Position Control Technique of Ultrasonic Scanner for an Automated Ultrasonic Testing Using Surface Wave (표면파를 이용한 자동 초음파탐상검사 주사장치의 위치제어 기술)

  • Lee, Jong-Po;Park, Chul-Hoon;Um, Byong-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.1
    • /
    • pp.30-37
    • /
    • 2003
  • In order to replace the manual ultrasonic testing(UT) with an automated UT(AUT), a scanner which enables us to control the positions of a transducer is essential. Encoders have been commonly used to obtain the position information from the conventional scanners controlled by motor. Encoders have various advantages in many aspects. However, if the slip of motor wheel occurs during scanning, various errors are involved in the position accuracy. Thus, the position information of encoders becomes meaningless in case of slip. The reliability of AUT results nay become serious problem. Hence, slip must be avoided, but it can not be completely avoided at present time. In this paper, a new idea that surface wave is used to solve this problem and replace encoders has been proposed. It is shown that this idea can be employed in AUT scanner without encoders. That is, one transducer transmitting surface wave is fixed and the other transducer attached to the scanner receives UT signal. Then, computer calculates the present position of scanner based on the information given by surface wave. Thus, the movement of a scanner can be controlled by the amount of input based on the information obtained.

A Study on the Usefulness of Auto Dispenser and Optimized Dispensing Method (방사성 의약품 자동 분주장치의 유용성 및 최적화된 분주방법에 관한 고찰)

  • Lee, JeoungEun;Kim, Hosung;Ryu, Jaekwang;Jung, Wooyoung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.59-66
    • /
    • 2013
  • Purpose: Recently, there is an increase of the number of hospitals using auto dispenser to reduce occupational radiation exposure when drawing up of the $^{18}F-FDG$ dose (5.18 MBq/kg) in a syringe from the dramatic high activity of $^{18}F-FDG$ multidose vial. The aim of this study is to confirm that using auto dispenser actually reduces the radiation exposure for technologists. Also we analyzed the reproducibility of auto dispenser to find optimized dispensing method for the device. Materials and Methods: We conducted three experiments. Comparison of radiation exposure on chest and hands: The chest and hands exposure dose received by technologists during the injection were measured by electronic personal dosimeter (EPD) and ring TLD respectively. Reproducibility of dispensed volume: We draw up the normal saline into 5 and 2 mL syringe using auto dispenser by changing the volume from 1 to 15 mm for 5 times in the same setting of the volume. The weight of 5 normal saline dispensed from the device at same volume was measured using micro balance and calculated standard deviation and coefficient of variation. Reproducibility of dispensed radioactivity: We dispensed 362.6 $MBq{\pm}10%$ of $^{18}F-FDG$ in 5 and 2 mL syringes from the multidose vial of different specific activity. In the same setting of volume, we repeated dispensing for 4 times and compared standard deviation and coefficient of variation of radioactivity between 5 syringes. Results: There was significant difference in the average of chest exposure dose according to the dispensing methods (P<0.05). Also, when dispensing $^{18}F-FDG$ in manual method, exposure dose was 11.5 times higher in right hand and 4.8 times higher in left hand than in auto method. In the result of reproducibility of dispensed volume, standard deviation and coefficient of variation shows decline as the dispensing volume increases. As a result of reproducibility of dispensed radioactivity, standard deviation and coefficient of variation increases as the specific activity increases. Conclusion: We approved that the occupational radiation exposure dose of technologists were reduced when dispensing $^{18}F-FDG$ using auto dose dispenser. Secondly, using small syringes helps to increase reproducibility of auto dose dispense. And also, if you lower the specific activity of $^{18}F-FDG$ in multidose vial below 915-1,020 MBq/mL, you can use auto dispenser more effectively keeping the coefficient of variation lower than 10%.

  • PDF

A Comparative Study of Production of [68Ga]PSMA-11 with or without Cassette Type Modules (비 카세트 방식과 카세트 방식을 이용한 [68Ga]PSMA-11의 자동 합성 방법 비교)

