• Title/Summary/Keyword: 일원배치분산분석

Search Result 286, Processing Time 0.022 seconds

Comparison of marginal and internal fit of zirconia abutments with titanium abutments in internal hexagonal implants (내부육각 연결형 임플란트에서 지르코니아 지대주와 티타늄 지대주의 변연 및 내면 적합도의 비교)

  • Kim, Young-Ho;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.93-102
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the fit accuracy of two zirconia and titanium abutments in internal hexagonal implants. Materials and methods: One titanium abutment and two zirconia abutments were tested in internal hexagonal implants (TSV, Zimmer). Prefabricated zirconia abutments (ZirAce, Acucera) and customized zirconia abutments milled by the Zirkonzahn system (Zirkonzahn Max, Zirkonzahn) were selected and prefabricated titanium abutments (Hex-Lock, Zimmer) were used as a control. Eight abutments per group were connected to implants with 30 Ncm torque. The marginal gaps at abutment-implant interface, the internal gaps at internal hex, vertical and horizontal gaps between screws and screw seats in abutments were measured after sectioning the embedded specimens using a scanning electron microscope. Data analysis included one-way analysis of variance and the Scheffe test (n=16, ${\alpha}=0.05$). Results: The mean marginal gap of customized zirconia abutment was higher than those of two prefabricated zirconia and titanium abutments. The internal gaps at internal hex showed no significant differences between customized and prefabricated abutments and were higher than those of prefabricated titanium abutments. The mean vertical and horizontal gaps at screw in prefabricated zirconia abutment were higher than those of prefabricated titanium abutment. In the case of customized zirconia abutment, the mean horizontal gap at screw was higher than those of both the prefabricated zirconia and the titanium abutment but the mean vertical gap was not even measureable. The screw seats were clearly formed but did not match with abutment screws in prefabricated zirconia abutments. They were not, however, precisely formed in the case of customized zirconia abutments. Conclusion: Within the limitations of this study, the prefabricated titanium abutments showed better fit than the zirconia abutments, regardless of customized or prefabricated. Also, the customized zirconia abutments showed significantly higher marginal gaps and the fit was less accurate between screws and screw seats than the prefabricated abutments, titanium and zirconia.

Design and Fabrication for the Development of Auto Pattern Maker (자동취형기 개발을 위한 설계 및 제작)

  • Lee, Young-Il;Kim, Jung-Hee;Park, Jee-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.231-239
    • /
    • 2013
  • Purpose: To design and fabricate the auto pattern maker for the development. Methods: we got the necessary data, needed in design, by using CAD. Based on the these data, we fabricated the trial product for the development of the auto pattern maker. Results: The auto pattern maker were composed with combinations of many elements; pattern making assembly, control panel, frame attachment and prober unit. The pattern making assembly was comprised of the cutter, the pattern holder, pattern remover and silence cover which could minimize the sound during the cutting process. The control panel was designed to be connected and operated with the main printed circuit board. The prober could get the eye shape data by scanning of 1.8 degrees around the groove of the frame through the encoding data according to the address. After starting, scanning was carried out in two passes, i.e. one right-handed and one left-handed. Communication connector could send the eye shape data from auto pattern maker to outer system with the RS232C transmission system. By using the one-way analysis of variance, we got the error rate of cut pattern size for ${\Phi}22mm$, ${\Phi}55mm$ and ${\Phi}62mm$. Because F-value was 0.510 and p-value was 0.601, no statistically significant differences were found. Also, the mean cutting error of the auto pattern maker was 0.0274 mm. Conclusions: we could succeed in making the trial product by applying it to the development of the auto pattern maker. The role of this auto pattern maker is to find a exact required size of lens to fit the frame by measuring the frame. The acquired data are transferred to outer system for grinding and finishing with patternless process. Also, the trial product can produce pattern to fit the frame. Therefore, it was confidently expected that the optometrists could handily produce pattern to fit the frame with this trial product and dispense the ophthalmic lens because of its efficiency and convenience compared to the past.

