• Title/Summary/Keyword: 임용규

Search Result 96, Processing Time 0.022 seconds

Comparison of computer-based treatment prediction with true results in bimaxillary protrusion cases (치조성 양악 전돌 환자에서 컴퓨터를 이용한 치료 결과 예측의 정확성)

  • Lee, Rhi-na;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.32 no.3 s.92
    • /
    • pp.155-163
    • /
    • 2002
  • This study was performed to assess the accuracy of computer-based treatment prediction for soft tissue profile using Quick Ceph Image $Pro^{TM}\;&\;Quick\;Ceph\;2000^{TM}$ in bimaxillary protrusion cases. The Ore- and post-treatment lateral cephalograms of 21 female adults treated by low first premolar extraction were imaged and 9 landmarks and 27 specific soft tissue mesurements were digitized for comparing actual treatment results with computer simulations. The results of this study showed that Quick Ceph Image $Pro^{TM}\;&\;Quick\;Ceph\;2000^{TM}$ tends to overestimeate horizontal changes and underestimate vertical changes. In the computer simulation, upper lip showed rolling tendency. The upper lip measurements were disposed to be regular direction hut lower lip measurements were varied case by case even if it was statistically insignificant.

Formation of PVP- Based Organic Insulating Layers and Fabrication of OTFTs (PVP-기반 유기 절연막 형성과 OTFT 제작)

  • Jang, Ji-Geun;Seo, Dong-Gyoon;Lim, Yong-Gyu
    • Korean Journal of Materials Research
    • /
    • v.16 no.5
    • /
    • pp.302-307
    • /
    • 2006
  • The formation and processing of organic insulators on the device performance have been studied in the fabrication of organic thin film transistors (OTFTs). The series of polyvinyls, poly-4-vinyl phenol(PVP) and polyvinyltoluene (PVT), were used as solutes and propylene glycol monomethyl ether acetate(PGMEA) as a solvent in the formation of organic insulators. The cross-linking of organic insulators was also attempted by adding the thermosetting material, poly (melamine-co-formaldehyde) as a hardener in the compound. The electrical characteristics measured in the metal-insulator-metal (MIM) structures showed that insulating properties of PVP layers were generally superior to those of PVT layers. Among the layers of PVP series: PVP(10 wt%) copolymer, 5 wt% cross-linked PVP(10 wt%), PVP(20 wt%) copolymer, 5 wt% cross-linked PVP(20 wt%) and 10 wt% cross-linked PVP(20 wt%), the 10 wt% cross-linked PVP(20 wt%) layer showed the lowest leakage current characteristics. Finally, inverted staggered OTFTs using the PVP(20 wt%) copolymer, 5 wt% cross-linked PVP(20 wt%) and 10 wt% cross-linked PVP(20 wt%) as gate insulators were fabricated on the polyether sulphone (PES) substrates. In our experiments, we could obtain the maximum field effect mobility of 0.31 $cm^2/Vs$ in the device from 5 wt% cross-linked PVP(20 wt%) and the highest on/off current ratio of $1.92{\times}10^5$ in the device from 10 wt% cross-linked PVP(20 wt%).

Development of CNC controller based on i80486 and 32bit DSP chip (i80486과 32비트 DSP를 사용한 CNC 제어기의 개발)

  • Kim, Dong-Il;Song, Jin-Il;Kim, Sung-Kwan;Lee, Choong-Hwan;Lee, Yun-Suk;Kang, Moon;Na, Sang-Keun;Lim, Yong-Gyu;Nam, Ki-Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.537-540
    • /
    • 1992
  • This paper presents Samsung CNC (Computer Numerical Controller) system with an intel 80486/487 as the main CPU and a 32 bit floating point DSP(Digital Signal Processor) TMS320C30 as the motion control CPU. The Samsung CNC system diverse user-frienly characteristics such as multi-tasking, powerful menu system, internal PLC system, and 2/3 dimensional graphics in wire and solid mode. The main CPU executes central processing program, user interface program, interpreter, BMI, etc while the motion control CPU carries out some interpolations, acceleration/deceleration, and PID control algorithm with feedforward terms. Complex interpolations except linear and circular ones are performed on the main control CPU. The experimental results for the circular interpolation under linear acceleration/deceleration shows that the proposed CNC system can be widely used in controlling machining centers with good machining accuracy.

