• Title/Summary/Keyword: 자연증발

Search Result 182, Processing Time 0.03 seconds

Assessment of Drought Severity over South Korea using Standardized Precipitation Evapo-transpiration Index (SPEI) (표준강수 증발산지수(SPEI)를 이용한 남한지역의 가뭄심도 평가)

  • Kim, Byung-Sik;Sung, Jang-Hyun;Kang, Hyun-Suk;Cho, Chun-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.9
    • /
    • pp.887-900
    • /
    • 2012
  • Drought is a non-negligible disaster of nature and it is mainly caused by rainfall shortage for a long time though there are many definitions of drought. 'Standard Precipitation Index' (SPI) that is widely used to express the level of meteorological drought intensity has a limit of not being able to consider the hydrological changes such as rainfall and evapotranspiration caused by climate change, because it does not consider the temperature-related variables other than the precipitation. Recently, however, 'Standardized Precipitation Evapotranspiration Index' (SPEI), a drought index of new concept which is similar to SPI but can reflect the effect of temperature variability as well as the rainfall change caused by climate variation, was developed. In this study, the changes of drought occurrence in South Korea were analyzed by applying SPEI for meteorological data (1973~2011) of 60 climate observatories under Korea Meteorological Administration (KMA). As the result of application, both of SPI and SPEI showed the trend of deepening drought in spring and winter and mitigating drought in summer for the entire nation, with SPI showing greater drought intensity than SPI. Also, SPI and SPEI with 12 months of duration showed that severe droughts with low frequency of around 6 years are generally being repeated.

A Research on the Conception Change Process of Secondary School Chemistry Major Teachers Related to the Evaporation Phenomena in the Air (대기 중의 증발 현상에 대한 중등학교 화학전공 교사들의 개념 변화 과정에 대한 연구)

  • Yang, Gee-Chang;Paik, Seoung-Hey
    • Journal of the Korean Chemical Society
    • /
    • v.52 no.1
    • /
    • pp.84-95
    • /
    • 2008
  • In this study, preconceptions held by chemistry major secondary school science teachers were searched in relation to explanations of water evaporation phenomena with phase equilibrium diagrams. 25 chemistry major science teachers were selected to complete questionnaires developed in this study and 6 among of them were selected to participate in follow-up interviews. Among these, 10 participants were selected for an evaluation of the change of their preconceptions through lessons developed in this study. From the results, it was found that many teachers believed that the phase equilibrium diagram could not explain water evaporation phenomena. They also thought that there was no relation between vapor pressure and the vertical axis of the phase equilibrium diagram. However, after the lessons in earth science, they recognized that the vapor pressure curve of the phase equilibrium diagram could be explained by adopting a saturated vapor curve. Because they had known the process of application the conceptions of saturated situation, nonsaturated situation, process of equilibrium movement in saturated vapor curve. They could understand natural phenomena such as evaporation with the phase equilibrium diagram through a change in their conceptions as guided from science lessons integrating earth science and chemistry.

The Cooling Effect of Fog Cooling System as Affected by Air Exchange Rate in Natural Ventilation Greenhouse (자연환기 온실의 환기회수에 따른 포그냉방시스템의 냉방효과)

  • 김문기;김기성;권혁진
    • Journal of Bio-Environment Control
    • /
    • v.10 no.1
    • /
    • pp.10-14
    • /
    • 2001
  • The cooling effect of a fog cooling system has a close relationship to air flow and relative humidity in the greenhouse. From the VETH chart for cooling design, a cooling efficiency can be improved by means of increasing the air exchange rate and the amount of sprayed water. In the no shading experimental greenhouse by time control, when average air exchange rate was 0.77 times.min$^{-1}$ and spray water amount was 2,009g, inside temperature of the greenhouse was 31$^{\circ}C$ that was almost close to outside temperature and cooling efficiency was 82%. When average air exchange rate was close to temperature of the greenhouse that was no cooling and 70% shading greenhouse environment. When average air exchange rate was 2.59times.min$^{-1}$ , spray water amount was 2,009g and shading rate was 70%, inside relative humidity of the greenhouse was increased was 2,009 g and shading rate was 70%, inside relative humidity of the greenhouse was increased, but temperature was not decreased. When average air exchange rate was 2.33 times.min$^{-1}$ and spray water amount was 2,009g, inside temperature was 31.4 and at that time maximum wind speed at the air inlet of greenhouse was 1.9m.s$^{-1}$ . Since time controller sprayed amount of constant water at a given interval, some of sprayed water remained not to be evaporated, which increased relative humidity and decreased cooling efficiency. Because the shading screen prevented air flow in the greenhouse, it also caused the evaporation efficiency to be decreased. In order to increase cooling efficiency, it was necessary to study on controling by relative humidity and air circulation in the greenhouse.

