• Title/Summary/Keyword: 입사방향

Search Result 438, Processing Time 0.032 seconds

Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters (유방촬영술에서 유리선량계를 이용한 납치마의 선량차폐 효과 측정)

  • Yu, Su-Jeong;Lim, Sangwook;Ma, Sun Young;Seo, Sun-Youl;Kim, Young-Jae;Kang, Young-Nam;Keum, Ki Chang;Cho, Samju
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.93-98
    • /
    • 2015
  • The purpose of this study is to see the usefulness of lead apron for critical organs near the breast under examining. For clinical experiment, 30 female volunteers who agreed to their participation in the experiments, were chosen and divided into two groups, 15 in group A and 15 in group B respectively. group A is to see whether each side of breast under mammography affects to other side glandular on the critical organs is same, because it is not allowed to scan the both breast for same person or to scan repeatedly. Group B is to see the effectiveness of lead apron during the mammography of right breast. Glass dosimeters were placed on the thyroid, the contralateral breast, and lower abdomen where near the breast during examining. The average glandular doses on the surface in mammography of the thyroid gland, the contralateral breast, the lower abdomen were 0.0692 mGy, 0.6790 mGy, and 0.0122 mGy, respectively, which was an extremely low level of glandular dose. In group B, as to the thyroid gland, average dose was decreased from 0.0922 mGy to 0.0158 mGy. The average dose of contralateral breast was decreased from 0.8575 mGy to 0.0286 mGy. The average doses of lower abdomen was decrease 0.0150 mGy to 0.0173 mGy. As to the lower abdomen, dose decreased from 0.0150 mGy before the use of an apron down to 0.0173 mGy after the use. As p-value was under 0.05, statistically significant difference was observed between the two groups. Wearing an apron can have the protective effects on the thyroid gland up to 20 times lower than not wearing one. Besides, it is also necessary to protect the other breast during the examination by wearing one.

Study of silk lousiness (I) (견사 Lousiness에 대한 연구 (I))

  • 최병희;김낙정;박광의;남중희
    • Journal of Sericultural and Entomological Science
    • /
    • v.3
    • /
    • pp.1-11
    • /
    • 1963
  • This treatise is to set up a fundamental condition of checking silk lousiness and to set up a new improving method of cocoon bave lousiness after super refining treatment. It is also studied whether silk lousiness can be eliminated through the observation of the silk gland, or the lousiness can be able to improve through such a study. The conclusions obtained in this paper are as follows. 1. Silk lousiness is able to be observed most properly when the light direction and the fiber direction are parallel in plan view of the silk cloth and the greater the angle between them is, the less the lousiness is observed. When, however, the angle is greater than some specific angle(30$^{\circ}$), no more lousiness is observed. This specific angle is named by the author as Lousiness Horizontal Critical Angle. 2. Silk lousiness can be observed when the angle of light incidence against the silk cloth is six degrees, while the larger the angle is, the less the lousiness is observed. When, however, the angle is greater than same specific angle(45$^{\circ}$) the lousiness disappears. Such a specific angle is named by the author as Lousiness Vertical Critical Angle. 3. The best textile composition to decrease lousiness defect is plan weave, while twill and satin weave show more lousiness with the same silk fiber. 4. Lousiness was classified as Lousiness A, B, ana C of which A was the general lousiness, B was the group type, and C was the glucose type and the standard photographs for the lousiness grading of these types were prepared. 5. The proper soap-refining hours of silk for lousiness test was eight hours. 6. The greater the difference of fiber diameter between the cocoon single bave and the splitend was, the more lousiness was composed. The normal splitends were measured as 1/4-1/5 of the main fiber. 7. The lousiness was found at the cocoon shape ends more than other parts, and found at the middle cocoon layer than other layer which was imagined to be as a result of poor uniform bave spinning of silk worm. 8. Female cocoon had more lousiness than the male cocoon. 9. It was found that there was a great possibility to have the splitends through the observation of the anatomical silkgland, and the author reached a conclusion that the lousiness can be improved to a certain degree only by the elimination of abnormal silk gland from the breeding aspects. 10. The cocoon bave of the offspring after super refining lousiness test and selection showed more improved lousiness defect than that of the parents.