  • PDF

Formation and Characterization of Polyvinyl Series Organic Insulating Layers (폴리비닐 계열 유기절연막 형성과 특성평가)

  • Jang Ji-Geun;Jeong Jin-Cheol;Shin Se-Jin;Kim Hee-Won;Kang Eui-Jung;Ahn Jong-Myong;Seo Dong-Gyun;Lim Yong-Gyu;Kim Min-Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.1 s.14
    • /
    • pp.39-43
    • /
    • 2006
  • The polyvinyl series organic films as gate insulators of thin film transistor(TFT) have been processed and characterized on the polyether sulphone (PES) substrates . The poly-4-vinyl phenol(PVP) and polyvinyl toluene (PVT) were used as solutes and propylene glycol monomethyl ether acetate(PGMEA) as a solvent in the formation of organic insulators. The cross-linking of organic insulators was also attempted by adding the thermosetting material, poly (melamine-co-formaldehyde) as a hardener in the compound. The electrical characteristics measured in the metal-insulator-metal (MIM) structures showed that insulating properties of PVP layers were generally superior to those of PVT layers. Among the layers of PVP series; copolymer PVP(10 wt%), 5wt% cross-linked PVP(10 wt%), copolymer PVP(20 wt%), 5 wt% cross-linked PVP(20 wt%) and 10 wt% cross-linked PVP(20 wt%), the 10 wt% cross-linked PVP(20 wt%) layer showed the lowest leakage current of 1.2 pA at ${\pm}10V$. The ms value of surface roughness and the capcitance per unit area are 2.41 and $1.76nF/cm^2$ in the case of 10 wt% cross-linked PVP(20 wt%) layer, respectively.

  • PDF

A Study on Intrinsic Noise of Capacitively Coupled Active Electrode (용량성 결합 능동 전극의 내부 잡음 분석)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.1
    • /
    • pp.44-49
    • /
    • 2012
  • The indirect-contact ECG measurement is a newly developed method for unconstrained and nonconscious measurement in daily Life. This study is the first step to reducing the large background noise appearing in indirect-contact ECG. This study built the thermal noise model of capacitively coupled active electrode which is used in indirect-contact ECG. The results show that the level of thermal noise estimated by the thermal noise model is much the same as that of actual background noise for the capacitively coupled active electrode alone. By applying the actual electrical properties of a sample cotton cloth to the thermal noise model, the theoretical level of thermal noise in the indirect-contact ECG was estimated. The results also show that the level of op-amp's intrinsic noise is so small that it can be negligible in comparison with thermal noise of resistors. The relationship between the level of thermal noise and the resistance of the bias resistor was derived, and it is the base for the further study how to choice the optimal resistance for the bias resistor.

Development of Chair Backrest for Non-intrusive Simultaneous Measurement of ECG and BCG (심전도와 심탄도의 무구속적 동시 측정을 위한 의자 등받이 개발)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.104-109
    • /
    • 2018
  • A non-intrusive ECG and BCG measurement system is introduced. The system is built on a auxiliary backrest of a chair. The developed system is aimed to non-intrusive assessment of cardiovascular dynamic indices such as pulse arrival time(PAT) and pre-ejection period (PEP). In the system, capacitive active electrodes and capacitive grounding were used for the non-intrusive indirect-contact ECG measurement, and EMFi pressure sensor was used for the non-intrusive BCG measurement. The capacitive active electrodes and the EMFi sensor were attached on the backrest. Using the system, ECG and BCG were successfully acquired. The measured BCG showed peaks that following ECG R peaks. It was shown that the time interval between Q wave in ECG and first peak in BCG correlates Pre-ejection period measured by impedance-cardiogram. The results showed that the introduced system can be used for the non-intrusive various cardiovascular information including ECG, PAT, PEP.

A Study on comnon-mode-driven shield for capacitive coupling active electrode (용량성 결합 능동 전극의 공통 모드 구동 차폐)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.4
    • /
    • pp.201-206
    • /
    • 2012
  • The indirect-contact ECG measurement is a newly developed method for unconstrained and nonconscious measurement in daily life. This study introduced a new method of electrode circuit design developed for reducing the 60Hz power line noise observed at the indirect-contact ECG measurement. By the introduced common-mode-driven shielding, the voltage of the electrical shield surrounding the capacitive coupling electrode is maintained at the same as the common mode voltage. Though the method cannot reduce the level of common mode voltage itself, that reduces effectively the differential mode noise converted from the common mode voltage by the difference of cloth impedance between the two capacitive coupling electrode. The experiment results using the actual indirect-contact ECG showed that the 60Hz power line noise was reduced remarkably though the reduction ratio was smaller than the expected by the theory. Especially, the reduction ratio became large for the large difference of cloth. It is expected that the introduced method is useful for reducing the power line noise under condition of poor electrical grounding.

Decrease in the Particle Size of Paclitaxel by Increased Surface Area Fractional Precipitation Process Using Hydrophilic Polymer (표면적이 증가된 분별침전에서 친수성 고분자물질을 이용한 paclitaxel의 입자 크기 감소)

  • Lim, Yong Kyu;Kim, Jin-Hyun
    • Microbiology and Biotechnology Letters
    • /
    • v.43 no.4
    • /
    • pp.343-349
    • /
    • 2015
  • In this study, we applied an increased surface area fractional precipitation with hydrophilic polymer for decreasing the particle size of the anticancer agent paclitaxel from plant cell cultures. The addition of polymer resulted in a considerable decrease in the size of the paclitaxel precipitate. Among the polymers (HPMC 2910, PVP-K90, PVA) used, PVP-K90 was the most effective for the inhibition of precipitate growth. When PVP-K90 (0.2%, w/v) was used, the paclitaxel particles were four to five times smaller, having less than a $20{\mu}m$ radius, than those obtained in the absence of the polymer. In addition, the precipitate size was inversely correlated with the absolute value of zeta potential.