Comparison of the Working Conditions of Dental Hygienists Using Data from Online Job Sites (구인 사이트에 나타난 치과규모별 치과위생사 근무조건의 비교)

  • Oh, Eun-Ju;Hwang, Soo-Jeong
    • Journal of dental hygiene science
    • /
    • v.17 no.6
    • /
    • pp.501-507
    • /
    • 2017
  • The shortage of dental hygienists has been a long-standing problem in Korea. Small-scaled dental clinics suffer from a lack of dental hygienists, who seem to prefer working at large-scaled dental clinics. The purpose of this study was to confirm the differences in the working conditions according to the scales of dental clinics. We collected the working information registered via job advertisements through the web-sites of Korean Dental Hygienists Association, Dental Jobs, and Nurse Jobs from July to August 2016. The results were as follows: 96.7% of the advertisements wanted regular workers, while the proportion of part-time workers was the highest (34.8%) in the group with less than 3 employees. The average workdays per week was $5.32{\pm}0.55$ days, and the group with less than 3 employees had significantly longer workdays than the other groups. The daily working time was $8.99{\pm}0.44$ hours, and there was no difference among the groups. Night overtime hours were needed by 54.4%, 45.0%, and 31.3% of the groups with of the groups with 4~7 employees, more than 8 employees, and less than 3 employees, respectively. Information regarding annual leave (60.5%), monthly leave (63.9%), half a day off (32.4%) and vacations (43.1%) were presented in the job advertisements, and these proportions were significantly higher by the group with more than 8 employees. Information on overtime pay (14.4%), night-work pay (13.4%), incentives (34.1%), lunches (60.2%), vacation bonuses (33.8%), and self-development (20.4%) were presented in job advertisements. The group with 4~7 employees had significantly higher proportions in severance pay, vacation bonuses, self-development, and major national insurance. It is necessary to consider the improvement of working conditions, diversity of working styles, and welfare of dental hygienists, and it is suggested that small dental clinics provide more precise working conditions.

Physical properties of novel composite using Portland cement for retro-filling material (치근단 역충전용 포틀랜드 시멘트 신복합재료의 물리적 성질 고찰)

  • Lee, Sang-Jin;Cho, Ok-In;Yum, Ji-Wan;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.445-452
    • /
    • 2010
  • Objectives: The aim of this study was to compare apical sealing ability and physical properties of MTA, MTA - AH-plus mixture (AMTA) and experimental Portland cement - Epoxy resin mixture (EPPC) for a development of a novel retro-filling material. Materials and Methods: Forty-nine extracted roots were instrumented and filled with gutta-percha. Apical root was resected at 3 mm and the retro-filling cavity was prepared for 3 mm depth. Roots were randomly divided into 3 groups of 15 roots each. The retro-filling was done using MTA, AMTA, and EPPC as the groups divided. Four roots were used as control groups. After setting in humid condition for 24 hours, the roots were immersed in 1% methylene blue dye solution for 72 hours to test the apical leakage. After immersion, the roots were vertically sectioned and photos were taken to evaluate microleakage. Setting times were measured with Vicat apparatus and digital radiographs were taken to evaluate aluminum equivalent thickness using aluminum step wedge. The results of microleakage and setting time were compared between groups using one-way ANOVA and Scheffe's post-hoc comparison at the significance level of 95%. Results: AMTA and EPPC showed less microleakage than MTA group (p < 0.05). AMTA showed the highest radio-opacity than other groups and the novel EPPC showed 5 mm aluminum thickness radio-opacity. EPPC showed the shortest initial and final setting times than other groups while the MTA showed the longest (p < 0.05). Conclusions: Under the condition of this study, the novel composite using Portland cement-Epoxy resin mixture may useful for retro-filling with the properties of favorable leakage resistance, radio-opacity and short setting time.

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

Does Sarcopenic Obesity Affect Physical Function and Physical Fitness of Korean Older Women? (근위축비만이 국내 여성고령자의 신체기능과 체력에 미치는 영향)