  • Hyun-Sik, Park;Byeong-Min, Jo;Hyun-Ho, An;Hong-Jin, Lee;Jin-Hyeong, Lee;Gyeong-Jae, Lee;Byung-Chul, Lee;Won-Woo, Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.15-19
    • /
    • 2022
  • Purpose [68Ga]PSMA-11 is needed the high reproducibility, excellent radiochemical yield and purity. In term of radiation safety, the radiation exposure of operator for its production also should be considered. In this work, we performed a comparative study for the fully automated synthesis of [68Ga]PSMA-11 between non-cassette type and cassette type. Materials and Methods Two different type of modules (TRACERlab FX N pro for non-cassette type and BIKBox for cassette type) were used for the automated production of [68Ga]PSMA-11. According to the previously identified elution profile, Only 2.5 ml with high radioactivity was used for the reaction. After adjusting the pH of the reaction solution with HEPES buffer solution, the precursor was added and reacted with at 95 ℃ for 15 minutes. The reaction mixture was separated and purified using a C18 light cartridge. The product was eluted with 50% EtOH/saline solution and diluted with saline. It was completed by sterilizing filter. In the non-cassette type, the aforementioned process must be prepared directly. However, in the cassette method, synthesis was possible simply by installing a kit that was already completed. Results Both total [68Ga]PSMA-11 production time were 25±3(non-cassette type) and 23±3 minutes(cassette type). The radiochemical yield of the non-cassette type(65.5±5.7%) was higher than that of the cassette type(61.6±4.8%) after sterilization filter. The non-cassette type took about 120 minutes of preparation time before synthesis due to washing of synthesizer and reagent preparation. However, since the cassette type does not require washing and reagent preparation, it took about 20 minutes to prepare before synthesis. Both type of synthesizer had a radiochemical high purity(>99%). Conclusion The non-cassette type production of [68Ga]PSMA-11 showed higher radiochemical yield and lower cost than the cassette type. However, The cassette type has an advantage in terms of preparation time, convenience, and equipment maintenance.

Drum Type Auto Seeding System for Automatic Speed Control System (속도 자동 제어 기능을 구비한 드럼식 자동 파종 시스템)

  • Kim, Song-Hyun;Kim, Hyun-Soo;Oh, Chang-Jun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.512-513
    • /
    • 2017
  • In this paper, an automatic sowing system which arranges the seeds gathered using inhaling technique, on the upper part of cells in trays, is developed to improve the sowing efficiency. In the system, the seeds in inhaled into the vacuum drum, then the seeds are exhausted and arranged on the rotating tray, resulting in rapid sowing system. Also, the velocity control algorithm for the conveyor belt transporting tray is developed to compensate the velocity error generated while the belt is carrying the tray. The velocity control algorithm controls the pulses applying to the stepper motor rotating the drum.

  • PDF

Development of the Automated Ultrasonic Flaw Detection System for HWR Nuclear Fuel Cladding Tubes (중수로형 핵연료 피복관의 자동초음파탐상장치 개발)

  • Choi, M.S.;Yang, M.S.;Suh, K.S.
    • Nuclear Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.170-178
    • /
    • 1988
  • An automated ultrasonic flaw detection system was developed for thin-walled and short tubes such as Zircaloy-4 tubes used for cladding heavy-water reactor fuel. The system was based on the two channels immersion pulse-echo technique using 14 MHz shear wave and the specially developed helical scanning technique, in which the tube to be tested is only rotated and the small water tank with spherical focus ultrasonic transducers is translated along the tube length. The optimum angle of incidence of ultrasonic beam was 26 degrees, at which the inside and outside surface defects with the same size and direction could be detected with the same sensitivity. The maximum permissible defects in the Zircaloy-4 tubes, i.e., the longitudinal and circumferential v notches with the length of 0.76mm and 0.38mm, respectively and the depth of 0.04 mm on the inside and outside surface, could be easily detected by the system with the inspection speed of about 1 m/min and the very excellent reproducibility. The ratio of signal to noise was greater than 20 dB for the longitudinal defects and 12 dB for the circumferential defects.

  • PDF

Development of Automatic Ultrasonic Testing Equipment for Pressure-Retaining Studs and Bolts in Nuclear Power Plant (원자력 발전소 STUD BOLT의 자동초음파 주사장치 개발)

  • Suh, D.M.;Park, M.H.;Hong, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.1
    • /
    • pp.106-110
    • /
    • 1989
  • Bolting degradation problems in primary coolant pressure boundary applications have become a major concern in the nuclear industry. In the bolts concerned, the failure mechanism was either corrosion wastage(loss of bolt diameter) or stress-corrosion cracking.(3) Here the manual ultrasonic testing of RPV(Reactor Pressure Vessel) and RCP(Reactor Coolant Pump) stud has been performed. But it is difficult to detect indications because examiner can not exactly control the rotation angle and can not distinguish the indication from signals of bolt. In many cases, the critical sizes of damage depth are very small(1-2 mm order). At critical size, the crack tends to propagatecompletly through the bolt under stress, Resulting in total fracture.(3) Automatic stud scanner for studs(bolts) was developed because the precise measurement of bolt diameter is required in this circumstance. By use of this scanner, the rotation angle of probe was exactly controlled and the exposure time of radiations was reduced.

  • PDF

Surface Measurement of Microstructures Using Optical Pick-up Based Scanner (광픽업 스캔 장치를 이용한 미소 구조물의 표면 측정)

  • Kim, Jae-Hyun;Park, Jung-Yul;Lee, Seung-Yop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.73-76
    • /
    • 2010
  • The issue of inspection and characterization of microstructures has emerged as a major consideration in design, fabrication, and detection of MEMS devices. However, the conventional measurement techniques, including scanning electron microscopy (SEM) imaging, atomic force microscopy (AFM) scanning, and mechanical surface profiler, require often destructive process or may be difficult to measure with a wafer scale. In this paper, we characterize the surface profiles of microstructures using an optical scanner based on a DVD pick-up module. Scanning images of the microstructures are successfully generated using the intensity of reflected light from different depths of the surface profiles, based on the focus error signal (FES) from photodiodes. It is shown that the proposed optical scanner can be used as an alternative measurement system with high performance and low cost, compared to conventional measurement techniques.

