• Title/Summary/Keyword: 자동인지

Search Result 20,413, Processing Time 0.052 seconds

A Template-based Interactive University Timetabling Support System (템플릿 기반의 상호대화형 전공강의시간표 작성지원시스템)

  • Chang, Yong-Sik;Jeong, Ye-Won
    • Journal of Intelligence and Information Systems
    • /
    • v.16 no.3
    • /
    • pp.121-145
    • /
    • 2010
  • University timetabling depending on the educational environments of universities is an NP-hard problem that the amount of computation required to find solutions increases exponentially with the problem size. For many years, there have been lots of studies on university timetabling from the necessity of automatic timetable generation for students' convenience and effective lesson, and for the effective allocation of subjects, lecturers, and classrooms. Timetables are classified into a course timetable and an examination timetable. This study focuses on the former. In general, a course timetable for liberal arts is scheduled by the office of academic affairs and a course timetable for major subjects is scheduled by each department of a university. We found several problems from the analysis of current course timetabling in departments. First, it is time-consuming and inefficient for each department to do the routine and repetitive timetabling work manually. Second, many classes are concentrated into several time slots in a timetable. This tendency decreases the effectiveness of students' classes. Third, several major subjects might overlap some required subjects in liberal arts at the same time slots in the timetable. In this case, it is required that students should choose only one from the overlapped subjects. Fourth, many subjects are lectured by same lecturers every year and most of lecturers prefer the same time slots for the subjects compared with last year. This means that it will be helpful if departments reuse the previous timetables. To solve such problems and support the effective course timetabling in each department, this study proposes a university timetabling support system based on two phases. In the first phase, each department generates a timetable template from the most similar timetable case, which is based on case-based reasoning. In the second phase, the department schedules a timetable with the help of interactive user interface under the timetabling criteria, which is based on rule-based approach. This study provides the illustrations of Hanshin University. We classified timetabling criteria into intrinsic and extrinsic criteria. In intrinsic criteria, there are three criteria related to lecturer, class, and classroom which are all hard constraints. In extrinsic criteria, there are four criteria related to 'the numbers of lesson hours' by the lecturer, 'prohibition of lecture allocation to specific day-hours' for committee members, 'the number of subjects in the same day-hour,' and 'the use of common classrooms.' In 'the numbers of lesson hours' by the lecturer, there are three kinds of criteria : 'minimum number of lesson hours per week,' 'maximum number of lesson hours per week,' 'maximum number of lesson hours per day.' Extrinsic criteria are also all hard constraints except for 'minimum number of lesson hours per week' considered as a soft constraint. In addition, we proposed two indices for measuring similarities between subjects of current semester and subjects of the previous timetables, and for evaluating distribution degrees of a scheduled timetable. Similarity is measured by comparison of two attributes-subject name and its lecturer-between current semester and a previous semester. The index of distribution degree, based on information entropy, indicates a distribution of subjects in the timetable. To show this study's viability, we implemented a prototype system and performed experiments with the real data of Hanshin University. Average similarity from the most similar cases of all departments was estimated as 41.72%. It means that a timetable template generated from the most similar case will be helpful. Through sensitivity analysis, the result shows that distribution degree will increase if we set 'the number of subjects in the same day-hour' to more than 90%.

Development of Convertor supporting Multi-languages for Mobile Network (무선전용 다중 언어의 번역을 지원하는 변환기의 구현)

  • Choe, Ji-Won;Kim, Gi-Cheon
    • The KIPS Transactions:PartC
    • /
    • v.9C no.2
    • /
    • pp.293-296
    • /
    • 2002
  • UP Link is One of the commercial product which converts HTML to HDML convertor in order to show the internet www contents in the mobile environments. When UP browser accesses HTML pages, the agent in the UP Link controls the converter to change the HTML to the HDML, I-Mode, which is developed by NTT-Docomo of Japan, has many contents through the long and stable commercial service. Micro Explorer, which is developed by Stinger project, also has many additional function. In this paper, we designed and implemented WAP convertor which can accept C-HTML contents and mHTML contents. C-HTML format by I-Mode is a subset of HTML format, mHTML format by ME is similar to C-HTML, So the content provides can easily develop C-HTML contents compared with WAP and the other case. Since C-HTML, mHTML and WML are used under the mobile environment, the limited transmission capacity of one page is also similar. In order to make a match table. After that, we apply conversion algorithm on it. If we can not find matched element, we arrange some tags which only can be supported by WML to display in the best shape. By the result, we can convert over 90% contents.

