• Title/Summary/Keyword: 자동측정시스템

Search Result 1,047, Processing Time 0.037 seconds

FPGA Implementation of VME System Controller (VME 시스템 제어기의 FPGA 구현)

  • Bae, Sang-Hyun;Lee, Kang-Hyeon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.11
    • /
    • pp.2914-2922
    • /
    • 1997
  • For FA (factory automation) and ATE (automatic test equipment) in the industrial area, the standard bus needs to increase the system performance of multiprocessor environment. VME(versa module european package format) bus is appropriated to the standard bus but has features of small package and low board density. Beside, the density of board and semiconductor have grown to become significant issues that affect development time, project cost and field diagnostics. To fit this trend, in this paper, we composed Revision C.1 (IEEE std. P1014-1987) of the integrated environment for the main function such as arbitration, interrupt and interface between, VMEbus and several control modules Also the designed, VME system controller is implemented on FPGA that can be located even into slot 1. The control and function modules are coded with VHDL mid-fixed description method and then those operations are verified by simulation. As a result of experiment, we confirmed the most important that is the operation of Bus timer about Bus error signal should occur within $56{\mu}m$, and both control and function modules have the reciprocal operation correctly. Thus, the constructed VHDL library will be able to apply the system based VMEbus and ASIC design.

  • PDF

An Study on Effective Maintenance and Operation System of Fiber Optic Lines (효과적인 광선로 유지 보수를 위한 시스템 개발에 관한 연구)

  • Jang, Eun-Sang;Park, Kap-Seok;Kim, Seong-Il;Choi, Sin-Ho;Lee, Byeong-Wook
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.54-57
    • /
    • 1998
  • As the physical layer on telecommunication network is replaced fiber optic lines, it is increased the need of systematic maintenance for fiber optic lines. Korea Telecom has developed FLOMS in order to establish maintenance processes for optical fiber lines. FLOMS has functions which manages optical facilities and tests optical fiber lines automatically. As a resuls, this system can check and/or report a fault. Operator, who is reponsible for management of optical fiber lines, can test the characteristics of optical fiber lines remotely using FLOMS. As interpoerable with Digital Transmission Management System, FLOMS provides efficient management for optical fiber lines. This system improves the work process to find fault location fast, detect the degradation of fiber quality, and make database of optical facilities efficiently.

  • PDF

Continuous improvement plan of manufacturing process through real-time data acquisition (실시간 정보획득을 통한 제조공정의 지속적인 개선 방안 연구)

  • Jo, Sung-Ho;Chang, Tai-Woo;Shin, Ki-Tae;Na, Hong-Bum;Park, Jin-Woo
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.4
    • /
    • pp.75-90
    • /
    • 2009
  • Improvement of productivity and efficient process management need to define the problem of the previous work. If it takes long time to gather necessary information, it becomes difficult to continuously manage processes to satisfy customers' needs and to enhance business efficiency. This paper proposes methods and a context awareness system for decision making to solve problems originated in management of manufacturing process through real-time information acquisition. We implement the context awareness by suggesting decision logics that automatically classify works with acquired information. And we also implement a system for case study which makes workers recognize problems and notifies instructions to them. Consistency between real object and stored data and continuous process monitoring with this system could find inefficient resources or delayed works, resolve them and improve processes efficiency.

C00rdinated Testing between transformer Tap Selection and Inverter Voilage Control in the PV Distributed Generation system (태양광 분산 발전 시스템의 계통연계용 변압기탭 선정과 인버터전압조정 협조시험)

  • Yoon, kap koo;CHO, SeongSoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1098-1099
    • /
    • 2015
  • ${\bullet}$ 시험대상: 영월태양광 4,990kW(998kW ${\times}$ 5호) ${\bullet}$ 13.07.31 연계기술검토의뢰 ${\bullet}$ 13.08.28 한전검토결과: 인근변전소 영월S/S(40MW) 초과로 10.8km 지점의 평창 D/L 평창간 347호 주진S/S에 다음의 보완대책과 연계 권고 ${\cdot}$ 문제점: 적정전압이탈 및 순시전압변동률 유지불가 ${\cdot}$ 연계기준만족을 위해 한전에서 제시한 보완대책 : 계통용량증설(설비보강), 연계용량 감소 및 전용선로 연계 ${\bullet}$ 14.01.09 분산형설치자의 용역사(에이스기술단)에서 송배전용전기설비 이용규정과 연계기준 만족을 위한 보완대책 제안 ${\cdot}$ 태양광발전시스템 인버터 자동전압(역률/무효전력) 조정기능 및 감시설비 구비 ${\cdot}$ 최적 공통연결점 선정: 분산형전원으로 부터 전기적으로 가장 가까운 영월D/L 영월S/S측에 개폐장치설치 하고 주진S/S 측으로 연계 ${\bullet}$ 14.01.29~06.19 한전(전력연구원)의 유효성 검토 ${\cdot}$ 보완대책 기술적 유효(실증시험 시행 후 시행공문 발송 예정) ${\bullet}$ 14.08.08 송배전용전기설비 이용규정 개정에 따른 협의 ${\cdot}$ 변압기 대당 20MW에서 25MW ${\cdot}$ 변전소 전체 60MW에서 75MW까지 허용 ${\cdot}$ 영월 S/S 측 문곡/영월 D/L 연계 공사 협의 ${\bullet}$ 14.10.04 사용전검사, 한전계통연계운전 시작 ${\bullet}$ 인버터 고정역률(99.9~100%) 운전 시험 ${\cdot}$ 14.11.21 22.9kV 계전기(SEL-751) 5대, 15분 간격 자료저장 ${\cdot}$ SEL-751/USB to RS232C/노트북 15분간격 측정(첨부) ${\bullet}$ 14.03.07 인버터 역률 95.0% 조정 15분간격 측정(첨부) ${\bullet}$ 변압기탭 선정과 인버터전압조정협조시험 계획 ${\cdot}$ 변압기탭을 현장에서 상하 1탭씩 변경 ${\cdot}$ 인버터역률을 인버터공급사에서 원격조정 ${\cdot}$ 22.9kV 보호계전기 SEL-751, 15분 간격 측정 ${\cdot}$ 인버터 370V 계전기 K-PAM DG3000/현장감시설비 연계 ${\cdot}$ 15분 간격 측정 저장 ${\cdot}$ 현장감시설비/인터넷 연결 원격측정(첨부예정)