  • PDF

Characteristic of Wave Diffraction and Reflection for Irregular Waves in SWASH Model Around Small Port Structures (소규모 항만 구조물 주변에서 불규칙파에 대한 SWASH 모형의 반사 및 회절)

  • Kwon, Kyong Hwan;Park, Chang Wook;Park, Il Heum;Kim, Jong Hoon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.6
    • /
    • pp.468-477
    • /
    • 2019
  • The numerical model of Boussinesq approximation, which is mainly used for evaluating the port calmness due to the irregular waves, has a limit of applicability of lattice size in ports such as marinas with narrow port openings of around 30m. The SWASH model controls the partial reflection according to the depth, porosity coefficient and structure size when applying the reflected wave incident on the structure and terrain. In this study, the partial reflection evaluation at the front of the structure according to the bottom shape and the shape of the structure are examined. In order to evaluate the reproducibility of the model due to the diffraction waves entering the term, the area of incidence at right angles and inclination of the structure is constructed and compared with the diffraction theory suggested by Goda et al. (1978). The experimental results of the sectional structure reflectances calculated as the depth mean show reflectances similar to the approximate values of the reflectances presented by Stelling and Ahrens (1981). It is considered that the reflected wave is well reproduced according to the control of the reflected wave at the boundary and the shape and topography of the structure. Compared with previous studies to examine the diffraction of the wave incident from the breakwater opening, the wave incidence angle and the shape of the diffraction wave are very similar to the theoretical values, but both oblique and rectangular incidence In the case where the direction concentration is small, the diffraction degree is underestimated in some sections with the crest ratio of 0.5 to 0.6.

Wave Simulation for Submarine Cable Route of Southwest Sea Offshore Wind Farm Using the SWAN Model (SWAN 모델을 이용한 서남해 해상풍력단지 해저케이블 경과지의 파랑 수치모의)

  • Ryu, Hwang-Jin;Kim, Sang-Ho;Kwoun, Chul-Hui;Cho, Kwang-Woo;Maeng, Jun-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.5
    • /
    • pp.583-590
    • /
    • 2015
  • Submarine cable installation is essentials for grid connection between existing power grid and newly produced electricity which will be from offshore wind farm in Southwest sea area of Korea. Especially, submarine cable route and protection method is designed in order to ensure the economical efficiency, workability and stability of submarine cable installation. On this paper, we will give the basic information about the submarine cable route and protection method of offshore wind farm which will be built in Southwest sea area of Korea. For this, we have a numerical simulation at high and low tide based on the third-generation wave model SWAN(Simulating WAves Nearshore) using the long term wave data from Korea Institute of Ocean Science and Technology(KIOST). The results of the study, year mean Hs is 1.03m, Tz is 4.47s and dominant wave direction is NW and SSW When the incident wave direction is NW(Hs: 7.0 m, Tp: 11.76s), the distribution of shallow water design wave height Hs was calculated about 4.0~5.0m at high tide and 2.0~3.0m at low tide. When the incident wave direction is SSW(Hs: 5.84 m, Tp: 11.15s), the distribution of shallow water design wave height Hs was calculated about 3.5~4.5m at high tide and 1.5~2.5m at low tide. The wave direction on a dominant influence in the section of longitude UTM 249749~251349(about 1.6 km) and UTM 251549~267749(about 16.2 km) in the submarine cable route are each NW and SSW. Prominently, wave focusing phenomenon appears between Wi-do and Hawangdeung-do, in this sea area is showing a relatively high wave hight than the surrounding sea areas.

Inspection of the Nuclear Fuel Rod Deformation using an Image Processing (영상처리를 이용한 핵연료봉의 변형 검사)

  • Cho, Jai-Wan;Choi, Young-Soo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.1
    • /
    • pp.91-96
    • /
    • 2010
  • In this paper, a deformation measurement technology of the nuclear fuel rod is proposed. The deformation measurement system include high definition CCD or CMOS image sensor, lens, semiconductor laser line beam marker, and optical & mechanical accessories. The basic idea of the deformation measurement is to illuminate the outer surface of the fuel rod with collimated laser line beam at an angle of 45 degrees or higher. The relative motion of the fuel rod in the horizontal direction causes the illuminated laser line beam to move vertically along the surface of the fuel rod. The resulting change of laser line beam position in the surface of the fuel rod is imaged as the parabolic beam in the high definition CCD or CMOS image sensor. From the parabolic beam pattern, the ellipse model is extracted. And the slope of the long and the short axis of the ellipse model is found. The crossing point between the saddle point of the parabolic beam and the long & short axis of the ellipse model is taken as the feature of the deformed fuel rod. The vertical offset between feature points before and after fuel rod deformation is calculated. From the experimental results, $50\;{\mu}m$ inspection resolution is acquired using the proposed method, which is three times enhanced than the conventional criterion ($150\;{\mu}m$) of the guide for the inspection of the nuclear fuel rod.

