전단보강에 따른 일방향 중공슬래브의 휨 성능 평가 (Evaluation on Flexural Performance of One-Way Hollow Slabs according to the Shear Reinforcement)

  • 유유진;석근영;김기철;강주원
    • 한국공간구조학회논문집
    • /
    • 제14권2호
    • /
    • pp.79-86
    • /
    • 2014
  • The purpose of this study is intended to determine the validity of shear reinforcement by evaluating flexural performance in the hollow slab. The hollow slab is relatively light and second moment of inertia is large. Due to these characteristics, it can be used to slab system efficiently. Therefore the prediction of the structural behaviors is very important because of decrease of shear and flexural strength which is caused by hollow section of slab interior. In this study, the flexural test were performed to analyze the flexural capacity of the hollow slab w/ or w/o shear reinforcement. A total of six full scale specimens were tested. These specimens have three cases of reinforcing bar ratio, 0.009, 0.018 and 0.024. To verify the flexural behavior such as ultimate load, load-deflection and crack pattern, the flexural experiment were tested by using loading frame. Experimental results have shown that the flexural behavior are depend on the reinforcing bar ratio. Also the hollow slab with shear reinforcement have shown flexural behavior. Therefore, it is appropriate that the hollow slab is reinforced by shear reinforcement to improve the flexural performance of the hollow slab.

비부착식 단일 강연선용 원형 정착구의 일방향 슬래브 적용에 관한 실험적 연구 (An Experimental Study on the Performance of One-Way Slab Using Unbonded Post-Tensioned Anchorage for Single Tendon)

  • 김민숙;노경민;이영학
    • 한국공간구조학회논문집
    • /
    • 제19권1호
    • /
    • pp.45-51
    • /
    • 2019
  • In this study, the static load test and the load transfer test were carried out to evaluate the structural performance of the circular anchorage proposed by the previous study. Specimens were fabricated according to KCI-PS101 and ETAG 013. As a result of the static load test, it was verified that the displacement of the wedge and the strand was kept constant when the tensile force of 80% of the nominal strength of the strand was applied. In the load transfer test, it was confirmed that all the specimens satisfied the stabilization formula of KCI-PS101 and ETAG 013. Post-tensioned one-way slab with circular anchorage were fabricated to evaluate the flexural behavior. All specimens exhibited the same flexural behavior and maximum load. However, the specimen with circular anchorage were advantageous than the rectangular anchorage one in terms of crack control of the anchorage zone.

일방향 철근 콘크리트 슬래브의 폭발 피해 분석을 위한 최적의 비파괴검사법에 관한 연구 (The Study on the Optimal NDT Method for the Explosion Damage Analysis for One-way RC Slabs)

  • 이승재;오태근;박종일;김희식
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.62-68
    • /
    • 2017
  • It is necessary to analyze on the compressive strength among material properties of concrete for confirming damages of architectures due to large explosion. A non destructive test is known as the representative methods estimating compressive strength and ultrasonic pulse velocity, rebound hardness test are widely used because of their simplicity, convenience. But combined method supplementing two types is applied at now as they are affected by the characteristics of test specimen. In this research to check damages on the members of structure before and after explosion, the characteristics of compressive strength are compared and analyzed through a real explosion test prior to full scale structures. The test results showed that the larger the TNT powder and the shorter the distance, the greater the decrease in strength before and after the explosion and that the largest displacement and moment for the explosive load and the greatest decrease in the strength at the central part. Due to the surface condition and the thickness variation of the concrete specimens, the standard deviation value is the smallest in the combining method of fusion of the ultrasonic method and rebound hardness method. Thus, the combining method can be one of appropriate methods to evaluate the strength in the reinforced concrete structures damaged by the explosion.

