• Title/Summary/Keyword: 자체 흡수

Search Result 245, Processing Time 0.027 seconds

Effect of Membrane Material and Absorbent Type on $SO_2$ Removal Using Microporous Hollow-fiber Membrane G-L Contactors (다공성 중공사막 기액 접촉기틀 이용한 $SO_2$ 제거에서 막재질과 흡수제의 영향)

  • Song Hee-Ouel;Kim In-Won;Park Hyun-Hee;Lim Chun-Won;Jo Hang-Dae;Lee Hyung-Keun
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.2 s.31
    • /
    • pp.14-21
    • /
    • 2006
  • An experimental apparatus for the removal of $SO_2$ gas using microporous hollow-fiber membrane G-L contactors was setup. Various performance experiments were carried out with commercial membrane modules and the membrane modules made by KIER. The $SO_2$ removal efficiency was outstanding. When the hollow-fiber membrane was used for the removal of $SO_2$, the selection of absorbers and additives, membrane material, operating conditions of membrane manufacture were significant variables to develop optimal G-L contactors. More experiment works will be done for the development of compact, cost-effective and better G-L contactors.

  • PDF

양자점 원적외선 수광소자 전망

  • 이욱현;강용훈;엄준호;홍성철;최원준;이동한;김문덕;노삼규;이정일
    • The Magazine of the IEIE
    • /
    • v.30 no.5
    • /
    • pp.499-508
    • /
    • 2003
  • 실제 실험에 사용한 대표적인 InAs/GaAs QUDIP에 대해서 detector를 평가하는데 사용하는 responsitity D*뿐만 아니라 이두 값을 좌우하는 phottoconductive gain 양자효율 noise current에 대해 정량적으로 살펴보고 QWIP와 비교해보았다 우선 가장 중요한 것은 QDIP의 온도가 약 10K에서 거의 200K까지 올라가도 responsivity와 D* 모두 온도에 따라 민감하게감소하지 않는다는 사실이다(거의 10배 정도만 감소했음). 이러한 측정결과는 QDIP의 가장 큰 장점인 실온 동작 가능성이 아주 높음을 확인시켜 준다. 참고로, 이미 사용되고 있는 QWIP나 MCT detector는 낮은 온도 영역에서도 온도가 증가함에 따라 responsivity와 D*가 민감하게 감소해서 77K 이상에서는 동작하지 않는다. 두번째로, QWIP는 시료의 표면에 수직 입사되는 IR에 반응하지 않는데, QDIP는 시료의 표면에 수직 입사되는 IR에도 잘 반응함을 확인하였다. 이러한 두 가지 특성은 QDIP가 가질 것이라고 예상되던 QDIP의 가장 큰 장점으로, QDIP가 mid IR이나 far IR detector로서의 전망이 아주 밝음을 보여준다. 저온에서 QDIP의 responsivity는 수 A/W 로, 보통의 QWIP의 responsivity가 수십 mA/W인 것을 고려할 때, 충분히 큰 값이었다. QDIP의 responsivity가 이렇게 큰 이유는 photo-conductive gain이 1000 이상으로 매우 컸기 때문이었다. 반면에, 양자효율은 0.01% 이하로 아주 작았는데, 이것은 흡수 계수 자체보다는 흡수 두께가 작기 때문인 것 같고, 따라서 QDIP의 주기 수를 늘릴 필요가 있음을 알았다. Detector를 평가하는데 가장 중요한 것은 responsivity보다는 D*인데, photoconductive gain과 양자효율의 곱에 비례하는 responsivity는 $\sim$A/W로 충분히 컸지만, 반면에 D*는 $\sim$2E8으로 QWIP에 비해 작았다. 이것은 noise current가 컸기 때문이며 이를 줄이는 것이 중요하다. Noise current의 주된 요인이 dark current에 비례하는 g-r noise이므로, dark current를 줄이는 구조가 필요하다. 대표적인 예가 AlGaAs 같은 additional barrier를 넣어 dark current를 줄이는 방법이다. QDIP의 주기 수를 늘리는 것도 dark current를 줄이는 데 도움이 될 것이다.

