• Title/Summary/Keyword: 임윤희

Search Result 42, Processing Time 0.027 seconds

A study on the vibration of 2-phase HB type Linear Stepping Motor (2상 HB형 선형 STEPPING 전동기의 진동해석에 관한 연구)

  • Oh, H.S.;Jung, E.N.;Sim, S.H.;Lim, Y.H.;Lee, S.K.;Shim, J.S.;Shim, N.S.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.852-854
    • /
    • 2001
  • In this paper, the vibration characteristics of a 2-phase Hybrid type Linear Stepping Motor(HLSM) are analyzed using the ACSL. A magnetic equivalent circuit is based on the structure of the HLSM, and then the electric equivalent circuit of the HLSM is derived by solving equations for the magnetic equivalent circuit. A normal force is calculated using FEM(Flux2D). And the vibration characteristics(Continuous vibration) of the HLSM are simulated by the ACSL with the voltage equations, the thrust equation, the normal force equation and the kinetic equation.

  • PDF

$NH_3$ oxidation using Ag-Cu/$Al_2O_3$ composite catalyst at low temperature (Ag-Cu/$Al_2O_3$ 복합촉매를 이용한 저온에서의 $NH_3$ 산화)

  • Lim, Yun-Hui;Lee, Ju-Yeol;Park, Byung-Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.313-319
    • /
    • 2014
  • This study was performed to obtain high conversion efficiency of $NH_3$ and minimize generation of nitrogen oxides using metal-supported catalyst with Ag : Cu ratio. Through structural analysis of the prepared catalyst with Ag : Cu ratio ((10-x)Ag-xCu ($0{\leq}x{\leq}6$)), it was confirmed that the specific surface area was decrease with increasing metal content. A prepared catalysts showed Type II adsorption isotherms regardless of the ratio Ag : Cu of metal content, and crystalline phase of $Ag_2O$, CuO and $CuAl_2O$ was observed by XRD analysis. In the low temperature($150{\sim}200^{\circ}C$), a conversion efficiency of AC_10 recorded the highest(98%), whereas AC_5 (Ag : Cu = 5 : 5) also showed good conversion efficiency(93.8%). However, in the high temperature range, the amounts of by-products(NO, $NO_2$) formed with AC_5 was lower than that of AC_10. From these results, It is concluded that AC_5 is more environmentally and economically suitable.

Improvement of Spinal Central Pain by Brachial Plexus Block -A case report- (상완 신경총 차단에 의한 척수성 중추통증의 완화 -증례보고-)

  • Kim, Ok Sun;Lee, Woo Yong;Yoo, Byung Hoon;Lim, Yun Hee;Kim, Seung Oh
    • The Korean Journal of Pain
    • /
    • v.19 no.2
    • /
    • pp.241-243
    • /
    • 2006
  • Central pain is defined as pain associated with lesions of the central nervous system, and is among the most intractable of chronic pain syndromes. A 47 year-old-female, who had right arm and shoulder pain, was diagnosed with syringomyelia of the Arnold Chiari malformation type I and received foramen magnum decompression and a syringo-subarachnoid shunt. After the operation, the evoked pain was improved, but she complained of a continuous burning pain, coupled with cold and tactile allodynia. This symptom failed to fully subside on administration of oral medicine; therefore, brachial plexus block was performed, which relieved her pain transiently. Through repeated trials, a gradual decrease in the pain intensity and frequency was found. However, the way in which brachial plexus block improves spinal central pain is not completely known.

Study of toluene decomposition using nonthermal plasma and catalyst (저온플라즈마와 촉매를 이용한 톨루엔 분해 연구)

  • Lim, Yun Hui;Lee, Ju-Yeol;Shin, Jae-Ran;Choi, Jin-Sik;Park, Byung Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.541-548
    • /
    • 2014
  • This study was performed to obtain high conversion efficiency of $C_7H_8$ using non-thermal plasma and metal-supported catalyst. Adsorption-desorption characteristics of toluene was performed using 4A type (Zeolite) filled in a concentration reactor. Through this test, it was found that the concentration reactor has 0.020 g/g of adsorption capacity (at ambient temperature and pressure) and 3,600 ppm of desorption property at $150^{\circ}C$ (with in 20 min). In case of developed catalyst, toluene decomposition rate of Pd-AO (Pd coated catalyst) was better than Pd/Cu-AO and Pd/Ag-AO (Pd/Ag composite metal catalyst). Developed non-thermal plasma system was obtained flame amplification effect using injection process of desorbed tolune, and 98% of removal efficiency.

Electrical Properties of OLEDs depending on the Surface Roughness (표면 거침도에 따른 OLEDs의 전기적 특성)

  • Kim, Weon-Jong;Lee, Young-Hwan;Lim, Yun-Hee;Shim, Nak-Soon;Lee, Sang-Kyo;Shin, Jong-Yeol;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1327-1328
    • /
    • 2007
  • A base structure of device was made to be ITO/tris(8-hydroxyquinoline) aluminum ($Alq_3$)/Al and the $Alq_3$ organics were evaporated to be 100nm thick at a deposition rate of $1.5\;{\AA}/s$. In order to investigate the optimal surface roughness of $Alq_3$, the $Alq_3$ was thermally evaporated to be 0.8 mm, 1.0 mm, 1.5 mm 2.0 mm and 3.0 mm as a hole-size of the crucible, respectively. When the hole-size of the crucible is 1.0 mm, we found that when the hole-size of the crucible is 1.0 mm, the electrical properties are superior to the others.

