Adhesive Polyurethane-based Capacitive Electrode for Patch-type Wearable Electrocardiogram Measurement System (패치형 웨어러블 심전도 측정 시스템을 위한 접착성 폴리우레탄 기반의 용량성 전극)

  • Lee, Jeong Su;Lee, Won Kyu;Lim, Yong Gyu;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.203-210
    • /
    • 2014
  • Wearable medical device has been a resurgence of interest thanks to the development of technology and propagation of smart phone in recent years. Various types of wearable devices have been introduced and available in market. Capacitive coupled electrode which measures electrocardiogram over cloth is able to be applied wearable device. In previous approaches of capacitive electrode, they need proper pressure for stable contact of the electrode to body surface. However, wearable device that gives pressure on body surface is not suitable for long-term monitoring. In this study, we proposed adhesive polyurethane-based capacitive electrode for patch-type wearable electrocardiogram (ECG) monitoring device. Self-adhesive polyurethane make the electrode and whole system be adhered to the surface of skin without any pressure. The patch-type system is consisted of analog filter, analog-to-digital converter and wireless transmission module and designed to be attached on the body as a patch. To validate the feasibility of the developed system, we measured ECG signal in stable and active state and extracted heart rate. Therefore, we observed skin response after long-term attachment for biocompatibility of the adhesive polyurethane and adhesive strength of it. The result shows the possibility of applying the developed system for ECG monitoring in real-life.

Development of Online Speller using Non-contact Blink Detection Glasses (비접촉 눈 깜박임 측정 안경형 디바이스를 이용한 실시간 스펠러의 구현)

  • Lee, Jeong Su;Lee, Hong Ji;Lee, Won Kyu;Lim, Yong Gyu;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.283-290
    • /
    • 2015
  • We proposed blink based online speller for the locked-in syndrome (LIS) patients, paralyzed in nearly all voluntary muscles expect for the eyes, with a simple and easy-to-use eye blink detection glasses. Electrooculogram (EOG) is the golden standard method of eye movement or blink measurement with Ag/AgCl electrodes. However, this method has several drawbacks such as skin irritation and dehydration of conductive gel. To resolve the shortcomings, we used a blink detection system based on a transparent capacitively coupled electrode, which is conductive indium tin oxide (ITO) films. The films make it possible to measure eye blink without direct skin contact and obstruction of field of view. We finally developed user-friendly blink based online speller with the blink detection system. To classify voluntary and non-voluntary blink, we used the double blink for command of the speller. The online speller experiment result with six healthy subjects shows that mean accuracy is 98.96% and letter per minute (LPM) is 4.73, which are better result by comparison with conventional P300 or auditory brain-computer interface (BCI) paradigm. The result of the experiment demonstrates the possibility of applying the proposed system as a communication method for the LIS patients.

ECG Measurement Method during Sleep with Array of Capacitive Electrodes Attached to Bed (침대에 부착된 용량성 전극 배열을 이용한 수면 중의 심전도 측정)

  • Lim, Y.G.;Kim, K.K.;Park, K.S.;Jeong, D.U.
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.521-524
    • /
    • 2005
  • In order to measure ECG in daily life, a new ECG measurement method on bed was developed. The provided method does not require any direct conductive contact between the instrument and bare skin, so that it does not cause the uncomfortable feel of touch and the possible skin trouble which are typical shortcomings of the conventional conductive contact ECG measurement. The provided method utilized an array of high-input-impedance active electrodes fixed on the mattress and an indirect-skin-contact ground made of a large conductive textile sheet and laid on lower area of the mattress. A thin cotton bedcover covered the mattress, the electrodes, and the conductive textile and subjects lay on the mattress over the bedcover. ECG was obtained successfully. However its signal quality is lower and the motion artifact is larger than direct-contact measurement. Careful measurement setup was needed to reduce the motion artifact originated from variation in static electricity. From the ECG obtained by the provided method, R-peak could be discriminated easily and the information about the position and the posture of the subject could be obtained.