  • Hong, Seung-youn
    • 한국노년학
    • /
    • v.30 no.3
    • /
    • pp.831-842
    • /
    • 2010
  • BACKGROUND: Sarcopenic obesity(SO), a condition of the reduction in muscle mass paired with an increased fat mass has been paid attention because of its association with disability in later life. A few evidence, however, has reported the association with these factors. PURPOSE: To explore the association among SO, physical function and fitness in older women. METHOD: 257 older women(age of 74) were recruited from Y city and 7 physical functions and 4 fitness tests were measured. Participants were classified into one of four groups based on their body fat and muscle mass: Normal group (GR-A), high fat(GR-B), sarcopenia(GR-C), and sarcopenic obese(GR-D). GLMand LSD-test were conducted with SPSS 12.0. RESULTS: Chair stand, arm-curl, back-scratch, 2-min steps of GR-A was higher than GR-C and GR-D(p<.05). One-leg stand of GR-A was higher than GR-D(p<.01) and of GR-C was higher than GR-D(p<.01).8ft-TUG of GR-D was lower than GR-A(p<.01). Grip strength, knee extension of GR-A was higher than that of GR-C and GR-D(p<.01) and knee flexion of GR-A was also higher than that of GR-C and GR-D(p<.01). CONCLUSION: Based on our findings, we conclude that SO is significantly associated with lower physical function and fitness in older Korean women, which alarm the risk of frailty induced by SO.

Study on recognition, knowledge, and intake behavior of foods containing caffeine of high school students in Gyeongbuk region (카페인 함유식품에 대한 경북 지역 고등학생의 인식, 지식 및 섭취행동에 관한 연구)

  • Lee, Su-Jin;Kim, Hyochung;Kim, Meera
    • Journal of Korean Home Economics Education Association
    • /
    • v.26 no.4
    • /
    • pp.21-34
    • /
    • 2014
  • This study examined the levels of recognition, knowledge, and intake behavior of foods containing caffeine and analyzed the factors affecting amount of caffeine intake to get basic materials for development of educational program for proper intake behavior of foods containing caffeine of high school students in Gyeongbuk region. Of 300 questionnaires that were distributed on December 27, 2013 to February 14, 2014, 255 responses were used for analysis. Frequency distributions, Cronbach's ${\alpha}$, t tests, one-way ANOVA, Pearson's correlation analysis, and regression analysis were conducted by SPSS Windows V.21.0. The mean of the level of concern about foods containing caffeine was 2.76/5.00 points; male and second and third grade students showed lower concern level than female and first grade students. The respondents answered that intake of foods containing caffeine had somewhat harmful effect on health, but it did not much help to refresh and increase concentration. The mean for the percentage of correct answers about knowledge of caffeine was 54.3. Small number of the respondents were advised to reduce intake of caffeine from school teachers or parents. The average of caffeine intake amount was 71.67mg/day; the average for male was 78.98mg/day, whereas for female 61.23mg/day. Almost thirteen percentage of the respondents took caffeine over RDA(Recommended Daily Allowance). According to the result of regression analysis for amount of caffeine intake, grade, BMI, concern about health, perception of whether foods containing caffeine help with refreshment and increase of concentration or not, and experiences of having advice from school teachers to decrease caffeine intake were significant. These results imply that it is necessary for high school students to educate how to take caffeine properly.

  • PDF

Development of Analysis Method for Cholesterol in Infant Formula by Direct Saponification (직접 검화법을 이용한 조제분유의 콜레스테롤 분석법 개발)

  • Kim, Jin-Man;Park, Jung-Min;Yoon, Tae-Hyung;Leem, Dong-Gil;Yoon, Chang-Yong;Jeong, Ja-Young;Jeong, In-Seek;Kwak, Byung-Man;Ahn, Jang-Hyuk
    • Food Science of Animal Resources
    • /
    • v.31 no.6
    • /
    • pp.944-951
    • /
    • 2011
  • An improved cholesterol analysis method was developed for powdered infant formula by gas chromatographic separation after liquid-liquid extraction and partition. In the official Korea Food Standard method for cholesterol analysis, the water phase and solvent phase were not well separated in the case of emulsified foods such as powdered infant formulas and baby foods. For the rapid and simple sample preparation method, an optimized direct saponification condition was established for heating temperature, heating time, and KOH concentration. From the results, the optimum conditions were as follows: heating temperature $90^{\circ}C$, heating time 60 min, and 16 M KOH 10 mL for a 2 g infant formula sample; improved separation condition for gas chromatography was as follows: the initial oven condition was $250^{\circ}C$ for 25 min, the oven temperature was increased to $290^{\circ}C$ by $10^{\circ}C$/min ratio, and finally the oven temperature remained at $290^{\circ}C$for 9 min. The developed method could be implemented for the study of cholesterol, providing the advantages of reduced inspection time and cost in emulsified foods such as infant formula.

