• Title/Summary/Keyword: 자기일치법

Search Result 94, Processing Time 0.028 seconds

Detection of Brain Metastatses Using Limited Brain MR Imaging : Usefulness of Limited Contrast-Enhanced MR Imaging in Brain Metastasis (뇌전이암 진단을 위한 제한적 뇌 자기공명영상의 유용성에 관한 연구)

  • Kwon, Sun Jung;Lee, Yun Sun;An, Jin Yong;Park, Hee Sun;Jung, Sung Soo;Kim, Ju Ock;Kim, Jin Hwan;Song, Chang Joon;Kim, Sun Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.5
    • /
    • pp.499-505
    • /
    • 2003
  • Background : The brain is a common site of a metastasis in lung cancer patients. If left untreated, the patients succumb to progressive neurological deterioration with a lower survival rate than with other metastases sites. Contrast-enhanced MR imaging in the absence of symptoms or clinical signs is not recommended for identifying a cerebral metastasis in lung cancer patients because of management effectiveness. This pilot study was performed to estimate whether or not limited brain MR imaging, which has a lower cost, could be used to replace conventional brain MR imaging. Method : Between April 1999 and March 2001, 43 patients with a primary lung cancer and the others (breast cancer, stomach cancer, colon cancer, malignant melanoma etc), who had neurological symptoms and signs, were examined using conventional brain MR imaging to examine brain metastases. The control group involved four patients who had no evidence of brain metastases the sensitivity, specificity and correlation of limited brain MR imaging were compared with conventional brain MR imaging. Results : All the 43 patients who were examined with conventional brain MR imaging showed evidence of brain metastases, whereas limited brain MR imaging indicated that 42 patients had brain metastases(sensitivity=97.67%). One patient in whom limited brain MR imaging showed no brain metastasis had a metastasis in the cerebellum, as shown by the contrast-enhanced T1 weighted axial view using conventional brain MR imaging. The conventional brain MR imaging and the limited brain MI imaging of the 4 control patients both indicated no brain metastases (specificity=100 %). The Pearson Correlation of the two groups was 0.884(Confidence Interval : 99%) observed. Conclusion : Limited brain MR imaging can detect a brain metastasis with the same accuracy. In addition, it is cost-effective (229,000 won, 180$) compared to conventional brain MR imaging(529,000 won, 480$) when patients had neurological symptoms and signs or staging.

Design of Steering Controller for Autonomous Vehicle System on Magnetic Based Using Neural Network (신경망을 이용한 자계기반 자율주행 시스템의 조향 제어기 설계)

  • Lim Dae-Young;Jung Young-Yoon;Ryoo Young-Jae
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2005.11a
    • /
    • pp.185-188
    • /
    • 2005
  • 본 논문에서 신경망을 이용한 자계기반 자율주행 시스템의 조향 제어기 설계를 제안한다. 자율주행시스템에서 가장 중요한 핵심요소는 자계토로상의 센서의 현재위치를 파악하고 주행하는 것이다. 먼저 자계도로상의 현재위치를 파악하기 위한 방법으로, 첫 번째 자기쌍극자 모델식이 센서에서 측정된 자계와 일치함을 보였다. 두 번째 Peak Mapping법을 이용하여 외란으로 작용하는 지자계 성분을 제거할 수 있음을 입증하였다. 세 번째로 신경망을 이용하여 높이성분($B_{z}$)가 변하더라도 정확한 거리가 계측됨을 확인하였다. 따라서 신경망을 이용하면 소량의 메모리를 사용할 수 있으므로 실제 시스템에서 경제적인 효과를 볼 수 있고, 정확한 거리를 계측하므로 경로를 이탈하지 않고 자율주행이 가능한 시스템을 설계하였다.

