• Title/Summary/Keyword: 임시 고정 장치

Search Result 17, Processing Time 0.032 seconds

Use of Cross Pins and Temporal External Skeletal Fixator for Stabilization of a Tibial Physeal Fracture in a Korean Native Calf (한우 송아지의 정강뼈 성장판 골절에서의 교차핀과 임시 외부 골격 고정장치의 이용)

  • Heo, Su-Young;Kim, Eun-Ju;Kim, Min-Su;Lee, Ki-Chang;Kim, Nam-Soo;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.198-201
    • /
    • 2012
  • A one-month-old, male Hanwoo calf was presented to Chonbuk Animal Medical Center with non-weight bearing lameness on its right hindlimb. The radiograph and CT scan showed a Salter-Harris III fracture at the distal tibia. Following open reduction, the fracture was stabilized by cross-pins. A temporal external skeletal fixator was used as an additional support for 5 weeks. 5 weeks after surgery, bone fracture had successfully healed with no complication. At 2 years after surgery, the calf could walk almost normally although intermittent weight-bearing lameness after active exercise. This is a rare case that the combined use of temporal external fixation and cross-pins fixation was sufficiently effective for treating a distal tibial physeal fracture in a calf.

Multiple fixed implant-supported prosthesis using temporary denture and scannable healing abutment: a case report (임시의치와 스캔가능한 치유지대주를 이용한 고정성 임플란트 보철 수복 증례)

  • Hyung-Jun Kim;Hyeon Kim;Woo-hyung Jang;Kwi-dug Yun;Sang-Won Park;Hyun-Pil Lim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.250-259
    • /
    • 2023
  • The use of digital technology in fixed prosthetic treatment using implants enables predictive treatment through diagnosis and virtual surgery by integrating clinical and radiological information of patients. Existing digital scanning methods require several components to be removed, such as removing the healing abutment and connecting the scan body. In the scannable healing abutment developed in consideration of this point, scanning is performed directly on the healing abutment, maintaining soft tissue sealing and simplifying scanning. Digital technology can also be used when obtaining the intermaxillary relationship. Recently, various digital technologies have been reported to acquire the intermaxillary relationship of edentulous patients using surgical guides, patient-specific scanning devices, or scans of the inside of temporary dentures. In this case, the implant-supported fixed prosthesis treatment was performed through scanning the scannable healing abutment and the inner side of the temporary denture to obtain the intermaxillary relationship, thereby simplifying the treatment process and obtaining aesthetically and functionally excellent clinical results.

Stress Variation Characteristics of Temporary Fixed Steel Rod in FCM Bridge Construction Method (FCM 교량 가설 공법에서 임시 고정 강봉의 응력 변화 특성 )

  • Hyun-Euk Kang;Wan-Shin Park;Young-Il Jang;Sun-Woo Kim;Hyun-Do Yun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.3
    • /
    • pp.21-29
    • /
    • 2023
  • In this study, the stress characteristics of temporary fixed steel rods were analyzed in the "temporary fixing system using internal prestressing tension", which is mainly applied to the construction of superstructures by FCM. It was difficult to confirm the changes in initial tensile force in this system because the steel rod was internally connected to the pier and the PSC BOX. Therefore, measurement was performed before and after the completion of each segment using an FBG sensor to measure the change in the micro length of the steel rod. The results of the analysis showed that 75% to 90% of the maximum vertical contraction of the steel rod that occurred until the completion of the cantilever segment occurred in the fixing ~ 1segment, and the maximum loss of initial prestressing force was 39%. Such excessive loss of tension force to 1 segment means that tension is needed to improve the precision of construction during the fixation, and re-tension is needed to secure stability for conduction of cantilever segments after the completion of 1segment. In the 2 ~ last segment, the stress of the steel rod decreased gradually, and in the summer, the decrease in stress tended to partially recover due to the increase in the length of the steel rod corresponding to the increase in the vertical volume of PSC BOX. The dominant factor in the stress change in 2~ last segment in this phenomenon is judged to be the change in the length of the steel rod according to the temperature. Unlike the change in length, the relaxation was 1.2-2.7%, which was mostly offset by the opposite stress corresponding to the temperature stress. Therefore, a plan was proposed to improve the internal stress, such as adjusting the fixation time.