  • PDF

Simulation Map of Potential Natural Vegetation in the Gayasan National Park using GIS (지리정보시스템을 이용한 가야산국립공원의 잠재자연식생 추정)

  • Kim, Bo-Mook;Yang, Keum-Chul
    • Ecology and Resilient Infrastructure
    • /
    • v.4 no.2
    • /
    • pp.115-121
    • /
    • 2017
  • This study estimated potential natural vegetation in Gayasan National Park through the occurrence probability distribution by using geographic information system (GIS). in Gayasan National Park. Correlation and factor analysis were analyzed to estimate probability distribution. The presence of the Gaya National Park Vegetation survey results showed that 128 communities were distributed. The analyzed relationship between actual vegetation and distribution factors such as elevation, aspect, slope, topographic index, annual mean temperature, warmth index and potential evapotranspiration in Gayasan national park. The probability distribution of potential natural vegetation communities at least 0.3 odds were the advent of Pinus densiflora communities with the highest 55.80%, Quercus mongolica community is 44.05%, 0.09% is Quercus acutissima communities, Quercus variabilis communities are found to be 0.06%. If you want to limit the factors that affect the distribution of vegetation by factors presented in this study, the potential natural vegetation of the Gaya National Park was expected to appear in Quercus mongolica community (43.1%) and Pinus densiflora communities (56.9%).

Heat Transfer in the Passive Containment Cooling System (수동형 격납용기 냉각계통에서의 열전달)

  • Cha, Jong-Hee;Jun, Hyung-Gil;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.281-291
    • /
    • 1995
  • The objective of this work is to obtain the experimental data for the heat transfer processes occurring both on the inside and outside surfaces of containment steel wall with dry and wet outer surface conditions in the passive containment cooling system. The test model represented a 60$^{\circ}$ section of a containment vessel based on the AP 600 geometry. Major linear dimensions of the test model ore reduced tv a factor of ten. To simulate the decay heat a steam generator heated by electricity was placed in the test model. The maximum heat flux was 8.91 kW/$m^2$. Two types of tests were performed. The one was the tort on the natural convection of air without water film flow. The other was the evaporative heat transfer test with the falling water film flow and natural air draft. no test result shooed that the heat transfer capability by the natural convection from the containment to the air without oater film flow was limited at about 1.48 kW/$m^2$ heat flux. It was found that the heat removal capability was remarkably enhanced in the tests with the waster film flow and air draft. The obtained heat transfer data ore compared with the existing correlations.

  • PDF

Improvement of Cooling Efficiency in Greenhouse Fog System Using the Dehumidifier (제습기를 이용한 온실 포그냉방시스템의 효율향상)

  • Nam Sang Woon;Kim Kee Sung;Giacomelli Gene A.
    • Journal of Bio-Environment Control
    • /
    • v.14 no.1
    • /
    • pp.29-37
    • /
    • 2005
  • In order to provide fundamental data on utilization of dehumidifier in greenhouses, a condensing type dehumidifier using ground water as a coolant was developed and tested dehumidification performance. The developed dehumidifier was applied to greenhouse with fog cooling system and effect of dehumidification on improvement of evaporative cooling efficiency was analyzed. Results of the dehumidifier performance test showed that dehumidification using ground water as a coolant was sufficiently possible in fog cooling greenhouse. When the set point temperature of greenhouse cooling was $32^{\circ}C$ and as temperatures of ground water rose from $15^{\circ}C\;to\;18^{\circ}C,\;21^{\circ}C\;and\;24^{\circ}C$, dehumidification rates decreased by $17.7\%,\;35.4\%\;and\;52.8\%$, respectively. As flow rates of ground water reduced to $75\%\;and\;50\%$, dehumidification rates decreased by $12.1\%\;and\;30.5\%$, respectively. Cooling efficiency of greenhouse equipped with fog system was distinctly improved by artificial dehumidification. When the ventilation rate was 0.7 air exchanges per minute, dehumidification rates of the fog cooling greenhouse caused by natural ventilation were 53.9%-74.4% and they rose up to 75.4%-95.9% by operating the dehumidifier. In case of using the ground water of $18^{\circ}C$ and flow rate of design condition, it was analyzed that whole fog spraying water can be dehumidified even if the ventilation rate is 0.36 exchanges per minute. As a utilization of dehumidifier, it is possible to improve cooling efficiency of fog system in naturally ventilated greenhouses.

