Analysis of Building Characteristics and Temporal Changes of Fire Alarms (건물 특성과 시간적 변화가 소방시설관리시스템의 화재알람에 미치는 영향 분석 연구)

  • Lim, Gwanmuk;Ko, Seoltae;Kim, Yoosin;Park, Keon Chul
    • Journal of Internet Computing and Services
    • /
    • v.22 no.4
    • /
    • pp.83-98
    • /
    • 2021
  • The purpose of this study to find the factors influencing the fire alarms using IoT firefighting facility management system data of Seoul Fire & Disaster Headquarters, and to present academic implications for establishing an effective prevention system of fire situation. As the number of high and complex buildings increases and former bulidings are advanced, the fire detection facilities that can quickly respond to emergency situations are also increasing. However, if the accuracy of the fire situation is incorrectly detected and the accuracy is lowered, the inconvenience of the residents increases and the reliability decreases. Therefore, it is necessary to improve accuracy of the system through efficient inspection and the internal environment investigation of buildings. The purpose of this study is to find out that false detection may occur due to building characteristics such as usage or time, and to aim of emphasizing the need for efficient system inspection and controlling the internal environment. As a result, it is found that the size(total area) of the building had the greatest effect on the fire alarms, and the fire alarms increased as private buildings, R-type receivers, and a large number of failure or shutoff days. In addition, factors that influencing fire alarms were different depending on the main usage of the building. In terms of time, it was found to follow people's daily patterns during weekdays(9 am to 6 pm), and each peaked around 10 am and 2 pm. This study was claimed that it is necessary to investigate the building environment that caused the fire alarms, along with the system internal inspection. Also, it propose additional recording of building environment data in real-time for follow-up research and system enhancement.

A Research to Minimizing the Effect of Voltage Disturbances on Sensitive Electrical and Electronic Equipment (민감한 전기전자기기의 전압외란에 대한 영향 최소화 연구)

  • 윤갑구
    • Journal of the Korean Professional Engineers Association
    • /
    • v.19 no.2
    • /
    • pp.10-20
    • /
    • 1986
  • This paper describes a countermeasure of electric utilities and customer equipment in order to minimize an effect of sensitive electrical and electronic equipment on the voltage disturbances. After being studied, some schemes to solve were discovered. Firstly, in the electric utilities, the reduction of frequency and influence of voltage drop's time are not easy to realize because of the standpoint of effect and economy. Secondly, in the customer equipment, there are some equipment to minimize the voltage disturbances, Such as an UPSs, a noise suppressors and a power conditioners. One of them should be established on the computer control and automated systems, the electromagnetic switch of delay-release type should be adopted on the electromagnetic switch, the controlling circuit should be adopted on the variable speed motors which is being considered a countermeasure for a momentary under-voltage drops, the luminaire adhering a instantaneous restrike device should be adopted on the HID lamp. And also, the scheme of extending a setting time of relay on the undervoltage relay and the forming method of sequence which is automatic reclosing at this time of instantaneous suspension of an electric supply have been studied.

  • PDF

Development of Universal Remote Control System using TFT Color LCD (TFT Color LCD를 사용한 통합형 리모컨 개발)

  • Kim Yong-Pyo;Yoon Dong-Han;Choi Un-Ha
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.8
    • /
    • pp.1495-1501
    • /
    • 2006
  • In this paper, It is purposed to Develope Development of Home Automation Remote Control System using W Color touch LCD(liquid crystal display). This control remotely with remote control innovative and ergonomic design, right combination of LCD and hard buttons and its industry leading technology puts your customers at the cutting-edge of home entertainment. Remote Control for casual users is programmed automatically programmed with multiple free step macros and IR commands. Radio Frequency (RF) operation provides 50-100 inch range though walls and doors. Editor includes a vast library of IR codes for hundreds of brands and models of A/V components. This database is constantly growing with the inclusion of new devices every month. Keep your software up to date by using the Live Update feature. Rather than un-installing and re-installing the software, you download updates to the software from the internet.