Response Function of HPGe Detector using $^{23}Na$(p, $\gamma$)$^{24}Mg$ and $^{27}Al$(p, $\gamma$)$^{28}Si$ Reaction ($^{23}Na$(p, $\gamma$)$^{24}Mg$$^{27}Al$(p, $\gamma$)$^{28}Si$반응을 이용한 HPGe 검출기의 응답함수)

  • Park, Sang-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.85-90
    • /
    • 2010
  • In the present work, peak relative efficiency for the energy was obtained and response function was worked out. This study was carried out using the high resolution high efficiency HPGe detector(diameter 78.7 mm, length 86.5 mm) and NaI(Tl) detector for anti-compton. The anti-coincidence of the signals from the two detectors could be used to lessen the Compton effect signal; thus, the $\gamma$-ray energy resolution could be improved. The $\gamma$-ray spectrum was measured at $55^{\circ}$ to the direction of the incident proton beam. Reaction spectrum was obtained from the $^{23}Na$(p, $\gamma$)$^{24}Mg$ reaction at $E_p$ = 1424 keV and $^{27}Al$(p, $\gamma$)$^{28}Si$ reaction at $E_p$ = 992 keV. To accelerate the incident proton which creates the (p, $\gamma$) capture reaction, the 3 MeV Pelletron accelerator at the Tokyo Institute of Technology was used. Response function was worked out by a noble technique. We worked out a response function from 1.2 to 9.4 MeV at intervals of 0.75 MeV.

An Analytical Solution of Flow and Progressive Wave-Induced Residual Pore Water Pressure in Seabed (흐름과 진행파에 의한 해저지반 내 잔류간극수압의 해석해)

  • Lee, Kwang-Ho;Kim, Dong-Wook;Kang, Gi-Chun;Kim, Do-Sam;Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.7
    • /
    • pp.13-28
    • /
    • 2015
  • This study extended the Lee et al.'s (2015a) solution which improved the existing analytical solution for prediction of the residual pore water pressure into progressive wave and flow coexisting field. At this time, the variation of incident wave period and wave length should be incorporated to Lee et al.'s (2015a) analytical solution, which does not consider flow. For the case of infinite thickness, the new analytical solution using Fourier series was compared to the analytical solution using Laplace transformation proposed by Jeng and Seymour (2007). It was verified that the new solution was identical to the Jeng and Seymour's solution. After verification of the new analytical solution, the residual pore water pressure head was examined closely under various given values of flow velocity's magnitude, direction, incident wave's period and seabed thickness. In each proposed analytical solution, asymptotic approach to shallow depth with the changes in the soil thickness within finite soil thickness was found possible, but not to infinite depth. It is also identified that there exists a discrepancy case between the results obtained from the finite and the infinite seabed thicknesses even on the same soil depth.

