Complications of implants confronting the extruded posterior teeth (정출된 구치와 대합되는 임플란트의 합병증)

  • Jung, Yeon-Wook;Lee, Su-Yeon;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.232-241
    • /
    • 2020
  • Purpose: This study investigated the complications and patterns of implants that confronted with the extruded natural teeth. Materials and Methods: Among patients who received implant treatment between 2006 and 2018 at Chosun University Dental Hospital, only implants that had a maintenance period of at least 5 years and that both implants and confronting natural teeth could be measured and compared on a radiograph were selected. They were divided into two groups. Group 1, experimental group consisted of Implants confronting the extruded natural posterior teeth (n = 167: maxilla (Group 1max) = 92, mandible (Group 1man) = 75) and Group 2, control group consisted of Implants confronting the normal natural posterior teeth (n = 656: maxilla (Group 2max) = 272, mandible (Group 2man) = 384). Results: The incidence of complications between Group 1 and Group 2 was statistically significant. In particular, there was a statistically significant difference between the frequency of marginal bone loss and the amount of marginal bone loss. Conclusion: The extruded natural tooth may cause more frequent complications including bone resorption in the opposing implant.

Success rate and marginal bone loss of Osstem USII plus implants; Short term clinical study (Osstem USII plus 임플란트의 단기간 성공률 및 변연골 흡수량 평가)

  • Kim, Sun-Keun;Kim, Jee-Hwan;Lee, Keun-Woo;Cho, Kyoo-Sung;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.206-213
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the clinical value of Osstem$^{(R)}$ USII plus system implants. Clinical and radiographic data were analyzed for 88 implants placed and functionally loaded for a 12 month period at the Yonsei University Dental Hospital. Materials and Method: Based on the patient's medical records, clinical factors and their effects on implant marginal bone resorption, distribution and survival rate were analyzed. The marginal bone loss was evaluated at implant placement and during a 6 to 12 months functional loading period. The independent sample t-test was used to evaluate the interrelationship between the factors (${\alpha}$=0.05), and one way repeated measures ANOVA was used to compare the amount of marginal bone resorption. Results: The cumulative survival rate for 88 implants was 100%. The marginal bone resorption from implant placement to prosthetic delivery was 0.24 mm and the average marginal bone resorption from prosthetic delivery to 12 months of functional loading was 0.19 mm. The total average bone resorption from implant placement to 12 months of functional loading was 0.43 mm. There were no statistically differences in the amount of marginal bone resorption when implants were placed in the maxilla or the mandible (P>.05), however, implants placed in the posterior areas showed significantly more marginal bone loss than those placed in the anterior areas (P<.05). Conclusion: Based on these results, the short term clinical success rate of RBM surface treated external connection domestic implants showed satisfactory results and the marginal bone loss was in accord with the success criteria of dental implants.

Implant prosthesis for fully edentulous patients using intra-oral scanning and abutment merging technique: A case report (무치악 환자에서 구강 스캔과 지대주 중첩을 이용한 임플란트 보철수복 증례)

  • Hwang, Chan-Hyeon;Jeong, Seung-Mi;Kim, Yong-Jun;Kim, Kyeong-Hee;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.61-70
    • /
    • 2017
  • In this case, the impression surface of the existing denture was scanned and was inverted three-dimensionally to express the residual ridge form. Implant planning was performed on the superimposed data of the CT with the scanned image of the denture with radiopaque markers attached. At the day of surgery, customized abutments fabricated in accordance with the form of the gingival margin were linked with fixtures and temporary restorations were set. In the process of fabricating the final prosthesis after the osseointegration of implant fixture, the intraoral scan images at abutment level were merged with images of the abutments scanned and stored before implant surgery. By fabricating the final prosthesis with the abutments obtained by merging can increase the marginal fitness of the final prosthesis and simplify the clinical process.

Retrievable SCP (screw-cement prosthesis) implant-supported fixed partial dentures in a fully edentulous patient: a case report (완전 무치악 환자에서 나사-시멘트 보철물(SCP: screw-cement prosthesis)을 이용한 임플란트 보철 수복 증례)

  • Kim, Joo-Hyeun;Yun, Bo-Hyeok;Jang, Jung-Eun;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.318-323
    • /
    • 2012
  • Implant prostheses were classified into screw-retained prosthesis and cement-retained prosthesis by their method of retaining, and there is screw and cement retained implant prosthesis (SCRP) which has been made reflecting the strengths of these two. The advantages of the SCRP technique are easy retrievability and passive fit of implant prostheses. However, the occlusal screw holes of implant prostheses can be thought as a disadvantage with respect to esthetics and occlusion. Inappropriately positioned implants also limited the use of the SCRP technique. The present study is reporting about the case where nine implants (US II, OSSTEM, Seoul, Korea) were placed in maxilla and eight in mandible respectively in fully edentulous patients. Then, the cement-retained prosthesis was applied for the part in which the screw hole positioned improperly, and screw-retained prosthesis for properly positioned implants so that the combined screw-cement prosthesis has been produced where the satisfying result has shown in both function and esthetics. Three-year follow-up has been done for the patient.

