Quality Control to Improve Reliability of Automatic Water Quality Data (수질자동측정망 자료의 신뢰성 제고를 위한 정도관리)

  • Lim, Byung-Jin;Hong, Eun-Young;Kim, Hyun-Ook
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.2
    • /
    • pp.338-344
    • /
    • 2010
  • The automatic water quality monitoring system (AWQMS) have been installed to immediately response to any pollution incident. It also make it possible to conduct the task efficiently regarding water quality control. The purpose of this study is to enhance reliability by securing accuracy of automatic water quality data through quality assessment (QA) for temperature, pH, dissolved oxygen (DO), electric conductivity (EC), total organic carbon (TOC). The result of comparison between manual and automatic data, relative accuracy of general items (temperature, pH, EC, DO) and TOC were mostly satisfied with guideline (i.e. less than 20%). On the other hand, relative accuracy of DO between sampling site and housing site was somewhat against the guideline. The contamination by attaching algae and microorganism in the pipeline is considered as main cause. After backwashing the pipeline, DO concentration was increased up to 53%. Therefore, pipeline management is recognizable as important thing to secure reliability of water quality data.

Operation and Verification of Real-time Discharge Measurement Using UVM in Large River (이동시간차 방식 자동유량측정시설의 대하천 운영 및 검증)

  • Rho, Young-Sin;Park, Hyun-Keun;Kim, Chi-Young;Jung, Sung-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.405-409
    • /
    • 2009
  • 현재 하천의 유량측정을 위해 국내외에서 설치, 운영되고 있는 자동유량측정시설은 대부분 초음파유속계를 이용한 실시간 하천유량측정시스템이다. 이러한 초음파유속계는 도플러 방식 초음파유속계(ADVM)와 이동 시간차 방식 초음파유속계(UVM)로 구분되는데, 한강대교 등에 적용된 ADVM 방식에 비해 UVM 방식은 초음파 도달거리의 특성으로 인해 대부분 중소규모의 하천에 적용되어왔다. 이러한 UVM 방식을 하폭이 넓고 홍수시 수위변화가 심한 대규모하천에 적용하기 위해서는 여러 회선을 다층으로 구성하여 설치할 필요가 있는데, 한강의 여주지점은 16개의 회선을 5개의 층으로 구성하여 측정의 정확도를 높이고 홍수시 수위상승시에도 다양한 회선으로 유속을 측정할 수 있도록 하였다. 본 연구에서는 여주지점에 설치되어 운영 중에 있는 이동 시간차 방식 자동유량측정시설의 운영결과를 검토하고 측정치에 대한 검증을 위해 2008년 1월부터 12월까지의 유량측정결과를 검토하였다. 평 저수시는 유속계와 ADCP 이동보트를 이용한 연속측정결과와 비교하였으며 홍수시에는 봉부자 측정결과와 비교하였다. 기존 실측은 2008년 2월부터 12월까지 저수위 및 중 고수위에 걸쳐 실시하였으며, 프라이스유속계 22회, 이동식 ADCP 6회 그리고 부자를 이용한 방법 6회등, 총 34회가 이루어졌으며, 비교 결과 수위 1.5m 이하의 저 평수기에 평균 5.5%의 오차를 보였으며, 홍수시 검증측정유량과의 비교결과 7.6%의 오차를 보였다.

  • PDF

Development of real-time continuous suspended sediment concentration measurement system using acoustic backscatter of H-ADCP (실시간 부유사농도 측정을 위한 횡방향 초음파도플러유속계의 초음파산란도를 활용한 부유사농도 측정 시스템 개발)

  • Son, Geunsoo;Roh, Youngsin;Kim, Dongsu;Choi, Kwangtae;Chung, Hokun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.23-23
    • /
    • 2022
  • 하천의 유량 및 유사량 자료는 하천에서 발생하는 다양한 문제를 분석하기 위한 기초자료로 지속적인 모니터링을 통한 측정자료의 생산이 필요하다. 따라서, 국내에서는 지속적인 유량 측정을 목적으로 전국의 주요 국가하천을 대상으로 약 62개소에서 H-ADCP를 활용하여 지속적인 유량측정을 수행하고 있다. 이때, H-ADCP는 유량을 측정하기 위한 유속자료와 함께 초음파산란도 자료를 부가적으로 제공하고 있어 초음파산란도를 부유사농도의 지표로 활용하여 지속적인 부유사농도를 측정하기 위한 연구가 수행되고 있으며, 기존에 설치된 자동유량관측소의 H-ADCP를 통해서 실시간의 유량자료와 함께 유사량 자료를 제공할 수 있을 것으로 기대되고 있다. 이에 본 연구에서는 자동유량관측소를 대상으로 과거 유사량 측정을 수행한 5개 지점을 선정하여 초음파산란도를 활용한 부유사농도 측정 기술의 적용성을 검토하였고, 이를 통해 제시한 부유사농도 측정 방법을 통해 실시간 부유사농도 측정 시스템을 개발하였다. 그리고 실시간 부유사농도 측정 시스템의 적용성을 검토하기 위해 나주시(남평교) 자동유량관측소 지점에 시스템을 구축하여 초음파기반의 부유사농도 측정 기술을 통한 실시간 부유사농도 산정 방법에 대한 보완 사항과 개선방향을 도출하고자 하였다.

