창호의 열관류율, 일사취득계수와 향의 배치가 건물의 냉난방 부하에 미치는 영향에 관한 지역별 비교연구 (Comparative Analysis on the Heating and Cooling Loads Associated with U-value, SHGC and Orientation of the Windows in Different Regions)

  • 최민서;장성주
    • KIEAE Journal
    • /
    • 제13권2호
    • /
    • pp.123-130
    • /
    • 2013
  • The primary goal of this research is to identify the impacts of window design on the energy use in buildings which takes up about 25% of the total energy consumption. Recently, efficient use of energy is gaining more importance in buildings. Window design, especially being dependent on glazing performance choices, is an important factor for reducing energy consumption in most of the buildings. It also is influenced by the latitude of the site and window orientation. This paper aims at identifying the influence of Window performance indicators(U-value, SHGC), orientation and latitude on the building energy consumption with systematically designed simulations. Comparative study has been performed for five different locations; Greenland, Korea, Singapore, Argentina and Chile along with the different window U-value and SHGC values. The results show that optimum window system with properly coordinated window performance indicators(U-value, SHGC), orientation achieves dramatic reduction of energy consumptions. Windows with low U-value could reduce heating loads and high SHGC could reduce cooling loads. The study also verifies that the windows installed at south facade is more energy efficient in the northern hemisphere while windows facing north is more energy efficient in the southern hemisphere.

건물 외피의 열특성과 외주부 깊이에 따른 PAL에 관한 연구 (A study on the PAL according to thermal characteristic of building skin and perimeter zone depth)

  • 김지혜;김환용
    • 한국태양에너지학회 논문집
    • /
    • 제30권2호
    • /
    • pp.33-38
    • /
    • 2010
  • The perimeter zone is space which receives a significant effect of ambient condition, it is necessary to improve the thermal performance in order to building energy saving. For this reason, a lot of study about the active approach is being performed, such as perimeter-less air conditioning system. But the performance of the perimeter zone is necessary to improve, through the passive approach. Therefore, the purpose of this study is to provide basic materials of energy-saving design of perimeter zone, based of the PAL that simulation changing the thickness of insulation and the rate of windows.

드론을 활용한 지표온도와 흡수일사 간 공간적 상관관계 분석 - 쿨루프 효과 분석을 중심으로 - (Analysis of Spatial Correlation between Surface Temperature and Absorbed Solar Radiation Using Drone - Focusing on Cool Roof Performance -)

  • 조영일;윤동현;이명진
    • 대한원격탐사학회지
    • /
    • 제38권6_2호
    • /
    • pp.1607-1622
    • /
    • 2022
  • 본 연구의 목적은 도시폭염 저감을 위한 기법인 쿨루프를 연구지역에 적용하여 토지피복 객체 간 지표 온도와 흡수일사 간 공간적 상관관계 분석으로 실질적 효과 파악을 목적으로 한다. 이를 위해 실제 쿨루프가 적용된 경상남도 김해시 장유무계동 인근을 연구지역으로 선정하였으며, 드론 DJI Matrice 300 RTK에 열적외 영역센서 FLIR Vue Pro R, 가시광선 영역센서 H20T와 다중분광영역 센서인 Micasense Red-Edge를 활용하여 계측하였다. 계측 일정은 2021년 7월 27일 아침 7시 15분부터 약 1시간 30분 간격으로 총 9장의 열지도와 동일 시간대의 흡수일사 분포도, 쿨루프(113개) 및 일반옥상(367개) 지붕 객체를 추출하였다. 흡수일사 분포도는 ArcGIS의 3D 분석 기능인 Solar Radiation Analysis Tool을 통해 산출한 전천일사 분포도에 Micasense Red Edge를 통해 촬영한 Blue, Green Red, Near Infrared, Red Edge Range 영역대 센서의 조합을 통해 구축한 연구 지역의 알베도 값을 반영하여 구축한다. 전술된 자료를 기반으로 일반옥상과 쿨루프 지붕 객체별 지표온도와 흡수일사 간 Pearson 상관계수를 산출하였다. 분석 결과 일 평균 기준 일반옥상 0.550, 쿨루프 0.387의 상관계수 값을 나타내고 있었다. 하지만, 시간대별 상관성의 변화를 파악한 결과 분석일 기준 태양고도가 높은 시기인 11시 30분과 13시의 경우 일반옥상과 쿨루프 간 상관계수의 차이는 0.022, 0.024 값을 보여 유사한 상관성을 보이고 있다. 그 외 시간대는 일반옥상의 상관계수 값이 쿨루프 보다 약 0.1 이상 높은 값을 보이고 있다. 본 연구는 드론을 통해 취득한 고해상도 영상을 활용하여 쿨루프의 실질적 일사차단 영향의 가능성을 대조군이 되는 일반 옥상과의 상관성 비교를 통해 파악한 사례 연구이다. 향후 본 연구 결과를 기반으로 효율적인 도시열섬 저감기법 적용이 가능할 것으로 사료된다.