  • PDF

Fabrication of Blue OLED with GDI Host and Dopant (GDI Host-Dopant를 이용한 청색 유기발광다이오드의 제작)

  • Jang, Ji-Geun;Shin, Se-Jin;Kang, Eui-Jung;Kim, Hee-Won;Seo, Dong-Gyoon;Lim, Yong-Gyu;Chang, Ho-Jung
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.773-776
    • /
    • 2005
  • In the fabrication of high performance Blue organic light emitting diode, 2-TNATA[4,4',4"-tris(2-naphthylphenyl-phenylamino)-triphenylamine] as hole injection material and NPB[N,N'-bis(1-naphthyl)-N,N'-diphenyl-1,1'-biphenyl-4,4'-diamine] as hole transport material were deposited on the ITO (Indium Tin Oxide)/Glass substrate by vacuum evaporation. And then, Blue color emission layer was deposited using GDI602 as a host material and GDI691 as a dopant. Finally, small molecule OLED with the structure of ITO/2-TNATA/NPB/GDI602+GDI691/Alq3/LiF/Al was obtained by in-situ deposition of Alq3, LiF and Al as electron transport material, electron injection material and cathode, respectively. Blue OLED fabricated in our experiments showed the color coordinate of CIE(0.14, 0.16) and the maximum luminescence efficiency of 1.06 lm/W at 11 V with the peak emission wavelength of 464 nm.

  • PDF

Key Parameters Analysis of Important Radionuclides in Dose Evaluation Model of Decommissioning Site (해체 부지 선량평가모텔의 주요 핵종에 대한 Key parameter 분석)

  • 임용규;김학수;손중권;박경록;강기두;김경덕;정찬우
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.52-57
    • /
    • 2004
  • In order to analyze key parameters of important radionuclides in dose evaluation model of decommissioning site, a sensitivity analysis was performed. This analysis assumed a resident farmer for an exposure scenario and 0.037Bq/g for the concentration of radionuclides. As a result of sensitivity analysis, the key parameters of radionuclides considered were the area of contaminated zone, external gamma shielding factor and indoor time fraction for Cs-137 and Co-60. The key parameters for C-14 were the environmental parameters and hydrological parameters of unsaturated zone. Also, the key parameter for Sr-90 was the density of contaminated zone.

  • PDF

Comparison of the effectiveness of essential oil mouthrinse and interdental brush in patients with fixed orthodontic appliances (Original Article 1 - 교정 장치를 접착한 환자에서 essential oil mouthrinse와 치간 칫솔의 효과 비교)

  • Hong, Sook-Chan;Kang, Sung-Taek;Shin, Joo-Hee;Lim, Yong-Kyu;Lee, Dong-Yul
    • The Journal of the Korean dental association
    • /
    • v.48 no.5
    • /
    • pp.371-378
    • /
    • 2010
  • The objective of this study was to compare the effectiveness of essential oil mouthrinse and interdental brush for oral hygiene in orthodontic patient. 90 patients, with fixed orthodontic appliances, were divided into 3 groups(Group 1: patients who had only used toothbrush, group 2: toothbrush + essential oil mouthrinse, group 3: toothbrush + interdental brush). Then, plaque index(PI) and gingival index(GI) were evaluated at before(T0), 3 weeks after(Tl) and 6 weeks after(T2) the experiment. The present study revealed the following conclusions: (1) There was statistically significant decrease in PI and GI of groups 2 and 3 comparing to those of group 1 during 6 weeks.(p<0.05) (2) There was no significant difference in the level of decrease in PI and GI between group 2 and group 3.(p<0.05) The present study thus implied that use of mechanical or chemical aid such as interdental brush and mouth rinse in addition to toothbrushing may help maintaining oral hygiene in patients undergoing fixed orthodontic treatment for prolonged duration.

