• Title/Summary/Keyword: 임상표적체적

Search Result 41, Processing Time 0.028 seconds

Beta Dosimetry for Applying $^{166}Ho$-chitosan Complex to Cystic Brain Tumor Treatment : Monte Carlo Simulations Using a Spherical Model ($^{166}Ho$-chitosan 복합체를 이용한 낭성뇌종양 치료를 위한 베타선의 흡수선량 평가 : 구형 모델을 이용한 Monte Cairo 모사계산)

  • Kim, Eun-Hee;Rhee, Chang-Hun;Lim, Sang-Moo;Park, Kyung-Bae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.4
    • /
    • pp.433-439
    • /
    • 1997
  • $^{166}Ho$-chitosan complex, or $^{166}Ho$-CHICO, is a candidate pharmaceutical for intracavitary radiation therapy of cystic brain tumors because of the desirable nuclear characteristics of $^{166}Ho$ for therapeutic use and the suitable biological and chemical characteristics of chitosan, not to mention its ready producibility The amount of $^{166}Ho$-CHICO to be administered to obtain the goal therapeutic effect can be suggested by predicting the dose to the cyst wall for a varying pharmaceutical dose. When $^{166}Ho$-CHICO is infused into the cyst, the major part of the energy delivery by beta particles emitted from $^{166}Ho$ occurs in the cyst wall within 4mm in depth from the cyst wall surface. Also, realizing the attachment of $^{166}Ho$-CHICO to the cyst wall surface would change the predictions of dose to the cyst wall.

  • PDF

Rectal balloon for the immobilization of the prostate internal motion (전립선 내부 움직임 고정용 직장풍선)

  • Cho, Sam-Ju;Cho, Jae-Ho;Lee, Sang-Kyoo;Chu, Sung-Sil;Bak, Jin-Ho;Lee, Se-Byong;Jeong, Kyoung-Keun;Lee, Chang-Geol;Suh, Chang-Ok
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.136-139
    • /
    • 2004
  • In this study, we used the rectal balloon to overcome the dose limit of the radiation therapy in the prostate cancer. Using the rectal balloon, we could minimize the planning target volume (PTV) by minimizing the internal motion of prostate and increased the gap between the rectum wall and the high dose region. To this purpose, we analyzed the position reproducibility of rectal balloon during the patient setup. Moreover, we studied the clinical feasibility of rectal balloon by performing the IMRT plan.

  • PDF

Dosimetric and clinical review on the application of TOMO_edge mode (토모테라피 Edge 모드를 이용한 임상적 유용성 고찰)

  • Kim, Lizzy
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.177-182
    • /
    • 2014
  • Purpose : The goal of this study was to compare and analysis the dose distribution and treatment time between Tomotherapy planning with fixed jaw(FJ) and dynamic jaw(DJ). Materials and Methods : Seven patients were selected in the study including five common clinical cases(brain, head and neck(HN), lung, prostate, spine). 1) Helical Tomotherapy plans with FJ and DJ were generated with the same planning parameters such as Modulation factor, Pitch and Field width. 2) Tomo_edge plans with a larger field width were generated to compare to conventional HT delivery with fixed jaw. Dosimetric evaluation indices for target coverage are Dmin, Conformity index(CI) and for whole body including target are $V_{10%}$, $V_{25%}$, $V_{50%}$, $V_{75%}$ using Dose-volume histogram(DVH). Also, Treatment time and Cumulative MU were used for clinical review on Tomo_edge. Results : In case of using the same field width of Tomotherapy planning with FJ and DJ, the averaged variations were $V_{10%}$: -11.91%, $V_{25%}$: -7.6%, $V_{50%}$ :-4.75%, $V_{75%}$: -1.04%. Tomo_edge with a larger field width provides the averaged variations for target coverage: Dmin: -0.72%, CI: -1.25% and also shows the tendency of a sharp $V_{x%}$ decline in low dose area. The clinical improvements in the larger field width with DJ were observed in the treatment time, ranging from -51.21% to -15.11, and the Cumulative MU decrease, ranging from -57.74% to -15.31%. Conclusion : Target coverage achieved by FJ and DJ with the same field width has little differences. But integral doses on whole body efficiently decreased. Compared to the conventional HT delivery, Tomo_edge with a larger field width presents a little worse target coverage. However, it provides faster treatment delivery and improved cranial-caudal target dose conformity. Therefore, Tomo_edge mode is efficient in improving the treatment time and integral dose while maintaining comparable plan quality in clinic.