Changes Quality of Solar Salt According to the Depth of Hea-ju (해주의 깊이에 따른 천일염의 품질 변화)

  • Lee, S.K.;Kim, S.E.;Kim, H.;Kim, W.;Han, J.W.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.97-97
    • /
    • 2017
  • 천일염의 생산공정은 바닷물(나트륨 농도: 2~3%)을 저수지로 유입시킨 바닷물을 농축하는 1차 증발지(난치)와 2차 증발지(누태)로 보내 일반적으로 2주 정도 증발시켜 나트륨 농도 12~15% 소금물을 만든다. 온도가 낮은 겨울철에는 결정지를 거치거나 2차 증발지의 농축시켜 창고(해주)에서 보관 하는 동안 나트륨 농도 25~27%정도로 상승되어 소금 결정을 이루고 채염하여 창고로 운송한다. 보관창고에서 천일염에서 쓴맛을 내는 간수를 제거한 뒤 선별, 건조 및 포장하는 유통하는 단계로 이뤄진다. 천일염의 생산과정 중 해주는 함수를 저장하여 고농도의 함수를 저장하여 불용분 및 이물질을 자연 침전시켜 맑은 함수를 다음 공정으로 이송시켜 천일염 품질향상에 중요한 공정 중에 하나이다. 그러나 일반적인 염전의 해주는 지붕의 복사열로 인하여 저장중인 해수의 대류로 인하여 침전물이 상승되고 이물질이 부유함으로 인하여 품질저하의 원인이 되고 있다. 또한 해주 구조 및 해주 품질에 대한 자료는 전무한 실정이다. 따라서, 본 연구의 목적은 해주의 깊이에 따른 해수의 대류 방지 깊이 및 품질 변화를 측정하여 고품질 천일염 생산공정에 적용하는데 목적이 있다. 해주분석을 위한 염전은 결정지 채염공정을 공유하는 2개지역 3개 염전을 대상으로 하였으며, 무안, 운남 및 만품지역의 3개소를 선정하여 생산방식이 비교적 동일한 염전을 선정하여 조사 및 분석하였다. 해주의 깊이는 1.0, 3.0, 3.5m인 해주의 시료를 채취하여 Calcium, Magnesium, Sulphate, Chloride 의 함량 분석은 Arena 20 XT 자동흡광분석기 (Automated photometric analyzer)을 이용하여 분석을 하였다. 각 염전에서 채취한 해수의 평균 탁도 값은 해주의 깊이가 깊을수록 탁도 값이 낮은 것으로 나타났다. 해수의 색상 "b" 값은 해주 깊이가 깊을수록 낮은 결과를 보였다. Mg 함량은 전반적으로 15,000~40,000 mg/L 범위의 값을 나타냈으며, Sulphate 함량은 약 30,000~65,000 mg/L 범위의 값을 나타났으며, 깊이가 깊을수록 Mg, Sulphate 함량이 낮아지는 결과를 보였으나 Chloride 함량은 뚜렷한 경향을 보이지 않았다. 실험 결과 해주 깊이에 따른 함수의 품질 차이가 발생하는 것을 확인 할 수 있었으며, 해주의 바닥 깊이가 깊을수록 함수의 불용분 침전, 분리에 효율적인 것으로 판단되었다.

