have decreased while Vickers microhardness has increased. For isothermally heat treated condition of irradiated specimen at 470 $^{\circ}C$ and 540 $^{\circ}C$, Barkhausen noise energy has increased while Vickers microhardness has decreased. Results of BNE and Vickers microhardness are reversed to the results on irradiated condition. All these consistent changes in magnetic parameter and Vickers microhardness measurement, which are thought to be resulted from the interaction between irradiation-induced defects and dislocation, and magnetic domain, respectively, show a possibility that magnetic measurement may be used to the evaluation of material degradation and recovery due to neutron irradiation and heat treatment, respectively, if a relevant large database in prepared.

  • PDF

The Magnetic Properties of Polycrystalline Yttrium Iron Garnet by Ferromagnetic Resonance (강자성공명 현상을 이용한 YIG의 자기적 특성 연구)

  • 김기현;이대하;김영호
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.1
    • /
    • pp.7-16
    • /
    • 1999
  • Stoichiometric and nonstoichiometric $Y_{3-x}Fe_{5+x}O_{12})$ polycrystalline samples (x=0.00, 0.05, 0.10, 0.30, -0.05, -0.10, -0.30) were prepared by solid state reaction method. The magnetic properties of the sample were investigated by FMR (ferromagnetic resonance) technique at microwave frequency 5.11 GHz (G-band) and 23.39 GHz (K-band) respectively. The spectroscopic splitting factor g were estimated to be 2.04~2.35 from the derivative absorption lines. As the samples became yttrium $(Y^{3+})$ excess and iron $(Fe^{3+})$ excess, Magnetizations were decreased. But resonance linewidth were increased. To investigate the anisotropy, the angular dependence of resonance magnetic fields were measured. Angular dependence of effective magnetizations were measured by FMR from 77 K to 300 K at K-band microwave frequency (23.39 GHz) and the saturation magnetizations were measured by VSM. The Bloch coefficients B and C were determined by fitting. $M_{eff}(0)$ was obtained by the extrapolation from 80 K. From this result, the spin wave stiffness constant D $(about\; 162~206 \;eV{\AA}^2)$and average square range of exchange interaction $$$(about \;5.84~12.13\;{\AA}^2)$ were determined.

  • PDF

고자장, 저온 환경의 UHV surface magneto-optical Kerr effect 장비 구축 및 Fe/Cr(001)계의 자성특성 연구

  • Park, Yong-Seong;O, Yong-Rok;Hong, Ji-Sang;Kim, Won-Dong;Hwang, Chan-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.400-400
    • /
    • 2010
  • 우리는 기본 진공 $10^{-11}\;Torr$의 UHV surface magneto-optical Kerr effect (SMOKE) 시스템을 quarter-wave plate를 사용하였던 기존의 방식에서 PEM (photo elastic modulator)를 사용하는 방식으로 장비의 기능을 향상시켰다. 기존 quarter-wave plate를 사용하는 방식의 경우 Kerr signal을 구하기 위해 편광자와 검광자를 수직으로 두어 광량을 0으로 만들어야 한다. 그러나 금속의 경우 대부분 가시광선 영역에서 큰 반사율 때문에 측정되는 광량이 편광자와 검광자를 거치면서 넓은 각도 범위에서 최소값을 갖기 때문에 정확한 영점을 잡는 데 한계가 있다. 이러한 단점을 해결하기 위하여 우리는 PEM을 이용한 위상변조방식을 사용하였다. 위상변조 방식은 Kerr signal과 관계된 양을 PEM을 이용하여 50 kH ($1{\omega}$)와 100 kH ($2{\omega}$)의 진동 주파수에 공조시키고 이를 Lock-in-amplifier를 사용하여 탐지하기 때문에 좋은 sensitivity를 얻을 수 있을 뿐 아니라 Kerr ellipticity와 Kerr rotation을 동시에 측정할 수 있다. 자화에 필요한 전자석은 순철로 된 코어를 제작하여 챔버에 부착하였고 10 A에서 최대 7 kOe의 고자장을 얻을 수 있어 포화자화가 큰 물질에 대해서도 필요한 자성영역까지 측정이 가능하게 하였다. 또 저온 측정을 위해 SMOKE 샘플 홀더를 개조하여 액체 질소를 이용하여 100 K 근방의 영역에서 온도를 제어할 수 있도록 저온 장치를 구성하였다. 여기에서 샘플 근처에 위차한 e-beam heater가 장착된 고온 부분과 액체 질소 냉각, 온도감지를 위한 센서, cartridge heater가 장착된 저온 부분을 sapphire plate로 분리하여 저온용 cartridge heater의 파손을 최소화하였다. 이러한 SMOKE 시스템을 구성한 후에 우리는 Fe/Cr(001)시스템의 자성특성에 대해 연구하였다. Fe/Cr 시스템은 Fe/Cr/Fe의 exchange coupling이나 bulk Cr의 복잡한 자성 특성 때문에 주목을 받아왔다. 이 연구에서 우리는 저온 및 상온에서 Cr(001) 단결정 위에 증착된 Fe 박막의 자성 특성을 보고한다.