크림프 철망 및 단면복구 보수 모르타르를 사용한 일방향 슬래브의 휨 거동에 관한 실험적 연구 (An Experimental Study on the Flexural Behavior of One-Way Concrete Slabs Using the Restorative Mortar and Crimped Wire Mesh)

  • 이문환;송태협
    • 콘크리트학회논문집
    • /
    • 제19권5호
    • /
    • pp.569-575
    • /
    • 2007
  • 철근콘크리트 구조물의 수명 연장 및 기능 보완을 위하여 콘크리트 면의 보수를 실시할 경우 일반적으로 구조적 내력을 고려하지 않는다. 특히, 표면박락 등의 보수에는 단순하게 모르타르 도포만을 이용하여 보수가 완료되므로 별도의 구조적인 보강 성능을 발휘하지 않는다. 그러나 시공성의 향상 및 균열의 억제를 위하여 철망 등의 재료를 사용할 경우 일정부분 보강의 효과를 얻을 수 있을 것으로 예상되며, 특히, 수로 구조물과 같이 교각 간에 놓여지는 구조요소의 경우 하부면의 보수를 실시할 경우 휨 저항성의 증가를 기대할 수 있다. 따라서 본 연구에서는 크리프 철망에 의한 보수를 실시하고 보수 부위 및 보수 두께에 따른 보강 성능을 확인하고자 하였다. 이를 위하여 두께 150mm, 길이 3,000mm, 너비 600mm 슬래브를 제작하고, 상부 부분 보수, 상부 전면 보수, 하부 부분 보수, 하부 전면 보수, 크림프 철망 보강 유무 등 총 8개 실험 유형을 선택하고 이에 대한 휨 보강 성능 실험을 실시하였다. 분석 결과, 크림프 철망을 보강한 실험체에서 보수 재료의 두께가 증가할수록 항복하중 및 파괴하중은 높아지는 것으로 나타났으며, 동일 조건일 경우 하부면의 보수가 휨 하중에 대한 내력을 증가시킬 수 있는 것으로 나타났다. 또한, 휨 하중을 받는 구조물 중 부분 보수만을 실시할 경우 휨 보강 성능은 기대하기 어려운 것으로 나타났다. 결론적으로 크림프 철망에 의한 보수공법 적용 시 휨 저항성의 증가가 있는 것을 알 수 있었다.

강합성 2거더교 프리스트레스트 바닥판의 설계 최소두께 (Minimum Design Thickness of Prestressed Concrete Deck Slabs for Composite Two-Girder Bridges)

  • 황훈희;조창빈;곽종원;이용우
    • 대한토목학회논문집
    • /
    • 제26권1A호
    • /
    • pp.183-190
    • /
    • 2006
  • 2거더교를 위한 장지간 바닥판의 설계에서 바닥판의 안전성과 사용성을 만족시키면서 두께를 줄여 자중을 최소화하는 것은 중요한 요소 중의 하나이다. 이 논문에서는 2거더교를 위한 횡방향 프리스트레스트 콘크리트 바닥판의 설계 최소두께와 배근상세를 안정성, 사용성을 고려하여 제시하였다. 대상 교량은, 실용적인 2거더교를 대표할 수 있는 교량으로, 교량길이 40 m의 단순교이다. 대상교량의 바닥판의 지간을 4 m~12m로 변화시켜 가며 분석하였다. 바닥판의 이방성 거동을 고려하여 최소단면을 일방향 슬래브로 설계하고, 균열폭과 피로강도를 평가하였으며, 처짐제한을 충족시킬 수 있는 최소 수준의 두께와 비교하였다. 연구결과, 피로내구성의 확보를 위해서는 직경 16 mm이하의 철근을 사용하는 것이 좋으며, 지간이 8 m를 넘는 장지간 바닥판은 처짐에 대한 사용성이 두께 결정의 지배적 요소임을 확인하였다. 또한, 현행 도로교 설계기준의 배력 철근량 규정을 적용하면 지간 4 m 이상의 바닥판에서는 지간 3 m 이하의 바닥판에서 기대되는 정도의 교축방향의 구조적 연속성을 확보할 수 없는 것으로 나타났다.