  • PDF

Study on the performance characteristics of a new CO2 auto-cascade heat pump system (새로운 CO2 오토 캐스케이드 열펌프 시스템의 성능특성 연구)

  • Yun, Sang-Kook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.191-196
    • /
    • 2017
  • Owing to the harmful environmental effects of HCFC and CFC refrigerants discovered in the late 20th century, the need for environmentally friendly refrigerants such as $CO_2$ in cooling systems has increased. Air-source $CO_2$ heat pumps that utilize ambient heat in cold winter are less efficient because of a higher evaporation temperature, and it is difficult to manufacture the components of the heat pump owing to a super critical pressure of over 130 bar. This research aims to overcome these disadvantages and improve energy efficiency by introducing a new lower-pressure $CO_2$ auto-cascade heat pump system. $CO_2$-R32 zeotropic refrigerants were considered for two-stage expansion and effective cooling heat exchanging system configurations of the new auto-cascade heat pump. The results indicated that the efficiency of the two-stage expansion system was higher than that of the original one-stage expansion system. Furthermore, the two-stage expansion system showed significant performance improvements when the two-stage expansion stage from highest pressure of 70bar, intermediate expansion pressure of 25bar, and final low pressure of 10bar is applied. The COP of the new two-stage auto-cascade system (2.332) was 43.15% higher than that of the present simple auto-cascade system (1.629). Refrigerants having an evaporation temperature of $-10^{\circ}C$ or lower can be obtained that can be easily evaporated in an evaporator even at a low temperature.

Numerical Study on Spontaneous Combustion in Coal Stockpile (저탄장에서의 석탄 자연발화에 관한 수치 해석적 연구)

  • HONG, JINPYO;KIM, JAEKWAN;CHI, JUNHWA;PARK, SUKWOON;SEO, DONGGYUN;LEE, JINHYANG
    • Journal of Hydrogen and New Energy
    • /
    • v.28 no.6
    • /
    • pp.721-728
    • /
    • 2017
  • In this work, an one-dimensional analysis on spontaneous combustion in a coal stockpile was conducted using a commercial software $gPROMS^{(R)}$ based on assumption suggested by Arioy and Akgun. According to them, it is assumed that there is temperature difference between the surface of coal particle and the gas surrounded around the particle, and it is also assumed that the velocity of the gas is constant and thus oxygen is fed to the stockpile with same velocity. The higher temperature zone is formed to the surface of the coal stockpile at the initial phase and it became deepen as time is taken. Finally it was found that the temperature difference between coal particle and the gas was calculated as $57^{\circ}C$ and spontaneous combustion have not been occurred during 6 months since coal was piled in the stock.

Development of a New Heat Exchanger for the Super Cooling (HESC) to Enhance the Performance of the Heat Pump System for the Living Space by the Natural Energy (자연에너지를 이용한 생활공간 냉난방용 열펌프의 성능향상을 위한 과냉 촉진 신개념 열교환기(HESC) 개발)

  • Song, Heon
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.40-48
    • /
    • 2011
  • 과냉 촉진을 위한 새로운 열교환기(HESC)가 생활공간의 냉난방을 위한 공기-물 열펌프의 성능계수 향상을 위해 본 연구에서 개발되었으며 그 효과를 실험적으로 분석하였다. 이 열교환기(HESC)는 여러 단계의 셀과 튜브로 구성되어 있으며, 열펌프 시스템의 응축기와 증발기 사이에 장착되었다. 실험 조건으로, 외기온은 $7^{\circ}C$에서 $-17^{\circ}C$, 입구 물 온도는 $7{\sim}10^{\circ}C$ 그리고 제 2열전달매체로서 물의 질량 유동율은 시간당 100에서 $300{\ell}$로 변화를 주었다. 본 실험에서 이 열교환기가 장착된 열펌프의 압축기에서의 냉매 입 출구 사이의 온도 차이는 열교환기가 장착되지 않은 열펌프보다 $15^{\circ}C$ 높았다. 이에 따라 이 열교환기가 장착된 열펌프 시스템은 외기온 $-10^{\circ}C$에서 COP가 0.8 증가하였다. 따라서 이 공기-물 열펌프 시스템은 최근 한국에서 실용화되고 있는 고비용이 요구되는 지열 열펌프 시스템을 대체하여 생활공간을 위한 냉난방 시스템으로서 중요한 역할을 할 수 있을 것으로 사료된다.