Esthetic Root Coverage for Gingival Recession (심미적인 결과를 얻기 위한 치근 피개술)

  • Ahn, MyungHwan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.4-16
    • /
    • 2017
  • In dental esthetics, soft tissue plays an important part, probably very large portion of it. A clear understanding of the periodontal tissues and its management around teeth and implants help us to develop concepts for a modern dental treatment that addresses the needs of demanding patients in regard of esthetics and durability. When we talk about esthetic, we can say that one of the most important element is a harmonization with gingiva (soft tissue) called 'Pink Esthetic' As for the pink esthetics, gingival line(contour) takes most of the influence on esthetic result; it consists of labial gingival level, interproximal papilla height, and a line that connects them. In the gingival recession, labial gingival level and gingival contour move to the apical portion, and the root area is exposed. It leads to the unesthetic result. Root coverage technique is classically used to treat gingival recession (marginal tissue recession) of natural teeth. It is an essential technique on periodontal plastic surgery part. It is also a very useful technique to recover soft tissue problems in implant dentistry. So, root coverage technique must be mastered for a good implant esthetic result. The general overview of root coverage procedures will be discussed with step by step explanation to get more esthetic result.

Full-mouth rehabilitation with implant-supported fixed dental prostheses for the edentulous maxilla and partially edentulous mandible: A case report (상악 완전 무치악 및 하악 부분 무치악 환자에서 임플란트 지지형 고정성 보철물을 이용한 전악 수복 증례 보고)

  • Kim, Tae-Hyung;Oh, Kyung-Chul;Moon, Hong-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.374-381
    • /
    • 2019
  • A conventional approach for the treatment of long-span edentulous areas is the use of removable dentures. However, placing implants in these areas results in superior functional outcomes by increasing the stability, support, and resistance of the prostheses and improving the masticatory efficiency. Treatment modalities utilizing implants can be further classified into either removable or fixed-type prostheses. Several factors such as the amount of alveolar bone resorption, inter-arch relationship, patient preferences, and socioeconomic status should be considered when determining the appropriate treatment approach. Monolithic zirconia has been considered a suitable material for implant-supported fixed dental prosthesis, because of the drastic improvement in its mechanical properties. It exhibits fewer incidences of fracture and chipping of the prostheses, and has greater bulk of material than metal-ceramic crowns and zirconia-veneered ceramics. Moreover, highly translucent monolithic zirconia is also available in the market, and its application is gradually increasing for anterior tooth rehabilitation. The present report describes a patient who underwent full-mouth rehabilitation with fixed dental prostheses (eight upper and three lower implant placements). All teeth, except bilateral mandibular canines and left mandibular first and second premolars, were extracted after the diagnosis of generalized chronic moderate-to-advanced periodontitis of the remaining teeth. The patient reported satisfactory esthetic and functional outcomes during the one-year follow-up visit.

A Study of Current Perception Threshold of Trigeminal Nerve after Tooth Implantation (치아임플란트 시술 후 삼차신경에서의 전류인지역치에 대한 연구)

  • Lim, Hyun-Dae;Lee, Jung-Hyun;Lee, You-Mee
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.2
    • /
    • pp.187-200
    • /
    • 2007
  • This study attempted to contribute to the clinical application of implant operation by making a quantitative nerve examination using a neurometer for the evaluation of sensory disturbances that could be incurred after the implantation in the dental clinics, and it intended to establish an objective guideline in the evaluation of sensory nerve after the operation of implant. An inspection was performed with the frequencies of 2000Hz, 250 Hz and 5 Hz before and after the operations of tooth implant using $Neurometer^{(R)}$ CPT/C (Neurotron, Inc. Baltimore, Maryland, USA) for 44 patients who had performed an implant operation among the patients coming to Daejeon Sun Dental Hospital in 2006 and 30 people for control group. The measuring sites were maxillary nerve ending and mandibular nerve ending of trigeminal nerve according to the implant operating regions. The current perception threshold (CPT) by each nerve fiber was specifically responded under the electric stimulation of 2000 Hz in case of $A{\beta}$ fiber and of 250 Hz in case of $A{\delta}$ fiber and of 5Hz in case of C fiber. The CPT test could be performed to assess the damages of peripheral nerve in the trigeminal nerve area and it stimulated selective nerve fibers by generating the electricity of specific frequency in the peripheral nerve area. The nerve fibers with varied thickness were responsive selectively to the electric stimulation with different frequencies; accordingly, they applied the electric stimulation with different frequencies and the reaction threshold of $A{\beta},\;A{\delta}$ and C fibers selectively responsive to each electric current could be individually evaluated. In the assessment through the CPT, the increase and decrease of the CPT could be measured so that sensory disturbances such as hyperaesthesia or hypoaesthesia could be diagnosed. This study could obtain the following results after the assessment of the CPT before and after the implant operation. 1. In the assessment before and after the implant operation, the CPT in the frequencies of 2000 Hz, 250 Hz, 5 Hz for maxillary branch increased on the whole after the operation and the CPT for mandibular branch in the $A{\beta}$-fiber(2000 Hz) and C-fiber(5 Hz )after the operation increased statistically significantly. 2. For the groups of patients with medically compromised or its subsequent medicinal prescription, there were no significant differences before and after the implant operation and for the control groups, significantly high CPT was shown after the implant operation in the left $A{\beta}$-fiber(2000 Hz) and C-fiber(5 Hz). 3. In the comparison of the measured value of the CPT before the operation between the control group and the implant operation group, the latter group had a significantly high measured value of the CPT in the right $A{\beta}$-fiber(2000 Hz) and C-fiber(5 Hz) and there were significant differences in $A{\beta}$-fiber(2000 Hz) in the CPT assessment after the implant operation for the control group. 4. Male participants had higher CPT than female counterparts; however, there were no statistic significances. In the CPT evaluation before and after implant operation, there were no statistical differences in the male group while the right C-fiber(5 Hz) and left $A{\beta}$-fiber(2000Hz) were significantly high in the female group. 5. In the comparison between the group who complain sensory disturbance and the other group, the CPT increased on the whole in the former group, but there were no statistical significances. In the groups, whom there was an increase in VAS, the CPT after the implant operation in the right C-fiber(5 Hz) increased significantly; meanwhile, in case that the VAS mark was '0' before and after the operation, the CPT after the operation in the left $A{\beta}$-fiber(2000 Hz) increased significantly. This study suggested that the CPT measurements using $Neurometer^{(R)}$ CPT/C, provide useful information of objective and quantitative sensory disturbances for tooth implantation.