Usefuless of Multi-functional Gastroduodenal Coil Catheter with Phantom (팬텀을 이용한 다기능 위.십이지장관 코일 카테타의 유용성 평가)

  • Lim, Jin-Oh;Kim, Tae-Hyung;Jung, Yang-Hwa;Choi, Won-Chan;Shin, Ji-Hoon;Song, Ho-Young
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.21-26
    • /
    • 2003
  • To evaluate the newly designed gastroduodenal coil catheter:in-vitro test. The coil catheter that we made in our laboratory was 150 cm. The coil that is made of stainless steel wire was composed 1.3 mm inner diameter and this coil spring was covered with heat-shrinkable polyethylene tube. To measure the length under fluorocopy, 8 radiopaque marks were attached at 5 cm, 10 cm, 11 cm, 12 cm, 13 cm, 14 cm, 15 cm, 20 cm apart from distal end of the catheter and 6, 2, 1 pores were made at 7 cm, 13 cm, 19 cm apart from the distal end. Radio-opacity and the amount of injected contrast was investigated in formerly used 5 Fr. vessel catheter, which is possible in measuring length, and newly designed coil catheter. Film density was tested for radio-opacity with autodensitometer. For measuring the volume of injected salin, the catheter was located in the acryl box(26 cm, 3 cm, 16 cm) that divided into 4 chambers. After injection 50 cc of contrast with autoinjector, the contrast's quantity in each chamber was measured with and without over the guide wire. Radio-opacity was 0.51 in 5 Fr. vessel catheter, 0.31 in newly made catheter. The amount of injected contrast was measured. In case of 5 Fr. vessel catheter, the amount was 99.5% from the distal part, there was no difference between with and without the guide wire. Otherwise, using a coil catheter, the pacentage the ejected saline was 1.17%, 18.8%, 41.8%, 38.2% from the distal part with the guide wire, 19.5%, 32.6%, 27.7%, 20.3% without the guide wire. Compare with formerly established catheter, this new coil catheter is easy to measure the length thanks to easy confirming under fluoroscopy and excellent in injecting contrast. Therefore, newly designed gastrointestinal catheter seems to be useful in gastrointestinal intervention procedure.

  • PDF

Analysis of Annual Variability of Landfast Sea Ice near Jangbogo Antarctic Station Using InSAR Coherence Images (InSAR 긴밀도 영상을 이용한 남극 장보고기지 인근 정착해빙의 연간 변화 분석)

  • Han, Hyangsun;Kim, Yeonchun;Jin, Hyorim;Lee, Hoonyol
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.6
    • /
    • pp.501-512
    • /
    • 2015
  • Landfast sea ice (LFI) in Terra Nova Bay, East Antarctica where the Jangbogo Antarctic Research Station is located, has significant influences on marine ecosystem and the sailing of an icebreaker. Therefore, it is essential to analyze the spatio-temporal variation of the LFI in Terra Nova Bay. In this study, we chose interferometric pairs with the temporal baseline from 1 to 9 days out of a total of 62 COSMO-SkyMed synthetic aperture radar (SAR) images over Terra Nova Bay obtained from December 2010 to January 2012, and then constructed the coherence image of each pair. The LFI showed coherence values higher than 0.3 even in the interferometric SAR (InSAR) pairs of up to 9-days of temporal baseline. This was because the LFI was fixed at coastline and thus showed low temporal phase decorrelation. Based on the characteristics of the coherence on LFI, We defined the areas of LFI that show spatially homogeneous coherence values higher than 0.5. Pack ice (PI) and open water showed low coherence values due to large temporal phase decorreation caused by current and wind. Distinguishing PI from open water in the coherence images was difficult due to their similarly low coherence values. PI was identified in SAR amplitude images by investigating cracks on the ice. The extents of the LFI and PI were estimated from the coherence and SAR amplitude images and their temporal variations were analyzed. The extent of the LFI increased from March to July (maximum extent of $170.7km^2$) and decreased from October. The extent of the PI increased from February to May and decreased from May to July when the LFI increases dramatically. The extent of the LFI and air temperature showed an inverse correlation with a time lag of about 2 months, i.e., the extent of the LFI decreases after 2 months of the increase in the air temperature. Meanwhile the correlation between wind speed and the extent of the LFI was very low. This represents that the extent of LFI in Terra Nova Bay are influenced more by the air temperature than wind speed.