Effect of Buried Contact on the Epitaxial Base Silicon Solar Cell (에피텍셜 베이스 실리콘 태양전지에서 Buried Contact 효과)

  • Chang, Gee-Keun;Lim, Yong-Keu;Jeong, Jin-Cheol
    • Korean Journal of Materials Research
    • /
    • v.13 no.5
    • /
    • pp.313-316
    • /
    • 2003
  • The new epitaxial base cell as a high efficiency Si solar cell was fabricated and the effect of buried contact on the cell characteristics was investigated. In our experiments, the cell with buried contact showed the open circuit voltage of 0.62 V, the short circuit current of 40 mA, the fill factor of 0.7, and the efficiency of 10% under the incident light of AM-1 100 ㎽/$\textrm{cm}^2$. The insertion of buried contact in the epitaxial base structure brought the fabricated cell to the efficiency improvement of about 33%. The cell proposed in this paper has the structural superiority in the fabrication of high efficiency solar cell due to the carrier drift transport in the optical absorption region and the formation of back surface field by $p^{-}$ $p^{+}$ epitaxial base, and the reduction of emitter series resistance by n+ buried contact.

Antireflection layer Coating on the Epitaxial Base Si Solar Cell (에피텍셜 베이스 Si 태양전지의 광반사 방지막 처리)

  • 장지근;임용규;황용운
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2003.11a
    • /
    • pp.141-144
    • /
    • 2003
  • Si 태양전지의 기전력 형성에 이용되는 빛의 파장범위$(0.4{\mu}m\leq\lambda\leq0.97{\mu}m)$에서 AM1 스펙트럼과 Si 굴절율을 수학적으로 모델링하고 광반사 방지막$(SiO_2)$의 두께에 따른 Si 태양전지의 유효 광 흡수전력을 전산 모사하였다. 전산 모사로부터 얻어진 Si 태양전지의 유효 광흡수전력은 $SiO_2$막의 두께가 $500\AA$$1000\AA$일 때 각각 $520\;W/m^2$$450\;W/m^2$로 나타났으며, $d(SiO_2)=1000\AA$에서 최대광흡수 특성을 보였다. 광반사 방지막의 처리에 따른 유효 광흡수전력의 차이를 알아보기 위해 $SiO_2$막의 두께를 $500\AA$$1000\AA$으로 형성한 2종류의 에피텍셜 베이스 Si 태양전지$[EBS(500\AA),\;EBS(1000\AA)]$를 제작하고 효율특성을 분석한 결과, AM1 $100\;mW/cm^2$ 입사광 아래 $EBS(1000\AA)$ 전지는 $EBS(500\AA)$전지에 비해 효율이 약 $15\%$ 높게 나타났다.

  • PDF

Textured Surface Epitaxial Base Silicon Solar Cell (Textured 표면을 갖는 에피텍셜 베이스 실리콘 태양전지)

  • 장지근;임용규;정진철
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.2
    • /
    • pp.33-37
    • /
    • 2003
  • The new textured surface epitaxial base(TSEB) cell as a high efficiency Si solar cell was fabricated and its eletro-optical characteristics were investigated. The fabricated device showed the open circuit voltage of 0.62 V, the short circuit current of 40 mA, the fill factor of 0.7, and the efficiency of 16% under the incident light of AM-1 100 mW/$cm^2$. The TSEB cell proposed in this paper has the structural superiority in the fabrication of high efficiency solar cell due to the carrier drift transport in the optical absorption region and the formation of back surface field by $P^-/P^+$ epitaxial base, and the low emitter series resistance by insertion of $n^+$ buried contact.

  • PDF

Dose assessment applied with the specific data of Young-gwang area for clearance by landfill (영광지역 특성자료를 적용한 매립 자체처분 피폭선량 평가)

  • 임용규;이지훈;양호연;신상운
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.497-502
    • /
    • 2003
  • Landfill is an widely applied alternative for clearance of non-contaminated waste or slightly contaminated waste generated from nuclear facilities. In this study, exposure dose is estimated for a worker and a resident at the landfill area in Young-gwang nuclear power plant. Based on evaluated dose, clearance concentrations of each radionuclide are determinated for dose criteria of 10 $\muSv/y$. The results of age-dependent dose are 1.02 $\muSv$ per year for resident and 0.471 $\muSv$ per year for worker. Clearance concentrations for each radionuclide are evaluated from $1.33{\times}10_{-1}$ Bq per gram to $2.85{\times}10^2$ Bq per gram.