Evaluation of Tangential Fields Technique Using TOMO Direct Radiation Therapy after Breast Partial Mastectomy (유방 부분 절제술 후 방사선 치료 시 TOMO Direct를 이용한 접선 조사의 선량적 유용성에 관한 고찰)

  • Kim, Mi-Jung;Kim, Joo-Ho;Kim, Hun-Kyum;Cho, Kang-Chul;Chun, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • Purpose: Investigation of the clinical use of tangential fields technique using TOMO direct in comparison to conventional LINAC based radiation therapy after breast partial mastectomy. Materials and Methods: Treatment plans were created for 3 left-sided breast cancer patients who had radiation therapy after breast partial mastectomy by using wedged tangential fields technique, field in field technique (FIF), TOMO Direct, TOMO Direct intensity modulated radiation therapy (IMRT) under the normalized prescription condition ($D_{90%}$: 50.4 Gy/28 fx within CTV). Dose volume histogram (DVH) and isodose curve were used to evaluate the dose to the clinical target volume (CTV), organ at risk (OAR). We compared and analyzed dosimetric parameters of CTV and OAR. Dosimetric parameters of CTV are $D_{99}$, $D_{95}$, Dose homogeneity index (DHI: $D_{10}/D_{90}$) and $V_{105}$, $V_{110}$. And dosimetric parameters of OAR are $V_{10}$, $V_{20}$, $V_{30}$, $V_{40}$ of the heart and $V_{10}$, $V_{20}$, $V_{30}$ of left lung. Results: Dosimetric results of CTV, the average value of $D_{99}$, $D_{95}$ were $47.7{\pm}1.1Gy$, $49.4{\pm}0.1Gy$ from wedged tangential fields technique (W) and FIF (F) were $47.1{\pm}0.6Gy$, $49.2{\pm}0.4Gy$. And it was $49.2{\pm}0.4$ vs. $48.6{\pm}0.8Gy$, $49.9{\pm}0.4$ vs. $49.5{\pm}0.3Gy$ Gy for the TOMO Direct (D) and TOMO Direct IMRT (I). The average value of dose homogeneity index was W: $1.1{\pm}0.02$, F: $1.07{\pm}0.02$, D: $1.03{\pm}0.001$, I: $1.05{\pm}0.02$. When we compared the average value of $V_{105}$, $V_{110}$ using each technique, it was the highest as $34.6{\pm}9.3%$, $7.5{\pm}7.9%$ for wedged tangential fields technique and the value dropped for FIF as $16.5{\pm}14.8%$, $2.1{\pm}3.5%$, TOMO direct IMRT as $7.5{\pm}8.3%$, $0.1{\pm}0.1%$ and the TOMO direct showed the lowest values for both as 0%. Dosimetric results of OAR was no significant difference among each technique. Conclusion: TOMO direct provides improved target dose homogeneity over wedged tangential field technique. It is no increase the amount of normal tissue volumes receiving low doses, as oppose to IMRT or Helical TOMO IMRT. Also, it simply performs treatment plan procedure than FIF. TOMO Direct is a clinical useful technique for breast cancer patients after partial mastectomy.

  • PDF

Convolution-Superposition Based IMRT Plan Study for the PTV Containing the Air Region: A Prostate Cancer Case (Convolution-Superposition 알고리즘을 이용한 치료계획시스템에서 공기가 포함된 표적체적에 대한 IMRT 플랜: 전립선 케이스)

  • Kang, Sei-Kwon;Yoon, Jai-Woong;Park, Soah;Hwang, Taejin;Cheong, Kwang-Ho;Han, Taejin;Kim, Haeyoung;Lee, Me-Yeon;Kim, Kyoung Ju;Bae, Hoonsik
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.271-277
    • /
    • 2013
  • In prostate IMRT planning, the planning target volume (PTV), extended from a clinical target volume (CTV), often contains an overlap air volume from the rectum, which poses a problem inoptimization and prescription. This study was aimed to establish a planning method for such a case. There can be three options in which volume should be considered the target during optimization process; PTV including the air volume of air density ('airOpt'), PTV including the air volume of density value one, mimicking the tissue material ('density1Opt'), and PTV excluding the air volume ('noAirOpt'). Using 10 MV photon beams, seven field IMRT plans for each target were created with the same parameter condition. For these three cases, DVHs for the PTV, bladder and the rectum were compared. Also, the dose coverage for the CTV and the shifted CTV were evaluated in which the shifted CTV was a copied and translated virtual CTV toward the rectum inside the PTV, thus occupying the initial position of the overlap air volume, simulating the worst condition for the dose coverage in the target. Among the three options, only density1Opt plan gave clinically acceptable result in terms of target coverage and maximum dose. The airOpt plan gave exceedingly higher dose and excessive dose coverage for the target volume whereas noAirOpt plan gave underdose for the shifted CTV. Therefore, for prostate IMRT plan, having an air region in the PTV, density modification of the included air to the value of one, is suggested, prior to optimization and prescription for the PTV. This idea can be equally applied to any cases including the head and neck cancer with the PTV having the overlapped air region. Further study is being under process.