Development of Heating Device Using Concentrator Solar Cells (집광형 태양전지를 이용한 난방장치 개발)

  • Lee, Dong Il;Baek, Seung Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.1
    • /
    • pp.49-56
    • /
    • 2014
  • In this study, the generation efficiency of the limited area of a concentrator solar cell was increased by using a solar concentrator and a tracking device. Heat generated by the solar cell was collected using a thermal absorber for supplying hot water or heating. Thus, the concentrator solar cell system provided electricity and heat simultaneously. Tracking of the sun by detecting the sun's position, repositioning of heating device towards the east after sunset, and shutting down of system after sunset were successfully implemented using an illuminance sensor (CdS) and Simulink, a commercial software package. We performed parametric analysis of the velocity, fin installation, and entrance location with respect to the operating temperature of the concentrator solar cell. A heat transfer simulation model was developed for comparing the actual temperature profiles of the concentrator solar cell and thermal absorber, and good agreement was found between the results of the simulations and the experiments.

Test of Communication Distance Measurement of Fishing Gear Automatic System Based on Private LoRa (Private LoRa 기반 어구 자동식별 시스템의 거리 측정 시험)

  • Lee, Seong-Real;Kim, Se-Hoon
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.2
    • /
    • pp.61-66
    • /
    • 2020
  • Since the ocean accounts for 70.8 percent of the earth's surface, the success of IoT technology in the marine industry is to collect information from devices placed in a wider range. LPWA is a feature with a wide range of communication and is very suitable for deployment in the ocean. In this paper, the real-sea performance distance experiment was carried out based on Private LoRa, a key technology for executing the electronic phrase real-name system. A private LoRa module based on sx1276 was developed, and Gateway was developed to transfer data received by private LoRa to the server using SKT Cat. M1. After installing gateways at 599 meters above sea level and experimenting with data transmission and reception at 25 km, 40 km and 60 km, we were able to see that the communication success rate was obtained to be 96.1%. 97.1% and 96.2% respectively.

A Real Time Monitoring for Water Quality of River (수질자동모니터링시스템의 설치 현황과 전망)

  • Ryu, Jae-Kuen
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • Water quality is monitored at 1,837 points which are streams and sources for water supply in Karea. The monitoring carry out the measurement of 16 parameters of pH, BOD, SS, DO and so on with once a month, and of other parameters such like heavy metal with once a quarter. But most of the monitoring is carried out uncontinuously, so it is very difficult to understand exactly the changes of water quality compared with continuous monitoring. Therefore, real time monitoring system was equipped with basic parameters such as pH, temperature, DO, turbidity and electric conductivity at 25 major sources of water supply after installation of Noryangjin and Dukdo in 1974. But the systems have some problems which cannot be considered the sampling sites to represent for water quality of stream of lake, and can be caused a change of water quality by long distance from analyzer to intake pipe. Therefore, it has carefully to evaluate selection of sample sites for real time monitoring system. Also, problems on the area has been to identify which parameters are best suited to monitoring stream of lake water and the differences, of analyzing results compared with manual analyzing. This paper presents some approaches to handle such problems, namely selection of sampling site and measurable parameters, to connect with bio-monitoring system solving a Limitation of measurable parameters, The bio-monitoring system of an early alarm that is desirable to perceive a toxic material inflow into stream can be applied to continuos water quality monitoring system effectively. Also, this paper presents to build a on line system transmitting immediately from a mobile analyzer house or container to main monitoring center the results of analyzer by a telemeter.

Developing Data Exchange Standard between Roadside-device and Traffic Information Center in accordance with ISO 15784 (ISO 15784를 적용한 교통정보센터와 노변장치간 데이터 교환 표준 개발 _ AVI를 중심으로)

  • Lee, Sang-Hyun;Son, Seung-Neo;Kim, Nam-Sun;Cho, Yong-Sung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.3
    • /
    • pp.29-41
    • /
    • 2013
  • This study set out to developing data exchange standard between roadside device and traffic information center fitted in a domestic environment by applying international standard ISO 15784. First, we defined message basic concept of 'Dialog' and essential elements should be defined to define the standard message for securing system compatibility by reference ISO 14817 and ISO 14827 Part 1. For defining standard message items exchanged between AVI and traffic information center, we formed Working Group under ITS Standards Technical Committee and analyzed data flow for ITS National Architecture, Standard messages of existing standards, and AVI operation messages actually operated on roadside now. So, we extracted 14 functionally needed messages and defined 28 standard messages adopting 'Dialog' concept. In case of the application protocol for data exchange standards, we defined basic requirements for securing interoperability and interchangeability considering domestic environment by analyzing reference standard of ISO 15784.

