• Title/Summary/Keyword: 자가 형광

Search Result 274, Processing Time 0.03 seconds

Water-Soluble Distyrylbenzene Fluorophore and Fluorescence Behavior in a Polymeric Vesicle

  • Nayak, Rati Ranjan;Woo, Han-Young
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.6
    • /
    • pp.513-519
    • /
    • 2007
  • A vesicle forming polymer, poly(sodium acrylamidoundecanoate) (PSAU) and a water-soluble distyrylbenzene- based fluorophore, TPADSB-C were synthesized and characterized by using UV-vis and photoluminescence (PL) spectroscopy. An inter-chain vesicle formation of PSAU was observed at ~0.01 g/L from N-phenyl naphthylamine fluorescence measurement with changing PSAU concentration in water. Above critical aggregation concentration of PSAU, optical properties of TPADSB-C were investigated to study the microenvironment modulation through dye incorporation in the polymeric vesicle. The emission of TPADSB-C in the presence of PSAU vesicles was blue-shifted and the PL quantum efficiency was increased to 90% due to the microenvironment (e.g. polarity) change in aqueous solution. This study shows that the polymeric vesicle containing molecular fluorophores has a great potential as an efficient, stable and biocompatible labeling tag in biological cell imaging.

Properties of photoluminescence and time-resolved photoluminescence in doped GaAs (도핑된 GaAs의 형광 및 시간분해 형광 특성)

  • 추장희;서정철;유성규;신은주;이주인;김동호
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.213-217
    • /
    • 1997
  • We have measured photoluminescence (PL) and time-resolved PL in doped-GaAs. As increasing doping concentration, the PL spectra of n-type GaAs shift to higher energies while the PL spectra of p-type GaAs shift to lower energies than the bandgap of the undoped GaAs. The contribution of the Burstein-Moss effect overrules the band-gap narrowing in n-type GaAs, contrary to p-type GaAs. The PL rise time and decay time become shorter as increasing doping concentration. The PL rise and decay time in doped-GaAs depend on the type of majority carriers and their concentrations, which imply that the carrier-carrier interaction plays an important role in the energy relaxation processes.

  • PDF

Shear Induced Homogenization Study of an Immiscible Polymer Blend Solution Using Fluorescence Microscope (형광 현미경을 이용한 비상용 고분자 블렌드 용액의 전단 균질화 연구)

  • 유재웅
    • Polymer(Korea)
    • /
    • v.27 no.5
    • /
    • pp.413-420
    • /
    • 2003
  • Fluorescence microscope technique was employed for the characterization of phase separation behavior of a 4-chloro-7-nitrobenzofurazan labeled polystyrene (PS) / polybutadiene (PB) blend in dioctyl phthalate under steady shear. It was confirmed that the fluorescence microscope images reflect the real phase morphology by comparing with the images of phase contrast microscope. Comparing the fluorescence intensities from the phase separated domain (PS rich) and continuous phase (PB rich), the composition difference between these two phases were deduced. The observed shear dependence of compositional change is then used to confirm that the phase diagram is indeed shifted under the steady shear.

양전자 소멸 측정법에 의한 형광물질의 결함 연구

  • Lee, Jong-Yong;Gwon, Jun-Hyeon;Bae, Seok-Hwan
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.45.1-45.1
    • /
    • 2009
  • 본 연구에서는 BaSrFBr:Eu 형광물질의 결함 농도 분석을 시도하였다. 또한 동시 계수 방법과 Fast -Slow - Coincidence 시스템으로 구성한 양전자 수명 측정법을 통하여 에너지의 변화에 따른 양성자 조사에 의한 시료 결함에 따른 동시 계수 도플러법과 양전자 수명의 변화를 측정 하였으며, SRIM 시뮬레이션을 통한 에너지에 따른 양성자 투과 깊이의 변화를 연구하였다.

  • PDF

An Improved Laser-Induced Fluorimetry for Assay of Uranium in Urine (레이저 유발형광법을 이용한 우라늄 작업자의 뇨 형광 분석)

  • Lee, Sang-Mok;Shin, Jang-Soo;Kim, Cheol-Jung
    • Nuclear Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.255-258
    • /
    • 1993
  • A method for analysis of trace uranium in urine sample was studied using a time-resolved $N_2$-laser-induced fluorimetry. The Fluran solution was found to be efficient to mask the chloride ions which are known to quench uranium fluorescence in the fluorimetric assay of uranium in urine. This improved method made the sample preparation much simpler than other conventional ones. The fluorescence intensities at 1% urine mixture with 10% Fluran aqueous solution showed good linearities in the concentration range of 10-500 ppb(before dilution).

  • PDF

Feasibility of Granular Activated Charcoal as a Detector in Fluorescent Tracer Tests (입상 활성탄을 이용한 형광물질 추적자시험 적용성 연구)

  • Lee, Jin-Yong;Hwang, Hyoun-Tae;Yi, Myeong-Jae;Kim, Yong-Cheol;Yum, Byoung-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.4
    • /
    • pp.86-93
    • /
    • 2007
  • In recent tests using tracer have been frequently conducted by fluorescent tracers. In this study, granular activated charcoal (GAC) as a detector for the fluorescent tracers (rhodamine WT and uranine) was investigated through laboratory and field tests. In the laboratory tests, tracer concentrations of rhodamine WT and uranine determined by the GAC were slightly different from those of standard solutions but they were excellent in linearity. Results show that GAC is excellent as tracer detector when concentration of the fluorescent tracers is greater than 10 & micro; g/L whileas no obvious differences in mixed solutions of the two tracers due to interferences. Compared to conventional methods of water sampling, field results shows a high potential of GAC as a tracer in the field. Our results also show that wet analysis is better for the lower concentrations of tracers whileas dry analysis is good for high concentrations of tracers. This study demonstrates that fluorescent tracer detection using the GAC is very useful and economical for a hydraulic connection between target areas and very longer period of the tracer test.

