• Title/Summary/Keyword: 일축인장시험

Search Result 74, Processing Time 0.021 seconds

압입시험 기법을 이용한 인장물성 평가

  • Kim, Sung-Hoon;An, Jung-Hoon;Choi, Yeol;Jeon, Eun-Chae;Kwon, Dong-Il
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.11a
    • /
    • pp.3-8
    • /
    • 2000
  • 현재 재료의 기계적 특성을 평가하기 위한 가장 표준화된 방법은 일축인장시험이다. 일축인장시험은 다양한 기계적 물성을 제공하나, 일정 크기 이상의 시편을 요구하므로 실제 산업현장에서 사용되고 있는 구조물의 안전성 평가에 이용하기 어렵다. 이러한 단 점을 개선할 수 있는 시험법으로 최신압입시험법이 제안되었다.(중략)

  • PDF

Tensile Strength Measurement on Compacted Sand-Bentonite Mixtures (다짐된 모래-벤토나이트 혼합토의 인장강도 측정)

  • Jung, Soo-Jung;Kim, Tae-Hyung;Kim, Chan-Kee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6C
    • /
    • pp.377-384
    • /
    • 2006
  • Theoretical and experimental study of the unconfined penetration (UP) test was conducted to suggest a new test method (referred to as IUP, Improved Unconfined Penetration) for determination of the tensile strength of compacted sand-bentonite mixtures. The tensile strength of compacted mixtures can be calculated from limit analysis based on the theory of perfect plasticity. The measurement errors in new test method were reduced by improving the UP device. Preliminary experiment results indicate that the tensile strength increases with increasing the disk size, loading rate and pH level. In addition, the disk diameter with 25.4 mm and the loading rate with 0.5%/min~1%/min are most suitable condition for the IUP test. The reliability of IPU test was verified by through the fact that good agreement between the IUP and conventional split tensile test results is observed.

A Comparative Study on the Tensile Strength of Frozen Soil according to Test Methods (시험 방법에 따른 동결토의 인장강도)

  • Seo, Young-Kyo;Kang, Hyo-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.4
    • /
    • pp.57-66
    • /
    • 2008
  • In this study, the blast-induced vibration effects on the structural stability of the adjacent tunnel and the stability were estimated with respect to the allowable peak particle velocity (PPV). The blasting distance from the tunnel satisfying the allowable PPV was estimated based on the analytical solutions, United States Bureau of Mines (USBM) suggestions, and the equations used in the subway in Seoul. The allowable blasting distance was estimated by using finite difference analysis (FDA) and the behavior of the concrete lining and rock bolts was examined and the stability of those was estimated during the blast. Research results show that the blast-induced vibration effects on the structural stability are negligible for the concrete lining but relatively large for the rock bolts.

Characterization of Tensile Strength of Anisotropic Rock Using the Indirect Tensile Strength Test (간접인장강도시험을 통한 이방성 암석의 인장강도 특성)

  • 김영수;정성관;최정호
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.5
    • /
    • pp.133-141
    • /
    • 2002
  • Isotropic rock and anisotropic rock have different tensile strength which has the greatest influence on rock failure. In this study, elastic modulus of anisotropic rock is obtained through uniaxial compression test, and tensile strength and tension failure behavior are analyzed through indirect tensile strength test. Stress concentration factor of a specimen at the center is obtained from anisotropic elastic modulus and strain by indirect tensile strength test. Theoretical solutions for tensile strength of isotropic and anisotropic rock are compared. Stress concentration factor of anisotropic rock is either higher or lower than isotropic rock depending on the inclination angle of bedding plane. The use of stress concentration factor of isotropic rock resulted in overestimation or underestimation of tensile strength.

Analysis of Influence factors to Compressive and Tensile Strength of Basalt in Cheju Island (제주도 현무암의 압축 및 인장강도에 대한 영향요인 분석)

  • Nam, Jung-Man;Yun, Jung-Mann;Song, Young-Suk;Kim, Jun-Ho
    • The Journal of Engineering Geology
    • /
    • v.18 no.2
    • /
    • pp.215-225
    • /
    • 2008
  • In order to investigate the influence factors to compressive and tensile strength of basalt in Cheju Island, rock samples of Pyosenri basalt, trachy-basalt and scoria were taken from Seoguipo-Si Seongsan-Eup area, and a series of uniaxial compressive strength test and Brazilian test were carried out. Especially, these tests were performed in consideration of the loading speed, the moisture content in rock sample, and the anisotropy of rock strength. The uniaxial compressive strength was increased gradually as the loading speed rose. The increasing quantity of uniaxial compressive strength had a difference in each rock types. Also, the strength was decreased with increasing the moisture contents in rock sample by pore water. As the result of test considering the anisotropy of rock strength, the compressive strength in condition of failure occurred parallel to stratified layer is decreased about 12-26% more than that in condition of failure occurred inclined to stratified layer.

