National Data Analysis of General Radiography Projection Method in Medical Imaging (영상의학검사 일반촬영 분야의 촬영기법에 대한 분석)

  • Kim, Jung-Su;Kim, Jung-Min;Lee, Young-Han;Seo, Deok-Nam;Choi, In-Seok;Nam, So-Ra;Yoon, Yong-Su;Kim, Hyun-Ji;Min, Hye-Lim;Her, Jea;Han, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.169-175
    • /
    • 2014
  • According to database of medical institutions of health insurance review & assessment service in 2013, 1118 hospitals and clinics have department of radiology in Korea. And there are CT, fluoroscopic and general radiographic equipment in those hospitals. Above all, general radiographic equipment is the most commonly used in the radiology department. And most of the general radiographic equipment are changing the digital radiography system from the film-screen types of the radiography system nowadays. However, most of the digital radiography department are used the film-screen types of the radiography system. Therefore, in this study, we confirmed present conditions of technical items for general radiography used in hospital and research on general radiographic techniques in domestic medical institutions. We analyzed 26 radiography projection method including chest, skull, spine and pelvis which are generally used in the radiography department.

GEOMETRIC CORRECTION OF RADIOGRAPHIC IMAGES USING GENERAL PURPOSE IMAGE PROCESSING PROGRAM (일반 영상처리 프로그램을 이용한 방사선사진의 기하학적 보정에 관한 연구)

  • Cheong Ji-Seong;Kim Eun-Kyung;Lee Sang-Hoon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.371-379
    • /
    • 1994
  • 본 연구는 비규격화시켜 촬영한 두장의 방사선 사진을 일반 영상처리 프로그램으로 기하학적 보정을 하여 디지탈 공제 촬영술을 시행한 결과를 개인별로 제작된 필름유지장치를 이용하여 규격화 시켜 촬영한 두장의 방사선사진을 디지탈 공제 촬영술을 시행한 결과와 비교하여 일반 영상처리 프로그램의 임상적 유용성을 평가해보고자 시행하였다. 19명의 자원자를 대상으로 하여, 각 환자에서 4매의 하악구치부 치근단 사진을 촬영하였다. 그중 2매는 XCP 필름 유지장치만으로 평행촬영법으로 촬영하였고, 나머지 2매는 교합제에 인상재를 부가하여 개인별로 제작된 XCP필름 유지장치를 이용하여 표준화시켜 역시 평행촬영법으로 촬영하였다. 기하학적 보정은 "Adobe Photoshop"과 "NIH Image" 프로그램으로 시행하였다. 특히 "Adobe Photoshop"의 임의영상회전 기능과 "IH Image"의 공제시술시 중첩된 사진을 투명하게 보여주는 기능, 병진기능을 활용하였다. 두 사진의 유사성을 측정하기 위해 공제된 사진의 계조도의 표준편차를 구하였다. 표준화군의 평균 표준편차가 기하학적 보정군의 평균 표준편차보다 약간 낮았으나, 통계적으로 유의성이 있는 차이를 보이지는 않았다. 위의 결과로 미루어보아, 하악구치부 에서 XCP필름 유지장치로 평행촬영한 비표준화방사선사진을 "Adobe Photoshop"과 "NIH Image" 프로그램을 이용하여 기하학적 보정을 할 수 있으리라 사료된다.

  • PDF

Research on Surface Contamination Analysis of Radiology Examination Equipment in Medical Institutions (의료기관 내 영상의학 검사 장비의 표면 오염도 분석 연구)

  • Shin-Woo Lee;Da-eun Kim;Chae-won Mun;Gap-Jung Kim;Sang-Ha Kim;Hye-mi Park;Se-Jong Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.171-177
    • /
    • 2024
  • In this study, two general X-ray device, CT, and MRI inspection devices were selected from general hospitals in the Daejeon area and an experiment was conducted to predict the level of infection by measuring the surface contamination of the inspection devices at different times and to use it as basic data for infection prevention. As a result, the surface contamination level by time zone for general X-ray devices and MRI examination devices was in the order of 13H > 8H > 16H, and for CT examination devices, it was 13H > 16H > 8H, which appeared to be influenced by the number of tests. In addition, the surface contamination results for each part of the test device showed that the highest ATP contamination value was found on the stand bucky handle for the general X-ray device, the headrest for the CT examination device, and the operation switch for the MRI examination device, which was closely related to the number of contacts. As a result of comparing before and after disinfection, all devices showed a significant decrease after disinfection. Based on the results of the experiment, it is believed that it can be used as basic data to identify the level of contamination in radiology laboratories and prevent infectious diseases.

Patient Radiation Exposure Dose in Computed Tomography (전산화단층촬영장치에서 환자피폭선량)

  • Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • In case of a CT examinations, there is a difference in the distribution of radiation dose from that of general X-ray equipments, and it has been known to cause a great radiation exposure during the examinations. However, owing to its high reliability on the accuracy of a examinations result, its use has increased continuously. In consideration of such a circumstance, the CT equipment, radiation dose during CT examinations, diagnostic reference level, and solutions to reduce radiation dose were mentioned on the basis of previously reported data.