  • PDF

Online MTPA Control of IPMSM for Automotive Applications Based on Robust Nonlinear Optimization Technique (비선형 최적화 기법에 기반한 자동차용 영구자석 동기전동기의 실시간 MTPA 제어)

  • Kim, Hyeon-Sik;Sul, Seung-Ki;Yoo, Hyunjae
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.71-72
    • /
    • 2017
  • 본 논문에서는 비선형 최적화 기법을 이용하여 자기 포화(magnetic saturation) 및 교차 결합 현상(cross-coupling effect)을 고려한 매입형 영구자석 전동기(IPMSM)의 실시간 MTPA 제어 방법을 제안한다. 이는 토크 지령 추종과 최소 동손 운전을 만족하는 제한 최적화(constraint optimization) 문제로 접근할 수 있다. 이를 통해 유도한 연립 비선형 방정식의 경우, Levenberg-Marquardt 수치 해석법을 적용하여 안정적이면서 빠르게 해를 구할 수 있다. 이러한 방법을 이용하면 참조표(look-up table) 없이 운전 환경의 실시간 변동을 고려한 효율적인 MTPA 운전이 가능하다. 시뮬레이션을 통해 제안된 알고리즘의 전류 해가 최적 운전점과 일치함을 확인하였다.

  • PDF

Study on Torque and Engaging time Analysis of Micro-Electromagnetic Clutch by Using FEM (FEM을 이용한 Micro-Electromagnetic Clutch 토크와 응답시간해석)

  • Park, Chang-Hao;Kim, Myoung-Gu;Lee, Heung-Shik;Cho, Chong-Du
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.18 no.1
    • /
    • pp.21-28
    • /
    • 2005
  • This study tries to analyzes the torque and engaging time generated in a micro-electromagnetic clutch by using FEM. For the purpose of design change and optimization of the micro-electromagnetic clutch, the torque prediction is very important. We employ a mathematical approach based on the electromagnetic principle. For torque prediction, real material properties are substituted to the constructed axi-symmetric FEM model to obtain the analytical torque and engaging time. The predicted torque and engaging time are compared with those obtained by experiments to discuss the validity of torque and engaging time analysis. The analytical results agrees well with experimental data, therefore explaining the validity of the torque and engaging time prediction method.

Wave propagation in an Inhomogeneous Anisotropic Medium through Variational Finite Element Method (변분 유한요소법에 의한 비균질 비등방성 매질에서의 전파특성)

  • 김현준;홍용인;김두경;김정기
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.3 no.1
    • /
    • pp.33-41
    • /
    • 1992
  • In this paper the propagation problems of waves nomally incident upon an anisotropic medium with arbitrary permittivity tensors are analyzed through the variational finite element method. First, a variational equation is derived from the new approach basd on the induction theorm, reactions, and reciprocity. Next, by using the finite element method, the propagation problems are solved from the obtained functional. Specially, the reflection and transmission coefficient and axis ratio are obtained on the case of normally incident upon a homogeneous and inhomogeneous anisotropic medium such as cold mgnetoplasma slab and showed agreement with those of the previous method.

  • PDF

Three-Dimensional Dosimetry Using Magnetic Resonance Imaging of Polymer Gel (중합체 겔과 자기공명영상을 이용한 3차원 선량분포 측정)

  • Oh Young-Taek;Kang Haejin;Kim Miwha;Chun Mison;Kang Seung-Hee;Suh Chang Ok;Chu Seong Sil;Seong Jinsil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.264-273
    • /
    • 2002
  • Purpose : Three-dimensional radiation dosimetry using magnetic resonance imaging of polymer gel was recently introduced. This dosimetry system is based on radiation induced chain polymerization of acrylic monomers in a muscle equivalent gel and provide accurate 3 dimensional dose distribution. We planned this study to evaluate the clinical value of this 3-dimensional dosimetry. Materials and Methods: The polymer gel poured into a cylindrical glass flask and a spherical glass flask. The cylindrical test tubes were for dose response evaluation and the spherical flasks, which is comparable to the human head, were for isodose curves. T2 maps from MR images were calculated using software, IDL. Dose distributions have been displayed for dosimetry. The same spherical flask of gel and the same irradiation technique was used for film and TLD dosimetry and compared with each other. Results : The R2 of the gel respond linearly with radiation doses in the range of 2 to 15 Gy. The repeated dosimetry of spherical gel showed the same isodose curves. These isodose curves were identical to dose distributions from treatment planning system especially high dose range. In addition, the gel dosimetry system showed comparable or superior results with the film and TLD dosimetry. Conclusion : The 3-dimensional dosimetry for conformal radiation therapy using MRI of polymer gal showed stable and accurate results. Although more studies are needed for convenient clinical application, it appears to be a useful tool for conformal radiation therapy.