  • PDF

Molybdenum 후면전극을 통한 CIGS우선배향성의 제어 및 변환효율에 미치는 영향

  • Yun, Ju-Heon;Kim, Jong-Geun;Yun, Gwan-Hui;Park, Jong-Geuk;Kim, Won-Mok;Baek, Yeong-Jun;Seong, Tae-Yeon;Jeong, Jeung-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.368-368
    • /
    • 2011
  • 최근에 보고된 양질의 고효율Cu(In,Ga)Se2 (CIGS) 태양전지는 CIGS광흡수층이 강한 (220:204) 우선배향성을 갖는 것으로 알려져 있다 [1]. 이러한 CIGS우선배향성은 Se 증착압력, Na농도, 기판온도 및 Mo후면전극의 표면상태에 영향을 받는 것으로 알려져 있지만 정확한 상호관계는 아직 명확히 알려져 있지 않으며, 특히 Mo후면전극의 영향에 대해서는 체계적인 연구결과조차 극히 드문 상황이다 [2]. 본 연구에서는 CIGS 박막의 우선배향성에 대해 Mo후면전극의 미세구조가 미치는 영향 및 이에 따른 cell특성의 변화에 대해서 연구하였다. Mo후면전극의 미세구조는 2 mTorr~16 mTorr까지 증착압력을 변화시켜 제어되었고, CIGS광흡수층은 이렇게 준비된 Mo후면전극상에 3단계 동시증밥법(3-stage process)을 사용하여 형성하였다. XRD를 통한 박막의 우선배향성 평가에서, Mo 증착압력에 대한 IGS I(300)/I(006) 및 CIGS I(220:204)/I(112)의 거동은 Mo 미세구조와 밀접한 관련이 있는 잔류응력(residual stress)의 변화 거동과 상당히 일치함을 보였다. 이에 반해, 높은 압력의 Mo위에 형성된 강한 (220:204) 우선배향성의 CIGS와 bare-glass위에서 형성된 강한 (112) 우선배향성의 CIGS내 Na농도는 서로 유사하였다. 상기의 결과는 Mo미세구조 그 자체가 CIGS 박막 우선배향성의 원인이 됨을 나타낸다. Selenized Mo시편의 XRD분석 및 IGS/Mo 시편의 TEM분석결과을 통해 MoSe2의 반응성이 잔류응력과 비례하는 Mo in-gain 밀도에 의존하는 함을 알 수 있었고, 이러한 MoSe2반응성(reactivity)과 IGS우선배향성 사이에 상당히 밀접한 관련이 있으며 이에 CIGS의 우선배향성이 결정됨을 확인하였다. 마지막으로, Mo변수에 의해 제작된 cell의 특성분석으로부터 cell의 효율이 주로 VOC의 증가에 기인하여 CIGS (220:204) 우선배향성의 정도에 비례하였다.

  • PDF

Study of Retrieving the Aerosol Size Distribution from Aerosol Optical Depths (에어로졸 광학깊이를 이용한 에어로졸 크기분포 추출 연구)

  • Kim, Dukhyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.4
    • /
    • pp.139-148
    • /
    • 2018
  • In this study, aerosol size distributions were retrieved from aerosol optical depth measured over a range of 10 wavelengths from 250 to 1100 nm. The 10 wavelengths were selected where there is no absorption of atmospheric gases. To obtain the solar spectrum, a home-made solar tracking system was developed and calibrated. Using this solar tracking system, total optical depths (TODs) were extracted for the 10 wavelengths using the Langley plot method, and aerosol optical depths (AODs) were obtained after removing the effects of gas absorption and Rayleigh scattering from the TODs. The algorithm for retrieving aerosol size distributions was suggested by assuming a bimodal aerosol size distribution. Aerosol size distributions were retrieved and compared under various arbitrary atmospheric conditions. Finally, we found that our solar tracking spectrometer is useful for retrieving the aerosol size distribution, even though we have little information about the aerosol's refractive index.

Determination of Neutron Absorption Fraction Factor in Manganese Sulfate Bath System (황산망간 용액조 장치의 중성자 흡수분율 보정인자 결정)

  • Lee, Kyung-Ju;Park, Kil-Oung;Hwang, Sun-Tae;Lee, Kun-Jai
    • Nuclear Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.12-17
    • /
    • 1989
  • The correction factor of neutron fraction absorbed by $^{55}$ Mn in the MnSO$_4$ bath was determined for the absolute measurement of neutron emission rate by using the solution circulation-type manganese sulfate bath system. For the determination of this correction factor, I/f, the atomic number desnsity and the effective neutron capture cross section data of Mn, S and impurity elements in the MnSO$_4$ solution were determined. For the atomic number density determination, the MnSO$_4$ solution concentration was determined by using the volumetric EDTA titration and gravimetric method. The impurity contents were analyzed by using the ICP method. For the calculation of effective neutron capture cross sections, a FORTRAN computer program EASCAL was developed in this study. in which Westcott's parameters and Axton's empirical relations are used.

  • PDF

An Optimal Design of the Curtain Airbag System Using the Response Surface Method (반응표면법을 이용한 커튼 에어백 시스템의 최적설계)

  • Yun, Yong-Won;Park, Gyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.1
    • /
    • pp.129-135
    • /
    • 2013
  • There is not enough absorption space in the side of a vehicle so injuries to a passenger are higher compared to frontal impact injuries. For the protection of the passenger in the event of a side impact, vehicle regulations and new car assessment program(NCAP) are implemented all over the world. However, passive safety such as absorption technology of vehicle body itself is limited due to the narrow space of the side part. At the present time, it is well known that a side airbag including a curtain airbag is the most effective system to protect the passenger during a side impact. In this study, optimum design of the curtain airbag is carried out to reduce Head Injury Criterion(HIC) of the passenger. Based on crashworthiness simulation, an orthogonal array is selected based on the defined design variables, the response surfaces are generated from the orthogonal array and optimization is conducted with the surfaces.