The Effects of Different Types of Treatment on EPOC and Anti-Oxidant Systems after Horseback Riding Exercise (승마기구운동 후 서로 다른 회복처치가 초과산소섭취량 및 항산화력에 미치는 영향)

  • Kim, Cheol-Woo;Baek, Yeong-Ho;Kwak, Yi-Sub
    • Journal of Life Science
    • /
    • v.21 no.11
    • /
    • pp.1612-1618
    • /
    • 2011
  • The present study was undertaken to analyze the effects of different types of treatment on excess post exercise oxygen consumption (EPOC), flexibility, free radical and antioxidants in women using a horseback riding therapeutic device. Subjects were trained in regular horseback riding exercises for 12 weeks (3 times/wk). The effects of this exercise were examined by means of a single session of horseback riding that lasted for 30 min. 21 women were recruited from a public health center and divided into 3 groups (passive recovery group, passive+massage recovery group, and dynamic recovery group). 3 types of recovery patterns were determined after a single trial of horseback riding exercise. Their flexibility were determined pre-and post-training by Paired T test, and ANOVA were used to analyze the data. The results were as follows: Among the 3 groups, the dynamic recovery group showed the highest levels of EPOC compared to the other groups, and also showed higher levels of anti-oxidants, as did the passive+massage recovery group compared to the passive recovery group. Moreover, horseback riding exercise greatly increased flexibility in the women. In conclusion, regular horseback riding training is recommended to enhance the flexibility of women and dynamic recovery is recommended to enhance EPOC and anti-oxidants after a single bout of exercise. Further study is needed in this area.

Morningness-Eveningness Affects the Depressive Mood and Day Time Sleepiness of Obstructive Sleep Apnea Syndrome Patient (폐쇄성 수면무호흡증 환자에서 일주기 리듬 특성에 따른 주간 졸음과 우울감의 차이)

  • Kim, Seong Ho;Joo, Eun-Jeong;Lee, Kyu Young;Koo, Young Jin;Kim, Eui-Joong
    • Sleep Medicine and Psychophysiology
    • /
    • v.19 no.2
    • /
    • pp.77-83
    • /
    • 2012
  • Objectives: Recent studies have reported a correlation between obstructive sleep apnea syndrome (OSA) and depression. In attempt to verify the suggestion that eveningness is related to depression, we examined the effect of morningness-eveningness on their depressive mood in patinets with OSA. Methods: The examination was based on the medical records and polysomnography reports of 211 OSA patients. Information was gathered from the patients who filled out the H$\ddot{o}$rne and Ostberg questionnaire (HOQ), profile of mood states-Korean version (K-POMS), and Epworth sleepiness scale (ESS). We compared mean values of K-POMS total, subscales of K-POMS, ESS, and OSA severity variables among the 3 morningness-eveningness groups (morningness, eveningness, and neither groups). Partial correlation analysis was performed between variables and ANCOVA was performed among the 3 groups after adjustment with age and weight. Results: There were significant negative correlations between HOQ and the followings : K-POMS total, POMS-T (tension-anxiety), POMS-D (depression-dejection), POMS-A (anger-hostility), POMS-F (fatigue-inertia), POMS-C (confusion-bewilderment), spontaneous arousal index, average O2 saturation. There were significant positive correlations between HOQ and the followings : POMS-V (vigor-activity), apnea-hypopnea index, respiratory arousal index, snore time. There were significant negative correlations between POMS-D and the followings : HOQ, POMS-V, stage 1 sleep (%), AHI, TAI (total arousal index), oxygen desaturation index, respiratory arousal index, neck circumference, average O2 desaturation, snore time (%). There were significant positive correlations between POMS-D and K-POMS total, POMS-T, POMS-A, POMS-F, POMS-C, sleep latency, stage 2 sleep (%), heart rate, spontaneous arousal index. There were significant differences in K-POMS total, POMS-T, POMS-D, POMS-F, POMS-C, spontaneous arousal index among the three HOQ groups in ANCOVA. Conclusion: The depressive correlates of OSA patients might be affected, not by excessive daytime sleepiness or OSA severity indexes, but by eveningness circadian characteristics. It would be important to take into account the morningness-eveningness tendency when we manage the depressive mood of OSA patients.