A Study on the Protection of Personal Information in the Medical Service Act (의료법의 개인정보보호에 관한 연구)

  • Sung, Soo-Yeon
    • The Korean Society of Law and Medicine
    • /
    • v.21 no.2
    • /
    • pp.75-103
    • /
    • 2020
  • There is a growing voice that medical information should be shared because it can prepare for genetic diseases or cancer by analyzing and utilizing medical information in big data or artificial intelligence to develop medical technology and improve patient care. The utilization and protection of patients' personal information are the same as two sides of the same coin. Medical institutions or medical personnel should take extra caution in handling personal information with high environmental distinct characteristics and sensitivity, which is different from general information processors. In general, the patient's personal information is processed by medical personnel or medical institutions through the processes of collection, creation, and destruction. Still, the use of terms related to personal information in the Medical Service Act is jumbled, or the scope of application is unclear, so it relies on the interpretation of precedents. For the medical personnel or the founder of the medical institution, in the case of infringement of Article 24(4), it cannot be regarded that it means only medical treatment information among personal information, whether or not it should be treated the same as the personal information under Article 23, because the sensitive information of patients is recorded, saved, and stored in electronic medical records. Although the prohibition of information leakage under Article 19 of the Medical Service Act has a revision; 'secret' that was learned in business was revised to 'information', but only the name was changed, and the benefit and protection of the law is the same as the 'secret' of the criminal law, such that the patient's right to self-determination of personal information is not protected. The Privacy Law and the Local Health Act consider the benefit and protection of the law in 'information learned in business' as the right to self-determination of personal information and stipulate the same penalties for personal information infringement such as leakage, forgery, alteration, and damage. The privacy regulations of the Medical Service Act require that the terms be adjusted uniformly because the jumbled use of terms can confuse information subjects, information processors, and shows certain limitations on the protection of personal information because the contents or scope of the regulations of the Medical Service Law for special corporations and the Privacy Law may cause confusion in interpretation. The patient's personal information is sensitive and must be safely protected in its use and processing. Personal information must be processed in accordance with the protection principle of Privacy Law, and the rights such as privacy, freedom, personal rights, and the right to self-determination of personal information of patients or guardians, the information subject, must be guaranteed.

Crystal Structure and Magnetic Properties of $(LaS)_xCrS_2(x{\approx}1.20)$ ($(LaS)_xCrS_2(x{\approx}1.20)$의 결정구조와 자기적 특성)

  • Jo, Nam-Ung;Yu, Gwang-Su;Jeong, Hyeong-Jin
    • Korean Journal of Materials Research
    • /
    • v.4 no.6
    • /
    • pp.704-709
    • /
    • 1994
  • The $(LaS)_xCrS_2(x \approx 1.20$) of the incommensurate misfit layer was systhesized from reactant mixture of$La_S_3$,Cr and S at 1273K. Powder X-ray diffration of $(LaS)_xCrS_2(x \approx 1.20$) was indexed as a complex structure consisted with a monoclinic LaS-sublattice, a triclinic $CrS_{2}$-sublattice and their superlattice. The temperature dependence of sublattice dimension was investigated by the X-ray diffraction analysis at low temperature. The magnetic susceptibility of $(LaS)_xCrS_2(x \approx 1.20$) was measured between 77K and room temperature using a Faraday balance method. $(LaS)_xCrS_2(x \approx 1.20$) was paramagnetic on a $\sigma$-H plot at room temperature. The observed effective magnetic moment( p dr) was in fair agreement with the value calculated by spin-only contribution for $Cr^{3+}$ and spin and orbital contribution for $La^{3+}$.