  • PDF

Experimental studies of energy savings and economic effects by direct removal of carbon dioxide in the multi-use facility ($CO_2$ 직접 제거를 통한 다중이용시설의 에너지 절감 및 경제적 효과에 대한 실험적 연구)

  • Kim, Yo Seop;Lee, Ju-Yeol;Choi, Jin Sik;Shin, Jae Ran;Lim, Yun Hui;Park, Byung Hyun;Kim, Yoon-Shin
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.466-471
    • /
    • 2014
  • It is important to develop the smart ventilation system in order to minimize a building energy consumption using ventilation. In this study, We evaluated the efficiency of the smart ventilation system being developed at the nursery. To evaluate the energy savings and carbon dioxide removal efficiency, two kinds of experimental conditions were compared. First, air conditioner and Smart HVAC system were operated. Second, air conditioner was operating and external air was put into the inside by rate of air circulation. It was more effective when working with air conditioning and ventilation system at the same time. If the Smart HVAC system is applied in a multi-use facility, indoor air quality will be comfortable and the social cost will be reduced.

A study of low-level $CO_2$ adsorption using dry sorbents (건식 흡착제를 이용한 저농도 이산화탄소 흡착 연구)

  • Kim, Yo-Seop;Lee, Ju-Yeol;Lim, Yun-Hui;Shin, Jae-Ran;Park, Byung-Hyun;Kim, Yoon-Shin
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.394-401
    • /
    • 2014
  • In order to minimize a building energy consumption with ventilation, a development of smart ventilation system is very important. In this study, a dry adsorbent that is main element of smart ventilation system was developed for removing indoor $CO_2$, and evaluate the adsorption performance. Specific surface area, pore characteristic and crystal structure of the modified sorbent was measured to analyze physical properties. From this analysis, it was found that the developed absorbent has a low specific surface area, due to mesopores of substrate was filled with metal contained raw material. Additionally, through analysis of the adsorption properties, the developed adsorbent was shown a adsorption form of mesopore (type IV), which means adsorption amount was rapidly increased at the part of high-pressure. Order to applying for the field, chamber test was performed. Continuous column tests (2,500 ppm) and batch chamber tests ($4m^3$, 5,000 ppm) showed $CO_2$ removal efficiency of 95% and 88% within 1 hour, respectively.

Study on preparation of blast furnace slag mortars using alkali activation (알칼리 활성화에 의한 고로슬래그 경화체의 제조 연구)

  • Shin, Jae Ran;Lim, Yun Hui;Lee, Ju Yeol;Park, Byung Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.188-193
    • /
    • 2015
  • Blast Furnace Slag is good for enhancing the qualities of concrete such as reducing hydration heat increasing fluidity, long-term strength and durability, but it has some problems: construction time is increased or the rotation rate of form is decreased due to low development of early strength. In this study, an aqueous alkali solution for alkali activated reaction was obtained by the electrolysis using concentrated water discharged from seawater desalination process. Prepared aqueous alkali solution was applied to produce mortars using blast furnace slag. The results can be summarized as follows : For the mortar, compressive strength was decreased below 2% of NaOH and increased below 6% of NaOH. And compressive strength was increased gradually with increasing NaOCl contents. However, NaCl contents of mortars caused a decrease of 28days strength above early strength.

Efficacy of Low Frequency Stimulator in Patients with Frozen Shoulder (오십견 환자의 치료에 있어서 저주파자극기의 효과)

  • Lim, Yun Hee;Lee, Pyung Bok;Seo, Myung Sin;Park, Sang Hyun;Oh, Yong Seok;Park, Ji Hyun
    • The Korean Journal of Pain
    • /
    • v.18 no.2
    • /
    • pp.156-160
    • /
    • 2005
  • Background: Frozen shoulder is not an uncommon disease, which is associated with chronic pain and joint movement limitation. However, there are numerous devices to assist in the treatment of shoulder pain, but their efficacy has not been proven and their use remains immensely controversial. Therefore, a randomized clinical study was conducted to determine the effectiveness of a low-frequency stimulator for the treatment of frozen shoulder. Methods: A randomized clinical trial was carried out on 40 patients with frozen shoulder, with 40 patients assigned to two groups; a control treatment group (group C, n = 20) and a low frequency stimulator application group (group T, n = 20). Both groups were given a routine treatment modality, such as trigger point injection, intramuscular stimulation or suprascapular nerve block etc. The level of the shoulder pain was evaluated using a 100mm VAS (visual analog scale) at each visit, with the limitation in the range of motion simultaneously evaluated. Results: All the subjects improved after treatment, with the VAS scores after termination of treatment showed a statistically significant reduction (P < 0.05). However, there was no significant difference between the two groups. One month after termination of 5 cycles of treatment, group T maintained their improved state, whereas the pain in some of those in group C reemerged, which also showed a statistically significant difference (P < 0.05). The limitation in the range of motion improved, with most subjects able to resume daily activity. Conclusions: Although the low frequency stimulation provided no more pain relief than routine treatment, the effect was significantly prolonged. From this result, low frequency stimulation can be considered to aide the therapeutic effect of classical frozen shoulder therapy.

Analytical Study on the Fire Resistance of iTECH Composite Beam (iTECH 합성보의 내화성능에 대한 해석연구)

  • Lim, Yoon Hee;Kang, Seong Deok;Oh, Myoung Ho;Kim, Myeong Han;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.5
    • /
    • pp.655-664
    • /
    • 2006
  • The purpose of thisanalytical study of an iTECH composite beam subjected to fire conditions is to determine the beam's fire resistance performance using its load ratio and fire protection as parameters. A composite structural system is expected to have a safer and more economical fire safety design than a mere collection of isolated members.heat transfer analysis was performed on the basis of the finite element program ANSYS 10.0 using an ISO834 standard fire, following the main guidelines proposed by EC1 Part 2.2 and EC4 Part 1.2. To validate the analytical simulation of the iTECH composite beam, comparison of the experimental tests was proposed.