주택 창의 SHGC가 에너지소비에 미치는 영향에 관한 연구 (A study of Energy use Impacts by SHGCs of Windows in Detached House)

  • 박률;박종일
    • 설비공학논문집
    • /
    • 제22권4호
    • /
    • pp.189-196
    • /
    • 2010
  • U-factor and solar heat gain coefficient(SHGC) usually can be used as the index to evaluate the thermal performance. U-factor is a concept for heat loss by the temperature difference between inside and outside, so it's useful to be applied in heating season. But SHGC that indicates the fraction of heat from incident solar radiation that flows through a window by means of optical transmission, as well as absorption, re-radiation and convection is for cooling season. In other words, U-factor and SHGC of windows by cities have to be reflected to select the window of the energy conservation. The purpose of this research is to analyze the energy use impacts by SHGCs of windows for detached house in Inchon and Ulsan through energy simulation by eQUEST.

Glazing 특성에 따른 고층 오피스 건물의 에너지성능 분석 (The Analysis on Energy Performance according to Characteristics of Glazing in High-rise Office Buildings)

  • 황우진;김교준;최원기
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.156-161
    • /
    • 2011
  • In case of newly constructed buildings, the construction type is almost Curtain-wall system or large window in building skin. However, these kind of buildings have problems with regulations on building energy efficiency. And national regulations on building energy efficiency limit only the V-factor of window(except infiltration), it is hard to predict energy consumption of Curtain-wall buildings which gain large solar energy in summer. In this study, the influence of LSG(Light to Solar Gain) on energy performance was theoretically analyzed with simulation. LSG is the value of VLT divide SHGC and represents the optical performance of the glass or glazing. The Window & Therm program developed in LBNL was used to analyze window systems and EnergyPlus was used to building energy. Cases of glazing are three types; single coated Low-e clear glazing, tripple coated Low-e clear glazing, tripple coated Low-e tinted glazing. The results of this study are follows; 1) The building energy consumption of Alt-l, 2, 3 were about 300, 253, $259kWh/m^2{\cdot}yr$ respectively. Therefore, improvement of LSG could save the energy up to 16%. 2) The saved energy could be converted 1 billion won as annual benefit of total energy costs 3) SHGC and LSG more influence on cooling energy than heating energy in office buildings.

  • PDF

창호 에너지 소비 효율 등급제와 건물 에너지 소비의 상관관계 분석 (Correlation Analysis Between Fenestration Energy Consumption Efficiency Rating System and Building Energy Consumption)

  • 곽희정;장향인;이현수;엄재용;서승직
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.338-345
    • /
    • 2013
  • The purpose of this study is to analyze the correlation between the 'Fenestration Energy Consumption Efficiency Rating System' (hereafter referred to as FECERS) and building energy consumption. 'EnergyPlus' was used for the calculation of energy consumption in apartments and office buildings, according to FECERS's rating and SHGC. The result indicates that the FECERS has high correlation with apartments, but has low correlation with office buildings. Also, it indicates that office buildings have a large impact from SHGC, which is not reflected in the FECERS. Consequently, the FECERS needs to be improved, by adding optical properties to assessment items. Additional study is required to establish the fenestration rating system, which, on the basis of this work, has high relevance to building energy consumption.