  • PDF

Characteristics of Saturation and Circulating Current Based on Winding and Iron Core Structure of Grid-connected Transformer in Energy Storage System (ESS 연계용 변압기의 결선방식 및 철심구조에 따른 순환전류와 포화특성에 관한 연구)

  • Tae, Dong-Hyun;Lee, Hu-Dong;Kim, Ji-Myung;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.39-48
    • /
    • 2020
  • Since the fire accident of ESS (energy storage system) occurred at Gochang KEPCO Power Testing Center in August 2017, 29 fire cases with significant property losses have occurred in Korea. Although the cause of fire accidents have not been identified precisely, it should be considered battery and PCS (power conditioning system) as well as unbalance issues in the distribution system. In particular, circulating currents in a neutral line of a grid-connected transformer, which can affect a magnetized current, may have a negative effect on the ESS with unintentional core saturation and surge voltages at the secondary side of the transformer. Therefore, this paper proposes the modeling of the distribution system, which was composed of a substation, grid-connected transformer, and customer loads using PSCAD/EMTDC S/W, to analyze the phenomena of circulating current and surge voltages of the transformer with unbalanced currents in the distribution system. This paper presents a countermeasure for a circulating current with the installation of NGR (neutral grounding resistor) in grid-connected transformer. From the simulation results, it is clear that exceeding the circulating current and surge voltage at the secondary side of the transformer can be one of the causes of fire accidents.

Saturation Characteristic of Iron Core Dependent on Fault Angle in a Flux-Lock Type SFCL (자속구속형 초전도 사고전류제한기의 사고각에 따른 철심의 포화특성)

  • Kim, Jae-Chul;Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.29-34
    • /
    • 2007
  • The fault current limiting characteristics of a flux-lock type superconducting fault current limiter(SFCL) according to fault angles were investigated. From the electrical equivalent circuit with the magnetization branch, the inner magnetic flux of this SFCL due to fault angles was induced and its effect on the limited fault current was analyzed. From the fault current limiting experiments, the exciting current, which described the saturation of the iron core, was calculated and its dependence on the fault angle was analyzed. Before the fault happened, the exciting current did not happen, that it kept zero value. However, after the fault happened, the exciting current flowed and, the exciting current in case of the additive polarity winding showed higher value than for the case of the subtractive polarity winding. The analysis results were compared with the experimental ones, and experimental results agreed with the analysis ones.

Magnetic Properties of Fe-Zr-N Soft Magnetic Thin Films (Fe-Zr-N 연자성 박막의 자기적 성질)

  • 김택수;김종오;이중환;윤선진;김좌연
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.5
    • /
    • pp.317-322
    • /
    • 1996
  • Thin films of Fe-Zr-N were fabricated by rf magnetron reactive sputtering method. The saturation magnetization and coercivity as functions of annealing temperature and partial pressure of nitrogen gas, effective permeability at high frequencies, and thermal stability were investigated. Magnetic softness was exhibited in the composition range of $Fe_{72-78}Zr_{7-10}N_{15-18}$ which was boundary between polycrystalline and amorphous structure. These films exhibited magnetic softness with saturation magentic flux density of 1.55 T and effective permeability of about 3000 at 1 MHz. These films also exhibited thermal stability by sustaining effective permeability of 2500 or above as the temperature was raised to $550^{\circ}C$. It is asswned that good magnetic softness is obtained because grain growth of $\alpha-Fe$ is prohibited due to the precipitation of ZrN nanocrystals. The grain sizes of $\alpha-Fe$ films were $40~50\AA$ and the grain sizes of ZrN nanocrystals were $10~15\AA$.

  • PDF

Investigation of Top-Contact Organic Field Effect Transistors by the Treatment Using the VDP Process on Dielectric

  • Kim, Young-Kwan;Hyung, Gun-Woo;Park, Il-Houng;Seo, Ji-Hoon;Seo, Ji-Hyun;Kim, Woo-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.54-60
    • /
    • 2007
  • 이 논문에서는 게이트 절연막 위에 vapor deposition polymerization(VDP)방법을 사용하여 성막한 유기 점착층을 진공 열증착하여 유기 박막 트랜지스터(OTFTs)소자를 제작할 수 있음을 증명하였다. 우리가 제작한 Staggered-inverted top-contact 구조를 사용한 유기 박막 트랜지스터는 전기적 output 특성이 포화 영역안에서는 포화곡선을, triode 영역에서는 비선형적인 subthreshold를 확실히 볼 수 있음을 발견했다. $0.2{\mu}m$ 두께를 가진 게이트 절연막위에 유기 점착층을 사용한 OTFTs의 장 효과 정공의 이동도와 문턱전압, 그리고 절멸비는 각각, 약 0.4cm2/Vs, -0.8V, 106 이 측정되었다. 게이트 절연막의 점착층으로써 폴리이미드의 성막을 위해, 스핀코팅 방법 대신 VDP 방법을 도입하였다. 폴리이미드 고분자막은 2,2bis(3,4-dicarboxyphenyl)hexafluoropropane dianhydride(6FDA)와 4,4'-oxydianiline(ODA)을 고진공에서 동시에 열 증착 시킨 후, 그리고 $150^{\circ}C$에서 1시간, 다시 $200^{\circ}C$에서 1시간 열처리하여 고분자화된 막을 형성하였다. 그리고 점착층이 OTFTs의 전기적 특성에 주는 영향을 설명하기 위해 비교 연구하였다.