Development of Speed Measurement Accuracy Using Double Loop Detectors (2중 루프검지기 속도측정 정확도 개선 알고리즘 개발)

  • 강정규
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.5
    • /
    • pp.163-174
    • /
    • 2002
  • Speeding has been reported as one of the major causes for fatal traffic accidents in Korea. The resolution against this dangerous speeding comes to make the automated speed enforcement system an enforcement tool. The speed detection device, which measures speeds of each incoming vehicles using double loop sensors, requires high accuracy. The object of this study is to develop an accurate speed measurement algorithm using double loop detectors. Some important findings are summarized as follows: 1) It was found that speed measurement errors are caused by scanning rate, distance of two loops, irregular vehicle trajectories, multiple vehicles in detection zone. 2) A proposed algorithm using two signal set proved to reduce variance as well as mean of speed measurement. 3) A proposed filtering algorithm was effective to filter irregular driving vehicles and multiple vehicles in detection zone. A comprehensive field test of developed algorithm resulted in significant improvement of speed measurement accuracy.

The Evaluation of Occupational Health Program at a Granite Company in U.S.A. (일개 채석산업장의 산업보건프로그램 평가)

  • Yi, Sung-Eun
    • Research in Community and Public Health Nursing
    • /
    • v.13 no.3
    • /
    • pp.574-583
    • /
    • 2002
  • '채석(quarrying)'산업은 노천광산에서 광물을 캐내는 작업을 모두 포함하는 광범위한 산업을 의미한다. 1900년대에 들어오면서 채석작업에 홈연소기(channel burner)을 이용한 불꽃절개법(flame cutting)이 이용하여 근로자의 먼지 노출이 많이 감소하였다. 채석작업으로 인한 주 된 건강문제는 먼지, 소음, 진동 노출이며, 노천작업장으로 작업환경이 개방되어 있어 환경측정 및 관리가 불가능하므로 개별근로자의 먼지와 소음 노출 측정 및 예방이 중요하다. 본 연구는 미국의 일개 채석회사의 근로자 건강관리사업을 평가하였다. 연구자료는 저자가 현장 방문을 통하여 구한 자료와 연구대상 회사의 안전관리자의 의견 및 미국 산업안전보건국 전산자료를 이용하였다. 채석사업장에서 이루어지는 작업은 크게 채석작업과 실내에서 이루어지는 가공작업 및 운반과 보관이며, 미국 산업안전보건국(OSHA)의 표준산업분류(SIC)에서 1411(채석업)과 3281(채석가공업)에 해당한다<표 1>. 연구 대상 사업장에서 이루어지는 산업보건프로그램은 먼지 노출 예방을 위해 석재 채취시 물분사법(water jet quarrying)과 국소환기법을 사용하고 소음 노출 예방을 위해 귀마개를 사용하며 사고 예방을 위하여 안전모와 철모, 보안경, 안전조끼, 보호장갑, 안전끈(harness)을 착용하였다. 평가 결과로 나온 연구 대상 사업장에서 적용하여야 할 산업보건 프로그램은 첫째, 먼지 노출로 인한 건강문제를 예방하기 위하여 근로자 개별 노출 측정을 하고, 둘째 실내가공작업장의 근로자를 대상으로 한 먼지와 소음 노출 측정 및 환경측정이 필요하며, 셋째 안전관리를 위해 채석장에 안전표지판을 설치하여야 하며, 실내가공 작업장의 자동이동시스템을 작업별로 채색하여 식별을 용이하게 하여야 하겠다. 또한 이 연구 결과를 영세사업장의 산업간호프로그램인 'Clean 3D'사업에서 적용하여 우리나라 채석사업장 근로자 건강관리를 발전시켜야 하겠다.

  • PDF

A Study on a Shipborne Automatic Identification System

  • Wen -Li Sun;Fu-Wen Pang;Sang-Ku Hwang;Tchang-Hee Hong
    • Journal of the Korean Institute of Navigation
    • /
    • v.22 no.2
    • /
    • pp.13-22
    • /
    • 1998
  • Shipbome Automatic Identification System (AIS) will be an important manne equipment used for identification, surveillance and communication in the 21st century, which is currently being researched in developed countries. A technical scheme of AlS is proposed in this paper. The main component of the AlS is a broadcast transponder, and the core technology is a VHF radio data link with high capacity, named STDMA (Self-organized Time Division Multiple Access). The ships installed the AlS, which will automatically and periodically broadcast their positions and identities in the marine VHF channels, can be displayed on a screen of an ECDIS on board or in VTS centers. The AlS is able to support not only broadcast service but also point-to-point communication service. This paper presents the configuration, operation principle and functionality of the AlS as well as the scenario of STDMA. In addition, the standardization work of AlS in IMO is introduced in this pauer, too.

  • PDF