Simplified Estimation of the Cohesion and Internal Friction Angle of Volcanic Intact Rocks in Jeju Island Using Uniaxial Compressive Strength and/or Brazilian Tensile Strength (일축압축강도·압열인장강도를 이용한 제주도 화산암의 점착력과 내부마찰각의 간이추정)

  • Yang, Soonbo
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.10
    • /
    • pp.5-15
    • /
    • 2022
  • In this study, to propose simplified methods for estimating the cohesion and internal friction angle of volcanic rocks in Jeju Island using uniaxial compressive strength and/or Brazilian tensile strength, the estimated values of cohesion and internal friction angle from triaxial and uniaxial compression tests and Brazilian tests were compared in terms of estimation accuracy. This study proposed simplified methods for estimating the cohesion and internal friction angle using the uniaxial compressive strength and/or Brazilian tensile strength of volcanic rocks in Jeju Island. According to the findings, among the proposed simplified methods, the method using uniaxil compressive strength was most desirable to accurately estimate the cohesion and internal friction angle of volcanic intact rocks in Jeju Island.

Splice Performance Evaluation of Fastening Coupler According to the Slope Length of Internal Fasteners (조임쇠 경사길이에 따른 체결식 커플러의 이음성능 평가)

  • Jung, Hyun-Suk;Choi, Chang-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.11-19
    • /
    • 2022
  • In this study, in order to improve the splice performance of mechanical couplers, two new mechanical couplers with different connection modes were developed with rebar(SD400). The stress analysis of mechanical couplers with two different connection modes was carried out. Uniaxial tensile tests were carried out with type of steel, connection mode and the slope length of internal fastener as variables to analyze the influence on the maximum tensile strength. Building upon this previous work, the specimens that met the code in uniaxial tensile test were fabricated and static loading test and cyclic loading test were performed on the basis of Korean code(KS D 0249). The results of this research are as follows; (1) The tensile strength of steel and the slope length of internal fasteners have a certain influence on the maximum tensile strength. (2) The connection mode has some influence on the stiffness, slip and stiffness reduction rate of the connecting rebars. The results verify the feasibility of the proposed enhanced mechanical coupler in the field.

Study on the Direct Tensile Test for Cemented Soils Using a Built-In Cylinder (내장형 실린더를 이용한 시멘트 고결토의 인장시험 방법에 관한 연구)

  • Park, Sung-Sik;Lee, Jun-Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1505-1516
    • /
    • 2014
  • In this study, a cylinder embedded within cemented soils was used to cause directly tensile failure of cemented soils. An existing dumbbell type direct tensile test and a split tensile test that is most general indirect tensile test were also carried out to verify the developed built-in cylinder tensile test. Testing specimens with two different sand/cement ratios (1:1 and 3:1) and two curing periods (7 and 28 days) were prepared and tested. Total 10 specimens were prepared for each case and their average value was evaluated. Unconfined compression tests were also carried out and the ratio of compressive strength and tensile strength was evaluated. The tensile strength determined by built-in cylinder tensile test was slightly higher than that by dumbbell type direct tensile test. The dumbbell type test has often failed in joint part of specimen and showed some difficulty to prepare a specimen. Among three tensile testing methods, the standard deviation of tensile strength by split tensile test was highest. It was shown that the split tensile test is applicable to concrete or rock with elastic failure but not for cemented soils having lower strength.

Influence of Rock Inhomogeneity on the Static Tensile Strength of Rock (암석의 정적 인장강도에 미치는 불균질성의 영향)

  • Cho, Sang-Ho;Yang, Hyung-Sik;Katsuhiko Kaneko
    • Tunnel and Underground Space
    • /
    • v.13 no.2
    • /
    • pp.117-124
    • /
    • 2003
  • The fracture processes under static tensile loading were simulated using a proposed numerical simulation method, based on finite element method and fracture mechanism, and analyzed to verify an influence of rock inhomogeneity on static tensile strength. Static tensile strengths for the specimen models with different spatial microscopic tensile strength when m=5 and m=50 were estimated. These analyses revealed that the static tensile strength becomes closer to the mean microscopic tensile strength at a higher uniformity coefficient and the scatter of the strength data decreases in increasing the uniformity coefficients. Therefore, it could be concluded that rock inhomogeneity has an effect on static tensile strength.

An Evaluation on Toughness of Ductile Fiber Reinforced Cementitious Composite according to Thickness and restrained method (시험체 형상 및 시험방법에 따른 고인성 콘크리트의 인장특성 평가에 관한 연구)

  • Park, Yun-Mi;Kim, Young-Duck;Kim, Young-Bong;Jeong, Jae-Hong;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.469-472
    • /
    • 2008
  • As a general rule, concrete has higher compression strength than bending and toughness. but Ductile fiber reinforced cementitious composite has high toughness property owing to adding a large volume fiber. Therefore uniaxial tensile strength test is imperative to evaluate high toughness property of ductile fiber reinforced cementitious composite in comparison with general concrete test. but in testing compression strength, Result is different by factor of thickness, shape and edge condition. Uniaxial tensile strength test is affected by fiber's length and section area because of cementitious composite property and factor of fiber arrangement. This study evaluates toughness property of ductile fiber reinforced cementitious composite according to thickness and edge condition. The more thickness is thin, the more high performance by fiber arrangement

  • PDF