Evaluation of Respiration Reproducibility of Chest General X-ray Examination using Self-made Respiratory Synchronization Device (자체 제작한 호흡 동기화 장치를 통한 흉부 일반촬영 검사의 호흡 재현성 평가)

  • Kwon, Oh-Young;Lee, Chang-Hun;Yong, Keum-Ju;Jin, Seon-Hui;Jung, Da-Bin;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1049-1056
    • /
    • 2021
  • The purpose of this study was to develop a respiratory synchronization device for X-ray (X-RSD) to increase the reproducibility of inspiration when examining the Chest X-ray of a patient who difficulty in breathing coordination. The X-RSD was self-made using an air pressure sensor and air was injected by connecting a ventilator to the mannequin for CPR. At this time, the amount of injected air was quantified using the SkillReporting device. After placing the X-RSD on the chest of the mannequin, the amount of air was tested in 6 steps from 200 to 700 cc by 100 cc increased. For the accuracy evaluation, the sensitivity of X-RSD was measured by repeating a total of 80 measurements, and the sensitivity was 100%, and very precise results were obtained. After that, the images examined while viewing the X-RSD of the chest lateral examination and the images obtained by the blind examination were compared and evaluated. The lung volume of X-RSD was larger than that of the blind test, and the deviation was smaller. Overall, the use of X-RSD can help with chest X-ray examination of patients who have difficulty in cooperating, and it is thought that it will be possible to contribute to the reduction of exposure dose by reducing the repeat rate of general X-ray examinations.

Research on the Actual Condition of Mammograpgy and Space Scattered Dose in Mammography Room (유방촬영의 실태와 유방촬영실의 공간산란선량에 관한 조사 연구)

  • Lee, In-Ja;Park, Kye-Yeon;Kim, Sung-Soo
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • I made inquires about mammographic equipments and circumstances of mammography rooms in the 64 medical facilities in areas of Seoul and Kyong Gi Do. Moreover I had experments about exposure dose with patients and radiologic technologists. so there is the data indicated follows. 1. There are inclined to improve in quality and function of mammographic equipments, it has been proven that s/f system exchanged to DR system. 2. It is certain that the number of examinations are becoming increasingly significant. 3. The Space Scattered Dose of mammography rooms are much more larger than portable equipments. 4. I worry about the affection of expose dose about Space Scattered Dose of mammography room. 5. There is need of study how to cope with the situation about increasing exposure dose of radiologic technologists in small space and numeruous number of examinations.

  • PDF

Change of Dose Exposure and Improvement of Image Quality by Additional Filtration in Mammography (유방촬영용장치 부가필터에 따른 선량변화 및 화질개선)

  • Cho, Woo Il;Kim, Young Kuen;Lee, Gil Dong
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.78-90
    • /
    • 2013
  • Recently, the interest on exposure to radiation is rising. The radiation exposure of mammography is higher in absorbed dose than of X-ray, therefore unnecessary exposure needs to be reduced, and higher image quality is needed. Generally, ray quality of the radiation imaging is an important factor that determines image quality and the amount of ray exposure, and they are affected by tube voltage and added filter. The X-ray energy that is exposed from mammography device is generally a continuous spectrum, which includes low energy that has minute influence on the image quality, and high energy that hinders contrast on image. Currently, molybdenum (Mo) and rhodium (Rh) are the most used added filters for mammography device, and they are used differently according to the energy region of X-ray. This study aims to find out the degree of reduction in exposure dose according to the thickness of aluminum (Al), and to study the changes in image quality and dose when the added filter plates that are made with niobium (Nb) or zirconium (Zr) are used, other than molybdenum (Mo) and rhodium (Rh), the two most used added filters that have similar atomic number and K-absorption regions as Nb and Zr. In this study, single-added filters of molybdenum (Mo), niobium (Nb), and zirconium (Zr) are used, and in some cases, Aluminum (Al) is combined with the single filters. In this case, image quality is considered to be improved depending on the type of added filters, and by using Aluminum (Al) filter together with the others, unnecessary X-ray of low energy would be absorbed, therefore the dose is expected to decrease without any influence when the concentration level becomes identical.

Usefulness Evaluation of Mammographic Image (유방촬영 영상의 유용성 평가)

  • Kang, Se-Ssik
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.49-54
    • /
    • 2004
  • Purpose : To valuate the usefulness of mammographic image by using phantom 1,2 to controls the enhancement of image quality. Procedure : Set up same equipments for experiment (all the qualification must be the same). Control group and 4 other experiment the developing mammographys by using the image system with film/intensifying screen and distribute marks on each test objects of phantom 1, 2. Result : The results of the experiment using phantom 1, 2 on control group and 4 others are : 1. phantom 1's valuation with 3 items. - control group received 29 out of 32 - group A received 25 - group B received 16 - group C received 11.5 - group D received 28.5 The evaluation shows that the system has proved to display excellent image quality except group B and C. 2. Phantom 2's valuation with 4 items. - control group received 38 out of 38 - group A received 30 - group B received 16 - group C received 12.5 - group D received 38 Even with phantom 2, group B and C has displayed poor image quality. Conclusion : Both experiments using phantom 1 and 2 have shown that the most strong factor that control and influence the image quality are the filming equipments. Especially, the developing system has most powerful influence above all.

  • PDF