  • PDF

Development and Application of Real-Time Automatic Discharge Measurement System in Small Stream (실시간 소하천 자동유량계측 시스템 개발 및 적용)

  • Kim, Seojun;Yoon, Byungman;Cheong, Taesung;Im, Yunseong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.82-82
    • /
    • 2019
  • 최근 사물인터넷 등의 IT기술의 발전과 함께 수리 계측 분야에서도 자동 유속 및 유량 측정장비들에 대한 연구와 적용이 활발하게 진행되고 있다. 하지만 최근 개발된 자동 유속 측정 장비들은 설치가 어려울 뿐만 아니라 비용이 많이 들기 때문에 쉽게 적용하기가 어려워 극히 소수의 지점에서만 운영 중에 있으며 전국 2만2,823개소에 달하는 소하천에 적용하기에는 무리가 있다. 이와 같은 문제점들을 해결하기 위해 보다 간편하고 경제적인 유속 측정 방법으로 주목을 받고 있는 방법이 표면영상유속계이다. 표면영상유속계는 일반 동영상 촬영 장비와 분석 소프트웨어만 있으면 유속을 측정할 수 있기 때문에 매우 경제적이고, 비접촉식으로 유속을 측정하기 때문에 흐름에 방해를 주지 않을뿐만 아니라 홍수 시 유속 측정의 위험성을 최소화 할 수 있다는 장점이 있어, 유량과 수위가 급격하게 변하는 국내 소하천의 유량측정에 적절하게 대응할 수 있다는 장점이 있다. 이에 본 연구에서는 기존의 표면영상유속계를 실시간 자동유량계측이 가능하도록 시스템화 하여 개선하였다. CCTV 기반의 실시간 소하천 자동유량계측 시스템의 구성은 CCTV, 초음파수위계, 현장제어함체 및 조명으로 구성되어 있고, 현장제어함체에는 CCTV 영상분석 S/W가 설치되어 있으며, 실시간으로 산정한 유속자료와 초음파수위계로 측정한 수위자료를 이용하여 유량을 자동으로 산정하도록 개발하였다. 또한 울주군에 위치한 중선필천에 설치하여 적용성 여부 및 현장검증을 실시하였으며, 2018년 홍수사상에 대한 유량계측을 실시한 결과 표면영상만으로 소하천의 유속을 매우 짧은 시간에 계측할 수 있어 소하천의 급격한 유량 변화를 매우 안정적으로 계측하여 온전한 홍수 사상을 확보 할 수 있었다. 또한, 현장 계측 인력 없이도 CCTV 영상으로 현장상황을 파악할 수 있어 홍수대응 지원도 가능한 장점이 있음을 확인하였다.

  • PDF

Comparison of Autorefraction and Refraction with iTrace for Elementary School Children (초등학생의 자동안굴절계와 iTrace로 측정한 굴절검사 값의 비교)

  • Kim, Hyojin;Lee, Koon-Ja;Kim, Sam-Yi;Kim, Se-Rom
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.99-104
    • /
    • 2010
  • Purpose: Difference of refraction result from the method of autorefraction and iTrace were investigaged for the children of elementary school in Asan City. In iTrace method. exclusion of accommodation without cycloplegia was used. Methods: Manifest refractive stale of 42 eyes of 12~13 years old were measured using autorefractor and iTrace. Refractions of far (more than 5 m) and ncar (30 cm) vision were measured using iTrace. All data showed that the spherical equivalent were classified as being in the group 1 (-0.50D < ~ < +1.00D) and 2 (below -0.50D) according 10 refractive errors. Results: Mean spherical equivalent using autorefractor and iTrace (far and near vision) were -1.08D, -0.29D and -2.34D, respectively (p<0.01). Compared with the far vision using iTrace, autorefraction was measured the myopia with -0.50D ~ -1.00D in 52.4% of total eyes. Autorefraction also statistical significant were measured a more myopia than the far vision using iTrace in group I and 2. Conclusions: The difference of refractive errors between autorefraction and iTrace, objective refraction were measured with far vision of more than 5 m were -0.79D. Autoreftaction showed statistically decreased refraction errors than iTrace with far vision.

