• Title/Summary/Keyword: 입자 가시화

Search Result 291, Processing Time 0.022 seconds

Visualization of rotational flow using SPIV in cylindrical tank (Stereoscopic PIV 속도장 측정기법을 이용한 원통내의 회전 유동장 측정)

  • Choi Jong Ha;Yang Kun Su;Gowda B. H. L.;Sohn Chang Hyun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.44-47
    • /
    • 2004
  • Vortexing might occur during draining from tanks which reduces the rate of outflow. This phenomenon has practical relevance in the fuel feed system in space vehicles and rockets. Due to environmental disturbances rotational motion can be generated in the liquid-propellant tank, which in turn can affect the rate of outflow to the engines. The phenomenon is initialized by rotating the fluid In the experimental tank. The dip quickly develops into a vortex with an air core, which extends to the bottom port, reducing the effective cross-sectional area of the drain outlet and consequently the flow rate. Flow characteristics are investigated using SPIV(Stereoscopic Particle Image Velocimetry) method.

  • PDF

An experimental analysis of the fluid flow in an automobile HVAC system using a PIV technique (PIV기법을 이용한 차량용 공조 시스템 내부유동에 대한 실험적 연구)

  • Ji, Ho-Seong;Kim, Bo-Ram;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.92-96
    • /
    • 2007
  • Internal flow characteristics for an automobile HVAC have been investigated using a high-resolution PIV technique. The PIV system consists of a 2-head Nd:YAG laser(125 mJ), a high-resolution CCD camera($2K\;{\times}\;2K$), optics and a synchronizer. An automobile HVAC module was used directly. Only the casing was remodeled transparently for capturing flow image and laser sheet beam illumination. Time-averaged velocity field were measured in three temperature control mode. For three temperature control modes, the internal flow characteristics for an automobile HVAC system were evaluated from PIV results..

  • PDF

An Experimental Study on Flow Structure inside a Display Cooler Using PIV Techniques (PIV기법을 이용한 전시용 냉장기의 내부 유동장 측정)

  • Park, Cheol-Woo;Baek, In-Je
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.2
    • /
    • pp.48-55
    • /
    • 2007
  • Flow structure inside a refrigerating compartment of a scale-down display cooler model was investigated experimentally by using PIV (particle image velocimetry) method, a reliable velocity field measurement technique, in the present study. In addition, we also carried out flow visualization regarding flow structure and particle movement inside a display cooler by using a tracer method. As a result, the mean velocity field measurement shows a large scale vortical flow structure inside a refrigerating compartment due to strong entrainment flow, going through a base plate open gaps.

Aerodynamic Characteristics of Delta Wing According to Leading Edge Geometries (앞전 형상에 따른 삼각 날개의 공력 특성)

  • Jin, Hak-Su;Kim, Sung-Cho;Kim, Jeong-Soo;Choi, Jong-Wook
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.2
    • /
    • pp.56-63
    • /
    • 2007
  • Flow visualization and aerodynamic characteristics of delta wings with two different leading edge geometries are investigated by PIV system and wind tunnel balance when the Reynolds number is about based on the freestream velocity and the root chord length. Delta wing models have 65-deg swept angle, and the leading edge shapes are divided into round- and sharp- type. The experimental results indicated that the leading-edge vortex strength and aerodynamic coefficient in the round leading edge are stronger and more, respectively than those in the sharp one. Therefore the flow interactions between vortices and the boundary layer are more desirable or more rapidly swirled in the round-type leading edge.

Flow Visualization and PIV Measurement of Multiphase Flow in Highty Viscous Liquid (고점성 유체 내부에서의 다상유동장 가시화 및 PIV 측정)

  • Kim, Hyun-Dong;Ryu, Seung-Gyu;Kim, Kyung-Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.48-54
    • /
    • 2006
  • A visualization study of flow characteristics in a mixer using multi-nozzle bubbling was performed. The mixer is filled with liquid glycerin (dynamic viscosity = $1000mPa{\cdot}$ s at $25^{\circ}C$) and convective mixing is induced by air bubbles generated from 9 orifices installed on the bottom of the mixer. To visualize the flow field, PIV (Particle Image Velocimetry) system consisting of 532nm Nd:YAG laser, $2k\times2k$ CCD camera and synchronizer is adopted. The bubbles generated with uniform size and frequency form bubble stream, and bubble streams rise vertically without interaction between bubble streams. Mixing efficiency is affected by the height of bubbler and the effective height of bubbler is 20mm from the bottom of the mixer.