Palliative Irradiation Using Helical Tomotherapy in Recurrent Pelvic Tumors with Prior Radiotherapy (방사선치료 후 재발한 골반암에서 토모테라피를 이용한 고식적 재치료)

  • Kay, Chul-Seung;Yoo, Eun-Jung;Kim, Ji-Hoon;Ro, Duck-Young;Kim, Ki-Jun
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.133-140
    • /
    • 2010
  • Purpose: We retrospectively investigated the effect of irradiation using helical tomotherapy in recurrent pelvic tumors that underwent prior irradiation. Materials and Methods: Fourteen patients with recurrent pelvic tumors consisting of rectal cancer (57.1%), cervical cancer (35.7%) and cancer with an unknown origin (7.1%) were treated with tomotherapy. At the time of irradiation, median tumor size was 3.5 cm and 7 patients complained of pain originating from a recurrent tumor. The median radiation dose delivered to the gross tumor volume, clinical target volume, and planning target volume was 50 Gy, 47.8 Gy and 45 Gy, respectively and delivered at 5 fractions per week over the course of 4 to 5 weeks. Treatment response and duration of local disease control were evaluated using the Response Evaluation Criteria in Solid Tumors (ver. 1.0) and the Kaplan-Meyer method. Treatment-related toxicities were assessed through Common Terminology Criteria for Adverse Events (ver. 3.0). Results: The median follow-up time was 17.3 months, while the response rate was 64.3%. Symptomatic improvement appeared in 6 patients (85.7%). The median duration time of local disease control was 25.8 months. The rates of local failure, distant failure, and synchronous local and distant failure were 57.1%, 21.4%, and 7.1%, respectively. Acute toxicities were limited in grade I or II toxicities, except for one patient. No treatment related death or late toxicity was observed. Conclusion: Helical tomotherapy could be suggested as a feasible palliative option in recurrent pelvic tumors with prior radiotherapy. However, to increase treatment effect and overcome the limitation of this outcome, a large clinical study should be performed.

Effects of Arc Number or Rotation Range upon Dose Distribution at RapidArc Planning for Liver Cancer (간암환자를 대상으로 한 래피드아크 치료계획에서 아크수 및 회전범위가 선량분포에 미치는 영향)

  • Park, Hae-Jin;Kim, Mi-Hwa;Chun, Mi-Son;Oh, Yeong-Teak;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.165-173
    • /
    • 2010
  • In this paper, we evaluated the performance of 3D CRT, IMRT and three kind of RA plannings to investigate the clinical effect of RA with liver cancer case. The patient undergoing liver cancer of small volume and somewhat constant motion were selected. We performed 3D CRT, IMRT and RA plannings such as 2RA, limited triple arcs (3RA) and 3MRA with Eclipse version 8.6.15. The same dose volume objectives were defined for only CTV, PTV and body except heart, liver and partial body in IMRT and RA plannings. The steepness of dose gradient around tumor was determined by the Normal Tissue Objective function with the same parameters in place of respective definitions of dose volume objectives for the normal organs. The approach between the defined dose constraints and the practical DVH of CTV, PTV and Body was the best in 3MRA and the worst in IMRT. The DVHs were almost the same among RAs. Plans were evaluated using Conformity Index (CI), Homogeneity Index (HI) and Quality of coverage (QoC) by RTOG after prescription with dose level surrounding 98% of PTV in the respective plans. As a result, 3MRA planning showed the better favorable indices than that of the others and achieved the lowest MUs. In this study, RA planning is a technique that is possible to obtain the faster and better dose distribution than 3D CRT or IMRT techniques. Our result suggest that 3MRA planning is able to reduce the MUs further, keeping a similar or better targer dose homogeneity, conformity and sparing normal tissue than 2RA or 3RA.

3-Dimensional Conformal Radiation Therapy in Carcinoma of The Nasopharynx (비인강암의 3차원 입체조형치료에서 등가선량분포에 관한 연구)

  • Keum Ki Chang;Kim Gwi Eon;Lee Sang Hoon;Chang Sei Kyung;Lim Jihoon;Park Won;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.399-408
    • /
    • 1998
  • Purpose : This study was designed to demonstrate the potential therapeutic advantage of 3-dimensional (3-D) treatment planning over the conventional 2-dimensional (2-D) approach in patients with carcinoma of the nasopharynx. Materials and Methods : The two techniques were compared both qualitatively and quantitatively for the boost portion of the treatment (19.8 Gy of a total 70.2 Gy treatment schedule) in patient with T4. The comparisons between 2-D and 3-D plans were made using dose statistics, dose-volume histogram, tumor control probabilities, and normal tissue complication probabilities. Results : The 3-D treatment planning improved the dose homogeneity in the planning target volume. In addition, it caused the mean dose of the planning target volume to increase by 15.2$\%$ over 2-D planning. The mean dose to normal structures such as the temporal lobe, brain stem, parotid gland, and temporomandibular joint was reduced with the 3-D plan. The probability of tumor control was increased by 6$\%$ with 3-D treatment planning compared to the 2-D planning, while the probability of normal tissue complication was reduced. Conclusion : This study demonstrated the potential advantage of increasing the tumor control by using 3-D planning. but prospective studies are required to define the true clinical benefit.