Verification Study on Real-time Automated Discharge Measurement (실시간 자동측정유량의 검증 연구)

  • Roh, Young-Sin;Kim, Dae-Young;Park, Hyun-Geun;Jung, Sung-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.329-333
    • /
    • 2008
  • 본 연구에서는 도플러 방식 초음파유속계(ADVM, Acoustic Doppler Velocity Meter) 및 이동시간차방식 초음파유속계(UVM, Ultrasonic Velocity Meter)의 유량자료 검증을 위해 두 가지 방식이 적용된 한강대교와 여주대교의 2007년 운영성과를 검토하고 측정된 결과분석을 통해 자동유량측정시설의 유량측정자료를 검증하였다. 측정된 유량의 검증을 위해 평 저수시 유속계 측정 및 이동 ADCP법에 의한 연속 유량측정결과와 비교하였으며, 또한 봉부자를 이용한 측정결과와의 비교를 통해 홍수시 측정결과를 검토하였다. 또한 댐방류량, 하수처리장 방류량, 각종 취수량을 이용한 물수지 분석을 통해 자동유량측정에 의해 산정된 유출량과 비교하였다. ADVM 방식이 적용된 한강대교의 조위영향에 따른 수위변화를 고려하여 한 주기에 대한 측정을 수행하여 이를 비교한 결과, 흐름이 정체되는 일부구간의 측정결과를 제외하면 대부분 상대오차가 10% 내외가 발생하는 것으로 나타났다. 또한 월별 물수지 분석을 수행한 결과, 설치초기 시스템 안정화작업으로 인해 결측이 많이 발생한 $3{\sim}4$월을 제외하면 10%내외의 오차가 발생하였으며, 홍수기인 $6{\sim}7$월 사이에는 $1.9{\sim}5.5%$의 상대오차를 보여 자동유량측정시설의 측정결과가 매우 양호한 것으로 나타났다. 여주대교의 UVM 방식의 경우 측정장비의 안정화가 이루어진 5월부터 9월까지의 측정결과는 수위유량관계곡선으로 산정된 유량과 비교하였을 때 10%내외의 상대오차를 보인 것으로 나타났다. 아울러 월별 물수지 분석결과에서도 결측이 많이 발생한 5월의 23.7%의 오차를 제외하면, $5{\sim}10%$내의 오차를 보인 것으로 나타났으며 홍수기인 $6{\sim}8$월의 경우 5%이내의 오차가 발생한 것으로 나타났다.

  • PDF

환경기술코너-방류수 수징 원격감시체계(TMS) 시범운영

  • Lee, Gyeong-Jin;Jo, Jae-Won;Hyeon, Mun-Sik;Gwon, Bong-Gyeong;Choe, Jun-Chang
    • Bulletin of Korea Environmental Preservation Association
    • /
    • v.29 s.367
    • /
    • pp.42-46
    • /
    • 2007
  • 최근 수질환경보전법의 개정법률(안)에 의거하여 폐.하수종말처리장에 수온, pH, 생물학적산소요구량(BOD), 화학적산소요구량(COD), 총질소(TN), 총인(TP) 및 부유물질(SS)의 자동으로 측정할 수 있는 수질자동측정기의 부착이 의무화될 예정에 있다. 그러나, 현재 전국적으로 화학적산소요구량 측정장비와 같이 일부 항목에 대한 자동측정장치는 설치.운영 중인 곳이 많이 있으나, 수질 TMS 설치 규정에 나와 있는 전 항목을 측정할 수 있는 장비가 설치되어 운영하는 곳은 극히 일부에 불과한 실정이다. 따라서, 수온, pH, 화학적산소요구량(COD), 총질소(TN), 총인(TP), 부유물질(SS) 자동측정 장치를 설치하고, 무선통신(CDMA) 방식을 이용하여 '방류수 수질 원격감시체계(TMS) 시범 운영'을 통하여, 측정 장비들에 대한 자료의 정확성, 신뢰성을 파악하여 설치될 장비들에 대한 성능을 사전에 평가하고, 수질 TMS 시스템에 대한 현장 적응 능력 및 안정성을 파악하여 실질적으로 운영되는 시점에 좀 더 정확하고 실용적인 시스템을 적용하고자 한다.