Full mouth implant rehabilitation with double scanning of provisional restoration (임시치아 double scanning을 이용한 전악 임플란트 수복 증례)

  • Yang, Dong-Hun;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.252-257
    • /
    • 2014
  • It is important to produce a provisional restoration reflecting the patient's jaw relation, occlusal plane, lip support, shape of teeth, and occlusion type for fully edentulous patients before making a definite prosthesis. The patient introduced in this study showed bad prognosis of remained tooth after severe periodontal diseases. Therefore, remaining teeth were extracted and replaced with dental implants. Provisional restorations were fabricated and the the patient's vertical and horizontal jaw relationship, occlusal plane, amount of overjet and overbite, size of teeth, and length of anterior tooth were recorded. Provisional restorations were scanned and CAD/CAM techniques were used to fabricate a monolithic zirconia bridge, which contour is identical with the provisional restorations. The patient was satisfied with the treatment results on functional, esthetic aspects and the prosthesis retained stable during the four-month clinical observation period.

Prosthetic full mouth rehabilitation of patient with mandibular prognathism and asymmetry: a case report (하악의 전돌 및 비대칭을 가진 환자에서 보철적 전악 구강회복 증례)

  • Jaeyeong Lim;Hwa-Jeong Lee;Jong-Eun Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.28-37
    • /
    • 2024
  • Severe cases of mandibular prognathism can be treated with orthodontic therapy or surgical correction, but there are situations where only prosthetic improvement is possible. An understanding of class III patients is needed, including a vertical chewing pattern and the absence of anterior guidance. Additionally, it is relatively easy to increase occlusal vertical dimension to correct the anterior crossbite, but this approach can sometimes lead to unfavorable results, necessitating careful diagnosis and treatment planning. In this case report, oral rehabilitation was conducted in a patient with mandibular prognathism and asymmetry, utilizing implants and fixed dental prosthesis. Through a step-by-step treatment approach, the existing occlusal vertical dimension was maintained, and the final fixed dental prosthesis restoration was completed. Accordingly, it shows functional and aesthetically appropriate results, and reports on the patient's diagnosis and treatment process.

Effects of Magnetic Resonance Imaging on the Human Body : Analysis of differences according to Dental Implant Material (자기공명영상이 인체에 미치는 영향 : 치아임플란트 재료에 따른 차이 분석)

  • Choe, Dea-yeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.481-489
    • /
    • 2018
  • In MRI examination, when irradiating the human body with RF Pulse to acquire images, the portion of the irradiated RF Pulse energy is absorded into the human body, and this will affect the temperature of the human body. If a metal is inserted into the human body even if the same RF Pulse energy is applied, the SAR value increases and the body temperature changes due to the increase in the electromagnetic wave conductivity of the metal. So we measure and compared with the change in the SAR and temperature in the implant material of the dental implant in Brain MRI examinations. Experiments were performed on a human head model using a 64MHz and 128 MHz RF Pulse frequency generated by a 3.0 Tesla MRI apparatus. And then changed material of dental implants to Titanium and $Al_2O_3$. Using the XFDTD program, the changes in SAR and body temperature around the head were examined. When with Titanium the SAR value and temperature of Brain increased, but with $Al_2O_3$ showed lower SAR and temperature as compared with Titanium. The dental implants were low in SAR and temperature of the head in $Al_2O_3$, which are electrical insulators with low electrical conductivity, compared to Titanium, which is an electrical conductor. It is necessary to study the biologic effect of patient with brain MRI when titanium dental implant material is inserted in the future. Because the maximum value of SAR is much higher than the limit when dental implant material is Titanium. In addition, it is necessary to use an implant of $Al_2O_3$ material to reduce the SAR value and temperature of the Brain in Brain MRI examination.