Quality Control of Residual Solvents in $[^{18}F]$FDG Preparations by Gas Chromatography (기체 크로마토그래피를 이용한 $[^{18}F]$FDG 주사액 중의 잔류 용매의 정도관리)

  • Lee, Hak-Jeong;Jeong, Jae-Min;Lee, Yun-Sang;Kim, Hyung-Woo;Chang, Young-Soo;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.6
    • /
    • pp.566-569
    • /
    • 2007
  • Purpose: Analysis of volatile organic solvents in 2-deoxy-2-$[^{18}F]$ fluoro-D-glucose ($[^{18}F]$FDG) preparations was performed by gas chromatography (GC), in accordance with USP. Materials and Methods: Analyses were carried out on a Hewlett-Packard 6890 gas chromatography equipped with an FID. Results: We determined the amounts of ethanol and acetonitrile on every batch of our routine $[^{18}F]$FDG preparations, ranging between 5000 ppm and 100 ppm. In our routine preparation of $[^{18}F]$FDG, the amount of acetonitrile and ethanol in the final product were well below the maximum allowable limit described in the USP. Conclusion: Our $[^{18}F]$FDG preparations were in accordance with the suggested USP maximum allowable levels of the quality control analysis of volatile organic compounds.

Development of the Automated Ultrasonic Testing System for Inspection of the flaw in the Socket Weldment (소켓 용접부 결함 검사용 초음파 자동 검사 장비 개발)

  • Lee, Jeong-Ki;Park, Moon-Ho;Park, Ki-Sung;Lee, Jae-Ho;Lim, Sung-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.275-281
    • /
    • 2004
  • Socket weldment used to change the flow direction of fluid nay have flaws such as lack of fusion and cracks. Liquid penetrant testing or Radiography testing have been applied as NDT methods for flaw detection of the socket weldment. But it is difficult to detect the flaw inside of the socket weldment with these methods. In order to inspect the flaws inside the socket weldment, a ultrasonic testing method is established and a ultrasonic transducer and automated ultrasonic testing system are developed for the inspection. The automated ultrasonic testing system is based on the portable personal computer and operated by the program based Windows 98 or 2000. The system has a pulser/receiver, 100MHz high speed A/D board, and basic functions of ultrasonic flaw detector using the program. For the automated testing, motion controller board of ISA interface type is developed to control the 4-axis scanner and a real time iC-scan image of the automated testing is displayed on the monitor. A flaws with the size of less than 1mm in depth are evaluated smaller than its actual site in the testing, but the flaws larger than 1mm appear larger than its actual size on the contrary. This tendency is shown to be increasing as the flaw size increases. h reliable and objective testing results are obtained with the developed system, so that it is expected that it can contribute to safety management and detection of repair position of pipe lines of nuclear power plants and chemical plants.

Optimization of Automated Solid Phase Extraction-based Synthesis of [18F]Fluorocholine (고체상 추출법을 기반으로 한 [18F]Fluorocholine 합성법의 최적화 연구)

  • Jun Young PARK;Jeongmin SON;Won Jun KANG
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.4
    • /
    • pp.261-268
    • /
    • 2023
  • [18F]Fluorocholine is a radiopharmaceutical used non-invasively in positron emission tomography to diagnose parathyroid adenoma, prostate cancer, and hepatocellular carcinoma by evaluating the choline metabolism. In this study, a radiolabeling method for [18F]fluorocholine was optimized using a solid phase extraction (SPE) cartridge. [18F]Fluorocholine was labeled in two steps using an automated synthesizer. In the first step, dibromomethane was reacted with [18F]KF/K2.2.2/K2CO3 to obtain the intermediate [18F]fluorobromomethane. In the second step, [18F]fluorobromomethane was passed through a Sep-Pak Silica SPE cartridge to remove the impurities and then reacted with N,N-dimethylaminoethanol (DMAE) in a Sep-Pak C18 SPE cartridge to label [18F]fluorocholine. The reaction conditions of [18F]fluorocholine were optimized. The synthesis yield was confirmed according to the number of silica cartridges and DMAE concentration. No statistically significant difference in the synthesis yield of [18F]fluorocholine was observed when using four or three silica cartridges (P>0.05). The labeling yield was 11.5±0.5% (N=4) when DMAE was used as its original solution. On the other hand, when diluted to 10% with dimethyl sulfoxide, the radiochemical yield increased significantly to 30.1±5.2% (N=20). In conclusion, [18F]Fluorocholine for clinical use can be synthesized stably in high yield by applying an optimized synthesis method.