  • PDF

Automatic Measurement of Microbial Growth in Snake-Flask Culture using an Economic and Automated flow injection Analysis Apparatus (경제적인 자동화 FIA 장치를 이용한 진탕플라스크 배양액의 미생물 증식도의 자동측정)

  • 이형춘
    • KSBB Journal
    • /
    • v.19 no.3
    • /
    • pp.241-244
    • /
    • 2004
  • An automated flow injection analysis apparatus manufactured economically was used in the automatic measurement of E. col growth in shake-flask culture of nutrient broth. The detailed measurement of whole growth was possible at intervals of 10 minutes by the automatic measurement system which adopted the sterilized nutrient broth as a carrier solution. Using distilled water as a carrier solution showed less accurate results than nutrient broth.

방류수 수질 원격감시체계'TMS' 시범 운영

  • Lee, Gyeong-Jin;Jo, Jae-Won;Gwon, Bong-Gyeong;Choe, Jun-Chang
    • Environmental engineer
    • /
    • v.23 s.244
    • /
    • pp.56-60
    • /
    • 2006
  • 최근 수질환경보전법의 개정법률(안)에 의거하여 폐 · 하수종말처리장에 수온, pH, 생물학적산소요구량(BOD), 화학적산소요구량(COD), 총질소(TN), 총인(TP) 및 부유물질(SS)의 자동으로 측정할 수 있는 수질 자동측정기의 부착이 의무화될 예정에 있다. 그러나, 현재 전국적으로 화학적산소요구량 측정장비와 같이 일부 항목에 대한 자동측정장치는 설치 · 운영 중인 곳이 많이 있으나, 수질 TMS 설치 규정에 나와 있는 전 항목을 측정할 수 있는 장비가 설치되어 운영하는 곳은 극히 일부에 불과한 실정이다. 따라서, 수온, ph, 화학적 산소요구량(COD), 총질소(TN), 총인(TP), 부유물질(SS) 자동측정 장치를 설치하고, 무선통신(CDMA)방식을 이용하여 ‘방류수 수질 원격감시체계(TMS) 시범 운영'을 통하여, 측정 장비들에 대한 자료의 정확성, 신뢰성을 파악하여 설치된 장비들에 대한 성능을 사전에 평가하고, 수질 TMS 시스템에 대한 현장 적응 능력 및 안정성을 파악하여 실질적으로 운영되는 시점에 좀 더 정확하고 실용적인 시스템의 적용하고자 한다.

  • PDF

A Measurement Algorithm for the Cornea Curvature in Automatic Refracto-Keratometer (자동 시각 굴절력 곡률계의 각막 곡률 측정 알고리즘)

  • Sung, Won;Park, Jong-Won
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10d
    • /
    • pp.517-519
    • /
    • 2002
  • 본 논문은 자동 시각 굴절력 곡률계의 전자 부문에 연동될 곡률 측정 알고리즘을 소개한다. 만약 자동화된 시스템이 광학계로부터 나오는 영상을 이용하여 내부 처리를 거친 후 정확 시각 측정치를 검사자에게 알려줄 수 있다면 잘못 측정되는 측정 횟수를 크게 줄일 수 있을 것이다. 본 연구는 형태학적 필터링(morphological filtering)과 그레이-레벨의 신호 강조(signal enhance) 기술들을 이용하여 자동시각 굴절력 곡률계에 연동될 각막 곡률 측정 알고리즘을 개발하였다. 알고리즘에서는 광학계로부터 도출된 링 모양 광원의 화상을 처리하기 위해서 새로운 방법을 사용하는 대신에 굴절력 측정을 위해서 6개의 점으로 구성된 화상을 처리하는 방식으로 변형 적용시킨다. 이 때 링의 띠를 6개의 덩어리점으로 변형하는 과정만을 제외하면 굴절력 화상을 처리하는 방식과 같게 된다. 이는 알고리즘의 간결화와 측정 시간을 줄이는 효과를 얻게 된다. 그리하여 본 각막 곡률 측정 알고리즘은 정한 측정 값 도출이 어려운 시각 영상에 적용되어 효과적으로 오차를 줄임으로써 보다 효율적인 시각 측정을 가능하게 하였다.

  • PDF