Inrush Current Control of Matching Transformer for Dynamic Voltage Restorer (동적전압보상기를 위한 정합 변압기의 돌입전류 제어)

  • Seo, Il-Dong;Jeon, Hee-Jong;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.340-348
    • /
    • 2006
  • This paper proposes an inrush current control technique of matching transformer for configuration of dynamic voltage restorer(DVR). The DVR system consist of PWM inverter to inject arbitrary voltage, LC low pass filter as harmonic eliminator and matching transformer for isolation. However, the matching transformer has an excess of inrush current by magnetic flux saturation in the core. Due to this inrush current, the rating of matching transformers is double for needed nominal rating for protection of DVR. Therefore, in this paper, the modeling method of magnetic flux saturation is used to analyze a magnitude of inrush current, and additional current controller is used for PWM inverter output regulation. Simulation and experimental results are provided to demonstrate the validity of the proposed control method.

Low-temperature Aqueous Oxidation of Titanomagnetites: Changes in Magnetic Properties of Pseudo-single Domain Particles (위단지구 티탄자철석의 수성 저온산화에 따른 자성변화)

  • 석동우
    • Economic and Environmental Geology
    • /
    • v.34 no.1
    • /
    • pp.147-156
    • /
    • 2001
  • Titanomagnetites, the primary magnetic mineral in submarine basalts, generally has undergone some degree of low temperature oxidation to cation-deficient titanomaghemites. Synthetic analogues of natural titanomaghemite have been prepared by the removal of iron mechanism employing a low-temperature aqueous oxidation method. Along with the low-temperature oxidation of titanomagnetite, magnetic properties of titanomagnetite change sensitively. The results show that as the degree of oxidation increases, the Curie temperature (Tc) increases from $166^{\circ}C$ to $400^{\circ}C$, saturation magnetization (Ms) at room temperature decreases from 126.30 kAlm (25.26 emu/g) to 16.55 kAlrn (3.31 emu/g) monotonously, and coercive force (Hc) and coercivity of remanence (Hcr) increase from 6.13 kAlm (77 Oe) and 23.24 kAlm (292 Oe) to 38.83 kNm (488 Oe) and 47.03 kAlm (591 Oe), respectively. Low field susceptibility (X) decreases from $2023{\times}10^{-6}SI$ to $84{\times}10^{-6}S1$. Based on the results of this study, it is interpreted that the NRM intensity variations of the oceanic crust of presetnt day to 30 Ma is due to the formation of titanomahemites of various degree of oxidation by the low-temperature aqueous oxidation of titanomagnetite, while the magnetic intensity changes of the oceanic crust older than 30 Ma is presumably caused by the combined effect of the formation of titanomaghemites and subsequent inversion of titanomagnemites. DetaileJ causes of the variations of NRM intensity of the oceanic crust may be revealed by systematic studies of the oceanic-floor basalts in the future.

  • PDF

Changes in Mechanical Properties and Magnetic Parameters of Neutron Irradiated Mn-Mo-Ni Low Alloy Steels (중성자에 조사된 Mn-Mo-Ni 저합금강의 기계적 및 자기적 성질 변화)

  • Jang, Gi-Ok;Ji, Se-Hwan;Park, Seung-Sik;Kim, Byeong-Cheol;Kim, Jong-O
    • Korean Journal of Materials Research
    • /
    • v.8 no.11
    • /
    • pp.1020-1025
    • /
    • 1998
  • Irradiation-induced changes in mechanical properties and magnetic parameters were measured and compared to explore possible correlations for Mn-Mo-Ni low alloy steel surveillance specimens which were irradiated to a neutron fluence of $2.3\times10^{19}n/cm^2$(E>1.0MeV) in a typical pressurized water reactor environment at about $288^{\circ}C$. For mechanical property parameters, microvickers hardness, tensile and Charpy impact test were performed and Barkhausen noise amplitude, coercivity, remanence, maximum induction were measured for magnetic parameters. respectively. Results of mechanical property measurements showed an increase in yield and tensile strength, microvickers hardness. 41J indexed $RT_{NDT}$ and a decrease in upper shelf energy irrespective of base and weld metals. However, in the case of tensile properties, the changes in weld metal were negligible compared to the base metal. In the case of magnetic measurements, it is found that magnetic remanence, BN amplitude. BN energy have dropped significantly but coercivity(H,) has increased rapidly after irradiation. In this study. the measurements conducted on surveillance specimens of Mn-Mo-Ni low alloy steel showed that there were strong correlations between mechanical properties and magnetic properties.

  • PDF