• Title/Summary/Keyword: 자기 공명 혈관조영술

Search Result 51, Processing Time 0.026 seconds

Evaluate the Possibility of MT Pulse at 3T CE-TOF-MRA in Patients with Cerebral Infarction (뇌경색 환자의 3Tesla CE-TOF-MRA에서 MT 펄스의 유용성)

  • Bae, Sung-Jin
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.265-270
    • /
    • 2007
  • The purpose of this study was to evaluate the possibility of utilizing MT pulse at CE-TOF-MRA in patients with cerebral infarction. MRA using time-of-flight(TOF) technique with varying offset frequencies (0, 600, 1,200, and 1,800 Hz) magnetization transfer were performed in 10 patients with cerebral infarction at 3.0T MR scanner. CE-TOF-MRA and TOF-SPGR in normal vessel shown decreased SNR and increased CNR. The highest CNR in narrowing vessel shown at CE-TOF-MRA using 600 and 1,200 Hz offset frequencies. CNR in stenosis vessel increased dependent on using offset frequencies. The occlusion was clearly shown, and the highest CNR in occlusion shown at CE-TOF-MRA using 1,800 Hz offset frequencies. There was no shape variation in narrowing vessel or no visualizing vessel.

  • PDF

MRI(Magnetic Resonance Imaging)의 원리와 응용

  • 오창현
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.4
    • /
    • pp.272-276
    • /
    • 1996
  • 1948년 Harvard 대학의 Purcell교수와 Stanford 대학의 Bloch교수가 핵자기 공명(Nuclear Magnetic Resonance : NMR) 현상을 발견한 이래로 NMR은 물질의 분자단위에서 화학적, 물리학적 성질을 밝혀내는 탁월한 방법으로 널리 이용되어 왔다. NMR 현상을 이용한 영상촬영법(Magnetic Resonance Imaging, MRI)은 1970년대초 Lauterber와 Damadian 교수가 처음 영상을 얻을 수 있다는 가능성을 제시한 이후 급속한 발전을 하여 1980년대 초에는 Moore와 Holland에 의해 의학분야에 응용 가능할 정도의 영상이 얻어졌다. 1980년대 중반부터 상용화 되었으며 최근 그 기법도 NMR현상과 연관된 파라미터인 $T_{1}$, $T_{2}$는 물론 혈류의 속도, 자화율, 확산(Diffusion), Perfusion의 영상기법을 비롯해 혈관조영술(MR Angiography), 뇌기능영상(Functional Imaging)등 과거에는 상상도 할 수 없었던 다양한 영상기법 개발되었다. 여기서는 먼저 MRI의 원리를 설명한 후 MRI의 여러 촬영기법들과 그 응용에 관해 설명하겠다.

  • PDF

A Communicating Bronchopulmonary Foregut Malformation Associated with Absence of the Left Pericardium - A case report - (좌측 완전 심낭결손증을 동반한 Communicating Bronchopulmonary Foregut Malformation - 1예 보고 -)

  • Yoo, Dong-Gon;Park, Chong-Bin;Kang, Pil-Je;Lee, Jong-Hyeog;Kim, Chong-Wook
    • Journal of Chest Surgery
    • /
    • v.40 no.11
    • /
    • pp.793-797
    • /
    • 2007
  • A communicating bronchopulmonary foregut malformation (CBPFM) is a rare congenital anomaly that is characterized by a fistula between isolated respiratory tissue and the esophagus or stomach, The presence of accessory lung tissue arising from the primitive gastrointestinal tube is a common factor in the development of all forms of bronchopulmonary foregut malformations. Recurrent pneumonia associated with cystic radiographic structures is a characteristic of the condition. Further imaging studies using esophagogram, bronchography, computerized tomography, MRI, and arteriography can help in making a diagnostic evaluation. The treatment is a surgical resection of the involved lung tissue, and fistula closure with a good prognosis. We encountered a case of CBPFM, who presented with an extralobar pulmonary sequestration and bronchogenic cyst communicating with a tubular esophageal duplication that was associated with a complete left pericardial defect.