  • PDF

Dissociation of the semantic and syntactic processing reflected on fMRI in Korean sentences (기능적 자기공명영상에 나타난 한글 의미.통사 문장 처리의 해리)

  • Lee, Hong-Jae;Lee, Dong-Hoon;Nam, Ki-Chun;Lee, Eun-Jung;Moon, Chan-Hong;Ryoo, Jae-Wook;Na, Dong-Gyu
    • Annual Conference on Human and Language Technology
    • /
    • 2000.10d
    • /
    • pp.405-410
    • /
    • 2000
  • 본 연구에서는 기능적 자기공명영상을 이용하여 한글 문장의 의미와 통사 처리에 관한 뇌의 활성화 양상을 비교함으로써 한글문장 이해의 과정에 대한 신경해부학적 증거를 찾고자 하였다. 6명의 자원자를 대상으로 문장진위판단과제를 이용하여 활성화를 유도하였다. 1.5T 초전도 자기공명영상 장치에서 EPI로 BOLD 기법을 이용하여 기능적 영상을 얻었으며 영상 후 처리는 SPM99 분석 프로그램을 이용하였다. 의미관련 통사관련 문장 모두에서 좌 우 전두회(frontal gyrus) 영역에서 활성화되었다. 의미와 통사처리 영역을 구분하기 위하여 감산법을 적용한 결과, 의미처리는 좌반구의 중측두회(middle temporal gyrus) 영역에서, 통사처리는 우반구의 하전두회(BA44) 부위에서 더 많이 활성화되었다. 의미처리에서 더 우세한 성향을 띠는 부위로 밝혀진 중측두회 영역은 의미처리시에 활성화되는 영역으로 보고하는 기존의 연구와 일치하는 결과이다. 의미와 통사 문장처리시의 뇌 활성화 양상은 뇌의 여러 영역에서 중첩되어 있기는 하지만, 특정영역에서의 차이를 보이고 있으므로, 의미와 통사처리는 다른 기전(mechanism)에 의해서 일어남을 시사해 준다.

  • PDF

Electronic Structures of Co-Pd Alloy Films Using Synchrotron Radiation Photoemission Spectroscopy (방사광 광전자 분광법을 이용한 Co-Pd 합금박막의 전자구조 연구)

  • 강정수;권세균;하양장;민병일;조용필;이창섭;정인범;구양모;김건호
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.6
    • /
    • pp.405-410
    • /
    • 1996
  • Valence band photoemission spectroscopy (PES) measurements have been performed for $Co_{x}Pd_{100-x}$ alloy films using synchrotron radiation (x = 0, 25, 40, 65). Then the partial spectral weight distributions (PSW's) of Co 3d and Pd 4d electrons have been determined. The Co 3d PSW's exhibit some structures which are quite different from those of the Co film for x < 25 %, whereas they become very similar to those of the Co film for x > 40 %. For x < 25 %, the peak near the Fermi level ($E_F$) and a shoulder around 2 eV binding energy in the Co 3d PSW reflect large hybridization between Pd 4d and Co 3d electrons, suggesting that the hybridization might play an inportant role in determining perpendicualr magnetic anisotropy. The Pd 4d PSW's in Co-Pd alloy films are found to have larger FWHM's (full widths at half maximum), larger binding energies of the main peaks, and larger spectral intensities at $E_F$ than the PES spectrum of the Pd film. The FWHM of the Pd 4d PSW increases with decreasing Pd concentration, which are considered to reflect the disordering effect in the alloy formation or the change in the Pd 4d electronic structure due to hybridization between Co 3d and Pd 4d electrons.

  • PDF