수평면 전일사량 산출모델이 일사열취득계수 및 창면적비를 고려한 건물 에너지 성능분석에 미치는 영향 (Impact of Horizontal Global Solar Radiation Calculation Modelson Building Energy Performance Analysis Considering Solar Heat Gain Coefficient and Window-to-wall Ratio)

  • 김기한;오기환
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.39-47
    • /
    • 2014
  • Solar applications analysis and building energy performance depend on the quality of the solar resource data available. Unfortunately, most of the weather stations do not measure solar radiation data in Korea, as a reason many researchers have studied different solar radiation estimation models and suggested to apply them to various locations in Korea. In addition, they also studied the impact of hourly global solar radiation on energy performance of an office building by comparing the simulated building energy consumptions using four different weather files, one using measured, and three estimated solar radiation from different models, which are Cloud-cover Radiation Model (CRM), Zhang and Huang Model (ZHM), and Meteorological Radiation Model (MRM), and concluded that there was some impact on energy performance of the building due to the using different solar radiation models. However, the result cannot be applied to all other buildings since the simulated office building for that study only used limited building characteristics such as using fixed values of solar heat gain coefficient (SHGC) and window-to-wall ratio (WWR), which are significant parameters related to solar radiation that affect to the building energy consumptions. Therefore, there is a need to identify how the building energy consumption will be changed by varying these building parameters. In this study, the impact of one measured and three estimated global solar radiation on energy performance of the office building was conducted taking account of SHGC and WWR. As a result, it was identified that the impact of four different solar radiation data on energy performance of the office building was evident regardless SHGC and WWR changes, and concluded that the most suitable solar models was changed from the CRM/ZHM to the MRM as SHGC and WWR increases.

모델트리를 활용한 죽산보 단기조류예측에 관한 연구 (Study on the Prediction of short-term Algal Bloom in Juksan weir Using the Model Tree)

  • 이보미;이혜숙;정선아;주용은;김호준;최광순
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.450-450
    • /
    • 2018
  • 최근 기후변화와 수온상승으로 인한 녹조발생이 빈번하게 나타나며, 녹조발생에 관한 관심은 꾸준히 증가하고 있는 추세이다. 본 연구는 효율적인 녹조관리를 위하여 모델트리를 활용하여 클로로필-a 단기조류예측 기법을 개발하였다. 대상지역으로 영산강수계의 죽산보를 선정하였으며, 2013년 1월부터 2016년 12월까지 나주 수질자동측정망의 일 단위자료와 동일기간 광주 기상청의 일별 기상자료를 이용하였다. 상관 분석을 통해 T-N, T-P, N/Pratio와 클로로필-a, 수온, 일사량, 강수량을 독립변수로, 단기(t+1일, t+3일, t+5일, t+7일) 클로로필-a를 종속변수로 선정하여 단기조류예측기법을 개발하였다. 수집한 자료의 데이터세트는 격일 간격으로 Training, Testing 기간으로 구분하여 적용한 결과, 상관계수는 1일 예측 시, Training 기간에 0.89, Testing 기간에 0.91, 3일 예측 시, Training 기간에 0.74, Testing 기간에 0.68, 5일 예측 시, Training 기간에 0.70, Testing 기간에 0.66, 7일 예측 시, Training 기간에 0.63, Testing 기간에 0.62로 나타났다. RMSE(Root Mean Square Error)는 1일 예측 시, Training 기간에 13.96, Testing 기간에 12.22, 3일 예측 시, Training 기간에 20.03, Testing 기간에 22.14, 5일 예측 시, Training 기간에 21.32, Testing 기간에 22.57, 7일 예측 시, Training 기간에 23.52, Testing 기간에 23.45로 나타났다. 예측주기에 따라 모델트리와 회귀식에서 활용한 독립변수는 1일 예측 시, 모델트리는 N/Pratio, 클로로필-a, 회귀식은 클로로필-a로 다르게 나타났다. 반면, 3일, 5일, 7일 예측 시, 모델트리와 회귀식에 활용된 변수는 같게 나타났다. 클로로필-a, 수온, 일사량은 5일 예측 시 활용된 변수로, 3일 예측 시에는 기상항목인 강수량이, 7일 예측 시에는 수질항목인 T-N, N/Pratio가 추가되었다. 특히 1일 예측 시 일 때, 높은 예측정도와 활용된 변수의 수가 적게 나타나는 것을 확인하였으며, 예측기간이 길어질수록 예측의 정확성이 낮아지고, 활용된 변수의 수가 많아지는 것을 확인하였다. 향후 적정한 예측기간을 판단하고 예측가능성을 높이기 위해서는 지속적인 자료취득 및 개선이 필요하며, 이를 바탕으로 적절한 단기조류예측이 가능할 것으로 판단된다.