A study on the advancement of discharge calculation algorithm in automatic discharge observation system (자동유량 관측 시스템의 유량산정 알고리즘 고도화에 관한 연구)

  • Kyoung Won Park;Young Ho Lee;Su Yeon Kim;Yong Kyu Lim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.370-370
    • /
    • 2023
  • 수자원이란 인간의 생활이나 경제활동 및 자연환경 유지 등을 하는데 이용할 수 있는 자원으로서의 물을 말하며 효율적인 수자원의 활용을 위해서는 수문조사가 필수적이라고 할 수 있다. 수문조사는 강수량, 수위, 유량, 유사량, 증발산량, 토양수분량을 측정, 조사, 분석하는 것이라고 할 수 있으며 이 중 유량은 강우-유출 관계 규명, 이수, 치수 등을 위해 높은 정확도의 관측자료가 필요하다. 그러나 하천유량은 장기간 연속적으로 관측하는 것이 어려우므로 특성 횟수의 유량조사를 통해 수위-유량관계곡선식(Rating curve)을 개발하여 수위로부터 연속적인 유량을 산정하여 활용하고 있어 이를 개선하기 위해 전자파표면유속계를 활용한 자동유량측정장치를 개발하였으며 측정자료 분석 및 알고리즘 고도화를 통해 신뢰도 높은 유량을 산정하고자 하였다. 운동하는 물체에 의하여 산란된 전자파의 주파수가 변하게 되는 현상을 도플러 효과라고 하며 이때의 주파수의 변화량을 도플러 주파수라고 한다. 전자파표면유속계는 하천 수면으로 전자파를 발사한 후 물 표면에서 반사되는 전자파의 도플러 효과를 이용하여 표면유속을 측정하는 것으로 전자파표면유속계를 교량 상류 방향으로 고정시켜 설치하였으며 측정된 자료는 유량관측 시스템에서 저장, 관리되고 물리적, 통계적 방법이 적용된 알고리즘을 통해 유량을 산정한다. 산정된 유량의 정확도 확보를 위해 바람 영향, 최적 환산계수 재산정, 통계분석 등을 통해 시스템의 유량산정 알고리즘 개선 방안을 도출하였으며 개선된 알고리즘이 적용된 유량은 NSE(Nash Sutcliffe Efficiency), PBIAS(Percent Bias), RSR(RMSE-observations standard edviation ratio)을 통해 평가하였다. 바람 영향은 유량 관측 고도화 매뉴얼(일본 토목연구소)의 경험식과 현장에서 관측된 풍향·풍속을 활용하여 분석하였으나 개선효과가 미미한 것으로 나타났으며 자동으로 관측된 유량자료에 포함된 무작위적인 변화량을 감소시키기 위해 경향성 분석을 병행하여 이동평균 방법을 적용하였다. 또한 ADCP 등을 활용한 유량측정성과와 수위-유량관계곡선식과의 비교·분석을 통해 수위별 최적 환산계수를 산정하여 유량산정 알고리즘에 적용한 결과 NSE는 0.980, PBIAS는 1.580, RSR은 0.142로 모두 Very Good(높은 상관성)으로 분석되어 유량자료의 정확도를 확보하였다.

  • PDF

Comparison of bony changes between panoramic radiograph and cone beam computed tomographic images in patients with temporomandibular joint disorders (측두 하악 관절 장애 환자의 파노라마 영상과 cone beam형 전산화 단층 영상의 비교)

  • Lee, Dong-Yul;Kim, Yun-Jung;Song, Yun-Heon;Lee, Nam-Ho;Lim, Yong-Kyu;Kang, Sung-Taek;Ahn, Sug-Joon
    • The korean journal of orthodontics
    • /
    • v.40 no.6
    • /
    • pp.364-372
    • /
    • 2010
  • Objective: This study was designed to assess the diagnostic validity of digital panoramic radiographs compared to cone beam computed tomography (CBCT) in patients with temporomandibular joint disorders. Methods: Panoramic radiograph and CBCT were taken from a total of 212 joints from 106 subjects. The joints were examined by two dentists and divided into the following six groups: normal, flattening, osteophyte formation, erosion, sclerosis, and unclassified. The sensitivity and specificity of each observer and inter-observer reliability were statistically analyzed. Results: The results showed relatively high intra-observer reliability in the diagnosis of both panoramic and CBCT images and the weighted Kappa indices of panoramic and CBCT images were 0.714 and 0.727, respectively. The sensitivities of panoramic images of observer A and B to CBCT images was 82.35% and 84.30%, respectively, while the specificity of observer A and B was 58.06% and 61.54%, respectively. However, guided diagnosis from panoramic and CBCT images were statistically different (p < 0.05). Conclusions: The present study suggests that the panoramic radiograph could be used as a primary diagnostic device to detect bony changes of temporomandibular joints in clinical orthodontics, because panoramic images showed relatively high sensitivity compared to CBCT images. However, CBCT images may be one of the best choices when a more accurate diagnosis is necessary.