  • PDF

Comparison of Dose Distribution in Spine Radiosurgery Plans: Simultaneously Integrated Boost and RTOG 0631 Protocol (척추뼈전이암 환자의 체부정위방사선치료계획 비교: 동시통합추가치료법 대 RTOG 0631 프로토콜)

  • Park, Su Yeon;Oh, Dongryul;Park, Hee Chul;Kim, Jin Sung;Kim, Jong Sik;Shin, Eun Hyuk;Kim, Hye Young;Jung, Sang Hoon;Han, Youngyih
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.176-184
    • /
    • 2014
  • In this study, we compared dose distributions from simultaneously integrated boost (SIB) method versus the RTOG 0631 protocol for spine radiosurgery. Spine radiosurgery plans were performed in five patients with localized spinal metastases from hepatocellular carcinoma. The computed tomography (CT) and T1- and T2-weighted magnetic resonance imaging (MRI) were fused for delineating of GTV and spinal cord. In SIB plan, the clinical target volume (CTV1) was included the whole compartments of the involved spine, while RTOG 0631 protocol defines the CTV2 as the involved vertebral body and both left and right pedicles. The CTV2 includes transverse process and posterior element according to the extent of GTV. The doses were prescribed 18 Gy to GTV and 10 Gy to CTV1 in SIB plan, while the prescription of RTOG 0631 protocol was applied 18 Gy to CTV2. The results of dose-volume histogram (DVH) showed that there were competitive in target coverage, while the doses of spinal cord and other normal organs were lower in SIB method than in RTOG 0631 protocol. The 85% irradiated volume of VB in RTOG 0631 protocol was similar to that in the SIB plan. However, the dose to normal organs in RTOG 0631 had a tendency to higher than that in SIB plan. The SIB plan might be an alternative method in case of predictive serious complications of surrounded normal organs. In conclusion, although both approaches of SIB or RTOG 0631 showed competitive planning results, tumor control probability (TCP) and normal tissue complication probability (NTCP) through diverse clinical researches should be analyzed in the future.

The dosimetric guide of treatment modalities for Left side breast irradiation after conservative surgery (좌측 유방암 방사선 치료 시 치료 기법에 따른 선량적 고찰)

  • Kim, Tae Min;Moon, Sung Kong;Kim, Li Zzy;Kim, Se Young;Park, Ryeung Hwang;Kim, Joo Ho;Cho, Jung Heui
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.153-160
    • /
    • 2018
  • Purpose : We retrospectively analyzed doses of each radiation therapy technique used in the treatment for left breast cancer patients after partial mastectomy through dose results for normalorgans and tumor volume to use this as a clinical reference for radiation therapy of domestic left breast cancer patients. Materials and Methods : 40 patients who underwent partial mastectomy on left breast cancer were classified in 3 treatment methods. The treatment plan was evaluated by HI(homogeneity index), $D_{95%}$, and CI(conformity index), and the $V_{hot}$ for gross tumor volume and clinical target volume of each treatment method. In Cyberknife treatment, tumor volume was the same as high dose volume in the other techniques, so no consideration was given to clinical target volume. Treatment plan evaluation for normal organs were evaluated by mean dose on ipsilateral lung, heart, left anterior descending artery, opposite breast and lung, and non-target tissue. Result : Treatment with volumetric arc radiotherapy(VMAT) showed $95.84{\pm}0.75%$ of $D_{95%}$ on the clinical target volume, significantly higher than that of 3D-CRT. The $D_{95%}$ value of the total tumor volume was slightly higher than the other treatments. In Cyberknife treatment, the dose to the normal organs was significantly lower than other treatments. Overall, the maximum dose and mean dose to the heart were $26.2{\pm}6.12Gy$ and $1.88{\pm}0.2Gy$ in VMAT treatment and $20.25{\pm}9.35Gy$ and $1.04{\pm}0.19Gy$ in 3D-CRT therapy, respectively. Conclusion : In comparison on 3D-CRT and VMAT, most of the dosimetric parameters for the evaluation of the treatment plan showed similar values, so that there is no significant difference in treatment plan evaluation. It is possible to select the treatment method according to the patient's anatomical structure or possibility of breath control. Cyberknife treatment is very useful treatment for normal organs because of its accurate dose exposure to the tumor volume However, it has restrictions to treat the local area, to have relatively long treatment time and to involve invasive procedure.

  • PDF