  • PDF

PIV Measurement of Flow Inside an Automotive HVAC Module with Varying Temperature Baffle (온도조절 격판 변화에 따른 차량용 HVAC 내부 유동의 PIV속도장 측정 연구)

  • Ji, Ho-Seong;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.6 no.1
    • /
    • pp.27-33
    • /
    • 2008
  • Air flow inside an automotive HVAC module has been investigated using a high-resolution PIV technique with varying the temperature operation mode. The PIV system consists of a 2-head Nd:YAG laser (125 mJ), a high-resolution CCD camera (2K$\times$2K), optics and a synchronizer. A real automotive HVAC module was used directly under real operating condition. Some casing parts of the HVAC module were replaced with transparent windows for capturing clear flow images with laser light sheet beam illumination. Time-averaged velocity fields were obtained for two different temperature control modes. Flow characteristics of the air-conditioned air flow inside the automotive HVAC system for the two temperature baffle conditions were evaluated.

A visualization study on flow characteristics of sweeping jet impinging on flat plate (Sweeping Jet의 평판 충돌 유동 특성에 관한 가시화 연구)

  • Kim, Sang Hyouk;Kim, Hyun Dong;Kim, Kyung Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.3
    • /
    • pp.16-25
    • /
    • 2018
  • PIV experiments were carried out to visualize the velocity distribution of the sweeping jet impinging onto a flat plate and kinematic behavior of the jet from the fluidic oscillator. Two parameters such as four different Re cases and four different jet-to-wall distances were examined. Time-resolved two dimensional PIV measurements were performed for both streamwise and normal planes respect to the jet axis. Ensemble averaged and phase averaged velocity fields were obtained for the tested range of parameters. The sweeping frequency of the jet increases linearly with increase of Re. The kinetic energy of the sweeping jet decreases as the distance from the jet to the impinging plate increases. In addition, turbulence flow is generated due to the swinging motion of sweeping jet, and various vortices such as primary and secondary vortex are observed near the impinging wall.

Generation and ignition of micro/nano - aluminum particles using laser (레이저를 이용한 마이크로/나노 알루미늄 입자 생성과 점화)

  • Lee, Kyung-Cheol;Yoh, Jai-Ick
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.429-434
    • /
    • 2012
  • Ignition delay of micro/nano aluminum particles is caused by aluminum oxide shell. The method of minimizing this ignition delay is proposed in the study. Generating and heating of particles are processed at the same time. As soon as heated particles are produced, they immediately contact with oxygen. Chemical reaction is induced on the contact surface instead of crystallization of oxide shell. Finally particles are ignited. Aluminum particles are generated by laser ablation on an aluminum plate using Nd:YAG pulse laser. Injected particles are confirmed through visualization of particles using scattering method. $CO_2$ continuous laser supplies heat to aluminum plate and generated particles. Trace of burning particles is observed in the experiment.

  • PDF

Quantitative Visualization of Outlet Flow of the Centrifugal Blower (원심 블로어 출구 유동의 정량적 가시화 연구)

  • Tu, Xin Cheng;Kim, Sung-Jun;Park, Seung Ha;Kim, Hyoung-Bum
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.1
    • /
    • pp.25-29
    • /
    • 2014
  • The outlet flow of the centrifugal blower were quantitatively visualized using particle image velocimetry. Because the centrifugal blower is one of the key parts of electric vehicle battery cooling system, the quantitative information of centrifugal blower is necessary to design and optimize the cooling system. The effect of different inlet flow condition to the outlet flow was investigated in this study. Two different inlet ducts were used. One is the straight inlet and the other is a bended one. The results clearly showed the outlet flow asymmetry in both inlet ducts. When the blower has the bended inlet, the flow rate decreases due to the increase of the head loss.

Fuel Spray Characteristics of the APU Gas Turbine Combustor under high speed air flow conditions (APU 가스터빈 연소기내의 고속공기유동에 따른 연료 분무특성 연구)

  • Kim, Bo-Ra-Mi;Choi, Chea-Hong;Rhee, Dong-Ho;Choi, Seong-Man
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.285-288
    • /
    • 2009
  • In order to understand spray characteristics with inflowing air from the compressor in the APU gas turbine combustor, we performed spray visualization test by using ND-Yag Laser sheet beam. The sector combustor which size is 1/6 of the real combustor was manufactured. Turbo blower is used as an air supplying device to simulate gas turbine air flow condition. In the case of 75 m/s combustor inlet air flow condition, spray angle way increased and dispersed widely than without airflow condition.

  • PDF