  • PDF

위성영상과 머신러닝 모델을 이용한 폭염기간 고해상도 기온 추정 연구 (A Study for Estimation of High Resolution Temperature Using Satellite Imagery and Machine Learning Models during Heat Waves)

  • 이달근;이미희;김보은;유정흠;오영주;박진이
    • 대한원격탐사학회지
    • /
    • 제36권5_4호
    • /
    • pp.1179-1194
    • /
    • 2020
  • 본 연구에서는 지상기상센서가 설치되지 않은 미 관측지점의 기온정보를 추정하기 위하여 K-최근접 이웃, 랜덤 포레스트, 신경망 알고리즘을 대상으로 위성영상을 이용하여 기온자료를 산출하고 그 정확성을 평가·분석하고자 하였다. 위성영상자료는 2019년에 취득된 Landsat-8과 MODIS Aqua/Terra을 이용하였으며, 기상자료는 기상청과 산림청의 AWS/ASOS 자료를 이용하였다. 또한 추정 정확도를 향상시키기 위하여 수치표면 모델, 일사량, 경사방향, 경사도를 생성하여 이용하였다. 머신러닝 알고리즘 정확도 비교는 10-fold 교차검증을 통하여 R2(결정계수) 및 RMSE(평균제곱근오차)의 통계량을 계산하여 대상지역별 추정결과를 비교하였다. 그 결과 신경망 알고리즘이 R2=0.805, RMSE=0.508로 세 알고리즘 중 가장 안정적인 결과를 나타내었다. 신경망 알고리즘을 구축된 위성영상 데이터셋에 적용하여 2019년 6월부터 9월까지의 평균기온 지도를 생성할 수 있었으며 세밀한 기온 정보를 관측할 수 있음을 확인하였다. 연구 성과는 폭염 대응 정책, 열섬완화 연구 등 국가재난안전 관리에 활용 될 수 있을 것으로 기대된다.

시뮬레이션을 이용한 외부 베네시안 블라인드의 약식 SHGC 계산법 개발 (The Development of the Simple SHGC Calculation Method in Case of a Exterior Venetian Blind Using the Simulation)

  • 엄재용;이충국;장월상;최원기
    • 한국태양에너지학회 논문집
    • /
    • 제35권2호
    • /
    • pp.73-83
    • /
    • 2015
  • When it comes to these buildings for business use, cooling load during summertime was reported to have great importance which, as a result, impressively increased interest in Solar Heat Gain Coefficient (SHGC). Such SHGC is considered to be lowered with the help of colors and functions of glass itself, internal shading devices, insulation films and others but basically, these external shading devices for initial blocking that would not allow solar heat to come in from outside the buildings are determined to be most effective. Of many different external shading devices, this thesis conducted an analysis on Exterior Venetian Blind. As for vertical shading devices, previous researches already calculated SHGC conveniently using concepts of sky-opening ratios. However in terms of the Venetian Blind, such correlation is not possibly applied. In light of that, in order to extract a valid correlation, this study first introduced a concept called shape factor, which would use the breadth and a space of a shade, before carrying out the analysis. As a consequence, the concept helped this study to find a very similar correlation. Results of the analysis are summarized as follows. (1) Regarding SHGC depending on the surface reflectance of a shade, an average of 2% error is observed and yet, the figure can always be ignored when it comes to a simple calculation. (2) As for SHGC of each bearing, this study noticed deviations of 4% or less and in the end, it is confirmed that extraction can be achieved with no more than one correlation formula. (3) When only the shape factor and nothing else is used for finding a correlation formula, the formula with a deviation of approximately 5% or less is what one would expect. (4) Since the study observed slight differences in bearings depending on ranges of the shape factors, it needed to extract a weighted value of each bearing, and learned that the smaller the shape factor, the wider the range of a weighted value. The study now suggests that a follow-up research to extract a simple calculation formula by dealing with all these various inclined angles of shade, solar radiation conditions of each region (the ratio of diffuse radiation to direct radiation and others) as well as seasonal features should be carried out.