The Inclination Characteristics of PSC BOX in FCM Bridge Construction Method (FCM 교량 가설 공법에서 주두부의 기울음 특성)

  • Hyun-Euk Kang;Wan-Shin Park;Young-Il Jang;Sun-Woo Kim;Hyun-Do Yun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.3
    • /
    • pp.12-20
    • /
    • 2023
  • This study presents basic data on how to secure stability by analyzing the change in tensile force of steel rod and the inclination characteristics of PSC BOX in the "Temporary fixation system using internal prestressing tendon", which is mainly applied to construction of superstructures by FCM. To date, it has been difficult to confirm the changes in tension force of the steel rod and the inclination of the PSC BOX because the steel rod was installed vertically inside the pier and the PSC BOX. Therefore, measurement of the change in length of the steel rod and the displacement of PSC BOX were performed using a micro-measured FBG sensor. Comparisons of the calculated tensile force and the residual tensile force of the steel rod revealed that the safety factor decreased in all bridges. The cause was mainly identified to be the loss of tensile force in fixation~1segment, and countermeasures are suggested. The analysis of the inclination characteristics showed that the inclination increased with the segment progresses even in bridges with sufficient safety factor, and the difference before and after the segment was confirmed. In addition, the increase in inclination was related to the loss of tension force in the steel rod, and the stress on the opposite sides of the inclination was further reduced. It is believed that upward tensile force is generated in the steel rod on the opposite side of the inclined side due to the unbalanced moment, causing the difference in stress of the steel rod between the two sides.

Full mouth rehabilitation of the patient with severely worn dentition and limited vertical dimension (심한 치아 마모와 수복공간 부족을 보이는 환자에서의 완전 구강회복 증례)

  • Yang, Min-Seong;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Park, Ji-Man;Yi, Yu-Seung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.91-99
    • /
    • 2022
  • Severely worn dentition causes various complications such as loss of tooth structure, discoloration, pulp complications and loss of function and aesthetics. In this case, the patient showed particularly severe attrition in the anterior teeth and lack of space for restoration. The amount of vertical dimension was determined based on the diagnostic wax up, and the patient's adaptation was evaluated by using a removable occlusal splint for 6 weeks. Thereafter, the coordination of the muscular nervous system, aesthetics, temporomandibular joint were re-evaluated for 3 months by restoring the fixed provisional restoration. Through the above treatment process, the final restoration was completed with full mouth fixed prosthesis using monolithic zirconia, and functionally and aesthetically stable results were obtained.

QoS Routing Mechanism by using DAG in the Mobile Ad-hoc Network Environments (무선 Ad-hoc 네트워크 환경에서 DAG을 이용한 QoS 라우팅 기법)

  • Kim Jung Hee;Kim Hyun Ho;Kang Yong-hyeog;Eom Young Ik
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11a
    • /
    • pp.316-318
    • /
    • 2005
  • 무선 ad-hoc 네트워크는 중앙 집중화된 관리 시스템이나 지원 서비스 없이 동적으로 임시 네트워크를 구성하는 이동 호스트(MH)들의 집합이다. 이러한 네트워크는 백본 호스트나 다른 MH로의 연결을 제공하기 위한 고정된 제어장치를 갖지 않으며, 각 MH가 라우터로 동작하며 전달받은 패킷을 다른 MH로 전달한다. 이러한 무선 ad-hoc 네트워크에서 단순히 최선의 서비스만을 제공하던 기존의 방법과 달리, 많은 사용자가 요구하는 QoS 서비스를 지원하기 위하여 기존 네트워크를 효율적으로 최대 활용하는 방안에 대한 연구가 활발히 진행되고 있다. 본 논문에서는 무선 ad-hoc 네트워크 내에서 QoS 서비스를 제공하기 위한 기법으로 각각의 이동 호스트들은 QoS DAG 그래프를 유지하며 이러한 그래프를 바탕으로 만들어진 QoS 정보 패킷을 이웃 이동 호스트들에게 지역 브로드캐스트 함으로써 전역적인 QoS 정보의 검색과 운용없이, 유용한 QoS 정보를 전역적으로 각 이동 호스트가 유지할 수 있고 이를 바탕으로 효율적인 QoS 라우팅이 수행되어지는 기법이다.