  • PDF

Measurement of Classes Complexity in the Object-Oriented Analysis Phase (객체지향 분석 단계에서의 클래스 복잡도 측정)

  • Kim, Yu-Kyung;Park, Jai-Nyun
    • Journal of KIISE:Software and Applications
    • /
    • v.28 no.10
    • /
    • pp.720-731
    • /
    • 2001
  • Complexity metrics have been developed for the structured paradigm of software development are not suitable for use with the object-oriented(OO) paradigm, because they do not support key object-oriented concepts such as inheritance, polymorphism. message passing and encapsulation. There are many researches on OO software metrics such as program complexity or design metrics. But metrics measuring the complexity of classes at the OO analysis phase are needed because they provide earlier feedback to the development project. and earlier feedback means more effective developing and less costly maintenance. In this paper, we propose the new metrics to measure the complexity of analysis classes which draw out in the analysis based on RUP(Rational Unified Process). By the collaboration complexity, is denoted by CC, we mean the maximum number of the collaborations can be achieved with each of the collaborator and determine the potential complexity. And the interface complexity, is denoted by IC, shows the difficulty related to understand the interface of collaborators each other. We verify theoretically the suggested metrics for Weyuker's nine properties. Moreover, we show the computation results for analysis classes of the system which automatically respond to questions of the user using the text mining technique. As a result of the comparison of CC and CBO and WMC suggested by Chidamber and Kemerer, the class that have highly the proposed metric value maintain the high complexity at the design phase too. And the complexity can be represented by CC and IC more than CBO and WMC. We can expect that our metrics may provide us the earlier feedback and hence possible to predict the efforts, costs and time required to remainder processes. As a result, we expect to develop the cost-effective OO software by reviewing the complexity of analysis classes in the first stage of SDLC(Software Development Life Cycle).

  • PDF

A study on the honeycomb entry and exit counting system for measuring the amount of movement of honeybees inside the beehive (벌통 내부 꿀벌 이동량 측정을 위한 벌집 입·출입 계수 시스템 연구)

  • Kim, Joon Ho;Seo, Hee;Han, Wook;Chung, Wonki
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.857-862
    • /
    • 2021
  • Recently, rapid climate change has had a significant impact on the bee ecosystem. The decrease in the number of bees and the change in the flowering period have a huge impact on the harvesting of beekeepers. Accordingly, attention is focused on smart beekeeping, which introduces IoT technology to beekeeping. According to the characteristics of beekeeping, it is impossible to continuously observe the beehive in the hive with the naked eye, and the condition of the hive is mostly dependent on knowledge from experience. Although a system that can measure partly through sensors such as temperature/humidity change inside the hive and measurement of the amount of CO2 is applied, there is no research on measuring the movement path and amount of movement of bees inside the beehive. Part of the migration of honeybees inside the hive can provide basic information to predict the most important cleavage time in beekeeping. In this study, we propose a device that detects the movement path of bees and measures and records data entering and exiting the hive in real time. The device proposed in this study was developed according to the honeycomb standard of the existing beehive so that beekeeping farms could use it. The development method used a photodetector that can detect the movement of bees to configure 16 movement paths and to detect the movement of bees in real time. If the measured honeybee movement status is utilized, the problem of directly observing the colony with the naked eye in order not to miss the swarming time can be solved.