Inorganic Nanoparticles for Near-infrared-II Fluorescence Imaging (근적외선-II 형광 이미징을 위한 무기 나노입자)

  • Park, Yong Il
    • Applied Chemistry for Engineering
    • /
    • v.33 no.1
    • /
    • pp.17-27
    • /
    • 2022
  • Fluorescence imaging is widely used to image cells or small animals due to its high temporal and spatial resolution. Because conventional fluorescence imaging uses visible light, the penetration depth of light within the tissue is low, phototoxicity may occur due to visible light, and the detection sensitivity is lowered due to interference by background autofluorescence. In order to overcome this limitation, long-wavelength light should be used, and fluorescence imaging using near-infrared-I (NIR-I) in the region of 700~900 nm has been developed. To further improve imaging quality, researchers are interested in using a longer wavelength light, near-infrared-II (NIR-II) ranging from 1000 to 1700 nm. In the NIR-II region, light scattering is further minimized, and the penetration depth of light in the tissue is improved up to about 10 mm, and autofluorescence of the tissue is reduced, enabling high sensitivity and resolution fluorescence imaging. In this review, among various NIR-II fluorescence imaging probes, inorganic nanoparticle-based probes with excellent photostability and easily tunable emission wavelength were described, focusing on single-walled carbon nanotubes, quantum dots, and lanthanide nanoparticles.

Dyeing for High-Visibility on Recycled Polyester Fabrics (재생 PET 소재에 대한 Hi-Vis. 염색가공 기술 적용)

  • Hong, Jin-Pyo;Yoon, Seok-Han;An, Hun-Ju
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2012.03a
    • /
    • pp.120-120
    • /
    • 2012
  • 최근 주야간 산업현장의 근로자 안전성을 위한 식인성이 우수한 Hi-vis. 염색이 work-wear에 많이 적용되고 있으며, Hi-vis. 염색에서의 형광색상은 차별화된 패션성을 원하는 소비자에게도 레져용, 아웃도어용, 캐쥬얼 등에 많이 사용되고 있다. 형광염료는 주로 안료나 PET용 분산염료로의 전개가 일반적이며, 예전에는 형광안료 코팅을 통한 필름이나 테이프 등이 많이 사용되었으나 최근에는 의류에 직접 염색공정을 적용하는 기법으로 형광분산염료가 많은 용도에 적용된다. 이러한 고가시 산업용 work-wear는 주간에는 선명한 색상을 띄며, 야간에는 빛나는 재귀 반사의 성능을 지니며 대표적인 형광컬러는 Yellow, Red-Orange, Red, Yellow-Orange, Pink, Green, Yellow-Green 등 색상이 있다. 고가시성 안전의류(High Visibility Warning Clothing) 기준의 색도 좌표 및 일광 견뢰도 등 성능을 만족해야 하며, 대표적인 규격은 유럽의 EN-471로 일광, 마찰, 세탁, 땀, 드라이클리닝, 염소 등 견뢰도에 대한 각각의 합격기준이 있으며, 색도 및 형광팩터 등의 기준에 맞는 염색처방이 필요하다.

  • PDF

Screening of Eu3+-and Tb3+-Activated Phosphors for PDP in the System of CaO-Gd2O3-Al2O3 (CaO-Gd2O3-Al2O3계에서의 PDP용 Eu3+와 Tb3+ 활성 형광체의 탐색)

  • Park, Sang-Mi;Kim, Chang-Hae;Park, Hui-Dong;Jang, Ho-Gyeom;Park, Jun-Taek
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.4
    • /
    • pp.336-345
    • /
    • 2002
  • In this study, we have screened $Eu^{3+}$- and $Tb^{3+}$-activated candidate phosphors for PDP in the sys-tems of CaO-Gd$_2$O$_3$-Al$_2$O$_3$ by combinatorial chemistry and investigated the synthetic temperature, optimum com-position and luminescent properties about the candidate phosphors. To construct the emission intensity library by VUV PL, we have synthesized 210 different compositional samples using a polymerized-complex method. Good luminescent samples were identified by X-ray diffraction method. $Ca_$\alpha$$G$d_{0.95-$\alpha$-$\beta$}Al_$\beta$O_$\delta$$ : Eu(0.02< $\alpha$+$\beta$ <0.04) phos-phors screened as a red phosphor have good color purity than commercial phosphor. In the candidate phosphors of CaGdAl$_3O_7$ : Tb, Ca$Al_{12}O_{19}$ : Tb, Gd$_4$Al$_2O_9$ : Tb, and Gd$_3Al_5O_{12}$ : Tb CaGdAl$_3O_7$ : Tb, and Ca$Al_{12}O_{19}$ : Tb have shorter decay time than commercial phosphor.