프렌차이점에서 사용되는 튀김류의 산패도 및 트랜스지방의 함량 비교

  • Kim, Yeong-Seong
    • Proceedings of the Korean Sanitation Conference
    • /
    • 2005.12a
    • /
    • pp.76-97
    • /
    • 2005
  • As the recent change of multiformity and taste in clination in eating habit culture is yearly in creasing foods used oil and fats. Because the frying food is especially important snack , it's safty is very essential. In order to know the safty and harmfulness of frying oil and fats. The 20 kinds samples were purchased chicken fried food shops around the north of seoul and kyunggi. The acid value, iodine value, peroxide value, TBA value, fatty acid, carbonyl value, and smoke point of deep fat fried oils were analyzed. Results of analyzed, A company of deep fat frying oil showed stability state and C company and B company of deep fat frying oil is acidification to turned. But D company of deep fat frying oil showed quite a bit acidification progressived of used hydrogenated oil.

  • PDF

Comparison of VATS with Thoracotomy for the Treatment of Spontaneous Pneumothorax (자발성 기흉의 치료에서의 비디오 흉강경 수술과 개흉술의 비교)

  • 김문수;김영태;김기봉;김원곤;성숙환;김주현
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.294-298
    • /
    • 1999
  • Background: Video-assisted thoracoscopic surgery(VATS) has been established as a new method for treatment of spontaneous pneumothorax. We compared the clinical results of VATS with those of thoracotomy performed during the recent 5 years. Material and Method: We analyzed 126 patients whose medical records were available among the 154 patients who underwent operations for spontaneous pneumothorax from 1992 to 1996. The mean age was 27.1 years(15 to 75 years). 87 patients were operated on by VATS(Group A) and the other 39 by thoracotomy(Group B). The mean follow-up period was 14.7 months. Result: The operation time was shorter in group A than in group B(90.6${\pm}$38.6minutes: 117.2${\pm}$58.9minutes, p<0.05). The duration of postoperative hospital stay was shorter in group A than in group B(6.7${\pm}$4.2: 9.4${\pm}$3.3 days, p<0.05). The amount of analgesics(nalbuphin HCl, ketoprofen) used postoperatively were 2.4${\pm}$2.8 ampules in group A, which is less than the 6.5${\pm}$5.6 ampules in group B(p<0.05). The number of staples used in group A was smaller(2.7${\pm}$1.3 in group A, 1.76${\pm}$1.1 in group B, p<0.05). The duration of chest tube indwelling(4.3${\pm}$4.0 days in group A, and 5.6${\pm}$3.0 days in group B, NS), the recurrence rate(13.8% in group A, 2.6% in group B, NS), and the duration of air leakage(1.3${\pm}$3.3 days in group A, and 1.0${\pm}$2.5days in group B, NS) were not statistically different between the two groups. Conclusion: The application of VATS for the treatment of spontaneous pneumothorax has brought in better clinical results(shorter operation time, shorter hospital stay, less pain, and better cosmetic merits) than the thoracotomy without increasing any morbidity. However no advantages in recurrence rates and duration of postoperative air leakages are revealed.

  • PDF

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.

Blood Pressure of Healthy Newborns in the First Week of Life (분당 차병원에서 출생한 신생아 혈압치 비교)

  • Lee Jung-Sun;Park Shin-I;Park Hye-Won;Kim Se-Hyun;Hah Tae-Sun;Lee Jun-Ho
    • Childhood Kidney Diseases
    • /
    • v.9 no.1
    • /
    • pp.8-14
    • /
    • 2005
  • Purpose : This study was peformed to study normative blood pressure data in full-term neonates that may be used to facilitate Identification of neonatal hypertension.Methods : 383 newborns born in our hospital from May 2003 to January 2004 were enrolled in this study Using an oscillometric device(BP-88 NEXT, COLIN Corp.), their blood pressures were measured more than one time within a week after birth. According to each clinical variable such as sex, delivery mode, birth weight, gestational age and presence of maternal disease or perinatal problems, we divided the population into groups and calculated the mean blood pressures of each group. We compared mean blood pressures between the divided groups according to each clinical variable statistically.Results : Mean systolic and diastolic blood pressure of the Population was 70.8$\pm$ 10.9 mmHg and 43.4 $\pm$ 8.0 mmHg, respectively. There was no satistically significant difference in blood pressure according to clinical variables. Mean systolic pressure showed positive correlation with birth weight and gestational age(r=0.1420, 0.03130).Conclusion : Our results are almost in agreement with Zubrow's data from 695 newborns in U.S.A, 1995. Our data may be helpful for early detection and management of neonatal hypertension, thereby maintaining renal function ,and preventing possible complications of renal disease.