Study on precision improvement in weight measurement of an egg for the automatic egg sorting system (계란(鷄卵) 자동(自動) 선별기(選別機)의 난중측정(卵重測定) 정밀도(精密度) 향상(向上)에 관(關)한 기초연구(基礎硏究))

  • Kim, K.D.;Bok, J.S.
    • Korean Journal of Agricultural Science
    • /
    • v.27 no.1
    • /
    • pp.48-53
    • /
    • 2000
  • The various errors existing in a weight measurement system in most automatic egg sorting system available in Korean poultry farms have caused a large amount of economic losses to the egg producers. The object of this study was an importance of egg measurement system by changing both the number and the arrangements of load cells to reduce measuring errors. The results obtained were summarized as follow : 1. Four arrangements of load cells were selected as follows : layout I : Conventional one load cell method layout II : One load cell located as egg moving direction layout III : Two load cells located facing each other layout IV : Two load cells located as parallel with egg moving direction 2. The results of egg weight measurement according to four arrangements (Layout I, II, III, IV) showed that the average errors were 1.1218g, 0.5953g, 0.7786g, 0.2793g respectively. This indicated that the Layout IV (measuring by 2 load cells located parallel with the egg moving direction) caused the lowest average error and the best in precision. 3. The average vibration of axis X, y, Z were resulted as $5.1937{\times}10^{-3}G$, $9.3604{\times}10^{-3}G$, and $16.8657{\times}10^{-3}G$ respectively when sorting large sized egg. This indicated that the vibration of axis-Z was relatively higher than those of axis-X, and axis-Y.

  • PDF

Implementation of Greenhouse Environmental Control Systems using Intelligence (지능을 이용한 온실 제어 시스템)

  • Yang, J.;Chung, C.D.;Hong, You-Sik;Ahn, B.I;Hwang, S.I.;Choi, Y.H.
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.49 no.2
    • /
    • pp.29-37
    • /
    • 2012
  • An experiment for an optimized automatic greenhouse environment in a flower farming greenhouse by building a ubiquitous sensor network with various sensors was conducted and the results were evaluated. And various culturing environmental information and data in the greenhouse were collected and analyzed. Then, the greenhouse was designed to maintain the best culturing environment on the basis of existing recommended optimized figures. By measuring the growth of the crops in the greenhouse, A system which controls facilities in the greenhouse to maintain the best culturing environment in accordance with change in the environment was analyzed.Computer simulation result proced that we discovered that controlling the facilities and the artificial light source increased production, enhanced quality, reduced labor and heating cost immensely. The experiment has proved that the u-flower farming system can maximize the income of farm families by sending warning messages to users of this system when weather suddenly changes so that users may cope with such changes and maintain the best culturing environment.

Remote Care Using Medical Bed System Equipped With Body Pressure Sensors (체압 센서를 이용한 의료용 침대의 원격 케어)

  • Jaehyeok Jeung;Sanghyun Bok;Junhee Lim;Bokyung Oh;Youngdae Lee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.1
    • /
    • pp.619-625
    • /
    • 2023
  • In this paper, the remote care of medical beds with multiple body pressure sensors is described. Falling is one of the factors that seriously threaten the safety of patients and harm their health. In this study, a new bed was developed to overcome this. The bed system consists of a keyboard that can operate, a keyboard controller that manages the movement of the keyboard, a sensor that measures body pressure, a sensor controller that transmits and receives sensor values, a main controller that checks it and operates automatically or manually according to the algorithm, and a server that oversees all these information. The bed system checks the patient's location through a sensor and wirelessly alerts the server through the main controller when the patient determines that there is a risk of falling, so that the nurse or nurse can recognize the patient's dangerous condition. The server may receive state data transmitted from the wired/wireless terminal to monitor whether the bed system is operating normally. The controller of the keyboard operates a keyboard-type mechanism and automatically controls the prevention of bedsores connected by body pressure sensors to physically separate the area to which the patient's pressure is applied to prevent bedsores. The main controller checks the presence of the patient's bed and transmits it to the server. In conclusion, the proposed system can smart monitor the user's state and perform remote care.

An Automatic Operating System for Manless Multipurpose in Greenhouse (시설원예의 생력화를 위한 다목적 자동작업장치 개발)

  • 민병로;김웅;이범선;이대원
    • Journal of Bio-Environment Control
    • /
    • v.13 no.3
    • /
    • pp.143-148
    • /
    • 2004
  • The automatic operating system was designed and built to work manless multipurpose in greenhouse. The system proved to be a reliable system for performing multipurpose functions. Its development involved the integration of moving part, height control part, watering part, ventilation part and inhalation part. The moving part was able to be moved it on the rail installed in greenhouse, the height control part controled it up and down by height of the crops, the watering part sprinkled a agricultural medicines on the crops and the ventilation and the inhalation part ventilated and inhaled different thing and vermin which were attached on crops. Based on the results of this study the following conclusions were made: The moving velocity was changed 0.047 - 0.027 m/s by the dial transfer. The velocity within 50 cm from center of the entrance was 0.2 m/s. The watering volume of spray increased as the pressure of spray was high. The difference of spray pressure between 10 kg/$\textrm{cm}^2$ and 15 kg/$\textrm{cm}^2$ was 60 ml, but that of spray pressure between 15 kg/$\textrm{cm}^2$ and 20 kg/$\textrm{cm}^2$ was 20 ml. The average speed of a current of inhalation was 3.64 m/s and the inhalation flux of inhalation was measured 0.044 ㎥/s by using glues seed and styrofoam.