  • PDF

Development of Post-installable Pullout Bolts and a Loading Device for Evaluating Concrete Strength (콘크리트 강도평가를 위한 인발장치와 후매입 인발볼트의 개발)

  • Ko, Hune-Bum;Lee, Ghang;Won, Jong-Sung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.3
    • /
    • pp.229-237
    • /
    • 2011
  • The pullout test is a nondestructive testing method certified by the American Society for Testing and Materials (ASTM) and British Standards (BS). Research has shown that it is very reliable in terms of evaluating the concrete strength of reinforced concrete members. However, the pullout test is rarely performed on domestic construction sites due to the complex procedures and high costs involved. This study proposes a new pullout test composed of a post installable break-off bolt, an insert nut, and a pullout tester, which satisfy both economical and practical purposes on a construction site. Three different types of special fastening methods, a temporary fixed bolt, a plastic fixed panel, and a fixed bar, have been developed. A pullout tester is proposed that is driven by the circle force introduced into a handle composed of eight gears without a load cell and a hydraulic cylinder. The serviceability and reliability of these instruments were investigated through experiments at construction sites. Furthermore, the sample pullout test with a wall specimen was conducted to estimate the usefulness of the temporary fixed bolt type of fastening methods and pullout devices. Eventually, the developed instruments will be useful on construction sites if minor requirements are met.

Oral rehabilitation of excessive tooth wear patient using zirconia fixed prosthesis with increased vertical dimension (과도한 치아 마모 환자의 수직 교합 고경 증가를 동반한 지르코니아 고정성 보철물 전악 수복 증례)

  • Jang, Ju-Ho;Choi, Yeon-Jo;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.121-129
    • /
    • 2020
  • From the point of view of oral rehabilitation, the treatment of extensive tooth wear requires a prosthetic approach. Physiological tooth wear is considered as a normal process and generally does not require treatment, but excessive tooth wear causes problems like inadequate occlusion and esthetics. Changes of occlusal vertical dimension should be made through accurate diagnosis and analysis. Also, the patient's adaptation to the changed occlusal vertical dimension should be assessed over time. This case was a 60-year-old male patient who complained of a decrease in chewing function and esthetics due to severe tooth wear. Full-mouth rehabilitation was performed with a tooth supported fixed prosthesis. An occlusal stabilization splint and provisional restoration were used to evaluate the adaptation to increased occlusal vertical dimension and induce a stable centric relation position. After that, monolithic zirconia prosthesis was delivered. We report this as a satisfactory functional recovery and esthetics.

Full mouth rehabilitation with fixed prostheses by increased vertical occlusal dimension using 3D printed splint in a patient with excessive tooth wear (과도한 치아 마모 환자의 3D 프린팅 교합안정장치를 이용한 수직 교합 고경 증가를 동반한 고정성 보철물 전악 수복 증례)

  • Se-Young Kim;Soo-Yeon Shin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.215-226
    • /
    • 2023
  • Severe wear of the anterior teeth facilitates the loss of anterior guidance, which protects the posterior teeth from wear during excursive movement. Additionally, when treating patients with collapsed occlusion due to multiple tooth loss and tooth wear, it is important to determine the presence of vertical dimension loss through accurate clinical and radiographic examinations and diagnostic wax-up. The patient of this case is a 44-year-old female patient who complained of overall tooth wear and loss of posterior teeth due to bruxism and clenching habits, visited the hospital with the address of restoring masticatory function and improving aesthetic appearance through prosthetic treatment. Through model analysis and diagnostic wax-up, an increase in vertical dimension was determined, and full mouth restoration with fixed prostheses was planned. The degree of adaptation to the vertical dimension was confirmed step by step using an occlusal splint designed with CAD (Computer aided design) software and 3-D (3-Dimensional) printed, and then restored with provisional restoration and after a 4-month adaptation period, the entire dentition was restored with metal ceramic crowns and implants. Through this procedure, satisfactory treatment results were obtained in terms of function and aesthetics.