The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams (6MV 광자선에서 측정 조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교)

  • 김회남;박성용;서태석;권수일;윤세철
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.87-102
    • /
    • 1997
  • The absolute absorbed dose can be determined according to the measurement conditions; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of 10cm $\times$ 10cm field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations of phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG21 and IAEA protocol. The differences between two protocols are within 1% while the average value of IAEA protocol was 0.5% smaller than TG21 protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within 1%, but individual discrepancies are in the range of - 2.5% to 1.2% depending upon the choice of measurement combination. The largest discrepancy of - 2.5% was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coeficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, it shows that absorbed dose could be affected by phantom material other than water.

  • PDF

Effect of Accelerated Storage on the Microstructure and Water Absorption Characteristics of Korean Adzuki Bean (Vigna angularis L.) Cultivar (팥의 가속화 저장에 따른 미세구조 및 수분흡수 특성)

  • Jieun Kwak;Seon-Min Oh;You-Geun Oh;Yu-Chan Choi;Hyun-Jin Park;Suk-Bo Song;Jeong-Heui Lee;Jeom-Sig Lee
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.68 no.3
    • /
    • pp.167-174
    • /
    • 2023
  • This study investigated the microstructure and water absorption characteristics of the Korean adzuki bean (Vigna angularis L.) cultivar under accelerated storage. The germination rate, acid value, redness (a*), and yellowness (b*) values showed no significant differences after three months of storage compared to pre-storage under low temperatures (4℃). However, a statistically significant difference was observed under accelerated high temperatures (45℃). In particular, after storage for three months, the germination rate and acid value were 0% and 33.63 mg KOH/100g, respectively, under accelerated high temperatures. After storage for three months, the holes, hilum damage, and spaces between the seed coat and cotyledon shortened the time and speed of water absorption under accelerated high temperatures compared to that under low temperatures. Conversely, further research is required to investigate the reason for the low rate of parallel water absorption.

Lysine Fortification of Milssal and Some Observation on the Fortified Product (밀쌀의 라이신 강화(强化) 및 강화(强化)밀쌀의 식품영양학적(食品營養學的) 고찰(考察))

  • Cheigh, Hong-Sik;Pyun, Yoo-Ryang;Kwon, Tai-Wan
    • Korean Journal of Food Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.109-115
    • /
    • 1974
  • Milssal is a polished, partially gelatinized pressed wheat grain and it is being consumed in Korea. This study was conducted to establish 2 practical means of providing needed lysine to the Korean population through fortification of Milssal. The results are summarized as follow: Lysine infusion of Milssal was significantly higher than polished wheat grain and affected by such factors as time and concentration of infusion solution. Cooking characteristics including water-uptake ratio and expanded volume were apparently better than polished wheat. After conducting the series of fortification experiments under actual manufacturing conditions. a reasonable process was chosen. In the developed process. lysine HCl solution was sprayed instead of water to the cleaned and debranned wheat grains during the regular wetting process. There was no differences in appearance and taste of Milssal before and after fortification. Fortification of the protein of Milssal with lysine has been found to bring a significant improvement in the growth rate of rats and the protein efficiency ratio. Stability remained relatively high throughout the storage period(90 days at $10{\sim}20^{\circ}C$ or 30 days at $37^{\circ}C$).

  • PDF

Effects of Acidification on Physical and Organoleptic Properties of Soybeans (산절임이 콩의 물리적, 관능적 특성에 미치는 영향)

  • 여경은;최희숙;김동원;김주숙;김우정
    • The Korean Journal of Food And Nutrition
    • /
    • v.16 no.4
    • /
    • pp.410-416
    • /
    • 2003
  • Three varieties of soybean were acidified by soaking in two kinds of vinegar which were persimmon vinegar and brewed vinegar. Chemical properties of soaking solution and physical and organoleptic properties of soybean during soaking at room temperature for 8 days were studied. The soybeans were acidified in vinegar solution at room temperature for 8 days. The results showed that soybean weight was rapidly increased until first two days and then gradually increased thereafter. Increase in total acidity and sugar concentration and decrease in pH of vinegar solution were also measured during initial soaking stage. The changes in pH and acidity were more significant in brewed vinegar than those in persimmon vinegar, The L values of persimmon vinegar solution after soaking the soybean were relatively lower than that of brewed vinegar. The a values of the vinegar solution used for black beans were increased while that of the vinegar solution used for white beans were decreased, The flavor and texture of acidified bean in persimmon vinegar were more soft and less benny than those acidified in vinegar. However sourness of the acidified beans in persimmon vinegar was much softer higher to those values of brewed vinegar.