A Study on the Image Quality According to the Change of Flip Angle in Flow-Related Enhancement Magnetic Resonance Angiography (유속증강 자기공명혈관조영술에서 숙임각 변화에 따른 영상의 질 연구)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.201-208
    • /
    • 2018
  • The purpose of this study was to investigate the optimal flip angle by measuring the SNR and CNR according to the angle of changes of the MRI technique using the Image J program. A total of 30 normal volunteers were assessed by using a 1.5T magnetic resonance imaging system (Philips, Medical System, Achieva). For the MRI angiography, we set the region of interest in four regions and evaluated the SNR and CNR. The statistical significance of SNR and CNR was calculated by one-way ANOVA using quantitative analysis at five different positions. The Bonferroni method was used for post-hoc analyzes. Statistical significance was determined by using ANOVA analysis at p<0.05 and Bonferroni method was used as a post-hoc analysis. The results of this study, the measurement values of ACA(SNR:$876.59{\pm}14.22$, CNR:$1999.7{\pm}12.5$), PCA(SNR:$863.48{\pm}13.29$, CNR:$1870.18{\pm}12.56$), ICA(SNR:$1116.87{\pm}08.34$, CNR:$2979.37{\pm}14.69$) and MCA(SNR:$848.66{\pm}15.25$, CNR:$2199.25{\pm}13.48$) were obtained with the high signal intensity at $25^{\circ}$(p<0.05). The values of a1, a2, a3, p1, p2, p3, m1, m2 and m3 were also the same (p<0.05). Post-hoc analysis results, There was a statistically significant difference (p=0.000) between $10^{\circ}$, $15^{\circ}$, $20^{\circ}$ on the $25^{\circ}$ reference for the flip angle, but no significant results were obtained with $30^{\circ}$(p<0.05). In concision, because the signal intensity decreased at $30^{\circ}$, this study revealed that the optimal flip angles were $25^{\circ}$ in cerebrovascular MR angiography.

Artifacts due to Retrograde Flow in the Artery and Their Elimination in 2D TOF MR Angiography (2D TOF 자기공명 혈관조영술에서 동맥혈류의 역류로 인한 영상훼손과 이의 제거)

  • Jung, K.J.;Lee, J.K.;Kim, S.K.;Park, S.H.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.38-42
    • /
    • 2001
  • Dark band artifacts are often observed in angiograms of arteries obtained by 2D time-of-flight (TOF) angiography with saturation of veins by presaturation RF pulses. At some arteries the arterial blood velocity varies in a triphasic pattern during a cardiac cycle. The arterial blood, that is saturated by presaturation RF pulses in the saturation band, can flow back into the imaging slice during the retrograde flow phase of the triphasic variation. When such saturated retrograde flow occurs during the acquisition of the central part of the K space, a signal void can result in base images and consequently dark band artifacts can appear in angiograms. This phenomenon is experimentally demonstrated by varying the gap between the imaging slice and the saturation band. Furthermore, a new pulse sequence is proposed to eliminate the dark band artifacts by changing the profile of the saturation band front a rectangle to a ramp.

  • PDF

A Study on the Radiographic Diagnosis of Caroli's Disease (카롤리병의 방사선학적 진단에 대한 고찰)

  • Yeo-jin Hong;Min-a Kim;Soo-bin Kim;Jin-joo Song;Kyoung-hoon Jang;Min-cheol Jeon;Man-Seok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.385-392
    • /
    • 2023
  • Caroli's disease is a fibrocystic liver disease. Autosomal recessive disorder is characterized by congenital multiple dilatation of the bile duct. Computerized tomography, magnetic resonance imaging, cholangiography and ultrasound are among the methods for diagnosing caroli disease. Computerized tomography is essential for detecting and distinguishing fibroplastic liver disease and is useful for determining intrahepatic bile duct dilatation. However, awareness of the possible side effects of using contrast mediums is necessary. A typical method of magnetic resonance cholangiography is used for magnetic resonance imaging. A non-invasive examination can reduce the pain of the patient, and the anatomical structure of the bile pancreatic duct and the presence or absence of lesions can be easily and quickly observed. Biliary contrast is an effective diagnostic method that can directly visualize various cystic dilatations throughout the enlarged bile duct. However, since this procedure is also an invasive procedure, it is recommended not for diagnosis but for treatment purposes. Ultrasonography can confirm similar findings to computerized tomography. The hepatic artery root is difficult to prove with conventional grayscale ultrasound. However, it is of clinical value in that it can not only describe dilated bile ducts with vascular roots in the tube but also easily identify color Doppler signals in the tube. With the development of video diagnostics, early diagnosis has become possible through computerized tomography, magnetic resonance imaging, cholangiography, and ultrasound. In order to further contribute to the development of video diagnostics so that long-term prognosis can be improved after treatment through early diagnosis, we examined what aspects of each test's caroli disease appear.

Surgical Treatment of Lemierre′s Syndrome -A case report- (Lemierre 증후군의 수술 치험 -1례 보고-)

  • 오정훈;이정철;이동협;이장훈;정태은;한승세
    • Journal of Chest Surgery
    • /
    • v.34 no.8
    • /
    • pp.644-647
    • /
    • 2001
  • Lamierre's syndrome is characterized by a rare fulminant condition resulting from primary oropharyngeal infection followed by secondary septic thrombophlebitis of the internal jugular vein and metastatic infection. A forty-year-old man who had been on ventilator due to servere chest trauma, showed severe reddish inflammatory swelling of the right cervical soft tissue and newly developed pneumonia. He went into in septic condition shortly thereafter. Thrombophlebitis with central abscess in the right internal jugular vein was identified by neck CT and MRA(magnetic resonance angiography). Right cervical swelling worsened in spite of clindamycin and heparin therapy. We performed immediate surgery for removal of septic thrombus and resection of internal jugular vein. Patient's septic condition, pneumonia, and local inflammatory reaction were improved within several days after surgery.