GLAD법으로 증착한 Smart window용 WO3와 TiO2의 전기변색적 특성 비교

  • Kim, Seong-Han;Song, Pung-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.198-198
    • /
    • 2015
  • 전기변색재료는 전압을 인가하였을 때 전계방향에 따라 가역적으로 색이 변화하는 재료를 말한다. 스마트윈도우용 전기 변색재료는 지속적으로 전기를 가해줄 필요 없이 한번 변색되면 색이 지속되는 특징을 가지므로 에너지 효율적으로 우수하여 태양열 차단 창호나 디스플레이 분야에 응용될 것으로 기대된다. 이러한 전기 변색재료에는 산화형 전기 변색 재료, 환원형 전기 변색 재료가 있는데 이중 가장 널리 연구되고 있는 재료는 환원형 전기변색재료이다. 대표적인 재료로 $WO_3$가 쓰이는 데 이는 전기 변색적 특성이 우수하고 또한 내구성이 다른 재료에 비해 우수하다는 장점 때문이다. 그러나, 상용화를 위해서는 내구성의 개선이 요구되고 있다. 한편, $TiO_2$는 안정성이 매우 뛰어나지만 전기변색적 특성이 $WO_3$에 비해 낮은 점이 지적되고 있다. 이러한 $WO_3$$TiO_2$ 박막은 스퍼터링 또는 sol-gel법 등으로 제작되고 있는데, 일반적으로 스퍼터링의 경우 치밀한 박막이 형성되기 때문에 Porous 한 박막을 얻기 힘들다. 따라서 본 연구에서는 기판에 입사하는 스퍼터 입자들의 각도를 조절하여 shadowing 효과로 인해 박막의 구조가 porous해지는 Glancing angle deposition을 도입하였다. 이러한 증착법을 이용하여 $WO_3$$TiO_2$를 각도를 조절하여 증착하고 $TiO_2$$WO_3$ 박막의 특성을 비교하여 본다. 두께 300 nm를 가지는 $WO_3$$TiO_2$ 박막은 GLAD RF 마그네트론 스퍼터링법을 이용하여 Corning glass(corning E-2000)기판 위에 증착하였다. 기판 입사 각도는 $0^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$로 증착하였고 직경 3 in의 $TiO_2$, $WO_3$ 타겟을 사용하였다. 또한 스퍼터링 파워는 400 W, 작업압력 1.0 Pa, 그리고 스퍼터링 가스는 O2/Ar+O2 유량 10%에서 30%로 증착을 상온에서 진행하였다. 전기화학적 특성을 평가하기 위하여 $TiO_2$$WO_3$ 박막을 100 nm 두께의 ITO/glass 위에서 증착하였다. 박막의 미세구조는 XRD와 SEM을 통해 확인하였고, 전기화학적 특성은 Ar 분위기의 Glove box안에서 parstat 2273을 통해 측정하였다. 전해질은 1 M $LiPF_6/PC$로 진행하였고, 대향 전극는 Pt전극을, 참고 전극은 칼로멜 전극을 사용하였다. Potential 범위는 2 V에서 4 V로 진행하였고, scan rate는 50 mV/s로 측정하였다. 투과도는 UV/VIS spectrometer로 측정하였다. 전기변색 특성의 상관관계 및 에 대해서는 학회 당일 발표할 예정이다.

  • PDF

Fish length dependance of acoustic target strength for large yellow croaker (부세에 대한 음향반사강도의 체장 의존성)

  • 강희영;이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.3
    • /
    • pp.239-248
    • /
    • 2003
  • This paper was conducted as an attempt in order to construct the data bank of target strength for acoustic estimation of fish length in the coastal waters of Korea. The fish length dependence of acoustic target strength for 13 large yellow croakers (Pseudosciaena crocea) at 75 kHz was investigated and the prediction of the target strength by using the Kirchhoff-Ray Mode model (KRM model) was compared with target strength measurements. The results obtained are summarized as follows; 1. In the averaged target strength pattern for 13 large yellow croakers the maximum target strength was -35.13 dB at $-13.35^{\circ}$ on a tilted angle. 2. The relationship between fork length(L, cm) and averaged target strength(TS, dB) was expressed as follows; TS=23. 76log (L) -73.45 (r=0.47) TS=20log(L) -67.35 From this result, the conversion coefficient was -73.45 dB and 6.1 dB lower than the coefficient -67.35 dB where the value of the slope of the regression equation is forced to be 20. 3. Averaged target strength and a length conversion coefficient derived from a target strength histogram for 13 large yellow croakers of mean length 25.59 cm were -41.23 dB, -69.72 dB, respectively. 4. In the range of $$2;{\ll} L (fish length /{\lambda}(wave length);{\ll}40$$, the prediction of the averaged target strength by the KRM model increased gradually with the increasing of $L/{\lambda}$ and was lower than the measured target strength.

An Experimental Study of Sediment Transport Patterns behind Offshore Structure (외해 구조물 배후의 표사이동에 관한 실험적 연구)

  • Shin Seung-Ho;Hong Keyyong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.7 no.4
    • /
    • pp.207-215
    • /
    • 2004
  • Recently, securing a vast land in the land region becomes more difficult and efforts to seek its alternation in the sea area have been increased. As a consequence, the coastal region has been faced to extensive beach erosion problems. In planning offshore structures such as artificial islands, it is necessary to forecast the influence of the structure construction exerting on the beach erosion of the adjacent coast. In the present study, the sediment movement pattern behind offshore structure was examined through a series of three dimensional movable bed experiments, so as to develop the numerical model which forecasts morphological change including beach erosions. The experimental results reveal that the sediment movement patterns of the beach line side and the depth region are separated at a certain boundary line. In details, at the beach side including swash zone the sediment movement becomes dominant, which is governed by a relation between depth contours and incident wave directions, while at the depth region the bed load and suspended load due to the orbit motion of waves are carried by nearshore currents, and both movements are clearly separated at a specified boundary that is related to partial standing wave from the beach. It is expected that these results can be effectively used for verification of a numerical model on morphological change of the coast.

  • PDF