  • PDF

Study on the Usefulness of Using Anterior and Posterior Views for Calculation of Total Relative Uptake Ratio in 99mTc-DMSA Renal Scan (99mTc-DMSA 검사에서 상대 신섭취율 산출 시 양면상 촬영의 유용성에 대한 고찰)

  • Kim, Joo-Yeon;Lee, Han-Wool;Kwon, O-Jun;Kim, Jung-Yul;Park, Min-Soo;Cho, Seok-Won;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose $^{99m}Tc-DMSA$ renal scintigraphy serves as location, size and shape of kidney, so it has been used for diagnosis and passage observation after the operation or treatment. There are 3 methods of calculating the relative renal uptake ratio such as geometric mean of the counts from the anterior and posterior views, arithmetical mean from the only posterior view and posterior view which applied the renal depths. In this study, we seek to correlation between the change of total relative uptake ratio according to different inspection methods of obtaining the renal count rate. Materials and Methods The phantom experiments proceeded 5 times depending on each renal depth with the kidney phantom and tissue equivalent materials. In the clinical research, we investigated 36 adult patients who had visited our hospital from february to october, 2014 and received $^{99m}Tc-DMSA$ renal scan. The equipment was used as a gamma camera named INFINIA (General Electric Healthcare, milwaukee, USA) and we drew the region of interests through semiautomatic method by using Xeleris Ver. 2.1220 of GE. In addition, we obtained the lateral view of kidney to measure the renal depth of each patient. Then the results were compared with 3 methods of calculating relative renal uptake ratio. Results The phantom studies show when the difference between the left ant right kidney depth were less than 1 cm, there were no statistically significant difference among values calculated through anterior and posterior views and only posterior view (P>0.05), while the excess of 1cm, the results showed a statistically significant change in the value (P<0.05). In case of clinical research, the correlation between total relative uptake ratio by obtaining both sides of image and posterior view applied the kidney depth (r=0.999) was higher than by obtaining only posterior view and applying the kidney depth to one side image (r=0.988). Conclusion This study has found that, the difference of calculating total relative uptake ratio compared with obtaining anterior and posterior views and only posterior view. In order to reduce the error, we recommend the method of obtaining anterior and posterior views and is considered to be useful, particularly the patients have similar uptake ratio of left and right kidney and difficulties of measurements of kidney depth.

  • PDF

The Impact of monsoon Rainfall (Changma) on the Changes of Water Quality in the Lower Nakdong River (Mulgeum) (장마기의 강우가 낙동강 하류 (물금) 수질에 미치는 영향)

  • Park, Sung-Bae;Lee, Sang-Kyun;Chang, Kwang-Hyeon;Jeong, Kwang-Suek;Joo, Gea-Jae
    • Korean Journal of Ecology and Environment
    • /
    • v.35 no.3 s.99
    • /
    • pp.160-171
    • /
    • 2002
  • The impact of summer monsoon on water quality of the lower Nakdong River was evaluated during the summer (June-August) in 1997. Several limnological variables were measured in the interval of $1{\sim}3$ day using an automatic monitoring system (Hydrolab $Recorder^{TM}$) to detect water quality changes caused by rainfall on onehour basis. During the monsoon period (from late June to mid July), 5 times of major rainfall events of >50 mm were recorded in the river basin. Dynamic changes of water quality were observed during the monsoon, and the first rainfall event (June$25{\sim}27$) had a significant influence on the water quality at the lower part of the river. All Parameters were largely changed due to the first rain event, and the changed level was maintained until the end of monsoon period. Nutrient concentrations and turbidity increased and values of the other parameters were declined as a result of water dilution. This rainfall event, Changma, is a meteorological phenomenon caused by the East-Asian monsoon climate. The magnitude and frequency of the rainfall during the early monsoon play an important role in change of water quality and ecosystem characteristics of large river systems.