  • PDF

High-Resolution Contrast-Enhanced 3D-Spoiled Gradient-Recalled Imaging for Evaluation of Intracranial Vertebral Artery and Posterior Inferior Cerebellar Artery in Lateral Medullary Infarction (고해상도 조영증강 삼차원 회손기울기 회상 영상을 이용한 측면연수경색 환자의 두개내 척추동맥 및 뒤아래소뇌동맥 평가)

  • Yoon, Youngno;Ahn, Sung Jun;Suh, Sang Hyun;Park, Ah Young;Chung, Tae-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.17-24
    • /
    • 2014
  • Purpose : To determine whether high-resolution contrast-enhanced three dimensional imaging with spoiled gradient-recalled sequence (HR-CE 3D-SPGR) plays a meaningful role in the assessment of intracranial vertebral artery (ICVA) and posterior inferior cerebellar artery (PICA) in lateral medullary infarction (LMI). Materials and Methods: Twenty-five patients confirmed with LMI were retrospectively enrolled with approval by the IRB of our institute, and 3T MRI with HR-CE 3D-SPGR and contrast-enhanced magnetic resonance angiography (CE-MRA) were performed. Two radiologists who were blinded to clinical information and other brain MR images including diffusion weighted image independently evaluated arterial lesions in ICVA and PICA. The demographic characteristics, the area of LMI and cerebellar involvement were analyzed and compared between patients with arterial lesion in ICVA only and patients with arterial lesions in both ICVA and PICA on HR-CE 3D-SPGR. Results: Twenty-two of twenty-five LMI patients had arterial lesions in ICVA or PICA on HR-CE 3D SPGR. However twelve arterial lesions in PICA were not shown on CE-MRA. Concurrent cerebellar involvement appeared more in LMI patients with arterial lesion in ICVA and PICA than those with arterial lesion in ICVA alone (p = 0.069). Conclusion: HR-CE 3D-SPGR can help evaluate arterial lesions in ICVA and PICA for LMI patients.

Susceptibility-Contrast-Enhanced MR Venography of Cat Brain Using Tailored RF Pulse at High Magnetic Field of 4.7 Tesla Superconducting Magnet (4.7T 고자장 초전도 자석에서 Tailored RF를 이용한 고양이 뇌의 자화율 강조영상법에 의한 자기공명혈관 조영술)

  • Moon, Chi-Woong;Kim, Sang-Tae;Lee, Dae-Geun;Im, Tae-Hwan;No, Yong-Man;Cho, Jang-Hee;Lee, Yoon
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.55-66
    • /
    • 1994
  • After proving home-made imaging pulse sequences including tailored RF pulse by phantom, susceptibility-contrast-enhanced MR venograms of cat brain were obtained using tailored RF gradient-echo(TRGE) method. Sagittal MR imaging of the cat brain obtained by TRGE technique shows several veins, for example, dorsal sagittal sinus, straight sinus, vein of corpus callosum and internal cerebral vein, etc., compared with cats anatomical figure. Tailored RF waveform was generated by PASCAL language in ASPECT 3000 computer(Switzland, Bruker). Rectangular-shaped slice profile with bi-linear ramp function as phase distribution in the slice, at which maximum value was 2$\pi$, was fourier transformed to make tailored RF pulse. Experimental MR imaging parameters were TR/TE=205/10 msec, slice thickness TH=7mm, maxtrix size=256$\times$256, in-plane resolution=0.62$\times$0.31mm$^2$, and field of view(FOV)=8cm for both conventional gradient-echo(GE) imaging and TRGE imaging techniques.

  • PDF

Review and Implementation of Magnetic Resonance Angiography (자기공명 혈관조영술의 고찰 및 구현)

  • Yi, Y.;Ryu, T.H.;Ju, H.Y.;Kim, S.S.;Kim, I.Y.;Lee, M.W.;Oh, C.H.;Ahn, C.B.;Lee, H.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.223-226
    • /
    • 1997
  • X-Ray Angiography has been gold standard for imaging of blood flow. However, patients have to take many risks such as catheterization procedure, iodine contrast agent and ionizing X-rays. MR Angiography has been suggested as a substitute for its non-hazard to patient. But the resolution and contrast was inferior to that of X-ray Angiography. Recently the resolution and the contrast have been much improved due to the development of fast imaging technique. Here we report some preliminary results of the MR Angiography we have implemented on 1 Tesla MRI unit.

  • PDF